Lecture 11 Decanters
Lecture 11 Decanters
the
gravity
proprietary
settling
equipment
tank,
is
the
also
decanter.
used
to
Various
promote
where
emulsions
are
likely
to
form.
Centrifugal
Decanters (settlers)
Decanters are used to separate liquids where there is a sufficient
difference in density between the liquids for the droplets to settle readily.
Decanters are essentially tanks which give sufficient residence time for
the droplets of the dispersed phase to rise (or settle) to the interface
between the phases and coalesce. In an operating decanter there will be
three distinct zones or bands: clear heavy liquid; separating dispersed
liquid (the dispersion zone); and clear light liquid.
Decanters are normally designed for continuous operation, but the same
design principles will apply to batch operated units. A great variety of
vessel shapes is used for decanters, but for most applications a cylindrical
vessel will be suitable, and will be the cheapest shape. Typical designs are
shown in Figures 10.38 and 10.39. The position of the interface can be
controlled, with or without the use of instruments, by use of a
1.Decanter design
A rough estimate of the decanter volume required can be made by taking
a hold-up time of 5 to 10 min, which is usually sufficient where
emulsions are not likely to form.
The decanter vessel is sized on the basis that the velocity of the
continuous phase must be less than settling velocity of the droplets of the
dispersed phase. Plug flow is assumed, and the velocity of the continuous
phase calculated using the area of the interface:
The position of the interface should be such that the band of droplets that
collect at the interface waiting to coalesce and cross the interface does not
extend to the bottom (or top) of the vessel.
The depth of the dispersion band is a function of the liquid flow rate and
the interfacial area.
A value of 10 per cent of the decanter height is usually taken for design
purposes. If the performance of the decanter is likely to be critical the
design can be investigated using scale models. The model should be
scaled to operate at the same Reynolds number as the proposed design, so
that the effect of turbulence can be investigated.
Example
Design a decanter to separate a light oil from water.
The oil is the dispersed phase.
Oil, flow rate 1000 kg/h, density 900 kg/m3, viscosity 3 mN s/m2.
Water, flow rate 5000 kg/h, density 1000 kg/m3, viscosity 1 mN s/m2.
Solution
Take the height as twice the diameter, a reasonable value for a cylinder:
height = 2.4 m
Take the dispersion band as 10 per cent of the height = 0.24 m
Check the residence time of the droplets in the dispersion band
Piping arrangement
To minimise entrainment by the jet of liquid entering the vessel, the inlet
velocity for a decanter should keep below 1 m/s.
Proposed design
accumulating
at
the
interface
drained
off
periodically as necessary.
2. Plate separators
Stacks of horizontal, parallel, plates are used in some proprietary decanter
designs to increase the interfacial area per unit volume and to reduce
turbulence. They, in effect, convert the decanter volume into several
smaller separators connected in parallel.
3. Coalescers
Proprietary equipment, in which the dispersion is forced through some
form of coalescing medium, is often used for the coalescence and
separation of finely dispersed droplets. A medium is chosen that is
preferentially wetted by the dispersed phase; knitted wire or plastic mesh,
beds of fibrous material, or special membranes are used. The coalescing
medium works by holding up the dispersed droplets long enough for them
to form globlets of sufficient size to settle. Coalescing filters are suitable
for separating small quantities of dispersed liquids from large
throughputs.
4. Centrifugal separators
Sedimentation centrifuges
For difficult separations, where simple gravity settling is not satisfactory,
sedimentation centrifuges should be considered. Centrifuging will give a
cleaner separation than that obtainable by gravity settling. Centrifuges
can be used where the difference in gravity between the liquids is very
small, as low as 100 kg/m3, and they can handle high throughputs, up to
around 100 m3/h. Also, centrifuging will usually break any emulsion that
may form. Bowl or disc centrifuges are normally used
Hydrocyclones
Hydrocyclones are used for some liquid-liquid separations, but are not so
effective in this application as in separating solids from liquids.