N° Products - جتنملا تا Tests - تاصوحفلا Standards - تافصاوملا

This document provides information on product testing conducted by a laboratory. It lists 8 products including air conditioners, vacuum cleaners, refrigerating appliances, washing machines, and hairdryers. For each product, it details the various tests performed in areas such as abnormal operation, insulation, markings, safety, and heat resistance. It also lists the relevant standards for each product tested.

Uploaded by

Ahmad Kalbounah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
207 views41 pages

N° Products - جتنملا تا Tests - تاصوحفلا Standards - تافصاوملا

This document provides information on product testing conducted by a laboratory. It lists 8 products including air conditioners, vacuum cleaners, refrigerating appliances, washing machines, and hairdryers. For each product, it details the various tests performed in areas such as abnormal operation, insulation, markings, safety, and heat resistance. It also lists the relevant standards for each product tested.

Uploaded by

Ahmad Kalbounah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 41

N

Products

Tests -

001

Air conditionners

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Safety requirements
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 1
)F-QM-003/Rev 00/2012(

IEC 60335-2-40

SASO 2007

SASO 2663

SASO 2763

Products

Tests -

002


Vacuum cleaners, cleaning
appliances

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards
GSO IEC 60335-2-54

IEC 60335-2-10

IEC 60335-2-2

SASO 1233

SASO 2135

SASO IEC 60335-2-67

SASO IEC 60335-2-68

SASO IEC 60335-2-69

SASO IEC 60335-2-79

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 2
)F-QM-003/Rev 00/2012(

Products

Tests -

003


Refrigerating appliances

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Dimensions, volumes and weights measurement
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

IEC 60335-2-24

SASO 1978

SASO 2664

SASO IEC 60335-2-89

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 3
)F-QM-003/Rev 00/2012(

Products

Tests -

004


Washing machines,dryers,
dishwashers

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Dimensions, volumes and weights measurement
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages
Visual inspection

Standards
GSO IEC 60335-2-5

GSO IEC 60335-2-58

GSO IEC 60335-2-62

GSO IEC 60335-2-7

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 1
)F-QM-003/Rev 00/2012(

SASO 1602

SASO 1977

SASO 2025

SASO 2692

Products

Tests -

005


Irons, ironers

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-3

GSO IEC 60335-2-44

GSO IEC 60335-2-85

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 5
)F-QM-003/Rev 00/2012(

SASO 2603

Products

Tests -

006


Fans,range hood

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-99

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 6
)F-QM-003/Rev 00/2012(

IEC 60335-2-31

IEC 60335-2-80

SASO 2027

SASO 2031

Products

Tests -

007

Room heater

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 335-2-43

GSO IEC 335-2-61

GSO IEC 335-2-66

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 7
)F-QM-003/Rev 00/2012(

IEC 60335-2-30

SASO 1599

Products

Tests -

008


Hairdryer, body , hair and
skin care

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-27

GSO IEC 60335-2-52

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 8
)F-QM-003/Rev 00/2012(

IEC 60335-2-23

SASO 2604

Products

Tests -

009


Water heater

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Endurance, aging and service output
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO 1858

GSO 1859

SASO 1698

GSO IEC 60335-2-21

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 9
)F-QM-003/Rev 00/2012(

IEC 60335-2-35

SASO 1603

Products

Tests -

010



Desert
cooler,humidifier,air
cleaning

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Normal operation
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 11
)F-QM-003/Rev 00/2012(

