Product Overview
Thank you for selecting the APCEM desktop CO2 monitor. It is smart, compact and easy-to-use. In addition to measuring the CO2 concentration,
The APCEM can also measure the ambient temperature and the relative humidity. This product is developed to detect the presence of CO2 in ambient air
and help plants to grow well. The APCEM can be used in greenhouse, hydroponics room and other place where plants need to grow well.
Features:
The built-in Data logger can store 48 sets of CO2 and temperature and RH in the past 24 hours; one log per 30 minutes.
Max/Min mode can record the maximum and minimum concentration of CO2 since the device has been last turned on.
The RCFS Mode can recover the original factory settings after the CO2 device has been recalibrated, altered, or damaged.
1. Enter Button
2. Down Button
3. Up Button
4. Mode Button
5. LCD display
6. Red LED Display (<300ppm)
Mode Functions
There are several Modes which can be adjusted by user. These modes are ALTI Mode, OUTSIDE Mode, CALI Mode, LOG Mode, MinMax Mode, and RcFS Mode
in sequence
.
ALT I
OUTSIDE
CALI
LOG
MaxMin
RcFS
Safety Instructions
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning and entire User Manual
before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, do not subject the product to impact or shock.
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in damage.
3. Do not keep the product in a hot and moist environment. Keep the product away from the heat source or near water.
4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death to the user.
To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning Disconnect the power before clean. Use a damp cloth. Do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product needs servicing.
3. Air circulation---The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked.
Customize Settings
When the power has been connected, the APCEM CO2 monitor will begin to work. In order to meet your personal requirements, it is advisable to set up the customizing
parameters.
WarmUp: It lasts approximately 1min before WARM UP disappears; all MODE functions will not response during warm up.
*Note: Temp C refers to Temperature in Celsius; Temp F refers to Temperature in Fahrenheit. Vent Rate lps refers to Liter Per Second; Vent Rate cfm/p refers to
Cubic Feet Per Minute.
.
*Note: With the Built-in MAX MIN mode, the APCEM can provide the Maximum and Minimum CO2 readings since the device has last been turned on. If users press up/down to
clear the MAX and MIN CO2 reading record, the APCEM will provide the new MAX and MIN CO2 reading from that time.
Dimensions
Inch [mm]
SPECIFICATIONS
Method - NDIR
Display - LCD
Independent CO2, RH and Temperature readings. Calculates and Displays Ventilation Rates
Sample Method - Diffusion or flow through (50 ~200 ml/min)
CO2, Temperature & RH Specification:
CO2 Specification
Measurement Range
Display Resolution
Accuracy
Temperature Dependence
Typ. 0.2% of reading per C or 2 ppm per C, whichever is greater, referenced to 25C
Pressure Dependence
Repeatability
20 ppm @ 400ppm
Response Time
Warm-Up Time
Temperature Specification
Temperature Range
Display Resolution
0.1C (0.1F)
Display Options
C/F
Response Time
Accuracy
1C( 2F) When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC
RH Specification
Operating Conditions
Measurement Range
20%-90% RH
Operating Temperature
Display Resolution
1%RH
Humidity Range
0 ~ 95% RH non-condensing
Accuracy
5%RH@23C
Storage Conditions
Response time:
Storage Temperature
Power Supply
Power Supply
This section includes a list of Frequently Asked Questions for problems you may encounter with the APCEM CO2 Monitor.
Fault Icon
Suggested Actions
This error will clear when the temperature returns to the range between 0C to
50C (32F to 122F).
Ref.No.022012