Product Catalogue
UPS and Power
Quality Products
Australia and New Zealand
Contents
Corporate Overview..........................................................................3
3 Phase UPS......................................................................................44
Sustainable by Design......................................................................4
Eaton E Series DX....................................................................................44
Eaton 9355..................................................................................................46
Eaton BladeUPS....................................................................................48
Eaton 9390..................................................................................................50
Eaton 9395..................................................................................................52
About Eaton's Solutions...................................................................5
UPS Solution Overview.............................................................................6
Advanced Technologies...................................................................7
Hot Sync Technology.............................................................................8
ABM Technology....................................................................................9
Intelligent Power Distribution..................................................54
Energy Advantage Architecture Energy Saver System.................10
Aisle containment....................................................................................55
Energy Advantage Architecture Variable Module
Management System..............................................................................11
Rack containment....................................................................................56
Enterprise-class racks............................................................................57
Rack accessories.....................................................................................57
Series 3 Single Phase UPS.............................................................12
Eaton 3S.....................................................................................................12
Eaton Ellipse ECO.....................................................................................13
Series 5 Single Phase UPS............................................................14
Eaton E Series NV....................................................................................14
Eaton Ellipse Max.....................................................................................15
Intelligent Power Software Suite............................................58
Options to Manage and Monitor Your UPS................................59
Eaton's Power Xpert Architecture....................................................60
Power Management................................................................................61
Eaton 5110..................................................................................................16
Surge Protection Devices..............................................................64
Eaton 5115..................................................................................................18
Eaton Evolution.........................................................................................20
Surge Protection Equipment Overview................................................64
Eaton 5130..................................................................................................22
Eaton POD & POD+..................................................................................65
Eaton 5PX..................................................................................................24
Series 9 Single Phase UPS............................................................26
Airflow management and racks...................................................55
Eaton E Series DX....................................................................................26
Eaton EX.....................................................................................................28
Eaton 9130 Tower......................................................................................30
Power Conditioners........................................................................66
Sola Power Conditioners........................................................................66
Sola 200/210...............................................................................................67
Sola 200......................................................................................................68
Sola 26 Multivolt.......................................................................................69
Eaton 9130 Rack.......................................................................................32
Protecting your investment...........................................................70
Eaton 9135..................................................................................................34
Service.......................................................................................................70
Eaton 9140..................................................................................................36
Eaton EX RT...............................................................................................38
Eaton 9155..................................................................................................40
Eaton MX & MX Frame...........................................................................42
EATON CORPORATION UPS and Power Quality Products Catalogue
Eaton Warranty Plans..............................................................................71
Corporate overview
Powering Business Worldwide
Founded in 1911, Eaton Corporation is a diversified industrial manufacturer and a global leader in
various industrial markets, including:
Electrical systems and components for power quality, distribution and control
Hydraulics components, systems and services for industrial and mobile equipment
Hydraulics, fuel and pneumatic systems for commercial and military aircraft
Intelligent truck drivetrain systems for safety and fuel economy
Automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety
With 2010 sales of $13.7 billion USD, Eaton has approximately 70,000 employees worldwide
and sells products to customers in more than 150 countries.
www.eaton.com/powerquality 1300 UPS UPS
Sustainable by Design
Sustainability has always been at the heart
of Eaton's business this means meeting the
current needs of our society while enabling
future generations to meet their own needs.
Sustainable design for our products means
helping our customers utilise electrical power
more efficiently while significantly improving
environmental performance.
At Eaton, we apply the ISO 14001, an international environmental
management system, on site and R&D certification to all of our facilities.
In addition, to clearly demonstrate and communicate the environmental
value of the products to customers and consumers, Eaton has developed
a rigorous evaluation process based on the guidelines of international
organisations such as the International Standards Organisation (ISO).
Eaton products and services meeting the environmental standards of this
process earn the Eaton Green Leaf label. Though all of our products
are designed to meet government standards and public expectations
for protecting the environment, Green Leaf products and solutions
go well beyond normal standards to provide exceptional benefit to our
customers and the environment.
We also care for the way our parts and materials are supplied. Eaton is
a part of Green Suppliers Network, a network that helps its component
suppliers to develop Lean and Clean manufacturing processes that
result in reduced waste and saved money, all while reducing their
impact on the environment.
