COD Meter and Multiparameter Photometer

The document describes an 11 parameter photometer and COD meter that measures 44 water quality parameters. It has a light source, detector, and is powered by AC or battery. It measures COD and other parameters and connects to a computer. Reagents and testing methods/ranges are listed.

Uploaded by

Uchuk Pabbola
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

COD Meter and Multiparameter Photometer

The document describes an 11 parameter photometer and COD meter that measures 44 water quality parameters. It has a light source, detector, and is powered by AC or battery. It measures COD and other parameters and connects to a computer. Reagents and testing methods/ranges are listed.

Uploaded by

Uchuk Pabbola
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HI83099

bench

Chemical Oxygen Demand

11 COD Meter and


Multiparameter
Photometer
Easy COD measurement
Outstanding measurement quality
Compact, multiparameter meter
PC compatible
47 methods

The HI83099 is one of the most versatile photometers on the market. In addition
to COD, this meter measures 44 of the most important water quality parameters
using liquid or powder reagents. The amount of reagent is precisely dosed to ensure
maximum reproducibility.
The HI83099 bench photometer can be connected to a PC via a USB cable. The optional
HI92000 Windows Compatible Software helps users manage their data.
The HI83099 features a powerful interactive user support to assist during each step of the
analysis process. A tutorial mode is also available in the setup menu.

Specifications

11.6

HI83099

Light Source

tungsten lamps with narrow band interference filters

Light Life

the life of the instrument

Light Detector

silicon photocell

Environment

0 to 50C (32 to 122F); RH max 90% non-condensing

Power Supply

external 12 VDC power adapter or built-in rechargeable battery

Dimensions

235 x 200 x 110 mm (9.2 x 7.87 x 4.33)

Weight

0.9 kg (2 lbs.)

Ordering
Information

HI83099-01 (115V) and HI83099-02 (230V) is supplied with glass cuvettes with
caps (4), cell protective cap, batteries, 12 VDC adapter, sample preparation kit (for
turbidity or concentrated samples), cloth for wiping cuvettes, 60mL glass bottle for
DO analysis, scissors, and instructions.

