4 - L55 Unit Operations Lab - Data Sheets
4 - L55 Unit Operations Lab - Data Sheets
calDat
aSheet
s
L55Uni
tOper
at
i
onsLab.
I
t
e
m
De
s
c
r
i
pt
i
on
Code
Qt
y
.
I
t
e
m1
Di
f
f
u
s
i
o
ni
nL
i
q
u
i
d
sa
n
dGa
s
e
s
CE1
1
0
I
t
e
m2
Fa
l
l
i
n
gFi
l
mAb
s
o
r
p
t
i
o
n
CE4
0
5
I
t
e
m3
Co
n
t
i
n
u
o
u
sRe
c
t
i
f
i
c
a
t
i
o
n
CE6
0
0
I
t
e
m4
So
l
i
d
L
i
q
u
i
dEx
t
r
a
c
t
i
o
n
CE6
3
0
I
t
e
m5
L
i
q
u
i
d
L
i
q
u
i
dEx
t
r
a
c
t
i
o
n
CE6
2
0
I
t
e
m6
We
t
Co
o
l
i
n
gTo
we
r
WL3
2
0
Pl
e
a
s
ec
l
i
c
khe
r
ef
orf
ur
t
he
ri
nf
or
ma
t
i
on:
h
t
t
p
:
/
/
www.
g
u
n
t
.
d
e
/
s
t
a
t
i
c
/
s
4
9
9
4
_
1
.
p
h
p
I
t
e
m7
Ga
sAb
s
o
r
p
t
i
o
n
CE4
0
0
I
t
e
m8
Ca
k
ea
n
dDe
p
t
hFi
l
t
r
a
t
i
o
n
CE1
1
6
Pl
e
a
s
ec
l
i
c
khe
r
ef
orf
ur
t
he
ri
nf
or
ma
t
i
on:
h
t
t
p
:
/
/
www.
g
u
n
t
.
d
e
/
s
t
a
t
i
c
/
s
5
3
3
7
_
1
.
p
h
p
I
t
e
m8
.
1
Pr
e
c
i
s
i
o
nBa
l
a
n
c
e1
0
1
0
0
g/
0
.
1
g
CE1
1
6
.
0
1
I
t
e
m9
Co
o
l
i
n
gCr
y
s
t
a
l
l
i
s
a
t
i
o
n
CE5
2
0
I
t
e
m1
0
Ad
s
o
r
p
t
i
v
eAi
rDr
y
i
n
g
CE5
4
0
I
t
e
m1
1
Ri
s
i
n
gFi
l
mEv
a
p
o
r
a
t
i
o
n
CE7
1
5
I
t
e
m1
1
.
1
El
e
c
t
r
i
c
a
l
St
e
a
mGe
n
e
r
a
t
o
r1
0
k
W
CE7
1
5
.
0
1
I
t
e
m1
2
Mu
l
t
i
v
a
r
i
a
b
l
eCo
n
t
r
o
l
:
Va
c
u
u
mDe
g
a
s
s
i
n
g
RT6
8
1
I
t
e
m1
3
Mu
l
t
i
v
a
r
i
a
b
l
eCo
n
t
r
o
l
:
St
i
r
r
e
dTa
n
k
RT6
8
2
02/
09/
2014
pr
i
nt
edby
:Jr
genKr
i
l
l
GNTT1054
page 1/1
Page 1/2
05/2014
CE 110
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
05/2014
CE 110
Technical Data
Tank with stirrer: approx. 1500mL
Speed stirrer: 0...1500min-1
253 capillaries made of glass
- diameter: 1mm, length: 5mm
Water bath: approx. 2L
Diffusion tube for solvent
- diameter: 3,4mm, length: 85mm
Power output heater: approx. 150W
Fan: 120...320L/h
Microscope scale division: 0,1mm
Measuring ranges
- temperature: 0...100C
- conductivity: 0...200mS/cm
Order Details
Diffusion in gases: 1 air flow, 2 gaseous solvent, 3 water bath, 4 liquid solvent,
5 meniscus in the microscope, 6 heater, 7 display and control unit
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
10/2013
CE 405
Technical Description
Absorption is used to remove one or more gaseous
components from a gas flow using a solvent. Selective
absorption is an important industrial process for the
treatment of gas mixtures. CE 405 can be used to
investigate the basic processes on the water-oxygennitrogen system.
A compressor supplies ambient air from below into
the absorption column. Water flows down as a thin film
at the edge of the absorption column. The air flows
upwards centrally in the column. A portion of the air's
oxygen is dissolved in the water film. The air flow exits
the column at the top. The water containing the
dissolved oxygen leaves the column at the bottom and
flows into a tank. A pump supplies the water with the
dissolved oxygen to the head of the desorption
column.