For more information on how Eaton is Sustainable by Design, please visit
www.eaton.com/sustainability.
EATON CORPORATION UPS and Power Quality Products Catalogue
About Eaton's Solutions
Eaton offers the largest selection
of power management and
protection solutions available in
the industry. From the desktop to
the data centre, from AC-powered
to DC-powered equipment, Eaton
is your one-stop partner for all
your power needs.
Eaton's Power Quality solutions provide the confidence that power
problems will not disrupt your systems, data and operation. Delivered
through more than 50 years of solid performance, in-depth knowledge
of customer applications, continuous innovations and world-class
services. Eaton solutions have been recognised by UPS users and
industry experts for delivering highest customer value and satisfaction,
as well as for demonstrating most insight into customer needs among all
UPS vendors.*
Eaton product and service range
* Frost & Sullivan Award for Customer Value and Satisfaction and Frost
& Sullivan Award for Product Line Strategy.
Technical support and maintenance
AC UPS from 550VA up to 3500 kVA
DC systems of all sizes
A broad portfolio of rack-based power distribution
units (ePDU)
IT rack enclosures, airflow management and heat containment systems
Software and connectivity products for power management and
remote control
Complete power quality solutions
Eaton products are manufactured in factories located in Finland, USA,
China, Taiwan, India, UK and New Zealand.
www.eaton.com/powerquality 1300 UPS UPS
UPS Solution Overview
Selecting the Right UPS
Series 3, Series 5 and Series 9. Based on the parameters defined by your
application, you can select an uninterruptible power system (UPS) from
the series that best matches your power protection needs.
Eaton's power management solutions are based on protecting the
nine most common power problems present in any environment. This
unique approach makes your product selection decisions about power
protection much simpler. The nine power problems listed below are
potentially harmful to both your data and your hardware. Eaton's
products offer three levels of power protection:
To provide maximum power protection, Eaton offers a full line of Series
9 UPSs with both single-phase and three-phase models in the Series 9
family.
Within each Series, Eaton has created 3 classes of products; Essential,
Superior and Premier, to provide "Good, Better and Best" levels of
features and performance and enable the best product fit for any
application and budget.
Standby UPS: Backup power
Power Failure
Power
Sag
Power
Surge
AC to DC
Rectifier
The Eaton's series 3 UPS primarily protects against three of the nine power problems
including power failures, power sags and power surges. This essential, cost-effective
protection is necessary in order to prevent damage such as data loss, file corruption,
hardware damage and equipment shutoff. For example, if your utility fails you could lose
all of your work-in-progress. The Series 3 UPS offers a degree of protection against the
remaining power problems and is most commonly used to protect single workstations and
point-of-sale (POS) equipment.
DC to AC
Inverter
Battery
Buck Boost
Line Interactive UPS: Keeping it smooth
AC to DC
Rectifier
AC to DC
Rectifier
DC to AC
Inverter
DC to AC
Inverter
Battery
Battery
Buck Boost
Power Failure
Power
Sag
Power
Surge
Undervoltage
Internal Static Bypass
Overvoltage
Eaton's series 5 UPS are most effective against five power problems (power failures, power
sags, power surges, under-voltage and over-voltage) and offer a degree of protection
against other power problems. Some of the damages you risk by not using a Series 5 UPS
include premature hardware failure, data loss and corruption, data error, keyboard lockup,
storage loss and system lockup. Series 5 UPSs are recommended for small network systems
- all the way up to enterprise networking environments.
AC to DC
RectifierAC to DC
Rectifier
DC to AC
Inverter
DC to AC
Battery Inverter
Battery
AC to DC
Rectifier
DC to AC
Inverter
Battery
Internal Static
Bypass
AC to DC
Rectifier
Buck Boost
On Line Double Conversion UPS: Total Protection
DC to AC
Inverter
Battery
AC to DC
Rectifier
Power
Failure
Power
Sag
Power
Surge
Undervoltage
Overvoltage
Line
Noise
Frequency
Variation
Eaton's series 9 UPSs protect against all nine power problems: power failures, power
sags, power surges, under-voltage, over-voltage, line noise, frequency variation,
switching transients and harmonic distortion. Eaton's series 9 comprehensive
protection minimises the opportunity for component stress, burnt circuit boards,
data crashes and program failures. Series 9 UPSs offer the highest level of power
protection available and are always recommended for mission-critical applications
like server farms, hospitals and Voice Over Internet Protocol (VOIP) applications.
