0% found this document useful (0 votes)
212 views2 pages

Sound Level Meter Sl-4011

The SL-4011 is a type 2 sound level meter according to IEC 61672. It has features like a large LCD display, max hold function, A and C weighting networks, fast and slow time weighting, AC/DC output, and built-in calibration. The specifications include a measurement range of 30-130 dB, 0.1 dB resolution, 31.5 Hz to 8 kHz frequency response, and AC/DC output signals. It is powered by a 9V battery and has dimensions of 255 x 70 x 28 mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
212 views2 pages

Sound Level Meter Sl-4011

The SL-4011 is a type 2 sound level meter according to IEC 61672. It has features like a large LCD display, max hold function, A and C weighting networks, fast and slow time weighting, AC/DC output, and built-in calibration. The specifications include a measurement range of 30-130 dB, 0.1 dB resolution, 31.5 Hz to 8 kHz frequency response, and AC/DC output signals. It is powered by a 9V battery and has dimensions of 255 x 70 x 28 mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

IEC 61672, type 2

SOUND LEVEL METER


Model : SL-4011

LUTRON ELECTRONIC

ISO-9001, CE, IEC1010

DIGITAL SOUND LEVEL METER


Model : SL-4011
FEATURES
* Large LCD display, easy to read.

* Max. Hold function for stored the maximum value on display.

* Frequency weighting networks are designed to meet the

* Warning indicator for over and under load.

IEC 61672 type 2.

* LCD display for low power consumption & clear read-out even

* A & C weighting networks are conformity to standards.

in bright ambient light condition.

* Time weighting(FAST & SLOW) dynamic characteristic modes.

* Used the durable, long-lasting components, including a strong,

* AC/DC output for system expansion.

light weight ABS-plastic housing case.

* Build in adj. VR is available for easy calibration.

* Small and light weight design allow one hand operation.

* Condenser microphone for high accuracy & long-term stability.

* Low battery indicator.

SPECIFICATIONS
Display

18mm (0.7") LCD (Liquid Crystal Display), 3 1/2 digits.

Function

dB (A & C frequency weighting), Time weighting(Fast, Slow), Max. hold, AC & DC output.

Measurement Range

3 ranges, 30 to 130 dB, input signal only.

Resolution

0.1 dB.

Accuracy

Frequency weighting meet IEC 61672 type 2, calibrating input signal on 94 dB(31.5 Hz to 8

(23 5 )

kHz), then the accuracy of A weighting is specified as following:


31.5 Hz - 3 dB, 63 Hz - 2 dB, 125 Hz - 1.5 dB
250 Hz - 1.5 dB, 500 Hz - 1.5 dB, 1 kHz - 1.5 dB
2 kHz - 2 dB, 4 kHz - 3 dB, 8 kHz - 5 dB
Characteristics of A & C.

Frequency

A weighting - The characteristic is simulated as "Human Ear Listing" response. Typical, if making

Weighting Network

the environmental sound level measurement, always select to A weighting.


C weighting - The characteristic is near the "FLAT" response. Typical, it is suitable for checking the
noise of machinery (Q.C. check) & knowing the sound pressure level of the tested
equipment.

Frequency

31.5 Hz to 8,000 Hz.

Calibrator

B & K (Bruel & kjaer),

multi-fuction acoustic calibrator, model : 4226.

Microphone

Electric condenser microphone.

Size of microphone

1/2 inch standard size.

Range selector

30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step,


with over & under range indicating.

Time weighting

Fast - t= 200 ms, Slow - t = 500 ms,

(Fast & Slow)

* "Fast" range is simulated the human ear response time weighting.

Calibration

* Build in external calibration VR, easy to calibrate by external screw driver.

Output Signal

AC output - AC 0.5 Vrms corresponding to each range step.

"Slow" range is easy to get the average values of vibration sound level.
* Internal oscillation system, 1 KHz sine wave generator.
DC output - DC 0.3 to 1.3 VDC, 10 mV per dB.
Out put impedance - 600 ohm.
Out terminal

3.5 phone output terminal is provided for connection with analyzer, level recorder, tape
recorder.

Operating Temp.

0 to 50 ( 32 to 122 ).

Operating Humidity

Less than 80% RH

Power Supply

006P DC 9V battery(heavy duty type).

Power Consumption

Approx. DC 6mA.

Dimension

255 x 70 x 28 mm (10.0x2.8x1.1 inch).

Weight

280 g/0.62 LB (including battery).

Standard Accessories

Instruction Manual .................................................................. 1 PC.

Optional Accessories

94 dB Sound Calibrator, Model : SC-941.


94 dB/114 dB Sound Calibrator, Model : SC-942.
Hard carrying case, Model : CA-06.

* Appearance and specifications listed in this brochure are subject to change without notice.

0703-SL4011

You might also like