The desorption column is a simple tube in which the
water flows downwards. Nitrogen from a compressed
gas cylinder enters at the base of the column. The
nitrogen rises to the top in the form of dispersed
bubbles in the water. The partial pressure of the
oxygen in water is higher than the partial pressure in
the gas phase (nitrogen). For this reason, a portion of
the oxygen passes over from the water into the gas
phase (stripping). This process leads to the water's
absorbing capacity for oxygen increasing.
A pump supplies the solvent regenerated in this way
into a channel circulating the upper part of the
absorption column. From here the water again flows
along the inner wall of the absorption column as a thin
falling film and absorbs a portion of the air's oxygen.
The oxygen concentration and temperature are
continuously
measured
both
upstream
and
downstream of the absorption column. Valves and flow
meters make it possible to adjust the air flow rate and
solvent flow rate. Transparent materials allow optimal
observation of the processes in both columns.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
Learning Objectives / Experiments
- investigation of the absorption process during the
separation of oxygen from an air flow in a falling
film column
- balance of the process
- determination of the mass transfer coefficient
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
10/2013
CE 405
Technical Data
Absorption column
- height: 890mm
- inner diameter: 32mm
- material: glass
Desorption column
- height: 1650mm
- inner diameter: 24mm
- material: PMMA
2 Pumps
- max. flow rate: 58L/min each
- max. head: 3,7m each
1 Compressor
- max. positive pressure: 2bar
- max. flow rate: 23L/min
1 Tank
- capacity: approx. 50L
- material: plastic
Measuring ranges:
- water flow rate: 40...360mL/min
- air flow rate: 20...360NL/h
- temperature: 2x 0...50C
- oxygen concentration: 2x 0...70mg/L
Dimensions and Weight
LxWxH: 1050x700x2140mm
Weight: approx. 135kg
Required for Operation
230V, 50Hz, 1 phase
Nitrogen gas cylinder with pressure reducing valve
Scope of Delivery
1 trainer
2 hand-held measuring units for measuring
oxygen
1 calibration set for oxygen sensor
1 set of hoses
1 set of instructional material
Order Details
083.40500 CE 405 Falling Film Absorption
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
05/2014
CE 600
Continuous Rectification
Technical Description
Distillation is used to separate liquid mixtures made
up of individual liquids that are soluble in one another.
Rectification refers to distillation in a counterflow.
Ethanol/water is recommended as the liquid mixture
for the CE 600. It is fed into the column. It partially
evaporates on its way to the bottom of the column
where it is heated to boiling. The mixed vapour
produced then moves upwards in the column. The
mixed vapour contains a higher concentration of the
component with the lower boiling point (ethanol). It
leaves the top of the column and is condensed using a
condenser and a phase separation tank. Part of this
condensate is collected in a tank as product while the
rest is fed back into the column. Here, on its way
downwards, it undergoes further heating and material
exchange with the rising mixed vapour. This exchange
causes the vapour phase to become richer in ethanol
and the liquid phase to become richer in water. The
liquid phase moves to the bottom and can be collected
in two tanks.
A heat exchanger allows the feed to be preheated by
the bottom product carried away from the column. A
sieve plate column and a packed column are available.
The sieve plate column has three connections at
different heights for the feed. The packed column is
filled with Raschig rings. The reflux ratio is adjusted
using valves.
Relevant measured values are recorded by sensors,
displayed and can be processed on a PC. The
software also allows controlling the temperature at the
top of column or at the bottom of column (evaporator).
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
The illustration shows the CE 600 with built in sieve plate column. The packed column
can be seen in the foreground.
