FFT in Imaging Process
FFT in Imaging Process
I. INTRODUCTION
Medical imaging represent an important part of techniques for
diagnostic, scientists have discovered many methods for example:
MRI, X-ray, PET, ultrasound and Tomography. Although is
important have knowledge about FFT and histogram principles. In
the following text, we are described briefly about this topic.
X Ray: In the simplest form of X-ray imaging or radiography, a
2D projection (shadow or silhouette) of a 3D body is produced on
film by irradiating the body with X-ray photons. This mode of
imaging is referred to as projection or planar imaging [1].
Magnetic Resonance Imaging (MRI): MRI is based on the
principle of nuclear magnetic resonance, normally, nuclei NMR
active have a radiofrequency perturbation called Larmor
Frequency when a magnetic field is applied. When the
radiofrequency perturbation is stopped, RF signals are emitted
from the body and the nuclei return to their previous state of
equilibrium. This RF signals are detected by a radiofrequency
detector for then make an imaging process of signals. The main
advantage of this method is that can obtain a measure of an axis
with appropriate pulse sequences [1]. Today, MRI procedures are
based on the use of magnetic field gradients that make the
resonance field and, hence, the corresponding Larmor frequency
dependent on the position of the resonant nucleus [2].
Computed Tomography (CT): On the other hand, tomography
have a movement of the x-ray source, this can get a better image
reconstruction of the subject. CT work with the same physical
principle of x ray, but in this case only in axis of interest. In
addition, CT makes image reconstruction from the irradiation of x
ray only in the interest zone, this suppose an advantage and
advance to diagnostic of anatomic anomalies [1].
Ultrasound: Ultrasound waves are pressure waves that propagate
through tissue and are reflected at tissue interfaces [2].
Furthermore, when the wave is reflected echo is produced and this
provide a determinate spatial distribution, then we can do
reconstruction imaging. However, wave properties can affected
the quality of measured and details obtain process, for this reason,
the spatial resolution of Ultrasound is limited [1].
Positron Emission Tomography (PET): principle of positron
emission tomography. A positron emitter stabilizes upon emission
of a positron (e+) and a neutrino (location rd). The positron loses
energy due to scattering events and is finally annihilated by
capturing by an electron ( e )at r a . The annihilation event
produces two -rays (511keV) that are emitted in opposite
III. HISTOGRAM
A histogram of an image provides information about the
intensity distribution of pixels in the image. The simplest form
of a histogram is the plot of occurrence of specific gray-level
values of the pixels in the image [7].
Normalization of the observed image intensities is of crucial
importance to explore the disease progression in many clinical
studies. However, images from different scanners or with
different acquisition parameters may have large intensity
variations, which greatly affects the results of image analysis
[5].
IV. METHODS
Matlab Guide is a powerful tool to elaborate user interface,
this tool allow a better visualization and easier imaging
process. We have created a user interface to process different
techniques of medical image. First graphic show the
distribution of bottoms and figures, with these elements users
may choose an image of methods as X-ray, MRI, CT,
Ultrasound and PET. Furthermore, user interface have two
bottoms to select a FFT and Histogram. In addition, users can
interpolated the image and then get a FFT and Histogram.
b)
V. RESULTS
A.
X-ray
In the following graphs is showed a magnitude and phase of
FFT of X-ray image. However, the magnitude and phase are
different when X-ray image have a 1024x1024 size (Figure
2). In addition, when we are compared both graphs a soft
variation of FFT phase are present
a)
B.
CT
On the other hand, for this technique, we are applied the same
method, but we obtained similar features in the magnitude.
However, both graphs are different. We cannot discard a
change in the phase of FFT.
a)
D.
Ultrasound
Ultrasound image have a FFT magnitude and phase amplified
because the amount of pixels are bigger in Figure 2b, for this
reason both graphs are changed.
a)
Figure 5 CT histogram.
In this event, the major part of pixels are in the middle zone of
intensity. Therefore, intensity is close to cero.
C.
MRI
We obtained that distribution of energy of FFT was changed in
both graphs. The following graph are showing a less change in
phase.
a)
b)
b)
E.
PET
In nuclear medicine, we can obtain a PET image in the
following graph their behavior in the frequency domain is
indicated. We can see that this artifact in the first graph of
magnitude is reduced in the second.
a)
b)
VI. CONCLUSIONS
All frequencies spectra are different when the image is
interpolated. Furthermore, FFT are not equal in these methods
because techniques for get data image have diverse physical
principles.
FFT and Histogram may be the first step for then applied
filters, normalization, and similar image process methods,
because data image have special features in frequency domain.
Figure 2 a) FFT magnitude and phase of original image b)
FFT magnitude and phase of 1024 image.
The histogram indicates that it is an image in the lower
intensity of the horizontal axis, a greater number of pixels is
observed in this type of range