0% found this document useful (0 votes)
227 views

BS 300

The document provides technical specifications for the BS-300 chemistry analyzer. It details the system's functions, throughput, methodology, programming, sample handling, reagent handling, reaction system, interface, and operating conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
227 views

BS 300

The document provides technical specifications for the BS-300 chemistry analyzer. It details the system's functions, throughput, methodology, programming, sample handling, reagent handling, reaction system, interface, and operating conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

BS-300

Chemistry Analyzer

Technical Specifications
System Function:
Automated, discrete, random access for routine, STAT, urine and
homogeneous immuno assays; STAT sample priority
Throughput:
300 tests/hour, up to 420 tests/hour with ISE
Measuring principles: Absorbance photometry, Turbidimetry
Methodology:
End-point, Fixed-time, Kinetic, Single/Dual reagent
chemistries, Monochromatic/Bichromatic, Linear/
Non-linear multi-point calibration
Programming:
User defined profiles and calculation
Sample Handling:
Sample tray:

60 positions for primary or secondary tubes


and sample cups
Sample colume:
2~45l, step by 0.1 l
Sample probe:
Liquid level detection and collision protection
Probe cleaning:
Interior and exterior wash, carry-over < 0.1%
Automatic sample dilution:
Pre-dilution and post-dilution
Dilution ratio up to 3:225
Dilution vessel: Cuvette
Internal bar code reader (optional):
Used for sample programming
Applicable to various bar code systems of code 128,
code 39, code 93, codabar, ITF, UPC/EAN
Capable to link with LIS in a bi-directional mode

Optical System:
Light Source:
Photometer:
Wavelengh:
Resolution:

Halogen-tungsten lamp
Reversed optics, static fiber spot photometry
340, 405, 450, 510, 546, 578, 630, 670, 700nm
0.001 Abs

Control and calibration:


Calibration mode:
Linear (one-point, two-point and multi-point),
Logit-Log 4P, Logit-Log 5P, Splline Exponential 5P,
Polynomial 5P, Parabola
Control software:
X-R, Westguard multi-rule, Cumulative
sum check, Twin plot

Interface:

Reagents Handling:
Reagent tray:
50 positions in refrigerated compartment
(2~10C)
Reagent volume:
10~450L, step by 1L
Reagent probe:
Liquid level detection and collision protection
reagent pre-heating and inventory checking
Probe cleaning:
Interior and exterior washing
carry-over< 0.1%

Mindray is listed on the NYSE under the symbolMR

Rotating tray, 80 disposable cuvettes with


automatic loading
Cuvette:
Optical length 5mm
Reaction volume:
150~500L
Operating temperature: 37 0.1C
Mixing:
Independent mixing bar

Operation Unit:
Operation system:

ISE Module(optional):
Optional selection for K+, Na+, Cl
Throughput:
Up to 180 tests per hour

Mindray Building, Keji 12th Road South,


High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China
Tel: +86 755 8188 8998 Fax: +86 755 26582680
E-mail: [email protected] www.mindray.com

Reaction System:
Reaction rotor:

Windows XP Professional/Home SP2 or above


Windows 7 Home basic 32 bits
RS-232

Working Conditions:
Power Supply:
200~240V, 50/60Hz, 1000W
or 100~130V, 50/60Hz, 1000W
Temperature:
15~30C
Humidity:
35~85%
Water consumption: 3.5 L/hour
Dimension:
980mm x 710mm x 1200mm (W x D x H)
Weight:
186 Kg

is a trademark of Shenzhen Mindray Bio-Medical Electronics Co., Ltd.


2013 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. All rights reserved. Specifications subject to changes without prior notice.

P/N: ENG-BS300-210285x4-20130303

BS-300
Chemistry Analyzer

BS-300

Chemistry Analyzer

Unique and intelligent cuvette

High performance mixer design

loading system

Optimal homogenization in minimum time


Avoid cross contamination

Disposable cuvette to avoid carry-over

Funtion immediately (within the same sampling

Up to 30 segments on board (300 cuvettes)

cycle) after sample or the second reagent

Automated cuvette blank check

Discrete, random access, fully automated

dispensed

Intelligent cuvette loading

300 tests per hour, up to 420 tests per hour with ISE
Internal bar code reader

Up to 50 onboard chemistries and 3 ions

Used for sample programming

Refrigerated reagent compartment


Onboard capacity of 60 sample positions

Refrigerated reagent tray


50 reagent positions for R1 and R2

Applicable to various bar code systems

24 hour non-stop cooling with Peltier

of code 128, code 39, code 93, codabar,

element

ITF, UPC/EAN

Automatic reagent residue volume

Capable to link with LIS bi-directional

monitoring

Automatic probe cleaning, liquid level detection & collision protection


ISE Module
Optional selection for K+, Na+, Cl
Throughput: Up to 180 tests per hour

