STAIMO Example Report - Training Case 1
STAIMO Example Report - Training Case 1
:
:
:
523546
4321
1234
Shipyard
Yard reference
Shipbuilding Inc.
Harbour 1
4711
Ordered by
Bulkers Inc.
Haagsteeg 2, Wageningen
CONTENTS
Page
REVIEW OF TABLES AND FIGURES .........................................................................................3
1
INTRODUCTION ...................................................................................................................4
SPEEDTRIALS......................................................................................................................7
INTRODUCTION
M.V. Bulker with IMO number 1234567 has been built by Shipbuilding Inc.. The main
particulars and some specifications of the ship are presented in the tables below.
2.1
SYMBOL
LPP
B
TF
TA
MAGNITUDE
205.50
32.26
7.30
4.80
35477
UNIT
m
m
m
m
m3
MAGNITUDE
11.50
11.50
69822
Not relevant
8550
110.0
14.20
9500
110.0
8550
106.2
UNIT
m
m
m3
m2
kW
RPM
kts
kW
RPM
kW
RPM
2.2
2.3
UNIT
m
m
m3
kW
2.4
DESIGNATION
SYMBOL
Definition
Description
Sea margin
True wind speed
Significant wave height
Significant wave period
Air temperature
Water temperature
Air density
Water density
TAIR
TWATER
AIR
WATER
MAGNITUDE
UNIT
%
m/s
m
s
deg C
deg C
kg/m3
kg/m3
2.5
DESIGNATION
Definition
SYMBOL
Description
Sea margin
True wind speed
Significant wave height
Significant wave period
Air temperature
Water temperature
Air density
Water density
TAIR
TWATER
AIR
WATER
MAGNITUDE
EEDI condition
Deep water, no wind, no
waves and no current
0
0.00
0.00
0.00
15.0
15.0
1.225
1025.0
UNIT
%
m/s
m
s
deg C
deg C
kg/m3
kg/m3
SPEEDTRIALS
UNIT
m
m
m
m
m3
m2
m2
m2
m2
m
-
For all runs an average time/length between start and finish for each trial run of 10 min was
used.
During each individual run, the environmental conditions were recorded (see Table 7).
An overview of the measured speed, shaft power and propeller RPM during the speed trial
runs can be found in Table 8.
The speed trials were conducted in moderate weather conditions.
Anemometer height
[m]:
Measurement time/duration :
Moulded draught on FP [m]:
Moulded draught on AP [m]:
Moulded displacement [m^3]:
Shaft outer diameter [mm]:
Shaft inner diameter [mm]:
Shear modulus
[N/mm^2]:
42.5
10 min
4.73
7.28
35040
700
0
82649
10
4.1 Introduction
The analysis is performed in five steps:
1. Correct the measured speed/power data towards ideal trial weather conditions.
2. Conversion from the trial loading condition towards the trial condition according to the
contract.
3. Conversion from the ideal trial condition towards the contract loading/weather
condition.
4. Conversion with the specified sea margin towards the agreed service condition.
5. Conversion from the ideal trial condition towards the EEDI loading condition.
In order to determine the performance under ideal weather conditions, corrections have been
applied to each individual run. To correct the individual results for their relative wind, first for
each set of runs the correct true wind speed and direction is determined. After the individual
corrections are made, the weighted true wind average for each set of runs is taken according
to Pascal's Triangle. Based on this weighted true wind average, the runs relative wind vector
is calculated.
Measurements with a too low engine power setting are not taken into account for the ideal trial
curve.
The effect of current is eliminated by averaging the measured speeds with the means of
means method.
To come from ideal trial loading/weather condition to the EEDI condition, the speed power test
results are converted to the EEDI condition on the basis of model test results with no wind, no
waves etc. for trial loading condition and EEDI loading condition.
To determine the achieved speed and RPM values at contract service conditions, the service
power and RPM curve are intersected with the contract power of 8550 kW, MCR power of
9500 kW and NCR power of 8550 kW on the basis of a least square approximations.
To determine the achieved speed and RPM values at EEDI conditions, the power and RPM
curve are intersected with the EEDI power of 7125 kW, on the basis of least square
approximations.
Detailed descriptions concerning the theory behind all corrections are given in ITTC
Guidelines 2012.
11
[m]
[m]
[-]
12
13
14
Speed corrections:
Water depth method: Lackenby
RPM corrections:
RPM method:
The corrections are performed according the procedure described in ITTC Guidelines 2012.
