0% found this document useful (0 votes)
341 views4 pages

Internal Arc Testing of MV Switchgear - IEC 62271-200 (Part One) - EEP

ARC test
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
341 views4 pages

Internal Arc Testing of MV Switchgear - IEC 62271-200 (Part One) - EEP

ARC test
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

09/11/2015

InternalarctestingofMVswitchgearIEC62271200(partone)|EEP

InternalarctestingofMVswitchgear
IEC62271200(partone)

Get
PDF
TOP

SHARE

Schneider Electric (ex Areva) medium voltage switchgear

Introduction
Mediumvoltageairinsulatedandgasinsulatedswitchgearforelectrical
transmissionanddistributionaredesignedandtestedinaccordancetonationaland
internationalstandardstoguaranteehighreliabilityofoperationandsafety.
Manufacturersofelectricalswitchgeardevelop,inacontinuousdialogwiththeend
user,theplantcomponentsunderthetechnicalandeconomicrequirements,whilst
respectingthenationalandinternationalspecificationsandtestrequirements.The
definedtypeandroutinetestsrelativetothemechanical,dielectric,thermalandother
requirementsguaranteealongtermsafeoperationalrecord.
Despitetheconstantoptimisationofelectricalswitchgearandcontrolgearitis
http://electricalengineeringportal.com/internalarctestingofmvswitchgeariec622712001

1/4

09/11/2015

InternalarctestingofMVswitchgearIEC62271200(partone)|EEP

unavoidablethatdisturbancesoccurinoperation.
Theprobabilityoftheoccurrenceofaninternalarcinmetalenclosedmedium
voltageswitchgearduringitsentireservicelifeisverylowbutitcannotbe
completelydisregarded.

Themaincausesofaninternalarcare:
Operationalandmaintenancefaults
Atmosphericandswitchingovervoltages
Dielectricfaultsofsolidinsulationmaterials(e.g.cableterminations,
voltageandcurrenttransformers)
Overstressofloadbreakswitches,circuitbreakersorfuses

Theinternalarcheatsdirectlythesurroundinginsulationgasandapartofthe
electricalenergywillbetransferredviaconvectionandheatconductioninthermal
energy,whichresultsinanoverpressureintheswitchgearcompartment.
Afterexceedingapredeterminedpressurelimit,thehotgasesexpandoverpressure
reliefdevicesintothesubstationorswitchgearbuilding.Thehotgasesandthe
transientpressurewavesmayendangerpersonsintheswitchgearroomandmay
seriouslydamagetheelectricalequipmentandthebuilding.
Oneofthemaineffectsofinternalarcsisthedynamicpressurestresson
mechanicalpartsoftheswitchgearandonthewallsofthebuilding.Toavoidthe
destructionofthesubstationortheswitchgearbuildingitisnecessarytointegrate
overpressurereliefsystemsinformofventilationopenings,ventoutletsetc.

Besidesthemechanicalstresstoequipment,thedangertopersonscloseto
theswitchgearmustbeexcluded.

Thesafetyofoperatorsagainsthotgases,radiationandfragmentationofthe
enclosuremustbesecured.Thefiveacceptancecriteriamustbefulfilledfora
successfulinternalarcteste.g.correctlysecureddoorsandcoversdonotopenor
indicatorsdonotigniteduetotheeffectsofhotgases.
Theinternalarcsafetytopersonsisprovenbythemanufacturerinrepresentative
http://electricalengineeringportal.com/internalarctestingofmvswitchgeariec622712001

2/4

09/11/2015

InternalarctestingofMVswitchgearIEC62271200(partone)|EEP

switchgearaccordingtoIEC62271200.

AUTHORS
ArnoB.Wahle
AREVAEnergietechnikGmbH
Sachsenwerk
Germany
[email protected]

Dr.RaimundF.Summer
AREVAEnergietechnikGmbH
SachsenwerkGermany
[email protected]

REFERENCES
[1]IEC62271200,firstedition,200311,ACmetalenclosedswitchgearand
controlgearforratedvoltagesabove1kVanduptoandincluding52kV
[2]IEC60298,edition3.0,12/1990,ACmetalenclosedswitchgearandcontrolgear
forratedvoltagesabove1kVanduptoandincluding52kV
[3]A.Wahle,S.Ruhland,2003,InfluenceofthenewIEC60298withrespecttothe
designofmetalenclosedmediumvoltageswitchgear,Session1,CIRED17th
Internationalconferenceonelectricitydistribution,Barcelona,Spain
[4]www.areva.com

RecommendedEEarticles//
Sharewithengineers//

AboutAuthor//

Edvard Csanyi
EdvardElectricalengineer,programmerandfounderofEEP.Highlyspecializedfor
designofLVhighpowerbusbartrunking(<6300A)inpowersubstations,buildingsand
industryfascilities.DesigningofLV/MVswitchgears.ProfessionalinAutoCAD
http://electricalengineeringportal.com/internalarctestingofmvswitchgeariec622712001

3/4

09/11/2015

InternalarctestingofMVswitchgearIEC62271200(partone)|EEP

programmingandwebdesign.PresentonGoogle+

2015EEPElectricalEngineeringPortal.AllRightsReserved|PrivacyPolicy|TermsofService |48queriesin0.153
seconds.
PoweredbyCsanyiGroup

http://electricalengineeringportal.com/internalarctestingofmvswitchgeariec622712001

4/4

You might also like