57% found this document useful (7 votes)
23K views

Cu PVC

This document describes copper conductor PVC insulated building wire and flexible copper conductor PVC insulated wire. It provides specifications for the conductor, which is annealed plain copper, and insulation, which is extruded PVC. It is intended for permanent installation in conduit or exposed wiring in dry locations. Tables provide information on wire sizes, current carrying capacities, insulation thicknesses, diameters and weights.

Uploaded by

Fani Dwi Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
57% found this document useful (7 votes)
23K views

Cu PVC

This document describes copper conductor PVC insulated building wire and flexible copper conductor PVC insulated wire. It provides specifications for the conductor, which is annealed plain copper, and insulation, which is extruded PVC. It is intended for permanent installation in conduit or exposed wiring in dry locations. Tables provide information on wire sizes, current carrying capacities, insulation thicknesses, diameters and weights.

Uploaded by

Fani Dwi Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Copper Conductor PVC Insulated Building Wire

Cu/PVC 450/750 V (NYA)


Specification
:
SNI 04-6629.3 : 2006

Constructions:
Applications:
Permanent Installation in conduit or exposed wiring in dry location.

Conductor
Annealed plain copper round circular stranded or according to
SNI IEC 60228

Note : [re] round solid conductor


[rm] circular stranded conductor

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI 6629.1 ; SNI 04-6629.3

Packing : [C] Coil


[D] Drum

Colour :
- Yellow Strip Green or Light Blue or Black or Yellow or Red

Current Carrying
Capacity at 30C

Short Circuit
Current
Capacity at
1.0 Second

Conductor
Nominal
Cross-section
Area

Nominal
Thickness of
Insulation

Overall
Diameter
(approx)

Weight
of Cable
(approx)

Min. Insulation
DC. Resistance
at 20C

sq.mm

mm

mm

kg/km

M.Ohm.

kA

mm

1.5 re

0.7

3.3

19

50

15

24

0.17

100/C

1.5 rm

0.7

3.4

20

50

15

24

0.17

100/C

2.5 re

0.8

3.9

31

50

19

32

0.29

100/C

2.5 rm

0.8

4.2

33

50

19

32

0.29

100/C

4 re

0.8

4.4

45

50

25

42

0.46

100/C

4 rm

0.8

4.7

48

50

25

42

0.46

100/C

6 re

0.8

4.9

65

50

33

54

0.69

100/C

6 rm

0.8

5.4

71

50

33

54

0.69

100/C

10 re

1.0

6.1

92

40

45

73

1.15

100/C

10 rm

1.0

6.8

108

40

45

73

1.15

100/C

16 rm

1.0

8.0

175

40

61

98

1.84

3000/D

25 rm

1.2

9.8

273

40

83

129

2.88

3000/D

35 rm

1.2

11

367

40

103

158

4.03

2000/D

50 rm

1.4

13

523

30

132

197

5.75

1000/D

70 rm

1.4

15

692

30

165

245

8.05

1000/D

95 rm

1.6

17

962

30

197

290

10.93

1000/D

120 rm

1.6

19

1192

30

235

345

13.80

500/D

150 rm

1.8

21

1511

20

390

17.25

500/D

185 rm

2.0

23.5

1844

20

445

21.28

500/D

240 rm

2.2

26.5

2430

20

525

27.60

500/D

300 rm

2.4

29.5

3015

20

605

34.50

500/D

400 rm

2.6

33.5

3863

20

725

46.00

500/D

[email protected]

In Pipe

In Air

Standard
Delivery
Length

Single Core Flexible Copper Conductor PVC Insulated

Cu/PVC-f 450/750 V (NYAF)


Specification
:
SNI 04-6629.5 : 2006

Constructions:
Conductor
Annealed plain copper wires bunch stranded, according toSNI
IEC 60228

Applications:
Used for fixed Installation inside appliances,switchgear and controlgear.
Note

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI 6629.1 ; SNI 04-6629.5

: [f] Flexible bunched wire

Packing : [C] Coil


[D] Drum

Colour :
- Yellow Strip Green or Light Blue or Black or Yellow or Red

Conductor
Nominal
crosssection
area
sq.mm

No. of wire
and
Diameter
mm

0.5 f

16/0.2

0.75 f

Nominal
thickness
Insulation

Overall
Weight
Diameter of Cable
(approx)

(approx)

mm

mm

kg/km

0.6

2.6

10

24/0.2

0.6

2.8

1.0 f

32/0.2

0.6

1.5 f

30/0.25

0.7

2.5 f

50/0.25

0.8

4f

56/0.3

Min. Insulation
DC. Resistance
at 20C

Current Carrying
Capacity at 30C

Short Circuit
Current
Capacity at
1.0 Second

Standard
Delivery
Length

In Pipe

In Air

M.Ohm.km

kA

50

2.5

0.06

100/C

13

50

0.09

100/C

16

50

11

19

0.12

100/C

3.5

23

50

15

24

0.17

100/C

4.2

36

50

20

32

0.29

100/C

0.8

51

50

25

41

0.46

100/C

6f

84/0.3

0.8

6.3

73

50

33

53

0.69

100/C

10 f

84/0.4

1.0

7.4

116

50

45

72

1.15

100/C

16 f

126/0.4

1.0

8.6

180

40

61

97

1.84

100/C

25 f

196/0.4

1.2

10.8

275

40

82

128

2.88

500/D

35 f

278/0.4

1.2

12

385

40

102

156

4.03

500/D

50 f

398/0.4

1.4

14.5

550

40

131

195

5.75

500/D

70 f

360/0.5

1.4

16.5

750

30

164

243

8.05

500/D

95 f

475/0.5

1.6

19.5

1000

30

205

287

10.93

500/D

120 f

608/0.5

1.6

21

1240

30

233

342

13.80

500/D

150 f

760/0.5

1.8

23.5

1550

30

386

17.25

500/D

185 f

925/0.5

26

1900

20

441

21.28

500/D

240 f

1221/0.5

2.2

29.5

2450

20

525

27.60

500/D

300 f

1517/0.5

2.4

32.5

3025

20

605

34.50

500/D

[email protected]