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
05/2014
CE 600
Continuous Rectification
Specification
[1] continuous and discontinuous rectification with
packed and sieve plate column
[2] interchangeable columns
[3] sieve plate column with 8 plates, 3 feed inlets
[4] packed column with Raschig rings
[5] vacuum mode possible with water jet pump
[6] electrically heated evaporator
[7] tanks for feed, bottom and top product
[8] heat exchanger for bottom product cooling due to
feed preheating or cooling water
[9] condenser and phase separation tank for top
product
[10] all tanks made of DURAN glass and stainless
steel
[11] adjustment of reflux ratio using valves
[12] 8 temperature sensors per column
[13] GUNT software with control functions and data
acquisition via USB under Windows Vista or
Windows 7
1 top product condenser, 2 phase separation tank, 3 valves (reflux ratio), 4 cooling
water flow meter, 5 sieve plate or packed column, 6 evaporator, 7 bottom heat
exchanger, 8 feed pump, 9 bottom product tank, 10 feed tank, 11 switch cabinet with
displays and controls, 12 top product tank, 13 water jet pump
Technical Data
Columns
- internal diameter: 50mm
- height: 780mm
Feed pump
- max. flow rate: 200mL/min
Water jet pump: final vacuum: approx. 200mbar
Tanks
- feed: 2x approx. 5L
- bottom product: 2x approx. 4L
- top product: approx. 1,5L
- phase separation: approx. 0,5L
Heat transfer surfaces
- feed preheating/bottom cooling: approx. 0,03m
- top product condenser: approx. 0,04m
Measuring ranges
- temperature: 16 x 0...150C
- reflux ratio: 0...100%
- heating power: 0...4kW
- column differential pressure: 0...250mbar
- cooling water flow rate: 30...320L/h
- system pressure gauge: -1...0,6bar
Dimensions and Weight
LxWxH: 1300x760x2400mm
Weight: approx. 295kg
Required for Operation
400V, 50/60Hz, 3 phases or 230V, 60Hz/CSA,
3 phases
Cold water connection: 500...1000L/h, drain
1 evaporator with column, 2 bottom heat exchanger, 3 bottom product tank, 4 feed
tank, 5 feed pump, 6 top product tank, 7 feed, 8 reflux, 9 condenser, 10 phase
separation tank, 11 water jet pump, 12 solvent tank;
F flow rate, L level, P pressure, PD differential pressure, T temperature;
dotted, blue line: cooling water
Scope of Delivery
1 trainer (with 2 columns)
1 set of hoses
1 set of accessories (tools, seals)
1 GUNT software CD + USB cable
1 set of instructional material
Order Details
083.60000 CE 600 Continuous Rectification
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
09/2013
CE 630
Solid-Liquid Extraction
Technical Description
The CE 630 allows a soluble component of a solid
mixture to be extracted with a revolving extractor.
In continuous 3-stage mode, pure solvent (distilled
water) is delivered from a tank to the sprinkler of the
first extraction stage where it is distributed over the
solid mixture (extraction material). The solvent seeps
through the extraction material, absorbs its soluble
components (potassium hydrogen carbonate) and
passes into the collecting segments. From there, the
enriched solvent is delivered to the sprinkler of the
next stage. After passing through the last stage, the
extract (the solvent charged with the extracted
component) is collected in the extract tank. The
extraction material is continuously fed into the cells of
the rotating extractor by a spiral conveyor. The
extraction material and the solvent move in
counterflow. The extraction residue drops into a tank
after one revolution of the extractor.
Valves can be used to switch to 1- or 2-stage
continuous mode. Discontinuous mode is possible with
the extractor stopped.
Three pumps are available for delivering the solvent.
Their speed can be individually adjusted for each
stage. The temperature of the solvent can likewise be
adjusted for each stage with PID controllers. Each
stage is equipped with conductivity sensors to monitor
the separation process. All measured values can be
viewed by software.
The solid mixture (extraction material) is produced
prior to the extraction experiment. The carrier material
(granular aluminium oxide) is fed into a salt solution
(potassium hydrogen carbonate dissolved in water).
The carrier material soaked with the salt solution is
then dried.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
We reserve the right to modify our products without any notifications.
Visit our Websites: www.gunt.de | www.gunt2e.de
Page 2/2
09/2013
CE 630
Solid-Liquid Extraction
Specification
[1] revolving extractor for continuous and
discontinuous solid-liquid extraction
[2] switching to 1-, 2- or 3-stage modes possible by
valves
[3] extractor revolving speed adjustable by
potentiometer
[4] spiral conveyor with variable speed to adjust the
extraction material feed rate
[5] flow rate of solvent adjustable for each stage via
speed of pumps
[6] temperature of solvent adjustable for each stage by
PID controller
[7] tanks for extraction material, extraction residue,
solvent and extract
[8] GUNT software for data acquisition via USB under
Windows Vista or Windows 7
Technical Data
Extractor
- 9 cells
- rotor diameter: approx. 200mm
- speed: approx. 0...9h-1
- motor power consumption: approx. 0,9W
Spiral conveyor
- max. feed rate: approx. 20L/h
- motor power consumption: approx. 4W
4 peristaltic pumps
- max. flow rate: approx. 25L/h at 300min-1 and hose
4,8x1,6mm
3 heaters
- power consumption: approx. 330W
Tanks
- extraction material: approx. 5L
- extraction residue, solvent, extract: each approx. 20L
Measuring ranges
- flow rate: 1x 0,025...0,5L/min
- conductivity: 4x 0...20mS/cm
- temperature: 4x 0...50C
Dimensions and Weight
LxWxH: 880x700x1740mm
Weight: approx. 150kg
Required for Operation
230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Scope of Delivery
1 trainer
1 set of tools
1 hose
1 GUNT software CD + USB cable
1 packing unit of aluminium oxide
1 packing unit of potassium hydrogen carbonate
1 set of instructional material
Order Details
083.63000 CE 630 Solid-Liquid Extraction
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
We reserve the right to modify our products without any notifications.
