Leica FlexLine

TS02/TS06/TS09
Quick Guide

Version 1.0
English

To use the product in a permitted manner, please refer to the detailed safety instructions in the User
Manual.

Container Contents
a

bc d

j k

Line
a Flex 09
Leic
6/TS
/TS0
TS02
ual
Man
User

l m

n o

a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
o)
p)
q)
r)
s)
t)

GKL211 battery charger*


GFZ3 diagonal eyepiece*
GEV189 data cable (USB-RS232)*
GLI115 clip-on bubble*
GHT196 holder for height meter*
CPR105 flat prism*
GLS115 mini prism pole*
GHM007 height meter*
Protective cover / Lens hood
GEV223 data cable (USB-mini USB)
GMP111 mini prism*
Adjustment tools
GEB211 batteries*
GAD105 flat or mini prism adapter*
MS1 Leica industrial grade USB memory stick
GEB221 battery*
Tip for mini prism pole*
Counterweight for diagonal eyepiece*
Instrument with supplied tribrach
User manual and quick guide
* Optional

The GEV223 data cable (USB-mini USB) and MS1 Leica industrial grade USB memory stick are for instruments with a
Communication side cover.

User Interface
Keys
Page key. Displays the next screen when several screens are available.
FNC key. Quick-access to measurement supporting functions.
User key 1. Programmable with a function from the FNC menu.
User key 2. Programmable with a function from the FNC menu.
ENTER key. Confirms an entry and continues to the next field.
Navigation key. Controls the focus bar.

ESC key. Quits a screen or edit mode without saving changes. Returns to next higher level.
,

Function keys that are assigned the variable functions displayed at the bottom of the screen.

Alphanumeric keypad for entry of text and numerical values.

Keyboard
Standard keyboard

Alphanumeric keyboard
a

a
f

S_QG_TSOX_001

b
c
d
e

b
c
d
e

S_QG_TSOX_002

a)
b)
c)
d)
e)
f)

Fixed keys
Navigation key
ENTER key
ESC key
Function keys F1 to F4
Alphanumeric keypad

Screen
a
b
c

d
e
S_TSOX_001

a)
b)
c)
d)
e)

Title of screen
Fields
Status icons
Focus in screen. Active field
Softkeys

Status Icons
Icon

Description

Icon

Description

The battery symbol indicates the level of the


remaining battery capacity.

Telescope position face I.

Compensator is on.

Telescope position face II.

Compensator is off.

Leica standard prism.

Prism EDM mode.

Leica mini prism.

Non-Prism EDM mode.

Leica 360 prism.

Offset is active.

Leica 360 mini prism.

012

Keypad is set to numeric mode.

Leica reflector tape.

ABC

Keypad is set to alphanumeric mode.

User defined prism.

Anticlockwise horizontal angle measurement.

USB communication port is selected.

Selectable field.

Bluetooth is connected. If the icon has a


small cross beside it, the Bluetooth communication port is selected, but the status is
inactive.

Up and down arrows indicate that several


screens are available, which are accessed
using

Data Storage and Transfer


Description
An internal memory is included in all instruments. The FlexField firmware stores all data in jobs in a database in the
internal memory. Data can then be transferred to a computer or other device for post processing via a LEMO cable
connected to the serial interface RS232 port.
For instruments fitted with a Communication side cover, data can also be transferred from the internal memory to
a computer or other device via:

a USB memory stick inserted into the USB host port,

a USB cable connected to the USB device port, or

via a Bluetooth connection.

Main Menu
a

a)
b)
c)
d)
e)
f)

S_TSOX_002

Quick Survey program to begin measuring immediately.


To select and start applications.
To manage jobs, data, codelists, formats, system memory and USB memory
stick files
To export and import data.
To change EDM configurations, communication parameters and general
instrument settings.
To access instrument related tools such as check and adjust calibrations,
personal start up settings, PIN code settings, licence keys and system information.

