CT12 100ex

This document provides specifications for a CT12-100EX 12V 100Ah lead-acid battery. The battery uses lead and lead dioxide plates with dilute sulfuric acid electrolyte immobilized by absorptive separators and plates. Safety valves allow gases to escape during overcharging to prevent pressure buildup. The battery is sealed, maintenance-free and can be used in any position. Key specifications include a 12V nominal voltage, 100Ah capacity at 10-hour rate, 6.3mOhm internal resistance, and operating temperature range of -20°C to 60°C for discharge and -10°C to 60°C for charge. The document also provides detailed performance characteristics, testing results and certifications for the

Uploaded by

Andri Martian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
410 views2 pages

CT12 100ex

This document provides specifications for a CT12-100EX 12V 100Ah lead-acid battery. The battery uses lead and lead dioxide plates with dilute sulfuric acid electrolyte immobilized by absorptive separators and plates. Safety valves allow gases to escape during overcharging to prevent pressure buildup. The battery is sealed, maintenance-free and can be used in any position. Key specifications include a 12V nominal voltage, 100Ah capacity at 10-hour rate, 6.3mOhm internal resistance, and operating temperature range of -20°C to 60°C for discharge and -10°C to 60°C for charge. The document also provides detailed performance characteristics, testing results and certifications for the

Uploaded by

Andri Martian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CT12-100EX12V 100Ah(10hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead

ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

General Features
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin
alloy grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.
Case and cover available in both
standard and flame retardant ABS.
Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

508 / 20.0
110 / 4.33
223 / 8.78
238 / 9.37
28.5 / 62.8

Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life
10 years
Nominal Capacity 77oF(25oC)
10 hour rate (10A, 10.8V)
100Ah
5 hour rate (17.2A, 10.5V)
86.0Ah
1 hour rate (60A, 9.6V)
60Ah
Internal Resistance
6.3mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
900A(5s)
Max. Discharge Current 77 F(25 C)
Short Circuit Current
1700A
o
Charge Methods: Constant Voltage Charge 77 F(25oC)
2.30-2.35VPC
Cycle use
Maximum charging current
30A
Temperature compensation
-30mV/ oC
2.23-2.27VPC
Standby use
Temperature compensation
-20mV/ oC
Discharge Constant Current (Amperes at 68OF20OC)
End Point
10min 15min 30min 45min 1h
Volts/Cell

1.60V
1.65V
1.70V
1.75V
1.80V

3h

5h

10h

207

169

104

75.2

60.0

27.4

18.3

10.2

196
185
175
164

161
152
143
132

99.6
95.1
90.3
85.1

72.2
68.9
65.6
62.5

57.8
55.6
53.2
50.6

26.5
25.5
24.4
23.2

18.0
17.6
17.2
16.7

10.2
10.1
10.1
10.0

Discharge Constant Power (Watts at 68OF20OC)


End Point
Volts/Cell

1.60V
1.65V
1.70V
1.75V
1.80V

10min 15min 30min 45min


366
346
325
303
280

285
271
255
238
221

192
185
178
169
159

143
138
133
127
120

1h

2h

3h

5h

115
111
106
101
94.8

71.6
69.6
67.4
65.2
62.8

54.4
52.5
50.2
47.8
45.5

35.6
34.8
33.8
32.7
31.6

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.

www.vision-batt.com
page1 of 2

CT12-100EX 12V100Ah

Battery voltage(V)

Current

Charged
Volume
140
120

0.25

100

0.20

24.4A17.2A

9.6

80

60.0A

0.15

60

20 30

5
10
min

60

10

20

20

0.05

CHARGED VOLUME

14.0

CHARGE VOLTAGE

13.0

0.10

40
1

15.0

12.0
11.0

10.4

7.8

5.2

2.6

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8

2.4

13.8

9.2

6.9

4.6

2.3

13.2

8.8

6.6

4.4

2.2

CY

STA

CL

ND B

EU
SE

10

12

14

16

Charging time (hours)

18

20

Y US
E

80
70
60

40 o C

30 oC

20 o C

50
0

10
20
30
40
o
Ambient temperature( C)

50

40

60

10

12
14
16
18
20
Storage time: months

Cycle service life in relation to


depth of discharge

Life characteristics of standby use


120
100
Capacity(%)

Capacity(%)

90

100
80
60

Testing conditions: floating voltage: 2.27 to 2.30V/Cell


ambient temperature: 25o C(77 o F)

40

80
60

100% D.O.D.

50% D.O.D.

30% Depth of discharge

40

20
0

110

-10

120

100
Capacity(%)

15.6

Self-discharge characteristic

(V/CELL)

(V/4V)

(V/6V)

(V/8V)

(V/12V)

Relationship between
charging voltage and temperature

15.0

CHARGING CURRENT

Discharge time

20
0

6
Life(year)

10

200

400

600

800

1000

1200

1400

Number of cycles(cycles)

Temperature effects on float life

Temperature effects on capacity

15

120
100

0.1C
0 .2 C

2.30V/Cell

10

Capacity (%)

Life(years)

Constant voltage charge characteristic


(0.25CA, 25o C)

(%) (XCA) (V)

12.0

Charge characteristic curve

Voltage

Discharge characteristic (25 C)

80
60

1.0C
2.0C

40
20

10

20

30

40

50

Temperature( C)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000

MH25860

-20

-10

0
10
20
Temperature( oC)

30

40

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.

Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected]

Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)

Page 2 of 2

50

You might also like