All parameters for corrections are treated separately.
15
9.8067
1.051E-06
1.182
925
[m/s^2]
[m/s^2]
[kg/m^3]
[m^2]
RUN
RUNSET
ReWATER
Cfa
CX
VAWC
RWIND
VAWREF
CXI
RWINDI
[-]
[-]
[-]
[-]
[-]
[m/s]
[kN]
[m/s]
[-]
[-]
______________________________________________________________________________________________
1
1 1.391E+09 1.470E-03
-0.649
14.77
-77.3
7.21
-0.740
-21.0
2
1 1.391E+09 1.470E-03
0.149
2.61
0.6
7.02
-0.740
-19.9
3
2 1.546E+09 1.451E-03
-0.630
15.87
-86.7
7.93
-0.740
-25.5
4
2 1.546E+09 1.451E-03
0.072
3.20
0.4
7.88
-0.740
-25.1
5
2 1.546E+09 1.451E-03
-0.655
16.49
-97.4
7.90
-0.740
-25.2
6
2 1.546E+09 1.451E-03
0.167
2.80
0.7
7.97
-0.740
-25.7
7
3 1.614E+09 1.444E-03
-0.608
16.13
-86.5
8.12
-0.740
-26.7
8
3 1.614E+09 1.444E-03
0.008
4.43
0.1
8.47
-0.740
-29.0
9
3 1.614E+09 1.444E-03
-0.640
16.49
-95.1
7.97
-0.740
-25.7
10
3 1.614E+09 1.444E-03
0.056
3.08
0.3
8.59
-0.740
-29.9
11
4 1.664E+09 1.438E-03
-0.634
16.80
-97.9
8.17
-0.740
-27.0
12
4 1.664E+09 1.438E-03
0.036
3.30
0.2
8.84
-0.740
-31.6
RUN
RUNSET
ETAD
[-]
[-]
[-]
________________________
1
1
0.721
2
1
0.721
3
2
0.714
4
2
0.714
5
2
0.714
6
2
0.714
7
3
0.710
8
3
0.710
9
3
0.710
10
3
0.710
11
4
0.705
12
4
0.705
RUN
RUNSET
ReWATER
Cfa
CX
VAWC
RWIND
VAWREF
CXI
RWINDI
ETAD
16
This has resulted in the following individual corrections and averaged values for M.V. Bulker:
|_______ measurements _______| |____________________ corrections__________________| |_______ corrected ______|
RUN VSM
PSM
PDM
NM
DVS
TEMP DENS DISP
WIND
WAVES
LOAD
dN
VSC
PDC
PSC
NC
[-] [kts]
[kW]
[kW] [RPM] [kts]
[kW] [kW] [kW]
[kW]
[kW]
[kW] [RPM] [kts]
[kW]
[kW] [RPM]
_______________________________________________________________________________________________________________
Run set:
1
1 14.01
5010
4960 85.8 0.14
47.4
9.8 41.2 -555.6 -531.8 -101.4 -4.3 14.15
3869
3909
81.5
2 13.64
4958
4908 85.8 0.14
47.4
9.7 40.8
202.1
0.0
22.5 1.4 13.78
5231
5284
87.2
-------------------------Set averages ideal trial:
13.97
4550
4596
84.3
Note: Power setting too low, this averaged set is disregarded for the speed power curve.
______________________________________________________________________________________________________________
Run set:
2
3 15.42
7704
7627 97.6 0.16
64.4 15.1 63.4 -678.0 -596.5 -108.1 -3.3 15.58
6387
6452
94.3
4 15.31
7571
7495 97.6 0.16
64.4 14.8 62.3
282.3
0.0
32.0 1.5 15.47
7951
8031
99.1
5 15.35
7723
7646 97.6 0.16
64.4 15.1 63.6 -798.8 -766.1 -143.0 -4.5 15.51
6081
6142
93.1
6 15.50
7354
7280 97.6 0.16
64.4 14.4 60.5
292.7
0.0
32.5 1.5 15.66
7745
7823
99.1
-------------------------Set averages ideal trial:
15.52
7029
7100
96.2
Note: No remarks on power settings.