SASO 1922

SASO 2030

SASO 2033

SASO 36

SASO 35

Products

Tests -

011



Stationary cooking ranges
and ovens,warmers

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-49

SASO 1817

SASO 2005

SASO 2370

GSO IEC 60335-2-102

SASO IEC 60335-2-36

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 11
)F-QM-003/Rev 00/2012(

Products

Tests -

012

Portable Cooking
Appliances , commercial
grills

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO 60335-2-48

GSO IEC 60335-2-38

GSO IEC 60335-2-78

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 12
)F-QM-003/Rev 00/2012(

SASO 1600

Products

Tests -

013


Shavers, Hair Clippers

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 13
)F-QM-003/Rev 00/2012(

SASO 1604

Products

Tests -

014


Sewing machine

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 11
)F-QM-003/Rev 00/2012(

SASO 1348

Products

Tests -

015


Insect killer

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 15
)F-QM-003/Rev 00/2012(

SASO 1820

Products

Tests -

016


Portable heating tools

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-17

GSO IEC 60335-2-81

GSO IEC 60335-2-96

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 16
)F-QM-003/Rev 00/2012(

SASO 2029

Products

Tests -

017


Kitchen machine

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO 60 335-2-64

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 17
)F-QM-003/Rev 00/2012(

SASO 1601

Products

Tests -

018

Boilers,appliances for
boiling

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-50

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 18
)F-QM-003/Rev 00/2012(

SASO 1818

SASO 2606

Products

Tests -

019

) (
Microwave oven

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 19
)F-QM-003/Rev 00/2012(

SASO 1448

SASO 2032

Products

Tests -

020


Sauna appliances

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 21
)F-QM-003/Rev 00/2012(

SASO 2371

Products

Tests -

021


Medical appliances

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

SASO IEC 60601-1

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 21
)F-QM-003/Rev 00/2012(

Products

Tests -

022


Massage appliance

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 22
)F-QM-003/Rev 00/2012(

SASO 1976

Products

Tests -

023


General appliances with
transformer or motor

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Dimensions, volumes and weights measurement
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards
GSO IEC 60335-2-104
SASO IEC 60204-32
SASO IEC 60204-31
SASO IEC 60204-1
SASO IEC 60079-7
SASO IEC 60079-0
SASO 2026
SASO 1062
IEC 60204-32
IEC 60204-31
IEC 60079-7
IEC 60079-0
GSO IEC 60335-2-87
GSO IEC 60335-2-86
GSO IEC 60335-2-84
GSO IEC 60335-2-82
GSO IEC 60335-2-76
GSO IEC 60335-2-72
GSO IEC 60335-2-70

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 23
)F-QM-003/Rev 00/2012(

EN ISO 13857
EN ISO 12100
EN 60204-1

Products

Tests -

024


General appliances with
heating element

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards
GSO IEC 60335-2-101

GSO IEC 60335-2-102

GSO IEC 60335-2-71

GSO IEC 60335-2-73

GSO IEC 60335-2-74

GSO IEC 60335-2-83

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 21
)F-QM-003/Rev 00/2012(

SASO 1062

UL 1030

SASO 2606

Products

Tests -

027

Clocks

Standards

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 25
)F-QM-003/Rev 00/2012(

SASO 1819

Products

Tests -

028

Deep Fryers

Abnormal operation
Classification
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-39

GSO IEC 60335-2-47

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 26
)F-QM-003/Rev 00/2012(

SASO 1921

SASO 2372

Products

Tests -

030

Garden lawnmowers and


similaire

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals
Transient overvoltages

Standards

GSO IEC 60335-2-100

GSO IEC 60335-2-77

GSO IEC 60335-2-91

GSO IEC 60335-2-92

GSO IEC 60335-2-94

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 27
)F-QM-003/Rev 00/2012(

Products

Tests -

033



CD/DVD/K7 video players
& recorders

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals

Standards

SASO IEC 60065

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 28
)F-QM-003/Rev 00/2012(

Products

Tests -

034



Speakers, amplifiers,
intercom

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals

Standards

SASO IEC 60065

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 29
)F-QM-003/Rev 00/2012(

Products

Tests -

035


) (
Receivers

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals

Standards

SASO IEC 60065

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 31
)F-QM-003/Rev 00/2012(

Products

Tests -

036


Video cameras

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals

Standards

SASO IEC 60065

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 31
)F-QM-003/Rev 00/2012(

Products

Tests -

037



Video games

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Screws and connections
Stability and mechanical hazards
Supply connection and external flexible cords
Terminals

Standards

SASO IEC 60065

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 32
)F-QM-003/Rev 00/2012(

038

Products




Wired/Wireless phone
sets, mobile phones,
telecommunication
equipment

Tests -

Standards

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Mechanical tests
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Safety requirements
Screws and connections
Stability and mechanical hazards

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 33
)F-QM-003/Rev 00/2012(

IEC 60950

SASO 2551

039

Products




Fax machines, scanners,
printers, projectors &
similar

Tests -

Standards

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Mechanical tests
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Safety requirements
Screws and connections
Stability and mechanical hazards

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 31
)F-QM-003/Rev 00/2012(

IEC 60950

SASO 2551

Products

Tests -

040


Computers & accessories

Standards

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Mechanical tests
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Safety requirements
Screws and connections
Stability and mechanical hazards

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 35
)F-QM-003/Rev 00/2012(

IEC 60950

SASO 2551

041

Products




Copiers, office appliances
and money machines

Tests -

Standards

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Mechanical tests
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Safety requirements
Screws and connections
Stability and mechanical hazards

