Flow Control, 3 Way, PR & Temp Compensated, NG6, Type RPC1-T3
Flow Control, 3 Way, PR & Temp Compensated, NG6, Type RPC1-T3
RPC1-T3
SUBPLATE MOUNTING
ISO 6263-03 (CETOP 03)
p max 250 bar
Q max (see table of performances)
MOUNTING INTERFACE
OPERATING PRINCIPLE
ISO 6263-03-03-*-97
(CETOP 4.5.2-3-03-250)
40.5
30.2
21.5
12.7
0.75
5.1
T
31
15.5
31.75
7.5 (max)
M5
PERFORMANCES
HYDRAULIC SYMBOL
bar
250
12
l/min
1-4-10-16-22
0,035
-20 / +50
-20 / +80
cSt
10 400
Recommended viscosity
cSt
25
Mass
kg
1,5
RPC1/T3
RPC1-/T3/M
3
1
1/4
RPC1-T3
SERIES 41
1 - IDENTIFICATION CODE
R P C 1 -
/ T 3 /
Pressure compensated
flow control valve
/ 41 /
1 = 1 l/min
4 = 4 l/min
10 = 10 l/min
16 = 16 l/min
22 = 22 l/min
Temperature compensation
Number of ways
KNOB TURNS
3 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to
ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other
kinds of fluid such as HFA, HFB, HFC, please consult our technical
department. Using fluids at temperatures higher than 80 C causes
a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical
characteristics.
5 - TEMPERATURE COMPENSATION
The valve temperature compensation is obtained with the principle
of fluid passage across a thin wall orifice in which the flow rate is not
subtantially influenced by the oil viscosity fluctuations. For
controlled flows of less than 0,5 l/min and with a temperature
difference of 50 C, flow is increased by about 13% of the set flow
value. For higher flow rates, and with the same temperature
difference, the flow increase is about 4% of the maximum flow
controlled by the valve.
4 - PRESSURE COMPENSATION
Two throttles in series are in the valve. The first is an opening
regulated by the knob; the second, piloted by the pressure
upstream and downstream of the first throttle, assures a constant
pressure drop across the adjustable throttle. In these conditions, the
set flow rate value stays constant within a tolerance range of 2%
of the maximum flow controlled by the valve for maximum pressure
variation between the intake and outlet chambers of the valve.
32 250/110 ED
2/4
RPC1-T3
SERIES 41
FASTENING BOLTS
4 bolts M5x90
Tightening torque: 5 Nm
7 - APPLICATION EXAMPLE
Adjustment knob
Type
PMMD-AI3G
with rear ports
with user P plugged
Type
PMMD-AL3G
with side ports
with user P plugged
Port dimension
3/8 BSP
B
T
32 250/110 ED
3/4
RPC1-T3
SERIES 41
32 250/110 ED
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
4/4