Eocr Total en
Eocr Total en
General Information
Company History
1981
1988
1990
1990
1993
1994
1995
1996
1997
1997
1997
1999
2001
2002
Total
Quality
Customers
Satisfaction
Domestic Awards
1985
1986
1989
1990
1991
1994
1995
1998
1999
International Awards
1989
1990
1992
1993
1998
Approved by BM TRADA(U.K)
Approved Date 1995. 8. 30
Approved
UL
CE
ABS
SEV
KR
CCS
TV
CSA
RINA
Underwriters
Laboratories
Inc
Community
European
American
Bureau of
Shipping
Association
Suisse Des
Electriciens
Korean
Register of
Shipping
China
Classification
Society
TV
Germany
Canadian
Standards
Association
Registro
Italiano
Navale
Intellectual Property
Item
Patent
Utility Model
Design
Trade Mark
Total
Domestic
Register Applied for
29
20
25
34
108
6
7
0
11
24
Overseas
No
35
27
25
45
132
5
0
0
14
19
0
0
0
3
3
No
5
0
0
17
22
Total
40
27
25
62
154
0.5 ~ 6
0.25 ~ 30
0.17 ~ 20
0.12 ~ 1.50
0.10 ~ 1.20
Looping Option
Time of Passing
(#)
1
2
3
4
5
Option-2. External Current Transformer Option (Ext. CT option protect bigger current)
Ordering option - 05 type of each model fitted to an external current transformer can
achieve higher ampere ranges.
No. of Loops
(#)
0 Fig 1
1 Fig 2
2
3
4
Straight-through-Wiring
Fig 1
Fig 2
05 Type
60 Type
Ext. CT Option
Current Setting
Range(A)
Current Ratio
of Ext. CT
0.5 ~ 600
5.0 ~ 600
10 ~ 120
15 ~ 180
20 ~ 240
30 ~ 360
NIL
NIL
100 : 5
150 : 5
200 : 5
300 : 5
AC220(V)
kW
HP
0.75
1
5.5
7.5
22
30
37
50
55
75
95
125
110
150
150
200
Current
(A)
4.2 / 3.6
49 / 46
84 / 73
163 / 141
263 / 227
376 / 325
423 / 390
602 / 520
TYPE
05
60
100:05
200:05
300:05
400:05
500:05
600:05
Cable Size
Allowable
Thickness
( )
Current(A)
3.5
28
5.5~14
67
38
130
100
240
250
430
325
495
400
565
500
625
Remark
Overview
D-TIME(Delay Time):
When starting the motor, it s current is increasing 5 to 8 times of rated current and its starting time
is different according to the load of motors. D-Time knob(Mode) has a function to delay
the trip during starting period even if starting current exceeds over preset over-current value.
RESET
Depressing the RESET button or interrupting power supply resets the relay immediately.
Depress the RESET button on the facia for manual reset. Electrical Reset can be achieved by
interrupting power supply in remote area. Auto Reset can be achieved automatically
according to R-Time setting. Auto reset function is selectable by using mode switch.
EOCR with fixed auto reset time or adjustable auto reset time is applicable.
TEST
It has function to check and confirm the status of the motor by depressing the TEST button on the facia.
To keep depressing the TEST button makes relay trip after the elapse of D-Time and/or O-Time.
Once TEST is done, then reset the relay by depressing RESET button.
The test function of Digital EOCR with 7 Segment Display cannot be performed during motor running,
but possible when motor is stopped.
In all case, the failure of the control voltage may not interrupt the process.
It is selectable by DIP switch or FS Mode
Caution)
Caution) NVR function is designed to offer more accurate protection for motor. The motor
can not start in case there is no power supply to EOCR or the span of life of
motor is gone through. It is able to find the problem in its process in advance.
Digital EOCR
Classfication
EOCR-3DE Series
EOCR-3M Series
Model
Model
Wiring
Mount
Protection
3DE
3EZ
3DM
3MS
3MZ
3M42
Wire-through
Terminal
Flush Mounting
Panel Mounting
Basic Type
Overcurrent
Use external CT
0.5~60A
Undercurrent
Locked Running
Rotor Starting
1~960A(10:5~800:5)
1~960A(10:5~800:5)
0.5, 1~10sec
1~10sec
Phase Loss
Within 3sec
Within 3sec
Phase Reversal
Phase Unbalance
Ground Fault
Short Circuit
0.1~0.3sec
0.1sec
Within 8sec
Within 8sec
Alert Output
Trip Cause Memory
Trip Cause Display
Contacts
Rating
A:0.02~3A, B:0.2~10A
A:0.03~2.5A, B:0.2~10A
0.05sec
A/F/H/U
A/F/H
4~20m
-
Mode
5-Digit 7segment
Button SW.
O.L:2-SPST(1a1b)
O.L:1-SPST(1a)
O.L:2-SPST(1a1b)
O.L:2-SPST(1a1b)
O.L:1-SPST(1a)
AL:1-SPST(1a)
GR:1-SPST(1a)
AL:1-SPST(1a)
S.C:1-SPST(1a)
GR:1-SPST(1a)
Rating
4-Digit 7segment
Display
Running Time Memory & Setting
Bar-Graph
Current Signal Output
Setting SW. Type
Ground Fault Current Sensing
15%, 110VAC
15%
24VAC/DC, 85~250VAC/DC
The same diameter of Digital Ammeter to conventional Analogue Ammeter makes it easier for installation.
- Ammeter Selector S/W is not necessary as 3 phase current is displayed L1, L2, L3 in order every 5 seconds.
- It is easy to install Ammeter by using cap cover and it saves install time.
O.L:2-SPST
3A/250VAC, Resistive
3A/250VAC, Resistive
24VAC/DC, 220VAC
05: 05~10A, 6
EO
MC
Re
Ov
Un
Tim
- 0.5
UC
OFF
Dig
/ Tri
Tri
Ma
Th
Fit
Re
EOCR-P Seri
Terminal
Terminal
20
FDE
FEZ
FDM
FMS
FMZ
FM420
(Display)
(Display)
(Display)
(Display)
(Display)
(Display)
(Converter)
(Converter)
(Converter)
(Converter)
(Converter)
(Converter)
0.5~60A
60: 5~70A
PMZ
05~60A
1~3600A(10:5~300
1~960A(10:5~800:5)
1~960A(10:5~800:5)
0.5, 1~10sec
1~10sec
OFF/0.1~10sec/Adju
Within 3sec
Within 3sec
0.1~0.3sec
0.1sec
0.1~0.3sec
Within 8sec
Within 8sec
Within 8sec
Within 3sec
A:0.02~3A, B:0.2~10A
A:0.03~2.5A, B:0.5~10A
0.05sec
A/F/H/U
A/F/H
5-Digit
5-Digit
4-Digit 7segment
-
mA
T(1a1b)
EOCR-FM Series
4~20mA
4~20mA
Button SW.
Button SW.
