Flowhead Ps
Flowhead Ps
Reservoir cleanup
Well intervention
Well abandonment
Well stimulation
Features
The flowhead supports the test string and provides a means of surface well control when completing, testing, or performing live well intervention operations. Two off-wing valves connect to
the kill and flow manifolds to control the flow of the wellbore fluids.
Valve actuators are controlled from a console located on the rig floor and link to the emergency
shutdown system for the flow wing valve. This configuration allows for remote shut-in of the
well at the flowhead. The handling sub attached to the top of the flowhead valve block is used
to tension the flowhead and the riser landing string.
The handling sub also provides an interface to the surface wireline or coiled tubing equipment.
A dynamic swivel is located between the main valve block and the lower master valve, allowing
rotation of the string without rotating the flowhead and preventing any rig movement from transferring torque into the riser or landing string.
Coflex support
Manual or hydraulicoperated fail-safe
actuator for wing valve
Hydraulic-operated
fail-safe actuator
for wing valve
Kill line
Flowline
Dynamic swivel
Flowhead.
Flowhead
Specifications
Model
Connections
Flowline
Kill Line
Top
Bottom
4184
FHT-F
318
FHD-P
2916
5,000 [34]
10,000 [69]
FHT-L
618
6,100 [41]
9,000 [62]
FHT-M
214
10,000 [69]
15,000 [103]
312IF Box
FHT-G
3116
10,000 [69]
15,000 [103]
FHT-GK
3116
10,000 [69]
15,000 [103]
FHT-GH
3116
6124
FHT-K
518
10,000 [69]
15,000 [103]
8784
74 ACME Box
FLHD-AA
738
10,000 [69]
15,000 [103]
FHHP-AA
638
15,000 [103]
22,500 [155]
FHT-HC
3116
15,000 [103]
22,500 [155]
FHT-HD
3116
15,000 [103]
22,500 [155]
FHT-HDK
3116
15,000 [103]
22,500 [155]
API Flange
3116BX154
3116BX154
FHT-HE
3116
15,000 [103]
22,500 [155]
5,000 [34]
10,000 [69]
10,000 [69]
15,000 [103]
API Flange
10184 ACME 2G RH
Hydraulic Valves
Flow
Master Kill
At 0 psi
At Working
Pressure
Hard Facing
(Colmonoy)
Dimensions
(L W H), ft [m]
Applied Codes
Flowhead Basket
FHT-F
Yes
No
No
300,000
[1,334]
200,000
[890]
3.77 3.61 12
[1.15 1.10 3.65]
4,200
[1,905]
1,003
[455]
FHD-P
Yes
No
No
250,000
[1,112]
200,000
[890]
3,858
[1,750]
na
FHT-L
Yes
No
Yes
500,000
[2,224]
285,000
[1,268]
10,360
[4,700]
5,510
[2,500]
FHT-M
Yes
No
Yes
250,000
[1,112]
200,000
[890]
na
4,410
[2,000]
na
Yes
No
No
490,000
[2,180]
300,000
[1,334]
75
4,805
[2,180]
4,630
[2,100]
FHT-K
Yes
No
Yes
700,000
[3,114]
380,000
[1,690]
75
13,000
[5,897]
4,630
[2,100]
FLHD-AA
Yes
Yes
Yes
1,500,000
[6,672]
750,000
[3,336]
NA
32,055
[14,540]
11,905
[5,400]
FHHP-AA
Yes
Yes
Yes
1,400,000
[6,228]
700,000
[3,114]
NA
21,500
[9,752]
14,000
[6,350]
FHT-HC
Yes
Yes
Yes
660,000
[2,936]
320,000
[1,423]
75
6,835
[3,100]
4,630
[2,100]
Yes
No
No
660,000
[2,936]
320,000
[1,423]
6,835
[3,100]
4,630
[2,100]
Yes
Yes
Yes
660,000
[2,936]
300,000
[1,334]
5,955
[2,701]
4,630
[2,100]
FHT-G
FHT-GK
FHT-GH
FHT-HD
FHT-HDK
FHT-HE
75
75
Det
Norske Veritas
with British Standard Code of Practice for Inspection and Repair of Offshore Containers
Not applicable
Automatic and manual
Complies
www.slb.com/BeCertain
*Mark of Schlumberger
Other company, product, and service names
are the properties of their respective owners.
Copyright 2011 Schlumberger. All rights reserved. 11-TS-0086