Fire stations must accommodate diverse functions including housing firefighters, storing vehicles and equipment, vehicle maintenance, training, and community functions. The layout is primarily driven by minimizing firefighter response times and separating industrial and residential spaces. Key areas include the apparatus bays, support areas, administrative offices, training rooms, dorms, kitchen and recreation spaces. Design considers occupant quality of life, health and safety, and flexibility for future needs.

Uploaded by

Atmreza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
2K views

Fire Station Design Guide

Fire stations must accommodate diverse functions including housing firefighters, storing vehicles and equipment, vehicle maintenance, training, and community functions. The layout is primarily driven by minimizing firefighter response times and separating industrial and residential spaces. Key areas include the apparatus bays, support areas, administrative offices, training rooms, dorms, kitchen and recreation spaces. Design considers occupant quality of life, health and safety, and flexibility for future needs.

Uploaded by

Atmreza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

2/15/2016

FireStation|WholeBuildingDesignGuide

FireStation|WholeBuildingDesignGuide
FireStation
byEricG.Mion
Lewis&ZimmermanAssociates,Inc.
Lastupdated:06012009

Overview
Afirestationsupportstheneedsofthefiredepartmentandthecommunityinwhichitislocated.Itmust
accommodateextremelydiversefunctions,includinghousing,recreation,administration,training,
communityeducation,equipmentandvehiclestorage,equipmentandvehiclemaintenance,and
hazardousmaterialsstorage.Whileitisusuallyonlyoccupiedbytrainedpersonnel,thefacilitymayalso
needtoaccommodatethegeneralpublicforcommunityeducationoroutreachprograms.
Firestationswillvarysomewhatindesigndependingonspecificmission,i.e.,thetypesofemergencies
thatwillberespondedtoorthetypesoffiresthatwillbefought.Usually,thefacilitydifferencesrelateto
thesizeofthefirefightingapparatusandfacilitylocation.Thelocationofthefacilityislargelydrivenby
theneedtominimizeresponsetime.Forexample,aircraftrescuefirefighting(ARFF)stationsprovide
fireprotectiontoflightlinesandaircraftandarelocatedadjacenttotherunwaysonairportproperty.
Similarly,stationswithhazardouswasteresponseteamsarelocatednearlikelyspillsites,etc.

BuildingAttributes
A.SpaceTypesandBuildingOrganization
Majorfirestationfunctionalareasincludethefollowing:
Apparatusbay(s):Thisiswherethefirefightingandemergencyresponsevehiclesarestored.
Apparatusbaysupportandvehiclemaintenance:Theseindustrialspacesarewherethevehiclesand
otherfirefightingequipmentarecleaned,maintained,andstored.
Administrativeandtrainingareas:Theseincludeoffices,dispatchfacilities,andtrainingand
conferencerooms.
Residentialareas:Theseincludethedormrooms,dayroom/kitchen,andresidentialsupportareas
suchasbathroomsandfitnessspaces.
Thetwoprimarydriversforfacilitylayoutandfunctionalspaceadjacenciesinafirestationarethe
https://www.wbdg.org/design/firestation.php

1/6

2/15/2016

FireStation|WholeBuildingDesignGuide

following:
1.Ensurethatinternalresponsetimescanbemet(timeforafirefightertoreachtheapparatusandbe
readytodepart).
2.Separatethediverseandsometimesconflictingfunctionssuchasindustrialmaintenancespacesand
residentialspaces.