-
O.L:2-SPST(1a1b)
O.L:1-SPST(1a1b)
O.L:2-SPST(1a1b)
O.L:2-SPST(1a)
O.L:1-SPST(1a)
O.L:2-SPST(1a1b)
OL/SH : 2-SPST(1a
AL:1-SPST(1a)
GR:1-SPST(1a)
AL:1-SPST(1a)
SC:1-SPST(1a)
GR:1-SPST(1a)
3A/250VAC, Resistive
3A/250VAC, Resistive
24VAC/DC, 220VAC
15%, 110VAC
24VAC/DC, 85~250VAC/DC
15%
OCR-3DE/FDE
CU Based
eal Time Processing / Higher Precision
vercurrent Protection Range: 0.5~60A, Wide Range Protection (Use with external CT from 11 to 960A, Direct application without CT up to 60A)
ndercurrent Protection Range: 0.5~59A / OFF (Use with external CT less than 960A)
me Characteristic for Overcurrent
5~10A : Definite / Inverse Selectable, Over 11A : Definite(Use with external CT in case using Inverse time)
UC output is used as common to OC output. When choosing U in ALo mode, AL mode becomes
F(--) and AL output ( 07-08 ) is transferred into Undercurrent (UC) output mode automatically.
gital display / 3 Phase Current Display: Digital Ammeter (Every 5 seconds)
ipped Cause Digital Display: Easy Troubleshooting
ip Cause Memory: Last 3 trip check function. Possible to check with tripped trip cause and current
anual / Electrical Reset
he tripping relay is normally energized with control power supply. (Selectable)
t to a variety of environment as Terminal & Window type.
esistive Strengthened against variable freguency device such as inverter : 20~400Hz.
GR : 1-SPST(1a
3A/250VAC, Resis
24VAC/DC, 85~250VA
erload Relay
EOCR-SSD
Series
PFZ
(Display)
(Converter)
Protection
Protective Item
Over-current
Phase Loss
Locked Rotor
Trip Time
O-Time
3sec
0.5sec after elapse dt
Description
Is In
[(MAX - MIN) / MAX] 100 90
3times OC setting value
A
5~3000:5)
set O.C / OFF
/Adjustable
Specification
Over-current Setting
Current
fter D-Time
sec
sec
sec
nverse: 0.03~1A
5sec
-
Reset
Operating t-c characteristic
Tolerance
Over-current
Current
Time
Operation
Store
Cause
Environment
05
30
60
D-Time
O-Time
Temperature
Humidity
Control Power
mA
SW.
Current
ST(1a1b)
ST(1a)
Resistive
Contact Rating
Insulation
Dielectric Strenghth
250VAC/DC
2-SPST
Between casing and circuit
Between casing and circuit
Between open contacts
between circuit
Installation
0.5 ~ 6A
3 ~ 30A
10 ~ 60A
1 ~ 30sec
0.5, 1 ~ 10sec
Manual / Electrical
Definite
I<1A : 0.05A, I 1A : 5%
t 3S : 0.2s, t>3s : 5%
-20 ~60
-30 ~80
30~85% RH non-condensing
110 : 110VAC 15%, 50/60Hz
220 : 220VAC 15%, 50/60Hz
440 : 440VAC 15%, 50/60Hz
24 : 240VAC DC
3A / 250VAC , Resistive
Over 10 , DC500V
2000VAC 60Hz, 1min
1000VAC 60Hz, 1min
2000VAC 60Hz, 1min
35mm Din Rail or Panel Mounting
EOCR-SS
Looping Option
Some motor size may require only one-third or one-fourth
of particular EOCR current range. These installations can
be accommodated by looping the motor wire 2 or 3 times
through the integral current transformers of the EOCR.
This reduces the number and type of relays inventoried for
spare purposes. Each additional loop will increase the
current measured as indicated by the following chart.
No. of Loops Time of Passing Current Set. Range(A)
1
0.50 - 6.0A
0
2
0.25 - 3.0A
1
3
0.17 - 2.0A
Looping
2
4
0.12 - 1.5A
Option
3
5
0.10 - 1.2A
4
05 Type
Over-current Protection
Over-current protection is provided by tripping
the relay when motor operating current (In)
exceeds over-current setting (Is) of EOCR for a
period greater than the preset operating time
(O-Time).
Protection
Straight-through-Wiring
Looping Option(1-Loop)
External CT Option
Protective Item
Over-current
Phase Loss
Locked Rotor
Specification
Current Setting
Type
05
30
60
100~ (over 60A)
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage 24
(50/60Hz)
220
440
Contact Rating Mode
Rating
Status
Time-Current Characteristic
Operating (Trip) Indication
Mount
Typical Wiring
Range
0.5 - 6A
3 - 30A
5 - 60A
Ext. CT Option
0.2 - 30 sec
0.2 - 10 sec
24VAC/DC
90 - 260VAC
320 - 480VAC
1-SPDT(1C)
3A/250VAC Resistive
Normally Energized
Definite
2-LED
35mm Din-rail / Panel
EOCR-DS
Protection
Protective Item
Over-current
Phase Loss
Locked Rotor
Type
05
30
60
100~ (over 60A)
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage 24
(50/60Hz)
220
440
Contact Rating Mode
Rating
Status
Time-Current Characteristic
Operating (Trip) Indication
Mount
Typical Wiring
Specification
Current Setting
EOCR-SP
Protective Item
Over-current
Phase Loss
Locked Rotor
Protection
Operating (Trip) Time
O-TIME
O-TIME
O-TIME + D-TIME
Specification
Range
0.5 - 6A
3 - 30A
5 - 60A
Ext. CT Option
0.2 - 30 sec
0.2 - 120 sec
24VAC/DC
90 - 260VAC
320 - 480VAC
1-SPDT(1C)
3A/250VAC Resistive
Normally Energized
Definite
LED
35mm Din-rail / Panel
Current Setting
Type
05
30
60
100~ (over 60A)
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage 24
(50/60Hz)
220
440
Contact Rating Mode
Rating
Status
Time-Current Characteristic
Operating (Trip) Indication
Mount
Typical Wiring
Protective Item
Over-current
Phase Loss
Locked Rotor
Specification
Range
0.5 - 6A
3 - 30A
5 - 60A
Ext. CT Option
0.2 - 30 sec
0.2 - 10 sec
24VAC/DC
90 - 260VAC
320 - 480VAC
2-SPST
3A/250VAC Resistive
Normally Energized
Definite
2-LED
35mm Din-rail / Panel
Current Setting
Type
01
10
20
Trip Time Setting O-TIME
Control Voltage 24
(50/60Hz)
220
440
Contact Rating Mode
Rating
Status
Time-Current Characteristic
Operating (Trip) Indication
Mount
Range
0.3 - 2A
1 - 12A
5 - 25A
0.5 - 15 sec
24VAC/DC
90 - 260VAC
320 - 480VAC
1-SPDT(1C)
3A/250VAC Resistive
Normally Energized
Definite
2-LED
Contactor Mounted
Typical Wiring
EOCR-SS / SP / DS Series
Features
Compact Design
MCU Based
Multiple Protection Functions
Wide Current Adjustment Range (10:1)
Ammeter Function & Trip Indication
Easy Troubleshooting & Run Monitor