EATON CORPORATION UPS and Power Quality Products Catalogue
Switching
Transient
DC to AC
Inverter
Battery
Harmonic
Distortion
Internal Static Bypass
AC to DC
Rectifier
DC to AC
Inverter
Battery
Advanced Technologies
Eaton has been developing its innovative
technical solutions in the power protection
field since receiving its first patent in 1962. As
a technology leader Eaton meets the customers
fast growing needs with advanced patented
technologies.
Eatons three-phase UPS products are based on the same technical
platform, including a similar internal topology, common control hardware
and algorithms, standardised communications capabilities and a
common user-interface.
Single platform benefits
UPS units behave in a uniform way and carry
similar features
Product upgrades are easier as the process
is identical
Improved service capabilities due to usage of
common spare parts and accessories across
product families and standard service tools
Similarity of service training and documentation
guarantee that customers in all countries receive
the same high level of service
Lower total cost of ownership
Transformer-free
Technology
The transformer-free technology used in Eaton UPSs with small and
lightweight filter inductors, high performance IGBTs in both inverter and
rectifier, and advanced control algorithms brings improved performance
and value. Compared to legacy UPS topology designs, a transformer-free
UPS is typically only 50% the weight and occupies just 60% the footprint.
Low input THD (<5% at full load) and high input power factor (>0.99) are
supported down to nearly 10% load without the need for an additional
input filter. In addition, full load efficiency can reach 94.5% and above.
User benefits
High efficiency
Less weight
Smaller footprint
www.eaton.com/powerquality 1300 UPS UPS
Hot Sync Technology
The number one function of a UPS is to supply continuous conditioned,
reliable electricity to critical loads. In the case of a single unit, reliability
can be increased by modular design, where redundant internal modules
can take over each others tasks, if one of the modules fails. To further
increase reliability, a true parallel configuration can be employed,
where two or more units share the load. A failed unit is isolated while
the remaining ones continue to support the critical load. Competitive
UPS products on the market utilise centralised or distributed load
sharing technology with a Master-Slave principle, which introduces
a risk of single point failure. The absolute reliability of a UPS system
can be reached with patented Eaton Hot Sync parallel load sharing
technology. (Figure 1)
Hot Sync technology is designed for parallel redundant N+1 systems to
User benefits
Available for both single and three-phase products to meet any
mission-critical need up to 3.5 MVA (400V) systems
Easy and modular parallel UPS system upgrade with additional
capacity or redundancy
Eliminates single point of failure
satisfy 24/7 applications. It can also be used in parallel capacity systems
to benefit from scalability for customers' ever-increasing load demands.
Hot Sync eliminates single point of failure, with the ability to
Hot Sync
20%
synchronise and support critical loads independently of other UPS
modules in the system. UPS modules can share loads without any
communication wiring to the outside world.
Failure probability / year
The secret here is a patented built-in digital signal processor (DSP)
algorithm, running continuously in each unit. It drives the UPS outputs
toward synchronisation and takes care of load sharing. If there is a
common bypass available, it is used as valid synchronisation source for
output. In the absence of common bypass, the processor makes subtle
adjustment to the inverter frequency on the basis of output power level
measurement in order to find a common frequency and load balance
among the units. There exists, as shown in Figure 2, a relationship
between the power imbalance and the voltage phase difference.
Hot Sync technology allows full maintenance to be performed one-by-
Utility
No common logic
Single UPS
Modular UPS
Parallel redundant UPS
Hot Sync
10%
99,99%
99,999%
99,9999%
Figure 1. Patented Hot Sync technology provides the highest availability for
load.
one on redundant UPS modules without an external maintenance bypass
switch. The critical load does not need to be disconnected from the
conditioned power. Scheduled or unscheduled maintenance can
be perfomed with the load supported continuously by the UPS-grade
clean power.
