BS 300
BS 300
Chemistry Analyzer
Technical Specifications
System Function:
Automated, discrete, random access for routine, STAT, urine and
homogeneous immuno assays; STAT sample priority
Throughput:
300 tests/hour, up to 420 tests/hour with ISE
Measuring principles: Absorbance photometry, Turbidimetry
Methodology:
End-point, Fixed-time, Kinetic, Single/Dual reagent
chemistries, Monochromatic/Bichromatic, Linear/
Non-linear multi-point calibration
Programming:
User defined profiles and calculation
Sample Handling:
Sample tray:
Optical System:
Light Source:
Photometer:
Wavelengh:
Resolution:
Halogen-tungsten lamp
Reversed optics, static fiber spot photometry
340, 405, 450, 510, 546, 578, 630, 670, 700nm
0.001 Abs
Interface:
Reagents Handling:
Reagent tray:
50 positions in refrigerated compartment
(2~10C)
Reagent volume:
10~450L, step by 1L
Reagent probe:
Liquid level detection and collision protection
reagent pre-heating and inventory checking
Probe cleaning:
Interior and exterior washing
carry-over< 0.1%
Operation Unit:
Operation system:
ISE Module(optional):
Optional selection for K+, Na+, Cl
Throughput:
Up to 180 tests per hour
Reaction System:
Reaction rotor:
Working Conditions:
Power Supply:
200~240V, 50/60Hz, 1000W
or 100~130V, 50/60Hz, 1000W
Temperature:
15~30C
Humidity:
35~85%
Water consumption: 3.5 L/hour
Dimension:
980mm x 710mm x 1200mm (W x D x H)
Weight:
186 Kg
P/N: ENG-BS300-210285x4-20130303
BS-300
Chemistry Analyzer
BS-300
Chemistry Analyzer
loading system
dispensed
300 tests per hour, up to 420 tests per hour with ISE
Internal bar code reader
element
ITF, UPC/EAN
monitoring
9 wavelengths: 340~700nm
Automatic dilution for abnormal sample
External hand-held /Internal bar code
reader (optional)
Bi-directional LIS interface
Low carry-over
Chemistry Reagents
After more than 10 years of research and development on reagents, Mindray can now provide 48
Hepatic
Lipids
parameters of dedicated reagents(more than 17 others are coming), covering hepatic, renal, cardiac,
lipids, diabetes, pancreatitis, inorganic ions and immunalassays, etc.,together with original calibrators
Triglycerides (TG)
HDL-Cholesterol (HDL-C)
-GlutamylTransferase (-GT)
LDL-Cholesterol (LDL-C)
Apolipoprotein A1 (ApoA1)
Apolipoprotein B (ApoB)
Lipoportein(a) [LP(a)]
Auto Chemistry
Analyzer
Original Quality
Control
Mindray
solution for
clinical chemistry
Pancreatitis
Albumin (ALB)
-Amylase (-AMY)
Lipase (LIP)
Prealbumin (PA)
Cholinesterase (CHE)
Diabetes
-L-fucosidase (AFU) *
5'-nucleotidase (5'-NT) *
Renal
Urea (UREA)
Inorganic ions
Calcium (Ca)
Magnesium (Mg)
Original System
Pack Reagent
Original
Calibrators
with Traceability
Microalbumin*
Rheumatism
2-Microglobulin (2-MG) *
Cystatin C (CysC) *
Cardiac
Creatine Kinase (CK)
Immune
Immunoglobulin A (IgA)
Immunoglobulin G (IgG)
-Hydroxybutyrate Dehydrogenase(-HBDH)
Immunoglobulin M (IgM)
Homocysteine (HCY)
Immunoglobulin E (IgE) *
Myoglobin*
Complement C3 (C3)
Complement C4 (C4)
Ferrum
Iron (Fe)
Ferritin (FER) *
Others
Transferrin (TRF) *
D-dimer*
capacity (TIBC/UIBC) *
Reference Material
Institute for Reference Materials and Measurements (IRMM) standards