______________________________________________________________________________________________________________
Run set:
3
7 15.78
9224
9132 103.0 0.16
73.3 18.0 75.9 -696.2 -902.6 -138.3 -3.8 15.94
7562
7638
99.2
8 16.46
9049
8959 103.0 0.17
73.3 17.7 74.5
338.5
0.0
38.0 1.6 16.63
9500
9596 104.6
9 15.49
9175
9083 103.0 0.16
73.3 17.9 75.5 -807.1 -902.6 -151.8 -4.2 15.65
7388
7463
98.8
10 16.70
9083
8992 103.0 0.17
73.3 17.8 74.7
350.7
0.0
38.9 1.6 16.87
9548
9644 104.6
-------------------------Set averages ideal trial:
16.20
8472
8558 101.7
Note: No remarks on power settings.
______________________________________________________________________________________________________________
Run set:
4
11 15.89 10352 10248 107.2 0.16
80.4 20.2 85.2 -855.6 -937.0 -155.2 -4.0 16.05
8486
8572 103.2
12 17.18 10119 10018 107.2 0.18
80.4 19.8 83.3
384.2
0.0
42.8 1.6 17.36 10628 10736 108.8
-------------------------Set averages ideal trial:
16.70
9557
9654 106.0
Note: No remarks on power settings.
______________________________________________________________________________________________________________
General remarks:
- None
RUN
VSM
PSM
PDM
NM
DVS
TEMP
DENS
DISP
WIND
WAVES
LOAD
dN
VSC
PDC
PSC
NC
in temperature
in density
in displacement
caused by wind
due to waves (wind and swell waves)
effects of changed propeller loading
17
The ideal trial weather condition is defined as: no wind, no waves, deep water, water
temperature of 15 deg C., air temperature of 15 deg C., water density of 1025 kg/m3, air
density of 1.225 kg/m3.
The tidal curve resulting from the analysis is presented in the following table and graph:
RUN
RUNTIME
RUNTYPE
VSM VSM_average
VCX
[-]
[hh:mm]
[-]
[kts]
[kts]
[kts]
_____________________________________________________________
1
06:21
Forward run
14.01
13.83
0.33
2
06:57
Return run
13.64
13.83
0.05
3
07:54
Forward run
15.42
15.36
0.21
4
09:06
Return run
15.31
15.36
-0.10
5
10:21
Forward run
15.35
15.36
0.14
6
11:06
Return run
15.50
15.36
-0.29
7
12:16
Forward run
15.78
16.04
-0.10
8
12:53
Return run
16.46
16.04
-0.59
9
13:35
Forward run
15.49
16.04
-0.39
10
14:18
Return run
16.70
16.04
-0.83
11
15:05
Forward run
15.89
16.54
-0.48
12
15:49
Return run
17.18
16.54
-0.82
RUN
RUNTIME
RUNTYPE
VSM
VSM_average
VCX
18
19
For further analysis towards contract/service conditions, model test data is used to correct the
data to Laden/Design condition.
The following model test results are used:
LOADCONDITION
VOL
T_APP
T_FPP
VS
PS
N
ETAD
[-]
[m^3]
[m]
[m] [kts]
[kW]
[rpm]
[-]
__________________________________________________________________________________
Contract trial condition
35477
4.80
7.30 11.00
2313
66.3
0.726
Contract trial condition
35477
4.80
7.30 12.00
3035
72.6
0.727
Contract trial condition
35477
4.80
7.30 13.00
4018
79.6
0.725
Contract trial condition
35477
4.80
7.30 14.00
5225
86.8
0.720
Contract trial condition
35477
4.80
7.30 15.00
6728
94.3
0.716
Contract trial condition
35477
4.80
7.30 16.00
8716
102.5
0.710
Contract trial condition
35477
4.80
7.30 16.50
9987
107.1
0.705
Contract trial condition
35477
4.80
7.30 17.00
11503
112.3
0.700
Contract
Contract
Contract
Contract
Contract
Contract
Contract
condition
condition
condition
condition
condition
condition
condition
69822
69822
69822
69822
69822
69822
69822
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.50
11.00
12.00
13.00
14.00
14.50
15.00
16.00
3084
4068
5169
6527
7404
8451
10992
73.4
80.4
87.3
94.5
98.4
102.6
111.5
0.700
0.694
0.700
0.700
0.696
0.691
0.690
The ideal trial points are compared with the model test results in identical weather conditions.