UPS 1
f1
UPS 2
f2
P1
P2
P1
P1+2
P2
Power level difference diminishes
Frequencies are continuously
adjusted based on P1 and P2
Voltages out of phase
Outputs are synchronised
VUPS 1
VUPS 2
Parallel Output, Load Bus
Figure 2. Well-balanced load share is achieved by adjusting output frequencies;
thus the phase difference between parallel UPS output voltages is forced to zero.
EATON CORPORATION UPS and Power Quality Products Catalogue
ABM Technology
Battery service life is a major contributor to UPS reliability. Since
batteries are electro-chemical devices, their performance gradually
decreases over time. Premature wear-out means higher costs in terms
of replacement labour and shorter service cycle. A worn battery entails
a risk of unexpected load loss. In normal UPS operation, back-up power
is needed only occasionally and the battery wearing rate depends
strongly on how the full charge is being maintained. Excess charging is
detrimental under any operating circumstances.
Eaton has created ABM Technology to extend the life of valve
regulated lead-acid batteries by applying sophisticated logic to the
charging regime. Using traditional trickle charge method, batteries
become subject to electrode corrosion and electrolyte dry-out,
especially in standby service use due to continuous float charging.
ABM is essentially an addition of intelligence to the charging routine
by preventing charging when it is not necessary, thus significantly
retarding wear-out. ABM provides an additional feature for monitoring
battery condition and advance warning about the end of battery life upon
detection of a weak battery. Also, it optimises the recharge time, which
is advantageous when there may be consecutive power outages within
a short period. ABM has been used for over fifteen years in our UPSs
ranging from 1 to 160 kVA and is now applied in UPS' up to 1100 kVA.
ABM cycle and operation how does it work?
The basic idea about ABM is to leave a fully charged battery in rest
mode for most of the time, and then apply charge current only at certain
intervals. Initially, in order to charge up a fully or partly discharged
battery, the charger starts at a constant current appropriate for the
battery type used. When the battery voltage reaches a set level
the operation is changed to float mode using a constant but lower
voltage, thus providing an optimum recharge time. The battery is kept
at this voltage for 24 hours until it comes to the first test point. This
takes approximately one minute and during this period voltage drop
measurements are taken while loading the battery, giving an indication
of battery condition. The float charging is continued for an additional
24 hours, plus a period equal to 1.5 times the constant current charging
time, before the rest mode is initiated. At this point, the charging is
discontinued for a maximum of 28 days as if the batteries were
Battery voltage during ABM charging process.
User benefits
Predictive and automatic diagnostics of Battery Health
Significant extension of battery life compared
to traditional charging method
Optimisation of battery recharging time
with dual mode charging method
Automatic battery charge voltage compensation within
0 to +50C temperature range
disconnected. During the first 10 days the battery voltage is continuously
monitored, and if it drops below 2.1 V/cell, the ABM re-starts in charge
mode and the user gets a notification of improper battery operation. If
it drops below this limit after the 10 day period, charging is resumed
without alarm. In short, the algorithm uses three charging stages in its
operation. Thus, the batteries experience much less stress than in the
case of traditional charging. A typical battery charging cycle without
power interruptions is shown in the graph below.
ABM technology significantly increases battery service life
www.eaton.com/powerquality 1300 UPS UPS
Energy Advantage Architecture Energy Saver System
Energy Advantage
Architecture (EAA)
The rising demand for highly available, reliable and efficient power is a
continuous challenge for data centre operators. Higher energy efficiency
helps to address increasing environmental, regulatory and economic
pressures.
Eaton has developed innovative and proprietary technologies that
improve system efficiency without compromising on reliability under the
Energy Advantage Architecture (EAA) umbrella.
ESS allows for market leading 99 percent efficiency
Energy Saver System (ESS) is one of these technologies.
Maximised energy efficiency
With 85% reduction in UPS energy losses, ESS technology dramatically
reduces energy consumption, environmental impact and power costs
without compromising load protection. Those outstanding energy savings
typically recovers 100% of the UPS cost over a 3 - 5 year period.
across the entire operating range. Compared to conventional eco-mode
capabilities available with legacy products, ESS offers the best possible
efficiency and the fastest transition times to double conversion when
power disturbances occur.
No compromise on reliability
In ESS mode the UPS safely provides mains current directly to load when
the input is within the acceptable limits by its voltage and frequency. If
input power goes outside the preset limits by frequency or voltage, the
UPS switches to double conversion.
