Spirent TestCenter Software and Hardware Release Notes 4 49
Spirent TestCenter Software and Hardware Release Notes 4 49
49 Software and
Hardware Release Notes
These Release Notes are for all Spirent TestCenter software Base Packages, Test Packages and
hardware.
Click on any link in the table below to jump directly to a subject section.
Section
Description
New Features
Known Issues
Product
Obsolescence
Transceiver
Support
System
Requirements
Installation
Instructions
Documentation
Contacting Spirent
Communications
*NEW* Firmware update for Spirent DX2 Test Modules: DX2-100G-P4, DX2100GO-P4, DX2-40G-Q24, DX2-40GO-Q24, DX2-40G-Q8, DX2-40GO-Q8
Industrys best value for 100GE and 40GE testing has been updated with new per-stream statistics:
Advanced sequencing for real-time loss and sequence measurements
Jitter (Beta)
For 100GE and 40GE modes only
Software
BPK-1193A OpenFlow Controller Base Package
Emulate roaming of mobile subscribers (UE mobile device) from one location to another.
Subscribers can move to a new Access Point (AP) with new L2GGRE tunnel or new wireless
SSID (VlAN ID) and retain the same IP Address as long as lease is still valid
When a subscriber roams to new AP or SSID, it switches to INIT-Reboot state and sends out
a DHCP a Reboot command to DHCP Server to verify its lease and retain IP address.
Significant improvement on time to test including config setup, apply time, load time, wizard
setup.
Results at block level with drill down capability using Intelligent Result queries.
Enables Stateful PCE Controller to compute and initiate LSP Traffic Engineering
(TE) paths (EROs) in Segment Routing(SR) Networks (draft-sivabalan-pce-segmentrouting-03)
And enables PCC to request LSP TE paths in SR networks
Added support for SR ERO Objects with SID Node & Adjacency with SR Labels
Segment Routing now supports transport traffic over ISIS SR and OSPFv2 SR tunnels using
Next-Hop Lookup option in Traffic Binding. This allows the following transport over SR
tunnels o
L2VPN and L3VPN services over SR OSPFv2 or SR ISIS. MPLS VPN wizards have been
updated to support MPLS tunnels with SR. User can select OSPFv2 SR or ISIS SR for MPLS
core traffic binding. LDP or RSVP-TE protocols are no longer for MPLS Core transport.
Added support for LDP version2 for IPv6 (draft-pdutta-mpls-ldp-v2-00). Includes support for
128-bit LSR ID for IPv6 LDP Hello.
LDP Custom PDU support. This enables user to send out any Custom PDU in Hex format at
any time after the LDP session is UP. Allows for negative testing as well as functional testing
of new features.
BGP Enhancements
BPK-1004A/B Unicast Routing (BGP) Base Package
BGP now supports route Update without initial Withdraw on attribute change. This is available
as a Global selectable option. When this option is enabled the user can update route attributes
with a single Update (MP-REACH) when NLRI is not changed. Initial withdraw (Update with
MP-UNREACH) is not sent. This prevents any interruption to traffic forwarding. If NLRI is also
changed, Withdraw (Update with MP-UNREACH) will be sent first.
10
Internet Route-Table Import now supports import of Metric & Community Attributes. This is
supported for all route formats including Cisco, Juniper and ALU. It is supported for both
Normal and Fast Route Imports
11
Supports emulation of multiple LNS per port including dual-stack LNS on a single port.
12
LAG profiles for MX2-40G-Q3 to support multi-port LAG combinations for 40G and 10G.
Profiles supported for MX2-40G-Q3 module
o
Coming soon LAG Profiles for 40G/10G (FX2-40G-Q5) and 100G/40G/10G (MX2/FX2/DX2100G-P4, MX/FX-100G-P2, MX/FX-100G-F2)
13
Known Issues
Hardware
Problems that result in a major loss of chassis functionality or a system crash are listed below.