Manual Instantaneous / Electrical Remote Reset
Test Function
Ambient Insensitive
Fail-safe Operation
EOCR-SS1 / SS2
Protection
Protective Item
Over-current
Phase Loss
Locked Rotor
Time Characteristic
SS2
O-TIME
4 sec
D-TIME
Definite
Specification
Time-Current Characteristic Curve
EOCR
Current Setting
05
30
60
100~ (over 60A)
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage
24
(50/60Hz)
110
220
Contact Rating
X1 Mode & Rating
Status
X2 Mode & Rating
Status
Time-Current Characteristic
Trip & Trip Cause Indication
Mount
Typical Wiring
SS1
SS2
0.5 - 6A
0.5 - 6A
3 - 30A
3 - 30A
5 - 60A
External CT Option
0 - 50 sec
1 - 50 sec
1 - 10
0.2 - 10 sec
24VAC/DC
85 - 150VAC
180 - 260VAC
1-SPST, 3A/250VAC Resistive
Normally Energized
1-SPDT, 3A/250VAC Resistive
Normally De-energized
Inverse
Definite
2-LED
35mm Din-rail
EOCR-SP1 / SP2
Protection
Protective Item
Over-current
Phase Loss
Locked Rotor
Phase Reversal
Time Characteristic
Protection
EOCR Operating (Trip) Time
DS2(T)
DS1(T)
DS3(T)
O-TIME
O-TIME(curve)
O-TIME
4 sec
4 sec
4 sec
D-TIME
D-TIME
D-TIME
0.1sec
Definite
Inverse
Definite
Specification
EOCR
Current Setting
05
30
60
100~ (over 60A)
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage
24
(50/60Hz)
110
220
Contact Rating
Mode
Rating
Status
Time-Current Characteristic
Trip & Trip Cause Indication
Mount
Typical Wiring
Protective Item
Over-current
Phase Loss
Locked Rotor
Time Characteristic
Specification
DS1(T)
0.5 - 6A
3 - 30A
-
DS2(T)
DS3(T)
0.5 - 6A
3 - 30A
5 - 60A
External CT Option
0 - 50 sec
1 - 50 sec
1 - 10
0.2 - 10 sec
24VAC/DC
85 - 150VAC
180 - 260VAC
2-SPST
3A/250VAC Resistive
Normally Energized
Inverse
Definite
Definite
2-LED
35mm Din-rail
EOCR
Current Setting
01
10
20
Time
Start D-TIME
Setting
Trip
O-TIME
Control Voltage
24
(50/60Hz)
110
220
Contact Rating
Mode
Rating
Status
Time-Current Characteristic
Trip & Trip Cause Indication
Mount
SP1
0.3 - 1.2A
1 - 12A
5 - 25A
10 sec(Fixed)
1 - 10
SP2
03 - 1.2A
1 - 12A
5 - 25A
1 - 50 sec
5 sec(Fixed)
24VAC/DC
85 - 150VAC
180 - 260VAC
2-SPST
3A/250VAC Resistive
Normally Energized
Inverse
Definite
2-LED
Contactor Mounted
Typical Wiring
EOCR-3DE/FDE Series
Features
Compact Design
3DE/3EZ : Panel Mounting Type
FDE/FEZ : Panel Flush Mounting Type
MCU(Microprocessor Control Unit) Based
3 Integral Current Transformers
Multiple Protection Functions
Digital Ammeter
Troubleshooting / Trip Cause Memory, Display
Adjustable Operating Features by Mode switch
Wide Current Adjustment Range
Selectable Time-Current Characteristics (Inverse / Definite)
Manual (Instantaneous) / Electrical (Remote) Reset
Test Function
Ambient Insensitive
Selectable Fail-safe and Non-fail-safe Operation Modes
Comparison Table of Model
3DE / FDE
EOCR
Protection
Over - current
Under - current
Phase Loss
Phase Unbalance
Phase Reverse
Locked Rotor
Ground Fault
Run Monitor & Load Alert Function
Selectable Alerting Pulse
3EZ / FEZ
1
2
3
4
5
0
1
2
3
4
Looping
Option
0.5 - 6
0.25 - 3
0.17 - 2
0.12 - 1.5
0.1 - 1.2
External CT Option
Higher ampere ranges can be achieved by setting in CT mode fitted
to an external current transformer, and the actual motor current display
is possible in any case
Type
Value in
CT mode
Current Setting
Range (A)
wide Range
10 : 5
15 : 5
OFF(--)
10
15
0.5 ~ 60A
1 ~ 12A
1.5 ~ 18A
800 : 5
800
80 ~ 960A
EOCR-3DE+External CT
Alert Function
-
Protection Feature
Function
Looping Option
Description
This is provided by the relay tripping when motor
operating current(In) exceeds current setting value in
oc mode for a period greater than the preset trip
time(O-Time in ot mode)(Curve-2)
Over-current tc
This is provided by the relay tripping when motor
In
(Inverse operating current(In) exceeds current setting value in
oc mode according to the Time-current Characteristic
T-C)
Curve(Curve-1)
This is provided by the relay tripping when motor
Definite operating current(In) is lower than current setting value
Under-current Uc
in uc mode for a perid greater than the preset trip
T-C
time(Time in ut mode)
mode
dE
(Definite
T-C)
When motor operating current (In) exceeds the alert setting (As), the
alert relay outputs three kind of signal. The output can be used to warn
customers/operators of possible overloading and avoid unnecessary
motor shutdown.
The type of output signal is decided by the selection in the Alo mode
A(Ampere relay): energized whenever CT senses a current
F(Flickering): characterA and current value flashs frequently
H(Holding): ON-OFF
U(Undercurrent mode): the AL output(07
08) is transferred into
Uc output
Running state
More then
preset(%) of Alert
Normal
SettingALo
Trip
FlickerF
HoleH
2 sec
AuxA
The relay will be operated within 3 sec.
When the phase failure occurs
Phase Loss
PL
Phase
Unbalance
On
Phase
Reversal
Ground
Fault
Locked
Rotor
Stall
10
95
96
97
98
95
96
(Non-Fail safe) 97
98
FS:ON
(Fail safe)
FS-(OFF)
Ralay Trip
Digital Ammeter
3 phase motor currents (In) / Ground fault current are displayed in
sequence on the LED display.
3DE/FDE
3EZ/FEZ
O-T Setting
IEC 947-4
(Curve)
(Trip Class)
1-5
10A
6-10
10
11-20
20
21-30
30
Test
This is the self-test of this product. If the relay enters into this mode, it
begins to count down preset value of O-time after waitng 3sec and
becomes trip state as showing END message that means this relay is
ready to work.
- END message of this test is also stored in Fault mode as last trip.
- Not permitted to test this function during the operation to prevent
unnecessary trip
Reset
Depressing the RESET button or interrupting control power resets the
relay immediately. Electrical remote reset is also available through the
panel mounted reset switch.
