Experiment 2
Experiment 2
EXPERIMENT NO. 2
ME139L A1
Group No. 3
SCORE
TABLE OF CONTENTS
OBJECTIVES
THEORY/HYPOTHESIS
LIST OF APPARATUS
PROCEDURE
SET-UP
DISCUSSION
CONCLUSION
10
REFERENCES
11
*PDS
OBJECTIVES:
1. To determine the flash and fire points of lubricating oils by open cup method.
2. To determine the melting point of grease.
THEORY/HYPOTHESIS:
The flash point is the lowest temperature to which a lubricant must be heated before its
vapour, when mixed with air, will ignite but not continue to burn. The fire point is the
temperature at which the lubricant combustion will be sustained. The flash and fire points are
useful in determining a lubricants volatility and fire resistance. The flash point can be used to
determine the transportation and storage temperature requirements for lubricants. Lubricant
producers can also use the flash point to detect potential product contamination. A lubricant
exhibiting a flash point significantly lower than normal will be suspected of contamination with a
volatile product. Products with a flash point less than 38 C (100F) will usually require special
precautions for safe handling. The fire point for a lubricant is usually 8 to 10 percent above flash
point. The flash point and fire point should not be confused with the auto-ignition temperature of
a lubricant, which is the temperature at which a lubricant will ignite spontaneously without an
external ignition source.
Since lubricating oil can be oxidize, so can the base oil in grease. When the grease
oxidizes, it usually darkens; there is a build-up of acidic oxidation products, just as in other
lubrications. These products can have a destructive effect on the thickener, causing softening, oil
bleeding, and leakage. Because grease does not conduct heat easily, serious oxidation can begin
at a hot point and spread slowly through the grease. This produces carbonization and progressive
hardening or crust formation. All things considered the effects of oxidation are more harmful in
grease than in oil.
The rate of oxidation is mainly dependent on the temperature. Here it is good to
understand that if soap-based grease is heated, its penetration increases only very slowly until a
certain critical temperature is reached. At this point the gel structure breaks down, and the whole
grease becomes liquid. This critical temperature is called the drop point.
Grease, when heated above its drop point and then allowed to cool it usually does not
fully regain its grease-like consistency, and its performance subsequently will be unsatisfactory.
Therefore, it follows that at no time should the drop point be exceeded. The problem with multipurpose greases is that at least one of the agents will exceed its drop point thus adversely
affecting the saponification process. Grease has a maximum temperature at which it can safely
be used. Therefore, it follows that it must also have a minimum temperature. This minimum
temperature is the point where the grease becomes too hard for the bearing, or other greased
component, to be used. Again, the base oil of the grease determines the minimum temperature.
Obviously, the base oil of the grease for low-temperature service must be made from oils having
a low viscosity at that temperature.
LIST OF APPARATUS:
1. Open Cup Tester
2. Bunsen Burner
3. Thermometer
4. Graduated Cylinder
5. Tripod
6. Test Tube
7. Grease Cup
8. Beaker
9. Test Tube Holder
10. Wire Gauze
PROCEDURE:
Flash and Fire Point of Lubricating Oils (SAE 10, SAE 30)
1.
2.
3.
4.
5.
6.
7.
Place the oil (70mL of SAE 30) to be tested inside the cup.
Heat the sample.
Pass a flame of about half an inch over the oil.
Wait until the greenish vapors are emitted.
Once again, pass a flame over the oil.
When it sparks, get the temperature and record it as the flash point.
Continue heating the sample until the sample burns. Get the temperature when it starts to
burn and record this as the fire point.
Grease Drop Test (Multi-purpose Grease)
1.
2.
3.
4.
5.
6.
7.
8.
Place the grease in the metal cup. Make sure it is totally filled by grease.
Place the metal cup inside the test tube.
Place the cork and thermometer inside the test tube.
Place the test tube sample inside the beaker, the test tube sample must be partially
submerged in the cooking oil.
Place the beaker on the tripod with the wire gauze.
Set up the Bunsen Burner.
Heat the beaker containing the sample and the cooking oil.
When the grease melts, record the temperature from the thermometer inside the test tube
and record as the melting point.
SET-UP OF APPARATUS
In the grease drop test, a sample was first poured in a test tube and a thermometer was
inserted in the tube in a manner shown in figure 2. The grease was heated through the use of a
Bunsen burner as shown in figure 3. When it melted, the temperature was recorded.
SAE 10
TRIAL Volume
70 mL
SAE 30
FLASH
FIRE
FLASH
FIRE
Temp/time
Temp/time
Temp/time
Temp/time
162C
3mins. 17secs.
170C
3mins. 42secs.
252C
6mins. 22secs.
254C
6mins. 33secs.
TYPE OF GREASE
MULTI-PURPOSE
SAE 10W
SAE 30
SAE 40
FLASH
C (F)
264 (507)
258 (496)
264 (507)
MELTING POINT
temperature
time
92C
17mins. 59secs.
TYPICAL
FIRE
C (F)
278 (532)
274 (525)
276 (529)
POUR
C (F)
-53 (-63)
-48 (-54)
-45 (-49)
DISCUSSION
The first part of the experiment is about the determination of flash and fire points of
lubricating oils. The samples used are SAE 10 and SAE 40. The flash point was measured when
a greenish vapour are emitted once a flame was passed over the sample. While, the fire point was
measured when it starts to burn once a flame was passed over it. This was shown in figure 4. The
time for the sample to reach these two points were also recorded.Figure 5 shows some of the
apparatus and the samples used.
2. Why is it necessary to correct for temperature variations in the specific gravity test?
Specific gravity must always be referenced to a particular temperature reading
because it is temperature dependent. The specific gravity of fluid increases when its
temperature is lowered or decreases when its temperature rises.
3. Define the term pour point.
Pour point is the lowest temperature at which a lubricating oil or fluid will flow
under standardized conditions.
4. Define the term cloud point.
Cloud point is the temperature of a fluid at which soluble substances or solutes
that are dissolved become no longer soluble. They precipitate which results to a cloudy
appearance of the fluid.
5. Based on the PSME code, what type of lubricants when used will have a flash point
which will give an indication of dilution?
When the flash point of a known lubricant is different from the standard
conditions, this indicates that the fluid is diluted.
CONCLUSION
Experiment no. 2 deals with the flash and fire points of lubricating oils and the melting
point of grease which are its objectives. Flash point is defined as the lowest temperature at
which the fluid can form a mixture that ignites with oxygen. While on the other hand, fire point
is the lowest temperature at which the vapor continues to burn after being ignited. The drop point
of grease is the critical temperature where it becomes a liquid under specified conditions.
The first objective of the experiment was achieved by measuring the flash and fire points
of the sample oil using the open cup method and comparing it to the typical values. The
concentration of impurities present in the sample and the rate of heating had affected the flash
and fire points obtained. Through knowing the flash point and fire point of lubricating oil, one
can check the fire hazard involved in using and storing these lubricating oils.
The second objective of the experiment was achieved by using the grease drop test to
determine the melting point of grease. The melting or drop point plays an important role in
grease since once it is exceeded, the oil when allowed to be cooled, can no longer regain its
original characteristics or properties. The presence of substances or different agents in grease
will have an effect in its melting point. Through knowing the melting point of grease, one may
become aware of the best oil to use in particular applications and if the grease is already unable
to perform satisfactory.
REFERENCES