Visit our Websites: www.gunt.de | www.gunt2e.de
Page 1/2
09/2013
CE 620
Liquid-Liquid Extraction
Technical Description
The CE 620 allows liquid mixtures to be separated
using liquid-liquid extraction.
The liquid mixture to be separated is delivered from
the feed tank into the bottom of the extraction column
using a pump. There, it moves in counterflow towards
the solvent, which is delivered into the top of the
extraction column by a pump. The mixture to be
separated is made up of a transition component and
carrier liquid. The carrier liquid and the solvent are
insoluble in one another and therefore a phase
boundary is established in the column. This can be
observed and can be adjusted using two valves. The
movement of the transition component from the carrier
liquid into the solvent occurs inside the column. Two
three-way valves can be used to operate the trainer as
a continuous or a discontinuous process.
A distillation unit facilitates the enrichment of the
transition component in the extract. This consists of a
heated round-bottomed flask with a packed column
and a distillation bridge with Liebig condenser. The
enriched extract leaves the column at the top and is
collected in a tank. The bottom temperature is
measured by a sensor, displayed digitally and
controlled using a PID controller. The temperature at
the top of the distillation column is also measured.
Distillation removes the solvent from the transition
component which is collected at the bottom of the unit
and can be drawn off as a product. The separated
solvent is collected in a tank and can be reused for
extraction.
For a ternary material system, rapeseed oil is
recommended as the carrier liquid with ethanol as the
transition component and water as the solvent. For this
ternary material system the concentrations of extract,
top and bottom product are determined by
measurement of density. A conductivity meter is
included for alternative ternary material systems.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
Learning Objectives / Experiments
- transition of a component from a two-component
liquid mixture into a solvent by extraction
- scale-up from beaker experiment to pilot plant scale
- enrichment of transition component in extract by
distillation
- evaluation of separation processes via
concentration
measurement and mass balances
- influence of different experimental options on
separation processes
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
09/2013
CE 620
Liquid-Liquid Extraction
Specification
[1] liquid-liquid extraction in counterflow operation with
distillation for enrichment of the extract
[2] operation as continuous or discontinuous process
using 2 three-way valves
[3] glass extraction column
[4] distillation column and distillation bridge with Liebig
condenser
[5] electrical bottom heating via PID controller
[6] water jet pump for reduction of evaporation
temperature during distillation
[7] stainless steel tanks for feed, solvent, raffinate,
extract and top product (distillation)
[8] 2 pumps to deliver the feed and solvent
[9] 2 valves for adjusting the phase boundary
[10] distillation column packed with Raschig rings
1 extraction column, 2 extract tank, 3 flow meters feed and solvent, 4 top product
tank (distillation), 5 distillation unit, 6 valve for phase boundary, 7 solvent tank,
8 feed pump, 9 solvent pump, 10 feed and raffinate tank, 11 switch cabinet,
12 three-way valves, 13 process schematic
Technical Data
Columns
- extraction: diameter: 40mm, height: 1.500mm
- distillation: diameter: 30mm, height: 415mm
Bottom heater power output: 1200W
Tanks
- feed and raffinate: approx. 30L each
- solvent and extract: approx. 15L each
- top product (distillation): 15L
- bottom tank (distillation): approx. 5L
Feed pump
- max. flow rate: 1000ml/min
- max. head: 80m
Solvent pump
- max. flow rate: 1200ml/min
- max. head: 10m
Water jet pump: final vacuum: approx. 200mbar
Measuring ranges
- temperature: 1x 0...150C, 1x 0...120C
- flow rate: 2x 100...850ml/min (water)
- pressure: -1...0,6bar
- conductivity:0...1990S/cm
Dimensions and Weight
LxWxH: 1350x750x2150mm
Weight: approx. 180kg
Required for Operation
230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Water connection: 720L/h
1 extraction column, 2 three-way valves, 3 water jet pump, 4 solvent pump, 5 solvent
tank, 6 top product tank (distillation), 7 extract tank, 8 Liebig condenser with cooling