The power button in the front of the SPT-N11U works differently than the power button on the
SPT-11U. On the SPT-N11U a simple push and release of the power button initiates a graceful
shutdown. If you need to force a shutdown you push the power button and hold it for five
seconds. Please note the difference because the procedure to gracefully shut down the SPT-11U
chassis will cause a forced shutdown of the SPT-N11U chassis.
On the control module is an Ethernet RJ-45 port labeled 1588. This port is only supported with
revision B chassis controllers.
When you initially power up the chassis the fans do not come on. This is normal. The fans are
not required to boot the system control module. Once the control module has booted the test
modules are turned on. At this time the fans are also turned on to cool them.
When creating a time synchronization chain involving multiple chassis you must first cable the
chassis together and then reboot the entire system. If you change the synchronization status of a
chassis (from master to slave for example) you must reboot the chassis.
When connecting chassis in a synch-chain, the time synchronization topology takes a long time to
be displayed in the Spirent TestCenter software.
14
Upgrading from release 4.39 or earlier to release 4.40 or later requires a system re-image. Once
the system is re-imaged, subsequent installs of 4.40 or later will not require a re-image.
10GE Spirent TestCenter control plane traffic is limited to frames of 4095 bytes or less in length.
CR #2179531351. Systems with NIC-33 (4x1G copper) can take upwards of 30 minutes to boot.
WAIT FOR THE SYSTEM TO COMPLETE THE BOOT PROCESS before power cycling or
unplugging the power. The boot time can be sped up by using a console to hit the carriage return
at the point the cursor is blinking.
CR #2179767971. The dual NIC C1-KIT-03-STC and C1-KIT-03-STC-ALL kits are Spirent
TestCenter only. These are shown as SPT-C1-7 in the GUI. APPLYING THE L4L7 TEST
PACKAGE TO THIS CONFIG WILL CORRUPT THE HARD DRIVE OF THE SYSTEM
AND REQUIRE RE-IMAGING TO RECOVER THE APPLIANCE.
CR #2169633025. Cards running in 10G per-port reservation mode may fail to synch with the
chassis backplane. Reboot the affected modules to regain synch.
MX-10G-SX
Replaying a large video file may result in a low memory issue and cause the port to go down.
A port may drop link under constant regression testing. The work around is to reboot the port.
CR #918976824. Some large stream count tests may result in stream counts that are off by 1
frame
CR #967564262. Applying a new ppm value may cause a link flap and FCS errors.
Some large stream count tests may result in stream counts that are off by 1 frame
Performing 40G to 10G and 10G to 40G speed switching may cause some ports to go offline.
Reboot the test module to recover the ports.
15
FX/MX-10G-Cx
Please download the latest Product Alert for Spirent TestCenter Power and Cooling for important
information about known power and cooling limitations.
PPM adjustment is only supported on a test-module basis. All ports must be reserved to adjust the
PPM on any of them. If a port is released the entire module will revert back to 0 PPM.
When using the API the port may not be configured to simultaneously advertise the ability to link
at 10Gbps and 1Gbps. This limitation does not apply to a test configured from the GUI.
MX2-100GO-P4
Individual Port Group Reset is not supported on Colossus MX2. If attempted, the entire test
module will reboot. This is expected to be fixed in the next release.
CR2257576981 issue on cut through channel severely limits performance for control plane
packets. In certain circumstances throughput will degrade as the test progresses.
ACC-6094A
AN (CR4 Auto-Negotiation) has not been tested or verified on QSFP28. Awaiting availability
of supported vendor optics and cables.
CV-10G-S8
The CV module will default the PFC settings on. This default will consume more memory on the
port itself and could impact some of the advertised scalability numbers for the control-plane
emulation protocols. Workaround: When creating a new configuration, on the Port Setups PFC
Measurement tab, disable all the Priority Enabled Queues. Take the port offline and then
bring it back online. This will clear the PFC information running on the port and free up memory
to run non PFC tests.
16
DX-10G-S32
Revision B hardware does not properly control the Link LED while in 1G mode. Link is properly
indicated in the GUI. The hardware revision can be viewed in the GUI using the
ToolsEquipment InformationTest Module view and by scrolling to the Hardware Version
column at the far right.