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 36
)F-QM-003/Rev 00/2012(

IEC 60950

SASO 2551

042

Products

Measuring and controlling


equipment

Tests -

Standards

Components and materials


Degrees of protection provided by enclosures
Heating and protection against temperature rise
Marking and instructions
Mechanical tests
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Resistance to heat, fire and tracking
Safety requirements
Stability and mechanical hazards

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 37
)F-QM-003/Rev 00/2012(

IEC 61010-1

SASO 2416

Products

Tests -

043


Uninterruptible power
systems (UPS)

Abnormal operation
Clearances, creepage distances and solid insulation
Design, construction, composition
Heating and protection against temperature rise
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Safety requirements
Screws and connections
Stability and mechanical hazards
Terminals

Standards

GSO IEC 62040-1

** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 38
)F-QM-003/Rev 00/2012(

Products

Tests -

Standards
GSO IEC 60884-1

067



Plugs, socket outlets, cord
extension sets and similar

Abnormal operation
Breaking and making capabilities
Clearances, creepage distances and solid insulation
Degrees of protection provided by enclosures
Design, construction, composition
Dimensions, volumes and weights measurement
Electrical properties : voltage, energy, resistance,
impedance, capacity and capacitance
Electrical resistance, resistivity and conductivity
Endurance, aging and service output
Heating and protection against temperature rise
Insulation, dielectric, filler, sheath and enclosures
characteristics
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Normal operation
Plugs and sockets
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Terminals

GSO IEC 60884-2-1


GSO IEC 60884-2-2
GSO IEC 60884-2-3
GSO IEC 60884-2-4
GSO IEC 60884-2-6
GSO IEC 60884-2-7
IEC 60884-1
IEC 60884-2-1
IEC 60884-2-2
IEC 60884-2-3
IEC 60884-2-4
IEC 60884-2-6
IEC 60884-2-7
SASO 2203
SASO 2204
SASO 2815

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 39
)F-QM-003/Rev 00/2012(

077

Products

Adaptor

Tests -

Abnormal operation
Breaking and making capabilities
Clearances, creepage distances and solid insulation
Degrees of protection provided by enclosures
Design, construction, composition
Dimensions, volumes and weights measurement
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Normal operation
Plugs and sockets
Protection against electric shock
Provisions for earthing
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Screws and connections
Terminals

Standards

GSO IEC 60884-2-5

* Only IPX3, IPX4, IPX7 tests for protection against water


** Humidity chamber test capacity is W 87 cm X D 73 cm X H 153 cm

11 11
)F-QM-003/Rev 00/2012(

IEC 60884-2-5

BS 1363-3

Products

Tests -

Standards
GSO IEC 60745-1
GSO IEC 60745-2-1
GSO IEC 60745-2-11
GSO IEC 60745-2-13
GSO IEC 60745-2-14
GSO IEC 60745-2-15

102


(

)...
Electric tools

Abnormal operation
Clearances, creepage distances and solid insulation
Components and materials
Design, construction, composition
Endurance, aging and service output
Evironmental stress and moisture resistance
Heating and protection against temperature rise
Internal and external wiring
Leakage current, electric strength and insulation
resistance
Marking and instructions
Mechanical strength
Power input and current
Protection against electric shock
Protection against radiation, toxicity, emitted gases
and similar hazards
Provisions for earthing
Radio and television interference suppression
Resistance to heat, fire and tracking
Resistance to rusting and corrosion
Safety requirements
Screws and connections
Stability and mechanical hazards
Starting and operating characteristics
Supply connection and external flexible cords
Terminals

GSO IEC 60745-2-16


GSO IEC 60745-2-17
GSO IEC 60745-2-18
GSO IEC 60745-2-19
GSO IEC 60745-2-2
GSO IEC 60745-2-20
GSO IEC 60745-2-21
GSO IEC 60745-2-4
GSO IEC 60745-2-5
GSO IEC 60745-2-6
GSO IEC 60745-2-7
GSO IEC 60745-2-8
GSO IEC 60745-2-9
IEC 60745-2-12
IEC 60745-2-3
IEC 61029-1
IEC 61029-2-1
IEC 61029-2-10
IEC 61029-2-11
IEC 61029-2-12
IEC 61029-2-2
IEC 61029-2-3
IEC 61029-2-4
IEC 61029-2-5
IEC 61029-2-6
IEC 61029-2-7
IEC 61029-2-8
IEC 61029-2-9