XPTHC-100II Instruction Manual PDF
XPTHC-100II Instruction Manual PDF
,LTD
http://www.hydcnc.com
Instruction Manual
Arc Voltage Torch Height Controller XPTHC-100
Trademark: HYD
Please check this manual fully before use, and contact us for any further explanation
TABLE OF CONTENTS
1Brief Introduction
1.1 It can match almost all plasma cutters. Based on the Constant Current Characteristic of
Plasma power supply, THC monitors the torch height change during cutting process via
detecting the change of plasma Arc Voltage, to reach the aim of controlling the Height
of Cutting Torch.
1.2Basic functions
A Auto Initial Height Sensing(IHS)
Torch Retaining Cap IHS and Proximity Switch IHS (NPN and PNP), Proximity
Switch IHS is backup for Torch Retaining Cap IHS during cutting dirty/rusty
workpiece, needing the Anti-bump fixture designed by us (optional to customer).
The touch-off circuit enables the torch head retract whenever it is in risk of
crashing during cutting.
B Auto Torch Cutting Height Control.
C Display of the Set Arc Voltage and the Actual Arc Voltage:
The Set Arc Voltage and Actual Arc Voltage would be displayed on THC, helping
operator follow work of CNC. We set 30V (adjustable) as Over Arc Voltage
Protection (OAVP) according to our years practice, it is to protect cutting torch on
Kerf Crossing, Corner Turning. When the Actual Arc Voltage is higher than Set
Arc Voltage 30V, Auto Height Control Mode stops to avoid torch head diving.
D Support under-water cutting, on Auto IHS mode
It is our invention of underwater cutting on IHS of Retaining Cap. This function is
optional to customers.
F Lifting torch head on IHS Disabled status.
On IHS Disabled status, jogging torch head down until it reaches workpiece,
when Arc Starts, torch head would lift up automatically to the Set Height set via
the button SET-IHS.
G Lifting on TURN ON or Arc Off:
When CNC is TURN ON or Arc Off, THC would lift cutting torch for 2 seconds,
please notice this Function during commissioning, avoiding the possible damage of
limit switch or lift device.
H.
I.
Manual Operation:
Many functions can be operated on operation panel such as setting Auto/Manual
Up and Down, test of IHS and Arc Start.etc
J.
Auto Operation:
After
Arc
Start
signal
was
given
by
the
CNC,
THC
completes
IHS
2 Specification
y
Input PowerAC24V+5%50Hz/60H z
Output Current1A-4A,
Load capacity100W,
Working temperature-1060
3.2Mode 2 :
When the Arc Start signal (IHS disabled) that connected with CNC is the 5th stitch of the
10-pin aviation socket, THC lifts torch to the height set by Set-IHS, without IHS, driving
plasma start arc directly. When Transfer Arc produced, THC sends Arc Voltage Enable
signal to CNC to start cut. Meanwhile, it delays guiding arc voltage into THC, after that,
if THC is on Auto Mode and the CNC has already sent Auto Height Control signal, then
the THC is on Auto Height Control status
IHS Setting
IHS-Test
Auto/Man Switch
Arc test
Manual UP/Down
Arc Voltage
Before the Arc Start it shows the Set Arc Voltage, after it shows the Actual Arc Voltage.
Set Arc Voltage:
Based on the thickness of steel plate being cut and cutting speed, it shall be set according
to the parameter offered by Plasma, and it will be showed on operation panel. Set Arc
Voltage decides the Torch Height during cut, the higher the arc is, the higher the Torch
Height will be. On Auto mode, adjust the Set Voltage means adjusting the Torch Height.
Set IHS
Set Initial Height, turn clockwise, the height increases; the IHS is reached by Time-Delay.
IHS Test
Every time we dial it up once, it would check IHS one time, which is used to check
whether it is a workable IHS or not.
Set-PIERE:
Set the Delay Time from Plasma Start to CNC starts cut (the arc voltage is delayed to
guide into THC), the Arc Voltage Enable signal would be sent to CNC only after arc
voltage is detected by THC.
Auto/Manual
Set THC s auto or manual mode. Meanwhile enables the Auto Signal between connectors
of CNC and THC, (for EDGE system, the Auto Signal shall be connected as Normally
Closed.)
ARC Test
Dial up and hold on to test the Plasma Arc Start. During test, Torch lifts up an IHS height.
Up/Down
Manual operation button of Up and Down.
ARCON
It is ON means Arc Start is processing, note: the ARCON is off during IHS, if the Arc Start
with IHS Enable, it will turn on only after IHS is completed.
AUTO
On means it is on Auto mode, four conditions have to be satisfied: 1, the Auto signal has
been added on operation panel; 2, the Auto signal connected with CNC system enables; 3,
arc voltage has been guided in THC; 4, Actual Arc Voltage not exceeds Set Arc Voltage
30v. (Note: we usually set as 30v; it can be adjusted through adjustable resistance RP104
6
5 Voltage Divider
5.1 None Isolation Voltage Dividing
The simplest way to divide the plasma arc voltage is None Isolation Voltage Divide by
Resister directly.