Sampleadjacencydiagramforafirestation.
DevelopedbyDMJMDesign,Arlington,VA
ApparatusBays
Byplacingtheapparatusbaybetweenthemaintenanceandsupportfunctionsandtheresidentialand
administrativefunctions,bothprimarylayoutgoalscanbeaccomplished.Someoftheadjacencies
shownabovemaybeaccommodatedthroughahallwayratherthanadirectentrance/exitfromone
spacetoanother.Thisisparticularlytruewiththeapparatusbayandthedayroomasmanyfacility
spacesrequireanadjacencywiththesetwospaces.
Thisapproachtothelayoutcanalsoaccommodateexpansionoftheapparatusbayontheothersideof
thesupportandmaintenanceareas,althoughcaremustbetakentoensurethatinternalresponsetimes
canbemetafteranyexpansion.
Sizingtheapparatusbayiscritical,anditshouldbedesignedtoaccommodatevariablevehiclesizes.
Typically,theentireroomissizedbasedonthebaysizeforthelargestvehicleinthefleetorthelargest
anticipatedvehicle.Baysalsoincludevehicleexhaustremovalsystems,compressedairandpowerdrop
lines,andhotandcoldwaterconnections.Baydoorsmustalsoaccommodatethelargestvehicleand
includeamanualmeanstoopenincaseofpowerfailure.Ideally,thesitewillaccommodatedrive
throughbays.
https://www.wbdg.org/design/firestation.php

2/6

2/15/2016

FireStation|WholeBuildingDesignGuide

Samplefunctionallayoutforafirestation.
DevelopedbyDMJMDesign,Arlington,VA
ApparatusBaySupportandVehicleMaintenance
Apparatusbaysupportfunctionsincludecleaningandmaintenanceareasforthefirefighter'sself
containedbreathingapparatus(SCBA),protectiveclothing,fireextinguishers,andotherequipment.It
alsoincludesstorageareasforfirefightinggearandequipmentandsecurestorageformedicalsupplies.
Someoftheseareasarespecializedspacesfordisinfectingprotectiveequipmentandformaintaining
andrechargingtheSCBAinacleanenvironment.SeealsoLightIndustrialspacetype.
Agentstorageistypicallyprovidedinasinglestorystructureseparatefromthefirestationbuilding.It
shouldbelocatedalongthedriveleadingintotheApparatusBayforeaseofloadingandunloadingof
firefightingagents.Insomecases,itmaybeattachedtothemainstructure.
Avehiclemaintenancebaymayalsobeincludedinafirestation.Itisadedicatedmaintenanceareafor
thefirefightingapparatusandincludesaheavydutyliftandallutilityconnectionsrequiredforlarge
vehiclemaintenance.
AdministrativeandTrainingAreas
Administrativeareasincludestandardofficesandconferenceandtrainingrooms.Theareawillalso
likelyincludeadditionalspecializedspacessuchasthechief'sofficewithsleepingandshowerfacilities
andcomputertraining/testingfacilitiesforfirefightercontinuingeducation.Somestationsmayincludea
highlyspecializeddispatchroomforreceivingemergencycallsfromthepublic.
ResidentialAreas
https://www.wbdg.org/design/firestation.php

3/6

2/15/2016

FireStation|WholeBuildingDesignGuide

Sampledayroomlayoutforafirestation.
DevelopedbyDMJMDesign,Arlington,VA
Thedayroomaccommodateskitchen,dining,andliving/recreationfunctions.Itisoftenseparatedinto
subspacesforthosethreefunctions,butanopendesignmayalsobeeffectivetoencourageinteraction
betweenthespaces.Thediningspacemayalsodoubleastrainingormeetingspaceandmightinclude
provisionsforaudiovisualequipment.
Dormroomdesigncanvarywidelyfromstationtostationanddepartmenttodepartment.Each
firefighterisprovidedwithaplacetosleep,work,andstorepersonalitems.Carefulconsiderationshould
begiventothelocationanddesignoftheareatoensureresponsetimescanbemet.SeeEmerging
Issuesbelowformoreinformationondormrooms.
Otherresidentialareasincludealaundryroom,aphysicalfitnessroom,bathroomsandshowers,and
possibleadditionalrecreationspacessuchasanoutdoorpatioandgameroom.