This results in correction factors on shaft power and propeller rotation rate. The weighted
average of these factors will be used as factors on the model test results to calculate the ideal
trial curve in the contract loading condition:
VS
Pm
Nm
Pt
Nt
RUNSUM facPS facN
[kts]
[kW]
[RPM]
[kW]
[-]
[-]
[-]
[-]
__________________________________________________________________
15.52
7681
98.4
7100
96.2
4 0.924 0.978
16.20
9210
104.3
8558
101.7
4 0.929 0.975
16.70
10574
109.1
9654
106.0
2 0.913 0.972
----------Weighted average: 0.924 0.975
This means that based on the speed trials, the vessel performs 7.6% better than expected
according to the model test results.
VS
Pm
Nm
Pt
Nt
RUNSUM
facPS
facN
Ship speed
Shaft power from model test results (ideal weather condition)
Propeller rotation rate from model test results (ideal weather condition)
Shaft power from speed trial (ideal weather condition)
Propeller rotation rate from speed trial (ideal weather condition)
Number of runs per averaged speed point
Shaft power correction factor on model test results
Propeller rotation rate correction factor on model test results
Table 15 Model test results compared with sea trial data under same conditions
20
Ship speed
Shaft power from model test results (ideal weather condition, contract loading
condition)
Propeller rotation rate from model test results (ideal weather condition,
contract loading condition)
Shaft power correction factor on model test results
Propeller rotation rate correction factor on model test results
Ship shaft power in contract loading condition, ideal weather condition
Ship propeller rotation rate in contract loading condition, ideal weather
condition
Propulsive efficiency
21
None
Wave method :
Spectrum:
None
No spectrum used.
0.00
0.0
[m]
[s]
VS
VS
VAW_c
RWIND
VAW_i RWIND_i ETAD
ETAS
[kts] [m/s]
[m/s]
[kN]
[m/s]
[kN] [-]
[-]
__________________________________________________________
11.0
5.659
5.659
0.0
5.659
0.0 0.700 0.990
12.0
6.173
6.173
0.0
6.173
0.0 0.694 0.990
13.0
6.688
6.688
0.0
6.688
0.0 0.700 0.990
14.0
7.202
7.202
0.0
7.202
0.0 0.700 0.990
14.5
7.459
7.459
0.0
7.459
0.0 0.696 0.990
15.0
7.717
7.717
0.0
7.717
0.0 0.691 0.990
16.0
8.231
8.231
0.0
8.231
0.0 0.690 0.990
VS
VAW_c
RWIND
VAW_i
RWIND_i
ETAD
ETAS
Ship speed
Relative wind speed in contract weather condition
Resistance corresponding with the relative wind speed in contract weather
condition
Relative wind speed in ideal weather condition (no wind, no waves)
Resistance corresponding with the relative wind speed in ideal weather condition
Propulsive efficiency (from model test)
Shaft efficiency
22
Ship speed
Delivered power correction for wind
Delivered power correction for waves
Delivered power correction for efficiency effects of changed propeller loading
Total correction on delivered power
Total correction on shaft power
Total correction on propeller rotation rate
Ship speed
Ship shaft power in contract loading condition, ideal weather condition
Ship propeller rotation rate in contract loading condition, ideal weather
condition
Total correction on shaft power
Total correction on propeller rotation rate
Ship shaft power in contract loading condition and contract weather condition
Ship propeller rotation rate in contract loading condition and contract weather
condition
Table 19 Trial results for contract loading condition and contract weather condition
5.1
23
Ship speed
Ship shaft power in contract loading condition and contract weather condition
Ship propeller rotation rate in contract loading condition and contract weather
condition
Shaft power correction for sea margin
Correction for ship propeller rotation rate as result of sea margin
Ship shaft power in contractual service conditions
Ship propeller rotation rate in contractual service conditions
Table 20 Trial results for contract loading- and weather conditions with 15% sea margin
24
25
26
27
The contract service curve is intersected with the contract power of 8550 [kW]. A double
quadratic interpolation procedure through the points is used to determine a service speed of
14.82 kts at 101.5 RPM with 15% sea margin at a Laden/Design contract loading condition, a
true wind speed of 0.0 m/s, a significant wave height of 0.00 m and a significant wave period
of 0.0 s.
At a MCR power of 9500 kW a speed is found of 15.21 kts at 104.9 RPM.
At a NCR power of 8550 kW a speed is found of 14.82 kts at 101.5 RPM.