water connection, 9 distillation column, 10 feed pump, 11 feed tank, 12 raffinate
tank; F flow rate, P pressure, T temperature, L level
Scope of Delivery
1 trainer
2 glass cylinders
1 measuring cup
1 stirrer
1 conductivity meter
1 set of hoses
1 set of instructional material
Order Details
083.62000 CE 620 Liquid-Liquid Extraction
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/3
04/2014
WL 320
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/3
04/2014
WL 320
1 nozzle as atomiser, 2 wet deck surface, 3 displays and controls, 4 air chamber,
5 fan with throttle valve, 6 pump, 7 tank with heating, 8 tank for additional water,
9 combined temperature/humidity sensor
Specification
[1] principle of a wet cooling tower with cooling column
and forced ventilation
[2] interchangeable cooling columns with different wet
deck surfaces available as accessories
[3] water circuit with pump, filter, valve and a nozzle as
atomiser
[4] three-stage heater with thermostat for water
heating
[5] radial fan for forced ventilation
[6] throttle valve to adjust the air flow
[7] demister unit at the outlet of the cooling columns
minimises water loss
[8] tank for additional water compensates for water
loss
[9] display of temperature, differential pressure, flow
rate and humidity
[10] GUNT software for data acquisition via USB under
Windows Vista or Windows 7
Technical Data
Cooling column
- specific surface of the wet deck surface: 110m/m
- cross-section: 150x150mm
Volumetric air flow measurement via orifice: D=80mm
Heater, adjustable in three stages: 500-1000-1500W
Thermostat: switches off at 50C
Fan
- power consumption: 250W
- max. differential pressure: 430Pa
- max. flow rate: 13m/min
Pump
- max. head: 70m
- max. flow rate: 100L/h
Tank for additional water: 4,2L
1 fan, 2 air chamber, 3 tank with heater, 4 pump, 5 tank for additional water,
6 cooling column with wet deck surface; T temperature,
H humidity, dp differential pressure, F water flow rate
Measuring ranges
- differential pressure (air): 0...1000Pa
- flow rate (water): 12...360L/h
- temperature: 2x 0...50C, 3x 0...100C
- humidity: 10...100% r.h.
Dimensions and Weight
LxWxH: 1110x540x1230mm
Weight: approx. 120kg
Required for Operation
230V, 50/60Hz, 1 phase or 230V, 60Hz/CSA,
3 phases
Scope of Delivery
1 trainer
1 cooling column type 1
1 GUNT software CD + USB cable
1 set of instructional material
Changes of state of air and water in the h-x diagram as online representation in
the software
Order Details
060.32000 WL 320 Wet Cooling Tower
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 3/3
04/2014
WL 320
Available Accessories:
Product no.
060.32001
060.32002
060.32003
060.32004
Order text
WL 320.01
WL 320.02
WL 320.03
WL 320.04
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
04/2014
CE 400
Gas Absorption
Technical Description
Absorption is used to remove one or more gaseous
components from a gas flow using a solvent.
First of all, a CO2 and air gas mixture is produced. It
is possible to adjust the mixing ratio using valves. The
flow rates of the gas components are displayed.
A compressor delivers the gas mixture into the lower
section of the absorption column. In the column, part
of the CO2 is separated in the counterflow with the
solvent. Water is used as the solvent. The CO2 is
absorbed by the downward flowing water. To separate
the absorbed CO2, the charged water is then fed from
the lower section of the absorption column into a
desorption column. As the pressure is reduced and the
temperature is increased, the solubility of the CO2
falls. A heater heats the water. A water jet pump
generates negative pressure in the desorption column
and causes the CO2 gas to be emitted from the water.
A pump then delivers the regenerated solvent back
into the absorption column.
The water temperature can be controlled. Flow rate,
temperature and pressure are continuously measured.
The two-section column is equipped with connections
to determine the pressure losses. The pressure loss in
the respective sections can be displayed via 2 U-tube
manometers. To evaluate the success of the process,
the trainer includes outlets for taking gas and liquid
samples. The gas samples can be analysed using the
hand-held measuring unit supplied.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
Visit our Websites: www.gunt.de | www.gunt2e.de
We reserve the right to modify our products without any notifications.