Changing speed to 1G while PPM adjust = 100, a validation error is thrown and PPM adjust is
greyed out but the ports are still in 10G. Cannot change speed when PPM adjust is not set to 0. To
recover, change the speed to 10G and apply - PPM adjust should default to 0, and then change
speed to 1G.
Revision C hardware does not support the Out of Memory daemon in this release. Testers will not
receive a warning if the module is low on memory. Please pay attention not to exceed the
supported scale metrics.
17
Software
BPK-1001A Spirent TestCenter Packet Generator and Analyzer Base Package
1. CR #2254057281 Spirent TestCenter GUI does not show the correct active L4L7 profile
for MX-40G-F2/1 and MX-100G-F2/1
2. CR #2227625661 Version shown as unknown in GUI for some test modules
3. CR #2218513961 Port groups intermittently down during speed switching
4. CR #2255328721 Unable to download Spirent TestCenter application from browser
OpenFlow Flow action of Insert/Modify VLAN ID does not work correctly on Openflow
Switch Emulation for this release.
Switch blocks created on different ports need to be on different subnets for traffic to go out
the physical port that they are configured on.
Results Reporter
Results Reporter does not sort all data when clicking on the column headers. It only sorts what
is on the page. CR #184631206
Workaround: user must create a query to sort all the data.
The number of characters for a file name (full path) which Spirent TestCenter can handle is
limited to 222 bytes. CR # 184454263
Workaround: user must create a query to sort all the data.
The stca start command may fail if the string spirent appears in the output of the ps x
command on the host operating system. This failure may occur, for example, if there is a user
logged in with spirent in the username, or if a file in the /mnt/spirent directory is being edited.
Workaround: Quit/kill any processes that show up in the output of the ps x | grep
spirent | grep v bkd command.
Ports may be unavailable when Spirent TestCenter Anywhere is started for the first time after
an install.
18
When the user tries to reserve a newly created Spirent TestCenter virtual QEMU port, they
may encounter an Application Error, and the ports will fail to reserve.
Some versions of OpenVswitch have a bug that causes extremely low bandwidths to and from
the VM which can prevent the STC GUI from properly communicating with the VM.
Workaround: If you see a problem doing an Apply from the GUI, run the following
command on the VM:
ethtool -K <intf> tso off
where <intf> is the NIC chosen as the admin port
19
The following small form factor test modules are not supported in this Spirent TestCenter release
CPR-1001A
CPR-1001B
CPR-2001A
CPR-2001B
CPR-2002A
CPR-2002B
EDM-1001A
EDM-1001B
EDM-2001A
EDM-2001B
FBR-1001A
FBR-1001B
FBR-2001A
FBR-2001B
XFP-1001A
XFP-1001B
XFP-2001A
XFP-2001B
If you attempt to upgrade a chassis that contains one of these modules to this release you will
receive an error message requesting that you remove the modules from the chassis before you
install the firmware. You cannot upgrade a chassis to this release if one of these modules is in the
chassis.
If you insert one of these modules into a chassis that has already been booted with this release the
module will not boot and it will not appear in the GUI. The status LED will illuminate but it will
be solid amber indicating the module is not booted.
20
Transceiver Support
Spirent has a rigorous process for selecting and qualifying transceivers to operate with its test
modules. This ensures the highest quality test results and seamless operation for end users. See the
Supported Transceiver document included with this release, or contact Spirent Support Services for
the list of qualified transceivers.
The use of unqualified transceivers may cause intermittent link issues, FCS errors, dropped packets,
auto-negotiation issues and other layer 1 problems. Even rebranded transceivers based on those on
Spirents supported list may not be fully compatible.
In cases where Spirent qualified transceivers are not used, Spirent Support Services will troubleshoot
those situations where a valid support contract is in place. However, in situations where compatibility
with unqualified transceivers is suspected, Spirent Support Services may ask the customer to replace
them with transceivers on our official list.
