100% found this document useful (1 vote)
358 views3 pages

Calculation of Flow

This document contains velocity calculations for the Pandan Pumping Station. It lists the maximum pumping capacity as 1,000 cubic meters per second or 18,989 MGD. For a pipe diameter of 1.4 meters, the velocity is calculated to be 649.612 meters per second. For a pumping capacity of 2.4 cubic meters per second, the velocity is calculated to be 1.56 meters per second. It also provides calculations for the capacity and velocity of individual pumps.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
358 views3 pages

Calculation of Flow

This document contains velocity calculations for the Pandan Pumping Station. It lists the maximum pumping capacity as 1,000 cubic meters per second or 18,989 MGD. For a pipe diameter of 1.4 meters, the velocity is calculated to be 649.612 meters per second. For a pumping capacity of 2.4 cubic meters per second, the velocity is calculated to be 1.56 meters per second. It also provides calculations for the capacity and velocity of individual pumps.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Bedok WRP/Design Calculations

VELOCITY CALCULATIONS
Building

: PANDAN PUMPING STATION

Description

General

Max Pumping Capacity

1,000.000 m3/sec

18989.01

MGD

Velocity Calculations : D = Pipe Diameter

1.400 m

A = Area

1.539 m2

Q = Pumping capacity
Velocity V = Q/A

277856433.xls/For lpsFor lps

1,000.000 m3/sec
649.612 m/sec

Page 1 of 3

18989.01 MGD

Bedok WRP/Design Calculations

VELOCITY CALCULATIONS
Velocity Calculations : D = Pipe Diameter

1.400 m

A = Area

1.539 m2

Q = Pumping capacity

2.400 m3/sec

Velocity V = Q/A

1.56 m/sec

277856433.xls/For MGDFor MGD

Page 2 of 3

Bedok WRP/Design Calculations

VELOCITY CALCULATIONS
Building

: PANDAN PUMPING STATION

Description

General

Each Pump Capacity

2.000

m3/sec

37.98

MGD

37.98

MGD

Number of Pumps

Velocity Calculations : D = Pipe Diameter

1.029 m

A = Area

0.832 m2

Q = Flow/ Pump
capacity
Velocity V = Q/A

2.000

2.40 m/sec

Number of Pumps

Flow for each


pump

1.00 m3/sec
18.99

277856433.xls/Pipe

m3/sec

1000 l/s

MGD

Page 3 of 3