If input power is outside the tolerances of the system, the UPS draws
power from available battery modules.
Superior detection and control algorithms continuously monitor incoming
power quality and allow the UPS to engage power converters in less
than two milliseconds time when utility source goes out of pre-defined
limits by its voltage or frequency, thus always providing secured power
to the critical load while maximising efficiency. In case of UPS detecting
a fault condition while operating in ESS, the UPS is capable to detect and
determine whether the fault is caused by load or if it is upstream from
the UPS. A fault at the bypass source results in immediate switchover to
the inverter; a fault in the load keeps the UPS in Energy Saver System.
Proven Eaton technology ensures reliability and continuous load
availability without compromising the protection of the supported
equipment.
Extensive configurability
Eaton UPS with Energy Saver System features three configurable modes
of operation:
Standard double conversion mode: the UPS operates as normal,
supplying power through the power converters
Energy Saver System: the power converters are in ready state and the
static bypass switch allows the UPS to supply mains power directly
High Alert mode: the UPS automatically transfers from ESS to double
conversion and in case of multiple reoccurring utility line disturbances
it stays there for preconfigured time (default 1 hour) until it is safe to
return to ESS
UPS seamlessly executes transitions through different operating modes
as needed. This is only possible with transformer-free topologies.
Availability
ESS is available to all 9390 and 9395 UPSs. Also parallel UPS systems
support operation in ESS mode. All earlier made installations can be
upgraded with ESS capability.
10
EATON CORPORATION UPS and Power Quality Products Catalogue
Energy Advantage Architecture Variable Module Management System
Variable Module
Management System
(VMMS)
Variable Management Module System (VMMS)
is a key component of Energy Advantage Architecture. Eaton VMMS
technology maximises UPS efficiencies at low load levels while
supplying the load with continuous double-conversion power. Most UPS
installations are only loaded between 20-40%, but UPSs are not optimally
efficient when used at these lighter loads.
Existing method for increasing load percentage
The existing approach to capturing efficiency from low load levels
applied only to multi-UPS parallel systems. The system can increase
the effective load percentage by putting entire UPSs into idle. While
this helps improve efficiency slightly, it is limited to multi-UPS parallel
systems, and flexibility to adapt to the load can only be done in the large
steps of full UPS capacity.
The VMMS way
VMMS optimally employs UPMs to achieve higher efficiencies in doubleconversion mode in order to maximise the load level on remaining
active UPMs by setting UPMs that are not needed to ready state.* This
is calculated according to VMMS load threshold of the UPMs 80% by
default and the system configuration (redundancy requirements). This
results in maximised energy savings.
VMMS is possible thanks to Eaton 9395 UPS modularity, and VMMS
applies even in single-UPS systems. Upon a load increase on critical
bus, all ready state UPMs are able to react quickly and revert to doubleconversion mode in less than 2 ms by connecting the existing PWM
signals to the IGBT gates.
Extensive Configurability
Customers can decide how to configure their system
establishing the number of redundant UPMs and the
maximum load level per UPM.
VMMS can be used in single (multiple-UPM), and multi-UPS
9395 systems
Single 9395 units from 550 kVA to 1100 kVA
Distributed parallel systems (Xx275, Xx550, Xx825, Xx1100)
SBM centralised bypass system
Earlier installations can also be upgraded with VMMS
Applications
Applications where VMMS is particularly efficient:
Redundant N+1 and 2N systems Lightly loaded: <45% load level
Critical data centres, especially when UPS feeds dual corded servers
Any applications where load varies frequently
Availability
ESS is available to all 9390 and 9395 UPSs. Also parallel UPS systems
support operation in ESS mode. All earlier made installations can be
upgraded with ESS capability.
