IEC Certification Kit

Simulink Test
Conformance Demonstration Template
R2015b

How to Contact MathWorks


Latest news:

www.mathworks.com

Sales and services:

www.mathworks.com/sales_and_services

User community:

www.mathworks.com/matlabcentral

Technical support:

www.mathworks.com/support/contact_us

Phone:

508-647-7000

The MathWorks, Inc.


3 Apple Hill Drive
Natick, MA 01760-2098
IEC Certification Kit: Simulink Test Conformance Demonstration Template

COPYRIGHT 2015 by The MathWorks, Inc.


The software described in this document is furnished under a license agreement. The software may be used or copied only under
the terms of the license agreement. No part of this manual may be photocopied or reproduced in any form without prior written
consent from The MathWorks, Inc.
FEDERAL ACQUISITION: This provision applies to all acquisitions of the Program and Documentation by, for, or through the
federal government of the United States. By accepting delivery of the Program or Documentation, the government hereby agrees
that this software or documentation qualifies as commercial computer software or commercial computer software documentation
as such terms are used or defined in FAR 12.212, DFARS Part 227.72, and DFARS 252.227-7014. Accordingly, the terms and
conditions of this Agreement and only those rights specified in this Agreement, shall pertain to and govern the use, modification,
reproduction, release, performance, display, and disclosure of the Program and Documentation by the federal government (or
other entity acquiring for or through the federal government)and shall supersede any conflicting contractual terms or conditions.
If this License fails to meet the governments needs or is inconsistent in any respect with federal procurement law, the
government agrees to return the Program and Documentation, unused, to The MathWorks, Inc.
Trademarks
MATLAB and Simulink are registered trademarks of The MathWorks, Inc. See www.mathworks.com/trademarks for a
list of additional trademarks. Other product or brand names may be trademarks or registered trademarks of their respective
holders.
Patents
MathWorks products are protected by one or more U.S. patents. Please see www.mathworks.com/patents for more
information.

Revision History
September 2015

New for IEC Certification Kit Version 3.6 (Applies to Release 2015b)

Contents
1 Introduction ...................................................................................................................................... 1-1
1.1 Conformance Demonstration Template Overview .................................................................. 1-2
1.2 Application Identification........................................................................................................ 1-3
2 Verification and Testing of Simulink Models and Code .................................................................. 2-1
3 Additional Considerations ................................................................................................................ 3-1

vi

1 Introduction

1.1 Conformance Demonstration Template Overview


This Conformance Demonstration Template can be used to demonstrate conformance with the
parts of ISO 26262-6/8, IEC 61508-3, or EN 50128 covered in the document
Simulink Test Reference Workflow
To access the reference workflow document, on the MATLAB command line, type
certkitiec to open the Artifacts Explorer. The reference workflow document is in Simulink
Test.
For each technique or measure:

In the third column, state to what degree you applied the technique or measure for the
application under consideration by using one of the phrases: Used, Used to a limited degree,
or Not used.

In the fourth column, state how you used the technique or measure in the application under
consideration. If the reference workflow includes alternative means for compliance, indicate
what variant you used. In addition, enter a reference to the document (for example, test
report or review documentation).

1-2

1.2 Application Identification


Applicant:

<Insert information>

Application:

<Insert information>

1-3

1-4

2 Verification and Testing of


Simulink Models and Code

Checklist 1: Verification and Testing of Simulink Models and Code

Technique / Measure

Associated
Requirements

Development of Requirementsbased test cases and expected


results

Development of test
cases and expected
results from
requirements,
independent of the model
under test and the test
environment

See measure [SLTEST_M1] in


the Simulink Test Reference
Workflow.

Used / Used to
a limited degree
/ Not used

Interpretation in
this application,
Evidence

Development of test
procedures
Review of test cases,
procedures, and expected
results
2

Execution of test cases and


procedures

Execution of test cases


and procedures on the
model

See use cases [SLTEST_UC1]


and [SLTEST_UC2] in the
Simulink Test Reference
Workflow.

Execution of test cases


and procedures on the
generated code

Assessment of test results

Comparison of test
results to expected results

See use case [SLTEST_UC3]


in the Simulink Test Reference
Workflow.

Review of failed test


cases

Generation of test reports

Generation of test reports


with Simulink Test

See use case [SLTEST_UC4]


in the Simulink Test Reference
Workflow.

Review of test report


Justification of failed test
cases
Archival of test report

2-2

Technique / Measure

Associated
Requirements

Identification of traceability
between requirements and tests
cases

Establish traceability
links between
requirements and test
cases using Simulink Test

See use case [SLTEST_UC5]


in the Simulink Test Reference
Workflow.

Review traceability

Used / Used to
a limited degree
/ Not used

Interpretation in
this application,
Evidence

2-3

3 Additional Considerations

Checklist 2: Additional Considerations

Technique / Measure

Associated Requirements

Configuration management

Configuration management for


artifacts to be verified or
tested

See measure [SLTEST_M3]


in the Simulink Test
Reference Workflow

Training of users can be


performed to ensure correct
usage of tool

See measure [SLTEST_M5]


in the Simulink Test
Reference Workflow

Evidence that coding and


verification/testing activities
are conducted by independent
roles (if applicable)

Integrity checks of tool


installation

Re-running the validation


Simulink Test test suite
provided with the IEC
Certification Kit

Analysis of available bug


report information
See measure [SLTEST_M6]
in the Simulink Test
Reference Workflow

Interpretation in
this application,
Evidence

Configuration management for


artifacts produced by the tool
(test reports)

Competency of the project


team

See measure [SLTEST_M2]


in the Simulink Test
Reference Workflow

Used / Used
to a limited
degree / Not
used

Summary validation report


generated by the Simulink
Test test suite
Assessment of bug report
information provided by tool
vendors and compliance with
recommendations and
workarounds (during
development and after
deployment)
Reporting of issues with
MathWorks products

10

Input data integrity checks


See measure [SLTEST_M4]
in the Simulink Test
Reference Workflow

Simulink Test verifies the


integrity of input files using
checksum

3-2

Technique / Measure

Associated Requirements

11

Deviation from the


reference workflow

Documentation and
justification for deviations
from the reference workflow
by using a deviation
procedure, if applicable

12

Integration with the


software safety life cycle

Documented software safety


lifecycle, including
application-specific
verification and validation
activities