Page 2/2
04/2014
CE 400
Gas Absorption
Specification
[1] separation of CO2/air mixture by absorption in
counterflow with water
[2] production of gas mixture using CO2 from
compressed gas cylinder and ambient air
[3] adjustment of mixing ratio using valves
[4] compressor for delivering the gas mixture into the
absorption column
[5] DURAN glass absorption column (packed with
Raschig rings) and desorption column
[6] continuous solvent regeneration in circuit with
desorption column under vacuum
[7] 1 pump for desorption column and 1 pump for
returning solvent to absorption column
[8] water temperature control with heater and
refrigeration system
1 absorption column, 2 armoire de commande, 3 CO2 flow meter, 4 air flow meter,
5 solvent flow meter, 6 compressor, 7 process schematic, 8 pump (cooling),
9 cooling tank, 10 pumps (absorption/desorption), 11 refrigeration system, 12 heat
exchanger, 13 heater, 14 U-tube manometer, 15 water jet pump (vacuum),
16 desorption column
Technical Data
Absorption column
- height: 2x 750mm, internal diameter: 80mm
Desorption column
- height: 750mm, internal diameter: 80mm
2 pumps (absorption/desorption)
- max. flow rate: 17,5L/min
- max. head: 47m
1 pump (cooling)
- max. flow rate: 29L/min
- max. head: 1,4m
Compressor
- max. positive pressure: 1bar
- max. flow rate: 4,2m/h
Measuring ranges
- flow rates:
air: 0,2...2,4Nm/h
solvent: 50...600L/h
CO2: 0,4...5,4L/min
- temperature: 1x 0...80C, 2x 0...60C
- pressure: 1x 0...2,5bar, 1x -1...0,6bar
- differential pressure: 2x 0...250mmWC
- CO2-content: 0...100vol%
Dimensions and Weight
LxWxH: 1920x790x2300mm
Weight: approx. 290kg
Required for Operation
230V, 50/60Hz, 1 phase or
230V, 60Hz/CSA, 3 phases
CO2 gas cylinder with pressure reducing valve,
water connection: 250L/h, drainage
1 external CO2 compressed gas cylinder with pressure reducing valve, 2 compressor
(air), 3 absorption column, 4 heat exchanger, 5 desorption column, 6 air for
desorption, 7 water jet pump (vacuum), 8 heater, 9 cooling tank, 10 refrigeration
system; F flow rate, P pressure, PD differential pressure, T temperature,
Q sampling point (gas)
Scope of Delivery
1 trainer
1 hand-held measuring unit for gas analysis
1 set of hoses
1 set of instructional material
Order Details
083.40000 CE 400 Gas Absorption
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
We reserve the right to modify our products without any notifications.
Visit our Websites: www.gunt.de | www.gunt2e.de
Page 1/1
04/2014
CE 116
Scope of Delivery
1 experimental unit
2 measuring cups
1 stopwatch
1 thermometer
1kg sand (1...2mm)
2kg diatomite
1 set of instructional material
Order Details
083.11600 CE 116 Cake and Depth Filtration
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
09/2013
CE 520
Cooling Crystallisation
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/2
09/2013
CE 520
Cooling Crystallisation
Specification
[1] crystallisation from solutions in fluidised bed
[2] stirred tank for preparation of a saturated solution
[3] circuit for undersaturated solution with tank, 2 heat
exchangers for heating and pump
[4] bypass for oversaturated solution with
crystallisation cell and 2 heat exchangers for cooling
[5] removable and fillable crystallisation cell, PMMA
[6] heating circuit with pump, tank, heater and
thermostat
[7] adjustment of flow rate in bypass using valves
[8] measurement and control of temperatures in stirred
tank, tank for undersaturated solution and in
crystallisation cell
1 heat exchanger for cooling, 2 heat exchanger for heating, 3 solution pump, 4 tank
for preparation of saturated solution, 5 tank with heater and thermostat, 6 heating
circuit pump, 7 switch cabinet, 8 stirring machine, 9 tank for undersaturated solution,
10 crystallisation cell
Technical Data
Tanks
- stirred tank: approx. 25L
- for undersaturated solution: approx. 25L
- heating circuit: approx. 32L
Pump (solution)
- max. flow rate: approx. 21L/min
- max. head: approx. 38m
Pump (heating circuit)
- max. flow rate: approx. 6L/min
- max. head: approx. 9m
Crystallisation cell
- diameter: approx. 40mm
- height: approx. 80mm
Heater power output: approx. 2kW
Measuring ranges
- temperature: 3x 0...100C, 1x 0...80C
- flow rate: 1x 0...12L/min
Dimensions and Weight
LxWxH: 2000x800x1850mm
Weight: approx. 255kg
Required for Operation
230V, 50Hz, 1 phase or 230V, 60Hz/CSA, 3 phase
Cold water connection required: min. 3bars; max. 15C
Scope of Delivery
1 trainer
1 hose
1 set of tools
1 set of instructional material
1 external cooling water, 2 solution pump, 3 heating circuit pump, 4 tank with heater
and thermostat, 5 stirred tank for preparation of saturated solution, 6 tank for
undersaturated solution, 7 heat exchanger for heating, 8 heat exchanger for cooling,
9 crystallisation cell;
T temperature, F flow rate
Order Details
083.52000 CE 520 Cooling Crystallisation
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/2
04/2014
CE 540
Technical Description
The CE 540 has been specifically designed to enable
the complex theoretical principles of adsorption
processes to be explained clearly and comprehensibly
by means of experimentation.