The rotation rate at NCR without sea margin is 103.0 and the contract rotation rate at NCR
was 106.2 RPM.
Therefore the light running margin is -3.00%.
28
EEDI CONDITION
For further analysis towards the EEDI condition, model test data is used to correct towards the
EEDI loading condition. The verifier present during the sea trials was M. Verifier from Verfying
Inc..
The following model test results are used:
LOADCONDITION
VOL
T_APP
T_FPP
VS
PS
N
ETAD
[-]
[m^3]
[m]
[m] [kts]
[kW]
[rpm]
[-]
__________________________________________________________________________________
Contract trial condition
35477
4.80
7.30 11.00
2313
66.3
0.726
Contract trial condition
35477
4.80
7.30 12.00
3035
72.6
0.727
Contract trial condition
35477
4.80
7.30 13.00
4018
79.6
0.725
Contract trial condition
35477
4.80
7.30 14.00
5225
86.8
0.720
Contract trial condition
35477
4.80
7.30 15.00
6728
94.3
0.716
Contract trial condition
35477
4.80
7.30 16.00
8716
102.5
0.710
Contract trial condition
35477
4.80
7.30 16.50
9987
107.1
0.705
Contract trial condition
35477
4.80
7.30 17.00
11503
112.3
0.700
EEDI
EEDI
EEDI
EEDI
EEDI
EEDI
EEDI
condition
condition
condition
condition
condition
condition
condition
78803
78803
78803
78803
78803
78803
78803
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
12.80
11.00
12.00
13.00
14.00
14.50
15.00
16.00
3259
4299
5462
6898
7824
8931
11616
74.9
82.0
89.1
96.4
100.4
104.7
113.7
0.683
0.677
0.683
0.683
0.679
0.674
0.673
Powering data based on model test results with no wind, no waves etc.
LOADCONDITION
VOL
T_APP
T_FPP
VS
PS
N
ETAD
The ideal trial points are compared with the model test results in identical weather conditions.
This results in correction factors on shaft power and propeller rotation rate. The weighted
average of these factors will be used as factors on the model test results to calculate the
performance in the EEDI loading condition:
VS
Pm
Nm
Pt
Nt
RUNSUM facPS facN
[kts]
[kW]
[RPM]
[kW]
[-]
[-]
[-]
[-]
__________________________________________________________________
15.52
7681
98.4
7100
96.2
4 0.924 0.978
16.20
9210
104.3
8558
101.7
4 0.929 0.975
16.70
10574
109.1
9654
106.0
2 0.913 0.972
----------Weighted average: 0.924 0.975
This means that based on the speed trials, the vessel performs 7.6% better than expected
according to the model test results.
VS
Pm
Nm
Pt
Nt
RUNSUM
facPS
facN
Table 22 Model test results compared with sea trial data under same conditions
Ship speed
Shaft power from model test results (ideal weather condition,
EEDI loading condition)
Propeller rotation rate from model test results
(ideal weather condition, EEDI loading condition)
Shaft power correction factor on model test results
Propeller rotation rate correction factor on model test results
Ship shaft power in EEDI loading condition, ideal weather condition
Ship propeller rotation rate in EEDI loading condition,
ideal weather condition
Propulsive efficiency
29
30
31
The achieved speed at the agreed contractual service condition using the service curve is
14.82 kts at 8550 kW and 101.5 RPM.
Speed at MCR using the service curve is 15.21 kts at 9500 kW and 104.9 RPM.
Speed at NCR using the service curve is 14.82 kts at 8550 kW and 101.5 RPM.
32
The verified speed at the EEDI condition using the EEDI curve is
33
AUTHENTICITY CHECK
6593
1.2.0
1234567
14.44
205.50
The computer program behind the website will inform you whether the correct version of the
software is used and whether the analysis is done according the IMO-ITTC method or with a
computer program / analysis method from an undefined source.
34
2.
User shall not transfer or sub license STAIMO or any part thereof to any third
party. The User shall take appropriate measures to ensure the observation of
this clause within his organisation.
3.
4.
STA-Group is entitled to withdraw STAIMO from the web site and to cancel
the right to use STAIMO at any time.
5.
6.
In case User encounters any error or any problem in the use of STAIMO User
shall inform STA-Group immediately and provide required information on this
problem through [email protected].
By downloading STAIMO, User accepts, and places himself under the obligation to observe
the above Conditions of Use.