11
EOCR-3DE/3EZ
MCU Based
3 Integral Current Transformers
Over-current, Under-Current, Phase Loss, Phase
Unbalance, Phase Reversal, Locked Rotor Protection
Digital Ammeter & Trip cause indication
Selectable Trip Time-Current Characteristics
Independently Adjustable Starting Trip Delay and
Operating Trip Time
+ Load Alerting Function
EOCR-3DE
+ Ground Fault Protection EOCR-3EZ
EOCR-3DE / 3EZ
Protection
Typical Wiring
EOCR-3DE
Protective Item
Over-current
Under-current
Phase Loss
Phase Unbalance
Phase Reversal
Locked Rotor
-
EOCR-3EZ
Trip Time
O-TIME
0.5~30 sec
3 sec
8 sec
0.1~0.3 sec
D-TIME
-
Protective Item
Over-current
Under-current
Phase Loss
Phase Unbalance
Phase Reversal
Locked Rotor
Ground Fault
Trip Time
O-TIME
0.5~30 sec
3 sec
8 sec
0.1~0.3 sec
D-TIME
0.05~10 sec
Specification
Model
Over Current Setting Range
Ground Fault Current Setting
Alert Setting
Start Delay Time Setting (D-TIME)
Trip Delay Time Setting (O-TIME) INV
DEF
Control Voltage
Contact Rating
OL
AL/GR
Rating
Time Characteristic
In/tcmode
dE/tcmode
Troubleshooting / Trip Indication
Current Sensing
Mounting
EOCR-3DE
EOCR-3EZ
Refer Table #1
50 ~ 100% / OFF
A: 0.02 ~ 3A / B: 0.2~10A
-
1 ~ 200 sec
1 ~ 30
0.2 ~ 30 sec
24VAC/DC, 110VAC 15%, 220VAC 15%
2-SPST
1-SPST
AL Relay
Ground Fault Relay
3A/250VAC Resistive
Inverse (See Curve-1)
Definite (See Curve-2)
LED Display (SSD+LED)
3-CT
35mm Din-rail
EOCR-3DE
12
Number of Conductors
thru CT windows
1
2
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Extermal CT Ratio
Setting of CT Ratio
Remark
10 : 5
15 : 5
20 : 5
25 : 5
30 : 5
40 : 5
50 : 5
60 : 5
75 : 5
100 : 5
120 : 5
150 : 5
200 : 5
250 : 5
300 : 5
400 : 5
500 : 5
600 : 5
750 : 5
800 : 5
OFF(Mode : --)
2t
5t
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
400
500
600
750
800
Wide Range
EOCR-3EZ
Tolerance(3DD/ 3DZ / FD / FDZ / PMZ / SSD)
Current
Time
I<1A :
I 1A :
0.05A
5%
Caution
The extermal CT should be used in case Inverse curve(toln setting)
is applied over 10Amps.
EOCR-FDE/FEZ
EOCR-FDE / FEZ
Protection
Typical Wiring
EOCR-FDE
Protective Item
Over-current
Under-current
Phase Loss
Phase Unbalancal
Phase Reverse
Locked Rotor
-
EOCR-FEZ
Trip Time
O-TIME
0.5~30 sec
3 sec
8 sec
0.1~0.3 sec
D-TIME
-
Protective Item
Over-current
Under-current
Phase Loss
Phase Unbalancal
Phase Reverse
Locked Rotor
Ground Fault
Trip Time
O-TIME
0.5~30
3 sec
8 sec
0.1~0.3 sec
D-TIME
0.05~10 sec
Specification
Model
Over Current Setting
Ground Fault Current Setting
Alert Setting
Start Time Setting (D-TIME)
Trip Time Setting (O-TIME)
EOCR-FDE
50 ~ 100% / OFF
INV
DEF
Control Voltage
Contact Rating
OL
AL/GR
Rating
In/tcmode
dE/tcmode
Time Characteristic
Troubleshooting / Trip Indication
Current Sensing
Mounting
Caution
EOCR-FEZ
Refer Table #1
: 0.02 ~ 3A / B: 0.2~10A
-
1 ~ 200 sec
1 ~ 30
0.2 ~ 30 sec
24VAC/DC, 110VAC 15%, 220VAC 15%
2-SPST
1-SPST
AL Relay
Ground Fault Relay
3A/250VAC Resistive
Inverse (See Curve-1)
Definite (See Curve-2)
LED Display (SSD+LED)
3-CT
35mm Din-rail
EOCR-FDE
The extermal CT should be used in case Inverse curve(tc ln setting) is applied over 10Amps.
How to set
Mode
DN
SET
store
Set
Adjust
UP
DN
UP
Store
SET
store
Reset
RESET
EOCR-FEZ
13
EOCR-3DM/FDM Series
Features
Compact Design
3DM : Panel Mounting Type
FDM : Flush Mounting Type
MCU(Microprocessor Control Unit) & ASIC Based
3 Integral Current Transformers
Multiple Protection Functions
Digital Ammeter
Troubleshooting / Trip Cause Memory, Display
Adjustable Operating Features by Pulse Rotary switch
Wide Current Adjustment Range
Selectable Time-Current Characteristics (Inverse / Definite)
Manual Instantaneous / Electrical Remote Auto Reset
Test Function
Ambient Insensitive
Selectable Fail-safe and Non-fail-safe Operation Modes
Normal
(operation)
SettingALo
FlickerF
HoleH
3sec
AuxA
3DM / FDM
Over - current
Under - current
Phase Loss
Phase Unbalance
Phase Reverse
Locked Rotor
Ground Fault
Run Monitor & Load Alert Function
Selectable Alerting Pulse
More then
preset(%) of Alert
3MZ / FMZ
Protection Feature
Function DIP Switch
Over
current
Under
current
Control power on
Description
DEF
sw#3 on
INV
sw#3 off
96
97
98
95
96
(Non-Fail safe) 97
98
FS-(OFF)
Phase
Loss
Phase
Unbalance
Phase
Reversal
Ground
Fault
A Type:
0.03-2.5A
B Type :
0.5-10A
Locked
Rotor
Stall
14
95
FS:ON
(Fail safe)
Ralay Trip
Time
I<1A :
I 1A :
0.1A
5%
Trip
EOCR-3DM/FDM Series
LED Display
Digital Ammeter
3 phase motor currents (In) are displayed in sequence on the LED display.
3DM/FDM
3MZ/FMZ
MODE
Set
Adjust
Store
Reset
Pushing the RESET button or interrupting power resets the relay
immediately. Electrical remote reset is also available through the
panel mounted reset switch. The relay cannot be reset by control
power interruption when the hand reset (H-r) selected in mode.
In this case, it is possible to press the reset button on the relay facia.