Menu Tree
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Q-Survey
Programs
| Surveying
| Stakeout
| Free Station
| Reference Element
| Tie Distance
| Area & Volume
| Remote Height
| Construction
| Cogo
| Road 2D
| Roadworks 3D
| TraversePRO
| Reference Plane
Manage
| Jobs
| Fixpoints
| Measurements
| Codes
| Formats
| Delete Job Memory
| Memory Statistics
| USB-File Manager
Transfer
| Export Data
| Import Data

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Setting
| General
|
| Contrast, Trigger Key 1, Trigger Key 2, USER Key 1, USER Key
|
2, Tilt Correction, Hz Correction, Beep, Sector Beep, HZ
|
Increment, V-Setting, Face I Definition, Language, Language
|
Choice, Angle Unit, Minimum Reading, Distance Unit,
|
Distance Decimal, Temperature Unit, Pressure Unit, Grade
|
Unit, Data Output, GSI Format, GSI Mask, Code record, Code,
|
Display IIIumination, Reticle IIIumination, Display Heater, Pre|
/Suffix, Identifier, Sort Type, Sort Order, Double Point ID,
|
Auto-Off.
| EDM Settings
|
| EDM Setting, Atmospheric Data, Individual PPM, Projection
|
Scale, EDM Signal Reflection, EDM Frequency
| Communication Parameters
| Communication Settings, Bluetooth PIN
Tools
| Adjust
|
| Hz-Collimation
|
| V-Index
|
| Tilt Axis
|
| View Adjustment Reminder
|
| Adjustment Reminder
| Start Up
| System Information
|
| Instrument Information, Software Information, Set Date, Set
|
Time
| Licence Key
| PIN
| Load Firmware

Q-Survey Application
Description
After switching on and setting up correctly, the instrument is immediately ready for measuring.

Access
Select Q-Survey from the MAIN MENU.

QUICK-SURVEY
ALL
To start measurements and save the measured values.
DIST
To start measurements and display the measured values.
REC
To save the displayed values.
CODE
To find/enter codes.
STATION
To enter station data and set the station.
Hz=0
To set the orientation to horizontal direction = 0.
Hz / Hz
To set the horizontal angle reading to the left (anticlockwise)
or to the right (clockwise).

Next step
Measure and record the point by pressing DIST and REC, or ALL.

EDM Settings
Prism type
Fine measuring mode for high precision
measurements with prisms.

Non-PrismStd.

For distance measurements without


prisms.

Round

Mini

For long range distance measurements


with prisms.

JpMini

Miniprism.

Prism-Fast

Quick measuring mode with prisms with


higher measuring speed and reduced
accuracy.

360

PrismTracking

For continuous distance measurements


with prisms.

360
Mini

Tape

For distance measurements using Retro


reflective targets.

User1 /
User2

FlexPoint

For distance measurements without


prisms, up to ~30 m.

Tape

GMP111
Leica Constant: +17.5 mm
GMP111-0
Leica Constant: 0.0 mm

50

Prism
(>3.5km)

40

None

78

59

Leica Constant: +34.4 mm

86

86

64

100

For continuous distance measurements


without prisms.

Standard prism
GPR121/111
Leica Constant: 0.0 mm

30

Non-PrismTrack.

19

26
48
38

PrismStandard

86

EDM mode

GRZ4/122
Leica Constant: +23.1 mm
GRZ101
Leica Constant: +30.0 mm

The user can define two of their own prisms.


Constants can be entered in mm.
Leica Constant: +34.4 mm
Without prism.

Leica Constant: +34.4 mm

Ask your local Leica dealer for more information about our TQM program.

Leica Geosystems AG
Heinrich-Wild-Strasse
CH-9435 Heerbrugg
Switzerland
Phone +41 71 727 31 31
www.leica-geosystems.com

Original text

Printed in Switzerland 2008 Leica Geosystems AG, Heerbrugg, Switzerland

Leica Geosystems AG, Heerbrugg, Switzerland, has been


certified as being equipped with a quality system which
meets the International Standards of Quality Management
and Quality Systems (ISO standard 9001) and Environmental
Management Systems (ISO standard 14001).