B.DesignConsiderations
Keydesigngoalsandconsiderationsforfirestationsincludethefollowing:
PromoteOccupantQualityofLife
Firestationsareoccupied24hoursaday,sevendaysaweekbypersonnelincontinuous24hourshifts.
Therefore,ensuringacomfortablelivingenvironmentforthefirefightersisparamount:
https://www.wbdg.org/design/firestation.php

4/6

2/15/2016

FireStation|WholeBuildingDesignGuide

Provideamplenaturallight.
Provideindividualdormrooms,ifbudgetallows.
Provideamplerecreationareasandseparatenoisyareas(suchasagameroom)fromquieterareas
(suchasatelevisionroom).
Avoidinstitutionalandunnaturalfinishes,textures,andcolors.
MaintainaSafeandHealthyEnvironment
Asabove,duetothecontinuousoccupationofthefacilitybyfirefightersandthepresenceofhazardous
materials,specialattentionmustbegiventodesigningthefacilitytoaccommodateequipmentand
operationalstrategiestobothprotecttheoccupantsandmaintainahealthyenvironment.Considerthe
followingcriticalelements:
Provideasecurefacilityforbothpersonnelandmaterialssuchascontrolledmedicalsuppliesand
hazardousfiresuppressionagents.
Usenontoxicbuildingmaterialsandimprovedmaintenancepractices.
Ensuregoodindoorairqualityandabundantnaturallightintheresidentialandadministrativeareas.
Ensuregoodventilationofindustrialareassuchastheapparatusbayandpreventcontaminationof
cleanspacessuchastheSCBAmaintenanceareas.
Ensurethatequipment,furnishings,andfinishesdonotcontainasbestosorlead.
EnsureFlexibility
Asfirefightingtechnologyevolves,firestationsneedtoevolveaswell.Considerthefollowingareas:
Planforpotentialexpansion,bothintheapparatusbayareaandtheresidentialareas.

EmergingIssues
Oneemergingissueinfirestationdesignistheadditionalattentiongiventofirefighterqualityoflife.As
notedaboveindesignconsiderations,onewaytopromotequalityoflifeistoprovideseparatedorm
roomsforeachfirefighter.Typically,eachroomissharedbetweenfirefightersofdifferentcrews/shiftsso
thattheroomisneveroccupiedsimultaneously.Individuallockersareprovidedforeachfirefighter.A
bed,nightstand,anddeskareshared.
Somedepartmentsaretakingthisonestepfurtherandprovidingseparatebedsforeachfirefighter.
Wallbeds,alsoknownas"Murphybeds,"arealsobecomingacommonalternative.Thesecombinethe
qualitiesofanindividualbedwithaddedspacesavings.

https://www.wbdg.org/design/firestation.php

5/6

2/15/2016

FireStation|WholeBuildingDesignGuide

Threesampledormroomlayoutsforafirestation.
DevelopedbyDMJMDesign,Arlington,VA

RelevantCodesandStandards
Standardfederalandstatebuildingcodesapply,asappropriate.Therearealsonumerouscodesand
standardsthatapplytothestaffingandoperationofafire/rescuedepartmentkeystandardsincludethe
following:
AirportRescueandFirefightingStationBuildingDesignAdvisoryCircular150/521015,byU.S.
DepartmentofTransportation,FederalAviationAdministration(FAA).1987.
FireSuppressionRatingSchedule(FSRS),byInsuranceServicesOffice,Inc.(ISO).
NFPA403:StandardforAircraftRescueandFireFightingServicesatAirports,byNationalFire
ProtectionAssociation(NFPA).2003.
NFPA1500:FireDepartmentOccupationalSafetyandHealthProgram,byNFPA.2002.
NFPA1581:FireDepartmentInfectionControlProgram,byNFPA.2005.
NFPA1710:StandardfortheOrganizationandDeploymentofFireSuppressionOperations,
EmergencyMedicalOperations,andSpecialOperationstothePublicbyCareerFireDepartments,by
NFPA.2004.
NFPA1720:StandardfortheOrganizationandDeploymentofFireSuppressionOperations,
EmergencyMedicalOperations,andSpecialOperationstothePublicbyVolunteerFireDepartments,
byNFPA.2004.

https://www.wbdg.org/design/firestation.php