9 wavelengths: 340~700nm
Automatic dilution for abnormal sample
External hand-held /Internal bar code

Dynamic and real-time display of running status


Running status of sample tray, reagent tray and reaction tray
Real-time monitoring of reagent residual volume and reaction temperature control curve

reader (optional)
Bi-directional LIS interface
Low carry-over

Original reaction data record


Real-time monitoring of reaction curve
Simultaneously display primary and secondary wavelengths to avoid interference
Detailed profile of alert messages
Real-time diagnosis of system working status

Optimum calibration curve


Selection of calibration methods; Factor, Linear, Point to Point, Spline, Log Logit, Exponential

Mindray solution for clinical chemistry

Chemistry Reagents

After more than 10 years of research and development on reagents, Mindray can now provide 48

Hepatic

Lipids

parameters of dedicated reagents(more than 17 others are coming), covering hepatic, renal, cardiac,

Alanine Aminotransferase (ALT)

Total Cholesterol (TC)

lipids, diabetes, pancreatitis, inorganic ions and immunalassays, etc.,together with original calibrators

Aspartate Aminotransferase (AST)

Triglycerides (TG)

Alkaline Phosphatase (ALP)

HDL-Cholesterol (HDL-C)

-GlutamylTransferase (-GT)

LDL-Cholesterol (LDL-C)

Direct Bilirubin (D-Bil) DSA Method

Apolipoprotein A1 (ApoA1)

Direct Bilirubin (D-Bil)VOX Method

Apolipoprotein B (ApoB)

Total Bilirubin (T-Bil) DSA Method

Lipoportein(a) [LP(a)]

with metrological traceability as well as controls for BS-300 chemistry analyzer.

Total Bilirubin (T-Bil)VOX Method

Auto Chemistry
Analyzer

Original Quality
Control

Mindray
solution for
clinical chemistry

Total Protein (TP)

Pancreatitis

Albumin (ALB)

-Amylase (-AMY)

Total Bile Acids (TBA)

Lipase (LIP)

Prealbumin (PA)
Cholinesterase (CHE)

Diabetes

Adenosine deaminase (ADA) *

Glucose (Glu) GOD-POD Method

-L-fucosidase (AFU) *

Glucose (Glu) HK Meth

5'-nucleotidase (5'-NT) *

Hemoglobin A1c (HbA1c)


Fructosamine (FUN)

Renal
Urea (UREA)

Inorganic ions

Creatinine (CREA) Modified JaffMethod

Calcium (Ca)

Creatinine (CREA)Sarcosine OxidaseMethod

Magnesium (Mg)

Uric Acid (UA)

Phosphate Inorganic (P)

Carbon dioxide (CO2)

Original System
Pack Reagent

Original
Calibrators
with Traceability

Original Calibrators with traceability:


Reference Method (Certified by Joint Committee for Traceability in Laboratory Medicine (JCTLM))
International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)

Microalbumin*

Rheumatism

2-Microglobulin (2-MG) *

High sensitivity C-reactive protein (hs-CRP) *

Cystatin C (CysC) *

Rheumatoid Factor (RF)


Antibodies Against Streptolysin O (ASO)

Cardiac
Creatine Kinase (CK)

Immune

Creatine Kinase-MB (CK-MB)

Immunoglobulin A (IgA)

Lactate Dehydrogenase (LDH)

Immunoglobulin G (IgG)

-Hydroxybutyrate Dehydrogenase(-HBDH)

Immunoglobulin M (IgM)

Homocysteine (HCY)

Immunoglobulin E (IgE) *

Myoglobin*

Complement C3 (C3)
Complement C4 (C4)

National Institute of Standards and Technology(NIST)

Ferrum

Centers for Disease Control and Prevention (CDC, USA)

Iron (Fe)

American Association for Clinical Chemistry (AACC)

Ferritin (FER) *

Others

Transferrin (TRF) *

Glucose-6-phosphate dehydrogenase (G6PD) *

Total iron binding capacity / unsaturated ironBinding

D-dimer*

capacity (TIBC/UIBC) *

Angiotensin converting enzyme (ACE) *

Reference Material
Institute for Reference Materials and Measurements (IRMM) standards

C-Reactive Protein (CRP)

National Institute of Standards and Technology (NIST) standards

Retinol binding protein (RBP) *

World Health Organization (WHO) standards

D3-hydroxybutyric acid (D3-HB) *

Japan Committee for Clinical Laboratory (JCCLS) standards

* Coming soon