21
System Requirements
System Test
Recommended System
22
A Spirent TestCenter STP-N11U, SPT-N4U, SPT-C1, SPT-11U, SPT-3U, SPT-2U, or SPT2000A-HS, or SPT-9000A chassis with one or more ordered test modules, personality boards (if
required), and blank panels installed. Chassis firmware must be as follows:
o Firmware v3.70 or greater for SPT-2000A-HS, SPT-2U, SPT-9000A or SPT-11U chassis.
o Firmware v3.90 or greater for SPT-3U.
o Firmware v4.00 or greater for SPT-C1.
o Firmware v4.30 or greater for SPT-N11U
o Firmware v4.33 or greater for SPT-N4U
23
Operating System
1.
2.
3.
C#
Java
VS6/g
VS6/g++ ++
4.02 or 4.02 1.6
later
or
later
Yes
Yes
Yes
Perl
C/C++
5.8.8 5.8.9
Python
Ruby
Tcl
5.14
2.6.6
2.7.5
1.86
8.4.13,
8.5.9, &
8.5.14
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes3
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes1
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
No
No
Yes1
No
Yes
Yes
Yes
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
Yes
Multi-threaded
If you are using Avalanche on Spirent TestCenter Windows 2008 server is not officially supported at this time.
Running as a 32-bit application
24
Hypervisor
VMWare ESXi
QEMU/KVM
Version
4.1, 5.3, 5.5
Fedora 20, CentOS 6.5, Ubuntu 12.04, Ubuntu 14.04
Distribution
Fedora
CentOS
Ubuntu
Version
20
6.5
12.04, 14.04
LabServer
Without LabServer, customers may connect to Spirent TestCenter using any of the above supported
operating systems as clients. However, customers using FreeBSD 6.3/7.1/8.1 clients are required
connect to Spirent TestCenter using LabServer.
25
26
Documentation
Spirent TestCenter user documentation is available in PDF and WebHelp formats.
Documents delivered in PDF format support product installation, Spirent TestCenter Virtual, Spirent
TestCenter automation, and provide testing methodology information. These documents are available
on the Spirent Communications support website (http://support.spirent.com) with the software
downloads.
Help files, included within Spirent TestCenter applications, provide reference information and context
sensitive user support. Launch a Help file by pressing F1 in an open application or by clicking the Help
button displayed in the menu bar or on a dialog box.
One PDF document is only available through the Spirent Knowledge Base.
The Spirent TestCenter Hardware Reference provides information about Spirent TestCenter
chassis, modules, module LEDs, multiple chassis connections, cables, and chassis commands. It
includes basic information about system administration functions and diagnostics.
Navigate to the Spirent Communications support website (http://support.spirent.com). Click the
Knowledge Base tab and then click Documentation in the menu bar. Enter hardware reference
in the search box on the right and click Search. Click the Spirent TestCenter Hardware
Reference link in the results list.
27
Americas
E-mail: [email protected]
Web: http://support.spirent.com
Toll Free: +1 800-SPIRENT (+1 800-774-7368) (North America)
Phone: +1 818-676-2616
Hours: Monday through Friday, 06:30 to 18:00 Pacific Time
Asia Pacific
E-mail: [email protected]
Web: http://support.spirent.com
Phone: +86 (800) 810-9529 (toll-free mainland China only)
Phone: +86 (10) 8233 0033 (China)
Operating Hours: Monday through Friday, 09:00 to 18:00 Beijing Time
The latest versions of user manuals, application notes, and software and firmware updates are
available on the Spirent Communications Customer Service Center website at
http://support.spirent.com.
Information about Spirent Communications and its products and services can be found on the main
company website at http://www.spirent.com.
Company Address
Spirent Communications, Inc.
27349 Agoura Road
Calabasas, CA 91301
USA
All of the company names and/or brand names and/or product names referred to in this document, in
particular, the name Spirent and its logo device, are either registered trademarks or trademarks of
Spirent plc and its subsidiaries, pending registration in accordance with relevant national laws. All
other registered trademarks or trademarks are the property of their respective owners.
28