Automatic reset is also available if enter into reset mode (rt:A-r) and
reset delay time is adjustable from 0.3sec to 20min
15
EOCR-3DM/3MS/3MZ/3M420
Protection
Trip Time
Protective Item
Over-current
Under-Current
Phase loss
Phase reversal
Phase Unbalance
Locked Roter
Lock
stall
Ground fault
Short circuit
3DM
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
-
3MS
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
0.05sec
3MZ
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
0.1 ~ 10sec
-
3M420
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
-
3DM
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
24VAC/DC
85 ~ 250VAC/DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
1-SPST(AL)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
3MS
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
0.05sec
24VAC/DC
85 ~ 250VAC/DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
1-SPST(S.C)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
3MZ
Refer to, Table #1
0.5 ~ under OC setting
A : 0.03 ~ 2.5A / B : 0.5 ~ 10A
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
0.1 ~ 10sec
24VAC/DC
85 ~ 250VAC/DC, 50/60Hz
1-SPST, 3A/250VAC, Resistive
1-SPST(GR)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
3M420
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
24VAC/DC
85 ~ 250VAC/DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
35mm Din-rail
35mm Din-rail
35mm Din-rail
35mm Din-rail
Specification
Model
Current Setting
Range
Time Setting
Short circuit
Control Power
Contact Rating
Environment
Over-Current(oc)
Under-Current(uc)
Ground Fault Current(Ec)
Starting Delay T ime(dt)
Over-Current Trip Delay(ot)
Under-Current Trip Delay(ut)
Ground Fault Trip Delay(Et)
24
220
OL
AL(GR/SC)
Temperature
Store
Operation
Humidity
7-Segment LEDs
Bar-Graph
Display
Mounting
16
Naumber of Conductord
thru CT windows
5
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
External CT ratio
05
05
05
60
20
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
05
NIL
NIL
NIL
NIL
NIL
10 : 5
15 : 5
20 : 5
25 : 5
30 : 5
40 : 5
50 : 5
60 : 5
75 : 5
100 : 5
120 : 5
150 : 5
200 : 5
250 : 5
300 : 5
400 : 5
500 : 5
600 : 5
750 : 5
800 : 5
Setting of CT Mode
Remark
5t
5t
05
60
20
10
15
20
25
30
40
50
60
75
100
120
150
200
250
300
400
500
600
750
800
EOCR-FDM/FMS/FMZ/FM420
Protection
Trip Time
Protective Item
Over-current
Under-Current
Phase loss
Phase reversal
Phase Unbalance
Locked Roter
Lock
stall
Ground fault
Short circuit
FDM
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
-
FMS
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
0.05sec
FMZ
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
0.1 ~ 10sec
-
FM420
DEF: 0.2 ~ 30sec, INV: 1 ~ 30
0.5 ~ 30sec(DEF)
3sec
0.1sec
8sec
0.5sec after dt
1 ~ 10sec
-
FDM
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
24VAC/DC
85 ~ 250VAC/ DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
1-SPST(AL)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
FMS
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
0.05sec
24VAC/DC
85 ~ 250VAC/ DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
1-SPST(S.C)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
FMZ
Refer to, Table #1
0.5 ~ under OC setting
A : 0.03 ~ 2.5A / B : 0.5 ~ 10A
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
0.1 ~ 10sec
24VAC/DC
85 ~ 250VAC/ DC, 50/60Hz
1-SPST, 3A/250VAC, Resistive
1-SPST(GR)
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
FM420
Refer to, Table #1
0.5 ~ under OC setting
OFF ~ 200sec
DEF : 0.2 ~ 30sec / INV : 1 ~ 30
0.5 ~ 30sec(DEF)
24VAC/DC
85 ~ 250VAC/ DC, 50/60Hz
2-SPST, 3A/250VAC, Resistive
-30 ~ 80
-20 ~ 60
30 ~ 85RH, Without condensation
35mm Din-rail
35mm Din-rail
35mm Din-rail
35mm Din-rail
Specification
Model
Current Setting
Range
Time Setting
Short circuit
Control Power
Contact Rating
Environment
Display
Mounting
Over-Current(oc)
Under-Current(uc)
Ground Fault Current(Ec)
Starting Delay T ime(dt)
Over-Current Trip Delay(ot)
Under-Current Trip Delay(ut)
Ground Fault Trip Delay(Et)
24
220
OL
AL(GR/SC)
Temperature
Store
Operation
Humidity
7-Segment LEDs
Bar-Graph
17
EOCR-FDM/FMS/FMZ/FM420
Typical Wiring
18
EOCR-3DM
EOCR-FDM
EOCR-3MS
EOCR-FMS
EOCR-3MZ
EOCR-FMZ
EOCR-3M420
EOCR-FM420
EOCR-M1 Series
Features
MCU(Microprocessor Control Unit) Based
Convenient installation
- PMZ : Panel Mounting Type
- PFZ : Panel Flush Mounting Type
Easy to set
3 Integral Current Transformers
Multiple Protection Functions
Wide range protection from 0.1A to 3600A by just 1 model
Built-in digital ammeter
Total running time display
Current display like L1 L2 L3 GF
Bar-Graph monitoring on impending overload trip
Selectable time-current characteristics [Inverse / Inverse based on
thermal Memory(Thermal Inverse) / Definite]
4~20mA current loop communcations
Test function
Selectable Fail-safe operation / No volt Release (FS : ON)
Operates in wide ambient temperature range
Looping Option
Smaller ampere ranges than particular EOCR current range can be
covered by looping the motor wire 2 or 3 times as under described.
No of Loops Current Ratio Current Setting
of Ext. CT
Range (A)
0.5 Type
Looping
Option
0
1
2
3
4
1
2
3
4
5
0.5 - 10
0.25 - 6
0.17 - 3.3
0.12 - 2.5
0.1 - 2
Protection Feature
Function
Description
When the motor operating current(In) exceeds preset oc
setting, the relay will trip after preset O-Time in ot setting
The amperage of In(operating current) will not effoet relay
trip time.
Otc:dE
Selection
Curve-2
Otc:In
Selection
Curve-1
Otc:th
UnderCurrent
Definite
time
Phase
Loss
PL:on
Selection
Phase
Unbalance
The relay operates within 8sec. when the current diffenence Ub:6
shows 6%
among 3phases is greater than preset % of unbalance.
selected
The calculation formula is (Max-Min)/Max current 100
Phase
Reversal
Ground
Fault
Definite
0.03-10A
Locked
Rotor
Disable on
inverse
charateristic
Disable on
inverse
charateristic
OverCurrent
PMZ
FMZ
Over - current
Under - current
Short - current
Phase Loss
Phase Unbalance
Phase Reverse
Locked Rotor
Ground Fault
Current output 4~20mA
External CT Option
Higher ampere ranges can be achieved by setting CT Ratio in ct
mode to take an external current transformer, and the actual motor
current display can be provided
Current Setting Range Number of Conductors
Extermal CT Ratio Setting of CT Ratio
(Amps)
thru CT windows
0.5 ~ 60A
1
OFF
0.25 ~ 3.0A
2
2t
0.1 ~ 1.2A
5
5t
1 ~ 12A
1
10 : 5
10
1.5 ~ 18A
1
15 : 5
15
2.0 ~ 24A
1
20 : 5
20
2.5 ~ 30A
1
25 : 5
25
3.0 ~ 36A
1
30 : 5
30
4.0 ~ 48A
1
40 : 5
40
5 ~ 60A
1
50 : 5
50
6 ~ 72A
1
60 : 5
60
7.5 ~ 90A
1
75 : 5
75
10 ~ 120A
1
100 : 5
100
12 ~ 144A
1
120 : 5
120
15 ~ 180A
1
150 : 5
150
20 ~ 240A
1
200 : 5
200
25 ~ 300A
1
250 : 5
250
30 ~ 360A
1
300 : 5
300
40 ~ 480A
1
400 : 5
400
50 ~ 600A
1
500 : 5
500
60 ~ 720A
1
600 : 5
600
75 ~ 900A
1
750 : 5
750
80 ~ 960A
1
800 : 5
800
100 ~ 1200A
1
1000 : 5
1000
120 ~ 1800A
1
1500 : 5
1500
200 ~ 3000A
1
2000 : 5
2000
250 ~ 3000A
1
2500 : 5
2500
300 ~ 3600A
1
3000 : 5
3000
Selection
Remark
Wide Range
Stall
inverse
0.03-1.0A
During
D-Time
After
D-Time
19
EOCR-M1 Series
LED Display
Digital Ammeter
3 phase motor currents (In) and ground(earth) leakage current are
displayed in sequence on the LED display.
