0% found this document useful (0 votes)
160 views3 pages

FQ, FTQ, Data Sheet 4921210047 UK

The document provides specifications for two types of single frequency meters: pointer frequency meters (FQ) and reed frequency meters (FTQ). Both are available in 72x72mm and 96x96mm sizes with robust construction. The FQ meter uses a moving coil to provide an accurate linear readout of frequency converted to a voltage signal. The FTQ meter uses vibrating metal reeds to measure frequency with a resolution of 1/4Hz within common generator ranges. Both types offer protection to IP54 and comply with EMC standards for industrial and commercial environments.

Uploaded by

Dario Guzman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
160 views3 pages

FQ, FTQ, Data Sheet 4921210047 UK

The document provides specifications for two types of single frequency meters: pointer frequency meters (FQ) and reed frequency meters (FTQ). Both are available in 72x72mm and 96x96mm sizes with robust construction. The FQ meter uses a moving coil to provide an accurate linear readout of frequency converted to a voltage signal. The FTQ meter uses vibrating metal reeds to measure frequency with a resolution of 1/4Hz within common generator ranges. Both types offer protection to IP54 and comply with EMC standards for industrial and commercial environments.

Uploaded by

Dario Guzman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

TCM-2 Thyristor Control Module

TCM-2 Thyristor
Control
DATA
SHEETModule
DATA
SHEET
DATA SHEET

Single frequency meters,


types FQ, FTQ

Robust and thoroughly tested construction


DIN size compact design: Q72, Q96
High immunity to 3rd harmonics
Suitable for all types of generating sets

Document no.: 4921210047L

Data sheet

FQ, FTQ

Available types
Size

Construction

Pointer frequency
meters (90o)

Reed frequency
meters

72 x 72 mm

FQ72-x

FTQ72-x

96 x 96 mm

FQ96-x

FTQ96-x

FQ:
Pointer frequency meter consisting of a moving coil
instrument with built-in electronics for converting the
frequency to a voltage signal. Accurate and linear readout. Exchangeable scale.
FTQ:
Reed frequency meter with one row of metal reeds
vibrating at the applied frequency (resolution: 1/4 Hz).
Available with 13 reeds (typically 47...53 Hz) or 21
reeds (typically 45...55 Hz). Exchangeable scale.
Note: FTQ72-x only 47...53 Hz and 57...63 Hz.

Technical specifications
Type: Pointer frequency meters FQ

Type: Reed frequency meters FTQ

Accuracy1):

Accuracy1):

Scale/measuring
range:

Measuring
voltage:

Class 0.5

45...55 Hz 55...65 Hz 45...65 Hz


360440 Hz (others on request)

100230V AC 15%
400440V AC 15%

Scale/measuring
range:

Measuring
voltage:

Class 0.5

45...55 Hz - 55...65 Hz 47...53 Hz - 57...63 Hz

100-110-220-230-240-380-400-415440V AC 15%

Consumption:

3...9 mA

Consumption:

Max. 15 mA

Temperature:

-10...55C (nominal)
-25...60C (operating)
-25...65C (storage)

Temperature:

-10...55C (nominal)
-25...60C (operating)
-25...65C (storage)

Shock test:

15 g 6 times 3 directions
50 g/6 ms
22 g/20 ms

EMC:

IEC/EN 61000-6-2/3

EMC:

IEC/EN 61000-6-2/3
CE-marked for residential, commercial and light industry plus industrial environment

Protection:

CE-marked for residential, commercial and light industry plus industrial environment

IP522) To IEC/EN 60529

Protection:
1)
2)

IP522) To IEC/EN 60529

-10...15...30...55C, to IEC/EN 60051-1


IP54 from front on request

Further technical specifications:


See data sheet no. 4921210012

DEIF A/S

Page 2 of 3

Data sheet

FQ, FTQ
Dimensions

All dimensions in mm

Type
FQ72-x
FQ96-x
FTQ72-x
FTQ96-x

A
72 x 72
96 x 96
72 x 72
96 x 96

B
66.5 x 66.5
90 x 90
66.5 x 66.5
90 x 90

C
5.5
5.5
5.5
5.5

D
68 x 68 + 0.7
92 x 92 + 0.8
68 x 68 + 0.7
92 x 92 + 0.8

Weight (approx. kg)


0.189
0.240
0.210
0.280

Available variants
Item no.

Variant no.

Variant description

2961410720

01

FQ72-x All frequency ranges and supply voltage incl. standard scale

2961410920

01

FQ96-x All frequency ranges and supply voltage incl. standard scale

2961460720

01

FTQ72-x 47...53 Hz, 57...63 Hz and all supply voltages incl. standard scale

2961460920

01

FTQ96-x 45...55 Hz, 55...65 Hz. All supply voltages incl. standard scale

2961460920

02

FTQ96-x 47...53 Hz, 57...63 Hz. All supply voltages incl. standard scale

Order specifications
Variants:
Additional options to the standard
variant

Mandatory information
Item no.

Type

Variant
no.

Scale/measuring
range

Measuring voltage

Option

Option

Example:
Additional options to the standard
variant

Mandatory information
Item no.

Type

Variant
no.

Scale/measuring
range

Measuring voltage

Option

2961410920-01

FQ96-x

01

4555 Hz

230V AC

IP54

Option

Due to our continuous development we reserve the right


to supply equipment which may vary from the described.
DEIF A/S, Frisenborgvej 33
DK-7800 Skive, Denmark
Tel.: +45 9614 9614, Fax: +45 9614 9615
E-mail: [email protected], URL: www.deif.com