www.eaton.com/powerquality 1300 UPS UPS
11
Superior series 3 power protection for office and home computer equipment
Eaton 3S
In the event of a total blackout, the unit provides sufficient battery
backup time to last through most power outages
The 700VA model saves up to 30% energy through its EcoControl
function which automatically disables peripherals when the master
device, such as a computer, is turned off
The 3S also protects telephone, broadband and Ethernet line from
back door power surges
The shutdown software makes it possible to automatically save your
work and shut down your application without losing any data. Once the
power is restored, you can continue working exactly where you left off
Easy integration and installation
Attractive design and glossy finish make the 3S a perfect fit for the
modern office environment
The 3S comes with a fixed input cable and 6 Australian outlets for easy
connection of typical computer configurations with peripherals
The 3S features a HID-compliant USB port (cable supplied), for
automatic integration with common operating systems (Windows/Mac
OS/Linux)
Compact unit fits on or under your desk or can be mounted on a wall
Technology: Series 3 (Standby)
Rating: 550 & 700VA
Voltage: 240Vac
Backup time: Typical 5 min
Configuration: Powerboard style
Easy-to-replace battery helps to extend UPS service life
Ideal for protecting
Computers and peripherals
Protection against power problems
The Eaton 3S UPS helps to protect your computer equipment in case
of everyday events such as lightning strikes, storms, over-demand on
the utility grid, accidents, and natural disasters knocking out power
without warning
Broadband modems (internet and TV)
IP telephony equipment
POS equipment
Eaton 3S Technical specifications
Rating (VA/W)
550VA / 330W
700VA / 420W
Model numbers
3S550AU
3S700AU
Output connection
3 x Aust 3 Pin 10A outlets with battery backup and surge protection + 3 x Aust. 3 Pin 10A outlets with surge protection
Characteristics
Input voltage
Up to 161-284 V (adjustable)
Output voltage
240 V (settable to 220 V, 230 V or 240 V)
Frequency
50-60 Hz autoselect
Input protection
Resettable circuit breaker
Features
ECO Control
No
Line protection
Tel/fax/modem/internet/Ethernet
Yes
Battery
Battery type
Compact, sealed lead-acid (replaceable)
Battery test
Yes
Yes
Cold start (no mains power)
Yes
Yes
Deep-discharge protection
Yes
Yes
Battery replacement indicator
LED
LED
Runtime at 50% load
10 min
9 min
Runtime at 70% load
6 min
6 min
Communication
Communications port HID-compliant USB port for automatic integration with most common operating systems. USB cable supplied
Standards compliance
Safety/EMC
IEC 62040-1, IEC 60950-1, IEC 62040-2, CB Report, CE mark, C-Tick, A-Tick
EMC
IEC 62040-2, C-Tick
Dimensions and weight
Dimensions H x W x D
86 x 140 x 335 mm
86 x 170 x 335 mm
Weight
2.9 kg
3.8 kg
Warranty
3 year limited warranty on UPS, 2 year limited warranty on battery and $25,000 Load Protection Guarantee.
Warranty+
Optional Warranty Uplifts
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
12
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier series 3 UPS with Advanced Surge Reduction
Eaton Ellipse ECO
Technology: Series 3 (Standby)
Rating: 650 / 800 / 1200 / 1600VA
Voltage: 230V
Backup Time: Typical 5 min
Configuration: Rack/Tower
Ideal for protecting
Computers and Peripherals
Broadband Modems
IP Telephony Equipment
POS Equipment
Energy-efficient power protection for business computers
With an efficient electrical design and the EcoControl function, which
automatically disables peripherals when the master device is turned
off, the Eaton Ellipse ECO helps you make energy savings of up to 30
per cent compared to previous-generation UPSs
As well as providing a power supply backed up by a battery to keep
equipment operating during a power failure, the Ellipse ECO also
provides effective protection against damaging surges
The Ellipse ECO includes a high performance surge-protection
device that complies with IEC 61643-1, this device also protects data
connections such as Ethernet, internet and telephone lines
Easy integration and installation
The Ellipse ECO comes with either four (650/800 models) or eight IEC
outlets (1200/1600 models). Two IEC to IEC and two IEC to Aust 3 pin
adaptor cables supplied