O-T Setting
1-5
6-10
11-20
21-30
95
96
97
98
95
96
(Non-Fail safe) 97
98
FS:ON
(Fail safe)
FS-(OFF)
Ralay Trip
Test
This is the self-test of this product, checking function of sequence
after the installation. If the relay enters into this mode, it begins its
count down preset value of O-Time after waiting 3sec and
becomes trip state as showing END message that means this
relay is ready to work END message of this test is also stored in
Fault mode as last trip. While motor is running, output relay
contact is not switched to prevent unnecessary trip
Reset
It can be selected by rt:H-r, rt:E-r or rt:A-r in rt mode.
The rt means reset type and the meaning of H-r, E-r and A-r are
hand, electrical and auto reset respectively.
The relay can be reseted by depressing the reset button on relay
facia -rt:H-r, interruption of control power on A1, A2-rt:E-r and by
setting of automatic reset time from 0.2sec to 20min(indication :
20n) -rt:A-r and A:0.3
20
Curve-1 Inverse
Curve-2 Definite
Curve-3
Inverse time characteristics of EC
(Ground current range : 0.03~1A)
EOCR-PMZ
EOCR-PMZ
Protection
Protective Item
Over-current
Under-Current
Phase reversal
Phase Unbalance
Typical Wiring
Trip Time
O-TIME
Preset Ut time
0.1~0.3sec
8sec
EOCR-PMZ
Protective Item
Ground fault
Locked Rotor
Stall
Trip Time
Preset Et time
0.5sec after d-time
0.05~10sec
Specification
Model
Current Setting
Range
Time Setting
Over-Current(oc)
Under-Current(uc)
Ground Fault Current(Ec)
Tolerance
Control Power
Contacts Rating
Environment
Display
Insulation
Dielectric Strength
PMZ
Refer to current setting range( page 19 )
Off / 0.5 ~ less than oc setting
Off
0.3 ~ 10A : definite time characteristics
0.3 ~ 1A definite / inverse time characteristics, selectable
Off ~ 200sec, Adjustable
Definite Time
0.2 ~30sec
Inverse Time
1.0 ~ 30class(30curves)
0.5 ~ 30sec, definite time characteristics, if uc mode is OFF,
then OFF is displayed automatically in ut mode
Definite / Inverse : 0.05, 0.1 ~ 1 ~ 10sec(curve-3)
OFF / 1~ 10sec
5%
5%
24VAC/DC
85 ~ 250VAC/DC, 50/60Hz
2-SPST
3A / 250VAC Resistive
1-SPST
3A / 250VAC Resistive
-30 ~ 80
-20 ~ 60
30 ~ 85% RH Non-Condensing
3 Phase current, Trip cause, Operating hour
Load factor for current setting(50 ~ 100%)
Between casing and circuit : over 10 , DC500V
Between casing and circuit
2000VAC, 60Hz, 1min
Between open contacts
1000VAC, 60Hz, 1min
Between circuit
2000VAC, 60Hz, 1min
Lever 3 : Air Discharge : 8kV, Contact Discharge : 6kV
Lever 3 : 10V/m, 150MHz & 450MHz Portable transceiver
Lever 3 : 2kV, 1min
Lever 3 : 1. 50 , 4kV(0 , 90 , 180 , 270 )
Lever 3 : 2.5kV, 1MHz
Class B
21
EOCR-PFZ
EOCR-PFZ
Protection
Protective Item
Over-current
Under-Current
Phase reversal
Phase Unbalance
Typical Wiring
Trip Time
O-TIME
Preset Ut time
3sec
8sec
EOCR-PFZ
Protective Item
Short Circuit
Ground fault
Locked Rotor
Stall
Trip Time
0.03~0.05sec
Preset Et time
0.5sec after d-time
0.05~10sec
Specification
Model
Current Setting
Range
Time Setting
Over-Current(oc)
Under-Current(uc)
Ground Fault Current(Ec)
Tolerance
Control Power
Contact Rating
Environment
Display
Insulation
Dielectric Strength
22
PFZ
Refer to current setting range( page 19 )
Off / 0.5 ~ less than oc setting
Off
0.3 ~ 10A : definite time characteristics
0.3 ~ 1A definite / inverse time characteristics, selectable
Off ~ 200sec, Adjustable
Definite Time
0.2 ~30sec
Inverse Time
1.0 ~ 30class(30curves)
0.5 ~ 30sec, definite time characteristics, if uc mode is OFF,
then OFF is displayed automatically in ut mode
Definite / Inverse : 0.05, 0.1 ~ 1 ~ 10sec(curve-3)
OFF / 1~ 10sec
5%
5%
85 ~ 250VAC/DC, 50/60Hz
2-SPST
3A/250VAC Resistive
1-SPST
3A/250VAC Resistive
-30 ~ 80
-20 ~ 60
30 ~ 85% RH Non-Condensing
3 Phase current, Trip cause, Operating hour
Load factor for current setting(50 ~ 100%)
Between casing and circuit : over 10 , DC500V
Between casing and circuit
2000VAC, 60Hz, 1min
Between open contacts
1000VAC, 60Hz, 1min
Between circuit
2000VAC, 60Hz, 1min
Lever 3 : Air Discharge : 8kV, Contact Discharge : 6kV
Lever 3 : 10V/m, 150MHz & 450MHz Portable transceiver
Lever 3 : 2kV, 1min
Lever 3 : 1. 50 , 4kV(0 , 90 , 180 , 270 )
Lever 3 : 2.5kV, 1MHz
Class B
DOCR-S/H
Electronic DC Current
Features
DC Overcurrent Relay for DC Motor
The milli-volt( ) signals generated from the Shunt and power supply are
sensed by solid state circuitry and compared with preset overload setting.
In case sensing overload condition, the internal relay switches contact
after the preset delay. It has easier control operation.
It has DC Overload and DC Underload protection relays.
It has wide DC current protection range from 1A to hundreds Amps.
DC Ammeter maybe used instead of Shunt
(DC Ammeter has its own shunt inside and keep 50mV maintained.)
Features
MCU (Microprocessor Control Unit) Based
DC Motor / DC Device Protection
Sensing by Shunt (DOCR-S) / by Hall Sensor (DOCR-H)
Actual primary current is displayed after Shunt
/ Hall Sensor setting. (Indication)
Digital Setting / Tripped Current digital DATA displayed. (Indication)
Auto Reset / Reset Time Setting
Confirm Setting Current / Test Function
No Volt Release function (Fail-safe Operation) Setting ( NVR Setting)
Protection
Protection
Trip Time
Protective Item
DCL
O-TIME
-
Over-current
Undercurrent (Dry-run)
DUCR
O-TIME
Specification
Type
70
O-TIME
M
A
Voltage
220
440
Frequency
Contact Rating
Mounting
Trip Time
O-TIME(Definite)
In case the line voltage is same voltage with control voltage of DOCR-S type,
Contact our representative or our head office.