A compressor draws in ambient air. The air flows
through the water bath of a humidifier and thereafter
has a relative humidity of 100%. Before the air flows
from below into the adsorption column, its relative
humidity and temperature are set using a heater.
The humid air flows through the adsorbent (silica gel),
which is placed as a fixed bed inside a transparent
column. The quantity of humidity contained in the air is
adsorbed in the process. The adsorbent contains an
indicator. The colour of this indicator shows the
position of the mass transfer zone (MTZ). The air dried
in this way exits the column and flows out into the
open.
To regenerate the adsorbent, ambient air is drawn in
by a second compressor. The air is heated and flows
from above into the column. This desorption process
can also be observed through the transparent column.
The trainer enables simultaneous investigation of the
adsorption and desorption processes. Once the
capacity of the adsorbent in one column is exhausted,
the humid air is fed through a second column with
regenerated adsorbent to dry it.
A circuit system featuring a pump and a refrigeration
system is provided to adjust the temperature of the
water bath in the humidifier. The temperature and
humidity of the air being dried are adjusted by
software. The flow rates of the two air flows can be
adjusted by valves.
By recording the relative humidities and temperatures
at all relevant points, the two processes can be fully
balanced. The measured values are recorded by
software. The software permits the adsorption and
desorption processes to be depicted in a h- diagram
and enables breakthrough curves to be plotted.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
Learning Objectives / Experiments
- fundamental principle of adsorption and desorption
- investigation of the variables influencing adsorption
and desorption
* air flow rates
* air humidity and temperature
* bed height of adsorbent
- depiction of the processes in a h- diagram
- plotting of breakthrough curves and determination
of breakthrough time
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
Visit our Websites: www.gunt.de | www.gunt2e.de
We reserve the right to modify our products without any notifications.
Page 2/2
04/2014
CE 540
1 dried air humidity and temperature sensor, 2 regenerative air temperature sensor,
3 ambient air humidity and temperature sensor, 4 adsorption columns, 5 humidified
feed air humidity and temperature sensor, 6 feed air compressor, 7 refrigeration
system, 8 humidifier (water bath), 9 regenerative air and feed air flow rate sensors,
10 regenerative air compressor, 11 switch cabinet with controls, 12 regenerative air
heater
Technical Data
2 columns
- diameter: approx. 80mm
- height: approx. 800mm
2 compressors
- max. positive pressure: 1bar
- max. flow rate: 8m/h
Humidifier pump
- max. flow rate: 600L/h
- max. head: 1,5m
Refrigeration system
- refrigerating capacity: 395W at temperature
difference 10K / 250L
2 electric air heaters
- power output (feed air): approx. 160W
- power output (regeneration): approx. 500W
Measuring ranges
- flow rate: 2x 1...10Nm/h
- air temperature: 3x 0...50C; 2x 0...120C
- air humidity: 4x 0...100% rel.
- water temperature: 1x 0...50C
Dimensions and Weight
LxWxH: 1385x750x1890mm
Weight: approx. 150kg
1 feed air (blue), 2 humidifier pump, 3 refrigeration system, 4 humidifier (water bath),
5 heater, 6 charged regenerative air (red), 7 adsorption columns, 8 dried air,
9 heater, 10 air for regeneration, 11 ambient air;
M humidity, T temperature, F flow rate
2E a division of G.U.N.T Gertebau GmbH, P.O.Box 1125, D-22885 Barsbttel, t +49 (40)67 08 54-0, f +49 (40)67 08 54-42, E-mail [email protected]
Visit our Websites: www.gunt.de | www.gunt2e.de
We reserve the right to modify our products without any notifications.
