Notebook Combo-Debug-Card (VIP Version) User Guide
Notebook Combo-Debug-Card (VIP Version) User Guide
Copyright: You are not allowed to copy/duplicate/sell this product without authorization
www.etootle.com
www.etootle.com
You can connect this Combo-Debug-Card to any LPC bus. Some LPC interface chips
are listed as below. You can connect the Combo-Debug-Card to the corresponding
pins. For more information, please refer those chips datasheets.
Note: This Combo-Debug-Card uses 3.3V as power supply, and you can use any 3V3 and GND
signals in your notebook main-board. Please be aware that connecting the Combo-Debug-Card to a
non-3.3V power may damage this Combo-Debug-Card.
For IBM X 60 notebooks, the LPC interfaces are located in the U39 slot of the
main-board. The Pin definitions are as below:
A2->LRESET#
A3->LFRAME#
A5->LCLK
A9->LAD3
A10->LAD2
A11->LAD1
A12->LAD0
For IBM T6 R6 notebooks, the LPC interfaces are located in the J26 slot of the
main-board. The Pin definitions are as below:
A1->LCLK,
A3->LFRAME#
B2->LRESET#
B7->LAD3
A7->LAD2
B6->LAD1
A6->LAD0
www.etootle.com
Explanation
C0
Close cache
01
Processor test
07
CMOS test
C1
0A
0C
0D
1A
3C
CMOS setting
42
Initiate hardware
52
FF
Boot
Note
AMI BIOS:
The explanation when the Combo-Debug-Card shows the below debug codes.
Code
Explanation
00
01
0D, 0F
1A 22
3A
FF
Note
7. Q/A
Question: RST indicator is off, but CLK indicator is NOT twinkled.
Answer: This symptom shows there is no CLK signal for debug card so that the CLK
indicator isnt twinkled. Usually, it may mean the motherboard can NOT support this
Mini-PCIe interface. Please use Mini-PCI or LPC interface to test it.
Question: RST indicator is off, and CLK indicator is twinkled. But it shows 00
Answer: In this case, please check the Bus-Type display to check if the Bus-Type
display is corresponding to the bus type.
www.etootle.com