www.hannainst.com

Reagent
Code

COD LR

0 to 150 mg/L

dichromate EPA
dichromate mercury-free
dichromate ISO

HI93754A-25
25
25
HI93754D-25
HI93754F-25
25

COD MR

0 to 1500 mg/L

dichromate EPA
dichromate mercury-free
dichromate ISO

HI93754B-25
25
25
HI93754E-25
HI93754G-25
25

COD HR

0 to 15000 mg/L

dichromate

25
HI93754C-25

Water Quality
Test

Range

Method

Reagent
Code

Alkalinity

0 to 500 mg/L (ppm) as CaCO3

bromocresol green

HI93755-01

Aluminum

0.00 to 1.00 mg/L

aluminon

HI93712-01

Ammonia MR

0.00 to 10.00 mg/L

Nessler

HI93715-01

Ammonia LR

0.00 to 3.00 mg/L

Nessler

HI93700-01

Bromine

0.00 to 8.00 mg/L

DPD

HI93716-01

Calcium

0 to 400 mg/L

oxalate

HI937521-01

Chlorine Dioxide

0.00 to 2.00 mg/L

chlorophenol red

HI93738-01

Chlorine, Free

0.00 to 2.50 mg/L

DPD

HI93701-01*

Chlorine, Total

0.00 to 3.50 mg/L

DPD

HI93711-01*

Chromium VI HR

0 to 1000 g/L

diphenylcarbohydrazide

HI93723-01

Chromium VI LR

0 to 300 g/L

diphenylcarbohydrazide

HI93749-01

Color of Water

0 to 500 PCU

colorimetric platinum cobalt

Copper HR

0.00 to 5.00 mg/L

bicinchoninate

HI93702-01

Copper LR

0 to 1000 g/L

bicinchoninate

HI95747-01

Cyanuric Acid

0 to 80 mg/L

turbidimetric

HI93722-01

Fluoride

0.00 to 2.00 mg/L

SPADNS

HI93729-01

Hardness, Calcium

0.00 to 2.70 mg/L

calmagite

HI93720-01

Hardness, Magnesium

0.00 to 2.00 mg/L

EDTA

HI93719-01

Hydrazine

0 to 400 g/L

p-dimethylaminobenzaldehyde

HI93704-01

Iodine

0.0 to 12.5 mg/L

DPD

HI93718-01

Iron HR

0.00 to 5.00 mg/L

phenantroline

HI93721-01

Iron LR

0 to 400 g/L

TPTZ

HI93746-01

Magnesium

0 to 150 mg/L

calmagite

HI937520-01

Manganese HR

0.0 to 20.0 mg/L

periodate

HI93709-01

Manganese LR

0 to 300 g/L

PAN

HI93748-01

Molybdenum

0.0 to 40.0 mg/L

mercaptoacetic acid

HI93730-01

Nickel HR

0.00 to 7.00 g/L

photometric

HI93726-01

Nickel LR

0.000 mg/L to 1.000 mg/L

PAN

HI93740-01

Nitrate

0.0 to 30.0 mg/L

cadmium reduction

HI93728-01

Nitrite HR

0 to 150 mg/L

ferrous sulfate

HI93708-01

Nitrite LR

0.00 to 1.15 mg/L

diazotization

HI93707-01

Oxygen, Dissolved (DO)

0.0 to 10.0 mg/L

Winkler

HI93732-01

Ozone

0.00 to 2.00 mg/L

DPD

HI93757-01

pH

6.5 to 8.5 pH

phenol red

HI93710-01

Phosphate HR

0.0 to 30.0 mg/L

amino acid

HI93717-01

Phosphate LR

0.00 to 2.50 mg/L

ascorbic acid

HI93713-01
HI93706-01

Phosphorus

0.0 to 15.0 mg/L

amino acid

Potassium HR

20 to 200 mg/L

turbidimetric tetraphenylborate HI93750-01

Potassium MR

10 to 100 mg/L

turbidimetric tetraphenylborate HI93750-01

Potassium LR

0.0 to 20.0 mg/L

turbidimetric tetraphenylborate HI93750-01

Silica

0.00 to 2.00 mg/L

heteropoly blue

HI93705-01

Silver

0.000 to 1.000 mg/L

PAN

HI93737-01

Sulfate

0 to 150 mg/L

turbidimetric

HI93751-01

Zinc

0.00 to 3.00 mg/L

zincon

HI93731-01

www.hannainst.com

HI3898

Chloride Test Kit

Quick Chloride Tests


The HI3898 is a chloride concentration
test kit developed according to the
ISO 15705:2002 method.
This very important test is recommended by
ISO, since an excessive presence of chloride
can interfere with the COD analysis.

11

This test gives a fast YES/NO reply to the


question if chloride will interfere with the
COD analysis. If chloride concentration is
greater than the official maximum level, the
solution turns yellow and the sample needs
to be diluted before performing the COD test,
otherwise if the solution is orange-brown,
the sample doesnt need to be diluted.
The maximum level allowed is 1000 ppm
of Cl following ISO methods, or 2000 ppm
of Cl for US EPA, APHA, AWWA and
WEF methods.
Specifications

HI3898

Range

1000 ppm Cl (ISO)


2000 ppm Cl (EPA)

Analysis Method

visual evaluation

Sample Volume

2 mL

Number of Tests

100

Dimensions

120 x 110 x 90 mm
(4.7 x 4.3 x 3.5)

Weight

200 g (7.0 oz.)

bench

Method

Chemical Oxygen Demand

Range

COD Test

Ordering Information
HI3898 is supplied with 25 mL chloride titrant (4),
chloride Indicator 7 mL (1), glass cuvette with
plastic stopper (1) and calibrated syringe with tip (2).

Notes:

Method with chromium-sulfuric acid is officially recognized by EPA for


wastewater analysis.
The HI93754F-25 and HI93754G-25 method follows the official method
ISO 15705.
This method is recommended for general purpose analysis with
no chloride interference.
*
For Chlorine, liquid reagents also available.