Wire Size Calculation: Array Data Standalone Calculation
Wire Size Calculation: Array Data Standalone Calculation
43.1
5.46
1.25
6.83
2
6
4
51.19
107.75
34.1266667
71.8333333
42.5866667
2
135
48
90
0.0032
1.0485
#N/A
#N/A
#N/A
#N/A
Non PV Wiring
Amperage
Wire Ampacity
AWG Wire Gauge
Distance
Voltage
Temperature
Temp Factor for Copper
Temp Change Factor
Resistance From NEC Table 8
Voltage Loss
Voltage Drop
20
31.2
8
10
24
120
0.0032
1.1454
#N/A
#N/A
#N/A
#N/A
Notes:
Page 1
Standalone Calculation
Open Circuit Voltage
Short Circuit current of panel
Cold Weather factor (-40F)
True Amperage per panel
Number of panels in series
Number of parallel strings
Series Per Wire Run
Total Array Amperage
Max Array Voltage
Max Wire Run Amperage
Max Wire Run Voltage
Max Wire Ampacity
AWG Wire Gauge
Distance
Voltage
Temperature
Temp Factor for Copper
Temp Change Factor
Resistance From NEC Table 8
Voltage Loss
Voltage Drop
Main
The formula for adjusting NEC table 8 for temperature is as follows:
R2 = R1 [1 + acu(T2 75F)] where Acu = 0.00323
Page 2
Main
43.1
5.46
1.25
6.825
2
6
6
51.1875
107.75
51.1875
107.75
63.882
1/0
130
48
50
0.0032
0.9193
0.11215
1.86271
3.88%
OK
Page 3
Main
Page 4
Comments
D17:
D23:
D24:
Enter the distance between the PV panel combiner box and the charge controller.
D25:
Enter the voltage of the wire run between the PV panels and the charge controller.
D26:
Enter the lowest or highest Operating temperature. This effects the resistance.
D37:
D38:
Enter the distance between the PV panel combiner box and the charge controller.
D39:
Enter the voltage of the wire run between the PV panels and the charge controller.
D40:
Enter the lowest or highest Operating temperature. This effects the resistance.
I11:
I12:
I15:
I16:
I17:
I23:
I24:
Enter the distance between the PV panel combiner box and the charge controller.
I25:
Enter the voltage of the wire run between the PV panels and the charge controller.
I26:
Enter the lowest or highest Operating temperature. This effects the resistance.
Page 5
VoltDrop
Voltage drop
AWG
18
16
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
NEC Table 8
DC Resistance at 167F, 1000 feet, stranded
Conductors
7
7
7
7
7
7
7
7
7
7
19
19
19
19
19
Circuit Resistance
Battery @ 12VDC
Battery @ 24VDC
Battery @ 48VDC
Battery contacts
Inverter contacts
Breaker
Conductors
0.0015
0.0030
0.0060
0.0016
0.0004
0.0020
0.0024
Page 6
0.0085
0.0053
0.0033
0.0021
0.0013
0.0008
0.0005
0.0003
0.0003
0.0002
0.0002
0.0001
0.0001
0.0001
0.0006
VoltDrop
AWG
18
16
14
12
10
8
NEC Table 8
DC Resistance at 167F, 1000 feet, solid
Area Cir. Copper
Copper
Mils
Uncoated
Coated
7.7700
8.0800
1620
4.8900
5.0800
2580
3.0700
3.1900
4110
1.9300
2.0100
6530
1.2100
1.2600
10380
0.7640
0.7860
16510
Low Temp
50
32
14
-4
-40
Factor
1.06
1.1
1.13
1.17
1.25
Page 7
0.0081
0.0051
0.0032
0.0020
0.0013
0.0008
NewPanels
Quantiy
Cost
Total
$6,540.00
$538.00
$7,078.00
165
12 Panels
12
2
$545.00
$269.00
500'
500'
1000'
500'
250'
1
1
2
1
1
$175.00
$30.38
$51.30
$14.70
$31.25
$175.00
$30.38
$102.60
$14.70
$31.25
$322.68
PVC Pipe
90 Elbows
45 Elbows
Male Thread
Access Fitting
Coupling
Locknut
1.5
1.5
1.5
1.5
1.5
1.5
1.5
14
2
3
2
1
1
1
$3.29
$1.99
$1.69
$0.59
$5.94
$0.59
$0.66
$46.06
$3.98
$5.07
$1.18
$5.94
$0.59
$0.66
$63.48
PVC Pipe
90 Elbows
45 Elbows
Male Thread
Access Fitting
Coupling
Locknut
0.75
0.75
0.75
0.75
0.75
0.75
0.75
14
2
3
2
1
1
1
$1.17
$0.75
$0.65
$0.37
$2.99
$0.75
$0.24
$16.38
$1.50
$1.95
$0.74
$2.99
$0.75
$0.24
$24.55
#2 AWG
#10AWG/2
#Cat 5e
#14AWG Speaker
#2 Bare Ground
Colotex Electric
Home Depot
Combiner Box
30A Fuse Block
8A Fuses
Isolated Ground Kit
Equip Ground, 12 lu
Lugs #6-2/0
NEMA 3R Box (8x12)
Delta Lightening Arrestor
75747
74778
15850
15846
15843
3
5
2
2
2
1
1
$9.82
$4.49
$7.50
$2.03
$3.30
$23.16
$39.00
PV Subtotal
PVC Subtotal
Wire Subtotal
Combiner Box
Total
$29.46
$22.45
$15.00
$4.06
$6.60
$23.16
$39.00
$139.73
$7,078.00
$88.03
$322.68
$24.55
$7,513.26
Page 8
Colotex Electric
NewPanels
Junction Box (6x6x4)
$10.95
Page 9
$10.95
NewPanels
Colotex Electric
Colotex Electric
Page 10
NewPanels
Page 11
Comments
C15:
5 foot sections
C24:
5 foot section
Page 12