Specification
Current Setting
Indication
Power Supply
Protective Item
Over-current
N
R
Setting Range(DCL)
Setting Range(DUCR)
DC Over-current Relay
DC Under-current Relay
Secondary Voltage of Shunt (10~70m VCD)
30sec(Adjustable)
Manual(Instantaneous) / Electrical(Remote)
Auto(Instantaneous) Reset(Option)
LED
110 / 220VAC
Other Voltage(Option)
380 / 440VAC
50 / 60Hz
Normally Energized
Normally De-energized
Panel
Current Setting
O-TIME
Reset Time
Rated Shunt
Rated Hall Sensor
Power Supply
Voltage
24
220
Frequency
Reset
Contact Rating
Mode
Rating
Indication
Mounting
Typical Wiring
Setting Range
Setting Range
(DOCR/DUCR-S)
(DOCR/DUCR-H)
0.1 ~ 240A
5 ~ 360A
0.5 ~ 25sec
0.5 ~ 25sec
0.5 ~ 25sec
0.5 ~ 25sec
1A, 2A, 5A, 10A, 20A,
50A, 110A, 200A
50A, 100A, 200A, 300A
24VAC/DC
24VAC/DC
85 - 250VAC/DC
85 - 250VAC/DC
50/60Hz
Manual / Electrical / Auto Reset
1-SPDT(1C)
3A/ 250VAC Resistive
7Segment LED
Panel
Typical Wiring
EOCR-S
EOCR-H
23
EUCR
Features
Compact Design
Two Integral Current Transformers
Under-load Protection (Dry-run Protector)
Wide Current Adjustment Range
Definite Trip Time Characteristic
Manual (instantaneous) / Electrical (Remote) Reset
Ambient Insensitive
Non-fail-safe Operation
Features
Compact Design
Three Integral Current Transformers
Under-load Protection / Dry-run Protector
Wide Current Adjustment Range
Definite Trip Time Characteristic
Manual (instantaneous) / Electrical (Remote) Reset
Ambient Insensitive
Fail-safe Operation
Protection
Protection
Protective Item
Undercurrent (Dry-run)
Trip Time
O-TIME
Specification
Specification
Current Setting
Type
05
30
60
100 - 600
O-TIME
Contact Rating
Frequency
Mode
Rating
Status
Mounting
24
110
220
Setting Range
0.5 - 6A
3.0 - 30A
5.0 - 60A
05 Type fitted to External CT
(Current Ratio: 100/5A - 600/5A)
0.2 - 30 sec
Manual (Instantaneous) / Electrical (Remote)
Definite
24VAC/DC
110VAC
220VAC
50/60Hz
1-SPDT (1C)
3A/250VAC Resistive
Normally De-energized
35mm DIN-rail / Panel
Current Setting
Type
05
30
60
100 - 600
O-TIME
Contact Rating
Frequency
Mode
Rating
Status
Mounting
24
110
220
Setting Range
0.5 - 6A
3.0 - 30A
5.0 - 60A
05 Type fitted to External CT
(Current Ratio: 100/5A - 600/5A)
0.2 - 30 sec
Manual (Instantaneous) / Electrical (Remote)
Definite
24VAC/DC
110VAC
220VAC
50/60Hz
2-SPST (1a1b)
3A/250VAC Resistive
Normally Energized
35mm DIN-rail / Panel
Typical Wiring
Typical Wiring
Normally De-energized
24
Trip Time
O-TIME
Protective Item
Undercurrent (Dry-run)
Normally Energized
EVR
Features
Compact Design
Multiple Protection Functions
24 Hours Trip Cause Memory
Trip Indication & Troubleshooting
Manual / Electrical Reset
Ambient Insensitive
Ascertain Button
Protection
Trip Time
OVR-TIME
UVR-TIME
0.5 sec
0.5 sec
Specification
OVR-VOLT
UVR-VOLT
OVR-TIME
UVR-TIME
M
A
TEST
ASCERTAIN S/W
(Trip Cause Indication)
Allowable Tolerance
Typical Wiring
Protective Item
Over-voltage
Under-voltage
Phase Loss
Phase Reversal
Voltage Unbalance
Specification
Rated Voltage
Features
MCU & ASIC Based Compact Design
Multiple Protection Functions
Wide Voltage Adjustment Range
Digital Volt Meter and Digital Setting
Trip Cause Display & Easy Troubleshooting
Manual / Electrical / Automatic Reset
Adjustable Reset Timer
Ambient Insensitive
Protection
Protective Item
Over-voltage
Under-voltage
Phase Loss
Phase Reversal
Voltage Setting
EVR-FD
Voltage
Time
EVR - 220
220V
220 - 300V
160 - 220V
EVR - 380
EVR-415
380V
415V
380 - 460V
415 - 500V
300 - 380V
340 - 415V
0.5 - 2 sec
1 - 5 sec
within 0.5 sec
within 0.5 sec (after Supply Power)
Definite
1-SPDT(1C), 5A/250VAC Resistive
Manual Reset
Automatic Reset (Reset Time = 5 sec)
Trip in 1 sec (after Pushing TEST Button)
Trip Cause is memorized for 24 hours and
Trip Cause will be indicated via LED
by pushing Ascertain S/W.
5%
15%
Voltage Setting
Type
110
220
440
O-TIME
U-TIME
220
Others
Mode
Rating
Status
SW3=AUTO
SW3=MAN
Reset
Mounting
PD
FD
DCU
PCU
Typical Wiring
25
DVR
Features
Compact Design
Definite Trip Time-current Characteristic
Trip & Run Indication (LED)
Confirm actual current and precise setting possible as it has
Voltage Meter.
Solid State DC Over-voltage / Undervoltage Protection.
Features
MCU (Microprocessor Control Unit) Based
DC Motor / DC Device Protection
Separate Setting for Over-voltage and Undervoltage
Line Voltage Indicative Function (FND)
Digital Setting / Trip Cause Indication
Auto Reset / Reset Time Setting
Confirm Setting Value / TEST Function
No Volt Release Function (Fail-safe Operation) Setting
( NVR Setting)
Protection
Protection
Trip Time
Protective Item
DOVR
O-TIME
-
Over-voltage
Undervoltage
DUVR
O-TIME
Specification
Model
Voltage Setting
Mode
Status
Mounting
Typical Wiring
26
Protective Item
Over-voltage
Undervoltage
Trip Time
O-TIME
O-TIME
Specification
Type
10
30
110
220
Others
O-TIME
M
A
220
Others
1-SPDT(1C)
R Type
DC Over-voltage
DC Undervoltage
Voltage Setting Range
1 ~ 10V
3 ~ 30V
3 ~ 30V
10 ~ 110V
20 ~ 110V
20 ~ 220V
30 ~ 220V
Option
0.2 ~ 30sec
Manual(Instantaneous) / Electrical Reset
Auto (Option)
110/220VAC, 50/60Hz
Other Voltage Option
3A/250VAC Resistive
Normally De-energized
Panel
Model
Over-voltage
Undervoltage
Trip Time
Reset Time
Power Supply
Voltage
Frequency
Reset
Mounting
Typical Wiring
OVR
UVR
O-TIME
R-TIME
24
220
Setting Range
100 ~ 160VDC
60 ~ 110VDC
0.5 ~ 25sec
0.5 ~ 25sec
24VAC/DC
85 ~ 250VAC/DC
50/60Hz
Manual / Electrical / Auto Reset
35mm DIN-Rail / Panel
ELR
EFR2.5
Features
MCU Based Compact Design
Ground (Earth) Fault Protection for
Motor and Power Distribution Systems
Zero Phase Current Detection Method