Page 1/3
09/2013
CE 715
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/3
09/2013
CE 715
1 heating steam control valve, 2 rising film evaporator, 3 concentrate tank, 4 feed
tank, 5 vacuum pump, 6 cleaning pump, 7 condensate tank, 8 switch cabinet,
9 cyclone, 10 condenser
Order Details
083.71500 CE 715 Rising Film Evaporation
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 3/3
09/2013
CE 715
Available Accessories:
Product no. Order text
083.71501 CE 715.01 Electrical Steam Generator 10kW
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/3
12/2013
RT 681
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/3
12/2013
RT 681
1 vacuum tank, 2 collecting tank, 3 level control valve, 4 pressure control valve,
5 water jet pump, 6 pump (vacuum tank), 7 pump for operation of water jet pump,
8 process schematic, 9 level controller, 10 pressure controller
Measuring ranges
- pressure: -1...0,6bar
- level: 30...480mm
- flow rate: 1x 200...2500L/h, 1x 0...360L/h
Dimensions and Weight
LxWxH: 1150x700x1970mm
Weight: approx. 115kg
Required for Operation
230V, 50Hz, 1 phase or 120V, 60Hz, 1 phase
Compressed air connection for control valve: 2...10bar
Scope of Delivery
1 trainer
1 cable
1 hose
1 CD with software for parameterisation and
configuration of the controllers
1 set of instructional material
1 ambient air, 2 pump for operation of water jet pump, 3 collecting tank, 4 pump
(vacuum tank), 5 level control valve, 6 vacuum tank, 7 water jet pump, 8 pressure
control valve;
F flow rate, P pressure, L level, PIC controller (pressure), LIC controller (level)
Order Details
080.68100 RT 681 Multivariable Control:
Vacuum Degassing
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 3/3
12/2013
RT 681
Available Accessories:
Product no. Order text
080.65060 RT 650.60 Process Control Software for RT 681 - RT 682 Series
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 1/3
10/2013
RT 682
Technical Description
With RT 682 the complexities of a multivariable
control system can be learned in a practical manner.
The model for the controlled process is a typical
application from process engineering: A chemical
reaction taking place in a heated stirred tank. The
reactants entering the stirred tank are pre-heated by
the outflowing products in order to enhance energy
efficiency.
Water is used as the product and reactant for
RT 682. A pump transports the reactant out of a
collecting tank via a heat exchanger into the stirred
tank. The reactant is pre-heated by the heat
exchanger. A heater in the double jacket permits
control of the temperature in the stirred tank. Another
pump transports the heated product out of the stirred
tank via the heat exchanger back into the collecting
tank. A bypass in the inlet routes the flow past the heat
exchanger. A three-way motorised valve adjusts the
ratio between the flow heated in the heat exchanger
and the flow in the bypass. This is a further method of
controlling the temperature in the stirred tank. A
control valve changes the flow rate in the outlet and
thus the level in the stirred tank. The temperature and
level are mutually dependent variables. It is this
dependence that makes this multivariable control
system so complex.
Two industrial controllers are provided as
temperature and level controllers. They can be
configured and parameterised using a supplied
software. The controllers have a Profibus DP interface.
The interface permits monitoring of the trainer via an
optionally available software RT 650.60. The
RT 650.60 software also permits recording of the
process variables and parameterisation of the
controllers using the PC. It is also possible to
interconnect multiple trainers from this series through
the Profibus DP interface.
The well-structured instructional material sets out the
fundamentals and provides a step-by-step guide
through the experiments.
Learning Objectives / Experiments
- coupled level and temperature control
- level control with
* PI controller
* disturbance feedforward control
- temperature control
* with two-point controller
* with three-point controller (split range)
* with override control
* via motorised valve with position feedback
- plotting step responses
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 2/3
10/2013
RT 682
Measuring ranges
- flow rate: 60...640L/h
- temperature: 0...100C
- level: 0...1000mm
- 3-way motorised valve opening: 0...100%
Dimensions and Weight
LxWxH: 1360x610x1940mm
Weight: approx. 162kg
Required for Operation
230V, 50Hz, 1 phase
Water connection: min. 60L/h
Compressed air connection for control valve: 2...10bar
Scope of Delivery
1 trainer
1 set of cables
1 set of hoses
1 CD with software for parameterisation and
configuration of the controllers
1 set of instructional material
1 main circuit pump, 2 external cooling water, 3 collecting tank temperature control,
4 collecting tank, 5 heater, 6 stirred tank, 7 level control valve, 8 pre-heating pump,
9 3-way motorised valve, 10 heat exchanger; F flow rate, T temperature, L level,
LIC controller (level), TIC controller (temperature)
Order Details
080.68200 RT 682 Multivariable Control:
Stirred Tank
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.
Page 3/3
10/2013
RT 682
Available Accessories:
Product no. Order text
080.65060 RT 650.60 Process Control Software for RT 681 and RT 682
G.U.N.T Gertebau GmbH, Hanskampring 15-17, D-22885 Barsbttel, Phone +49 (40) 67 08 54-0, Fax +49 (40) 67 08 54-42, E-mail [email protected], Web http://www.gunt.de
We reserve the right to modify our products without any notifications.