Figure2: None Isolation Voltage Divide circuit
Note: The Arc Voltage that goes into THC is electronegative, if the electrode is mis-connected;
the Auto Height Control is inactive.
As None Isolation Voltage Divide is directly connected with Plasma Power Supply, to enable
THC escape from interference caused by the HF during Plasma Arc Start, the Divided Arc
Voltage guided into THC is Time-Delayed.
It just needs to prolong the time of guiding Arc Voltage into THC, this interference can be
avoid effectively.
Voltage Divider can be connected as Isolation Voltage Divide or None Isolation Voltage Divide
mode.
AC220V Input
100
output
connector
Of
None
Isolation
Voltage
Divide
Note: On None Isolation Voltage Divide, AC220V power can be unconnected; but it must be
connected on Isolation Voltage Divide.
The Torch Retaining Cap should be metal, so the metal can be electric with steel plate.
XPTHC-100 has a piece of Isolated IHS plate that can be fixed in the THC directly, the
connection showed as Figure 4 below:
Under Proximity Switch IHS, user needs to use our Anti-bump fixture, introduced on
Figure 12, (This fixture is not included in THC offer, optional to customer).
Proximity Switch IHS is backup for Torch Retaining Cap IHS, for cutting dirty or rusty
steel plate. It can work separately or simultaneously with Torch Retaining Cap. During
cutting dirty or rusty workpiece, if the sensitivity of Torch Retaining Cap is affected,
then Proximity Switch will secure cutting goes properly.
7.
Interface Connection
10
TO-TORCH
TO-CNC
SWITCH-IHS
TO-PLASMA
GND
POWERAC24V
WORK SHIELD
11
12
There are detailed wiring figure at the end of this manual ( Figure 12) shows the
connection of THC control module, Plasma, CNC, Lifter, Torch Retaining Cap IHS,
Proximity Switch IHS.
Attention: Please contact us if you are not sure about your connection, to avoid
damage of PCB of THC, or malfunction.
13
JP3
1
Current
4A
1-8
OFFPWM=9KHZ
3A
2A
ONPWM=18KHZ
1A
2-7
3-6
4-5
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
9Maintenance
9.1Please CONTACT US if you are not sure about solution for follow situation or your
supplier from whom you bought.
15
Serial
Malfunction
Cause
Solution
Number
1
No
display,
black
screen
voltage meter
No rotation of motor
1 damage
of
drive
1replace IR2110
IR2110
2 drive voltage +15V Check drive voltage VCC4
failure
3 protection
of
over-current
or
mechanical
blocked
3
installed
perfectly
NPN
open-circuit condition
Can
not
Start
automatically
Arc
after
the IHS
well
in
the
2 damage of Proximity
Replace
Proximity
switch
switch
signal2mmNPN
1 damage of Proximity
no return signal
5
Instability
of
controlling
arc
voltage
3over-sensitive
Setting
before
the
accomplishment
time
of
of
Arc Start
7
Plasma
Arc
Start
using
the
EXARCON
16
start arc
transfer
to
work
piece
10
down immediately
12
During
IHS,
the
14
15
Cutting
unsteadily
torch
on
is
auto
mode
16
on
auto-state
17
cutting,
voltage
and
Arc
Enable
machine
still
runs
17
9.2Cancel function of Cutting Torch Lift after Arc off,( Please contact us if you are no sure
about it)
The function of Auto Lift would choke the lifting device if the Limit switch not installed yet or
doesn t work properly. So if the CNC has Auto Control function for Up and Down, you can
cancel the Torch Auto Lift function on control PCB.
Cancel the R234 on the control PCB or Cancel the C218 on the control PCB.
We set 30v as Over Arc Voltage Protection (OAVP) according to our years practice, it is to
protect cutting torch from diving during Kerf Crossing; it should NOT be changed before
carefully checking. THC would cancel the function of Auto Height Control if the Actual Arc
Voltage is higher than Set Arc Voltage 30V. So if OAVP is too small, the Auto Height Control
function can not work.
OAVP can be adjusted via adjusting PR104 on control circuit panel. Turn one round clockwise,
4v decreased, anti-clockwise, 4v increased.
Some advice,
1. When Torch Retaining Cap adopted, we suggest customers use Anti-bump Fixer to fix
cutting torch and lifter and connected it with Retaining Cap. In practice, when the contact
between Retaining Cap and workpiece is weak (especially the workpiece is Rusty or Dirty
steel plate,) Proximity Switch takes effect, it is more effective to protect cutting torch. If
Torch Retaining Cap and Proximity Switch both installed, both will be active during cutting.
2. When it is using proximity switch function, we suggest try some more proximity switches,
and all switched by outside circuit.
3. The wire connecting Voltage Divider and THC must be SHIELD cable, and shall be separated
away from Arc Start cable.
4. When the CNC can not receive the Arc Start Enable signal, it should use Time-Delay to run
the CNC. In other word, after CNC sent Arc Start signal, delay the CNC s Running.
18