Test Button Provides a Manual Self-testing Function
Independently Adjustable Ground (Earth) Current and
Trip (Operating) Delay Time
Built-in Power Indication LED and Trip Indication LED
Features
MCU Based Compact Design
Ground (Earth) Fault Protection for
Motor and Power Distribution Systems
Residual Current Distribution Method
Test Button Provides a Manual Self-testing Function
Independently Adjustable Ground (Earth) Current and
Trip (Operating) Delay Time
Built-in Power Indication LED and Trip Indication LED
Specification
Specification
Current Setting
Time Setting
Operating Characteristic
Current Sensing
Control Voltage
Frequency
Current Tolerance
Time Tolerance
Contact Rating
Rated Insulation Voltage
Expected Mechanical Life
Expected Electrical Life
Ambient Temperature
Ambient Humidity
Dielectric Strength
Electrostatic Discharge
EFT / Burst
Surge
Voltage Dip & Interruption
Mounting
Typical Wiring
0.03 ~ 3A
(0.03, 0.07, 0.1, 0.3, 0.5, 1, 1.5, 2, 2.5 and 3A Tap )
0.2 ~ 2.0sec
(0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8 and 2.0 sec Tap)
Definite Time
ZCT(CBCT) - Zero Phase Current Detection
240VAC 10%
50/60Hz
5%
5%
5A/250VAC Resistive
1-SPDT / Normally De-energized
600VAC, 50/60Hz
10,000,000 Operation
100,000 Operation
-20 ~ 60
10 ~ 85% without Condensation
Casing-Circuit
2kV, 50/60Hz, 1min
Contact-Contact
1kV, 50/60Hz, 1min
Circuit-Circuit
2kV, 50/60Hz, 1min
IEC61000-4-2 Level-3
IEC61000-4-4 Level-3
IEC61000-4-5 Level-3
IEC61000-4-11
Flush Mount (Panel Door Mount)
Current Setting
Time Setting
Operating Characteristic
Current Sensing
Control Voltage
Frequency
Current Tolerance
Time Tolerance
Contact Rating
Rated Insulation Voltage
Expected Mechanical Life
Expected Electrical Life
Ambient Temperature
Ambient Humidity
Dielectric Strength
Electrostatic Discharge
EFT / Burst
Surge
Voltage Dip & Interruption
Mounting
0.1 ~ 2.5A
(0.1, 0.3, 0.5, 0.7, 1.0 , 1.3, 1.5, 1.7, 2.0 and 2.5A Tap)
0.2 ~ 2.0sec
(0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8 and 2.0 sec Tap)
Definite Time
Residual Current Detection
240VAC 10%
50/60Hz
5%
5%
5A/250VAC Resistive
1-SPDT / Normally De-energized
600VAC, 50/60Hz
10,000,000 Operation
100,000 Operation
-20 ~ 60
10 ~ 85% without Condensation
Casing-Circuit
2kV, 50/60Hz, 1min
Contact-Contact
1kV, 50/60Hz, 1min
Circuit-Circuit
2kV, 50/60Hz, 1min
IEC61000-4-2 Level-3
IEC61000-4-4 Level-3
IEC61000-4-5 Level-3
IEC61000-4-11
Flush Mount (Panel Door Mount)
Typical Wiring
27
EGR
PMR
Features
MCU Based Compact Design
Ground Fault Protection with ZCT
Trip & Run Indication LED
Manual / Electrical Reset
Features
MCU Based Compact Design
Multiple Protection Functions
2 - 15% Voltage Unbalance Setting
Trip Cause Indication & Troubleshooting
Manual / Electrical / Automatic Reset
Ambient Insensitive
Fail-safe Operation
Protection
Protection
Protective Item
Ground Fault
Trip Time
O-Time
Specification
Ground Fault (GF)
Current Setting
Trip Time
0.1 sec
1 sec
5 sec
Protective Item
Phase Reversal
Phase Loss
Voltage Unbalance
Specification
Type
05
10
20
O-TIME
Mode/Rating
Status
Range
50 - 500mA
100 - 1,000mA
200 - 2,500mA
0.2 - 2.0 sec
Manual / Electrical
(Push RESET Button or Interrupt Supply Power)
110 / 220VAC, 50/60Hz
1-SPDT(1C), 3A/250VAC Resistive
Normally De-energized
35mm DIN-Rail / Panel
Control Voltage
Type
220
440
Reset
Contact Rating
Mode
Rating
Status
Mounting
Troubleshooting
LED Signal (Pulse Chart)
Condition
Normal Run
Voltage Unbalancing
Voltage Unbalance
R
Phase
Trip
S
Loss
T
Phase Reversal
Typical Wiring
28
Range
3 160 - 300VAC, 50/60Hz
3 340 - 480VAC, 50/60Hz
Manual (Instantaneous) / Electrical
Automatically reset with 5 sec delay
when supply power comes to normal.
1 - SPDT (1C)
5A/250VAC Resistive
Normally Energized
35mm DIN-rail/Rail
Typical Wiring
Green LED
On
On
Off
Off
Off
Off
Red LED
Off
On
On
Flickering
Flickering
Flickering
Flickering alternatively
2CT
Current Transformer
Features
Fitted to EOCR relays for Large Amp Motor Protection
1.0 Measuring Class
For EOCR Only
ZCT
Current Transformer
Features
Fitted to EOCR relays for Large Amp Motor Protection
1.0 Measuring Class
For EOCR Only
Specification
Specification
Model
Current Ratio
Class
Budden
Insulation Voltage
Dielectric Strength
Insulation
Mounting
3CT
2CT-100
100 : 5A
1.0
5VA
2CT-150
150 : 5A
1.0
5VA
2CT-300
2CT-200
200 : 5A
300 : 5A
1.0
1.0
5VA
5VA
600VAC
2kV
10M (500VDC Megger)
Panel
2CT-400
400 : 5A
1.0
5VA
Model
Current Ratio
Class
Budden
Insulation Voltage
Dielectric Strength
Insulation
Mounting
3CT-100
100 : 5A
1.0
5VA
SR-CT
3CT-150
150 : 5A
1.0
5VA
3CT-300
3CT-200
200 : 5A
300 : 5A
1.0
1.0
5VA
5VA
600VAC
2kV
10M (500VDC Megger)
Panel
Current Transformer
Features
Applicable for Ground Fault Protection Devices (EGR)
Detect Zero Phase Current
For EOCR Only
Features
Fitted to EOCR relays for Large Amp Motor Protection
Satisfied with IEC Inverse Trip Characteristic
Protection Class
For EOCR Only
Specification
Specification
Hole Dimension
Primary GF Current
Secondary GF Current
Tolerance
Budden
Rated Voltage
Dielectric Strength
Insulation
Mounting
Type
ZCT - 35
ZCT - 80
ZCT - 120
Hole
35mm
80mm
120mm
200mA
1.5mA
10%
10VA
600VAC
2kV
10M (500VAC Megger)
Panel
Current Ratio
Type
SR-CT-100
SR-CT-150
SR-CT-200
SR-CT-300
SR-CT-400
3CT-400
400 : 5A
1.0
5VA
29
Dimension
EOCR-SS / AR / EUCR
EOCR-SS1 / SS2
SDDR
EOCR-PMZ
30
EVR-FD
2CT
ELR / EFR2.5
3CT
SR-CT
EOCR-PFZ
31
Dimension
32
ZCT
MEMO
MEMO
MEMO
Head Office
Iksan Plant
574, Yongie-dong, Iksan-shi, Junbuk, Korea
Tel. 82 63 835 5033 / Fax 82 63 835 4175
EOCR_EN