The Ellipse ECOs extra-flat design makes it easy to install in any office
environment: installation options include vertical box format, below the
desk, horizontally under a monitor, 19 rack-mounted (optional 2U kit)
and wall-mounted (optional kit)
The Ellipse ECO is designed to be compatible with a wide variety of
different computer models. Eaton power management software is
delivered as standard (CD and USB cable supplied) and is compatible
with all major operating systems (Windows 7, Vista, XP, Linux and
Mac OS)
Complete peace of mind
Periodic battery self-test ensures early detection of a battery that
needs to be replaced
Easy-to-replace battery helps to extend UPS service life
Push-button circuit breaker enables easy recovery from an overload or
short circuit
Eaton Ellipse ECO Technical specifications
Rating (VA/Watts)
650VA / 400W
800VA / 500W
1200VA / 750W
1600VA / 1000W
Model Numbers
EL650USBIEC
EL800USBIEC
EL1200USBIEC
EL1600USBIEC
Outlets with surge and backup / outlets with surge only
3 / 1 (IEC C13 10A)
3 / 1 (IEC C13 10A)
4 / 4 (IEC C13 10A)
4 / 4 (IEC C13 10A)
Cables
Input cable, 1 x IEC-IEC 10A output cable and 2 x IEC to Aust 3 Pin output adaptor cables included
Characteristics
Nominal Input Voltage
230V
Output Voltage
230V Adjustable to 220 / 230 / 240
Frequency
50 60Hz (Autoselect)
Input Protection
Resettable Circuit Breaker
Features
ECO Control
Yes up to 30% energy savings
Line Protection
Telephone/Fax/Modem/Internet/Ethernet
Battery
Battery Type
Replaceable Sealed Lead Acid
Cold Start
Yes
Deep Discharge Protection
Yes
Battery Replacement Indicators
LED and Audible
Runtime at 50% load
9 min
11 min
10 min
11 min
Runtime at 70% load
6 min
6 min
6 min
6 min
Communication
Communications port HID-compliant USB port for automatic integration with most common operating systems. USB cable included.
Standards
Safety/EMC
IEC 62040-1, IEC 60950-1, IEC 62040-2, CB Report, CE mark, C-Tick, A-Tick
Surge Protection
IEC 61643-1
Dimensions (H x W x D)
263 x 81 x 235
263 x 81 x 235
305 x 81 x 312
305 x 81 x 312
Weight
3.6kg
4.1kg
6.7kg
7.8kg
Customer Service and Support
Warranty
3 year limited warranty on UPS, 2 year limited warranty on battery and $25,000 Load Protection Guarantee
Warranty+
Optional Warranty Uplifts
Accessories
19" Rack Kit (ELRACK), Wall Mount Kit (ELWALL)
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
13
Essential series 5 Power Protection
Eaton E Series NV
The E Series NV line interactive uninterruptible power system (UPS)
provides affordable power protection for your personal computers,
home, office and other electronic devices. While packed with valuable
features such as plentiful power receptacles and USB communications,
the compact size is ideal for limited office and home working spaces.
Features
Automatic Voltage Regulation (AVR) stabilises fluctuating
power sources
Microprocessor control design ensures high reliability
Up to four receptacles, allowing easy equipment connection
User replaceable batteries allow easy maintenance
Start-on-battery provides portable power capability
WINPOWER software monitors power conditions and gracefully shuts
down computer applications prior to battery depletion
Intuitive LED indicators display UPS status
Technology: Series 5 (Line Interactive)
Rating: 600 / 800 / 1000 / 1400 / 2000VA
Voltage: 240V
Backup Time: Typical 5 min
Configuration: Tower
Ideal for protecting
Computers and Peripherals
POS Equipment
E Series NV Technical Specifications
Technology
Line Interactive (Automatic Voltage Regulation)
Rating, VA/Watts
600VA / 360W
800VA / 480W
1000VA / 600W
1400VA / 840W
2000VA / 1200W
Model Numbers
ENV600HA
ENV800HA
ENV1000HA
ENV1400HA
ENV2000HA
Characteristics - input/output
Input Voltage Window
177-290
Output Voltage on Battery
240V
Frequency
50/60Hz, auto detection
Output receptacles
2 x Aust 3 pin 10A sockets
Input Connection
1.8m Input Cable included
4 x IEC C13 10A Sockets (1 IEC-IEC Output cable included)
Battery/run time
Load
100W
18
22
35
45
45
120W
14
17
200W
14
25
25
400W
10
10
600W
Start-On-Battery
Unit can be started without being connected to AC utility power
User Interface
Visual
1 On / Off button, 1 indicator LED
Audible
Five audible alarms indicate operating modes
1 On / Off button, six indicator LED's, including load level
Communications / management
Power Management Software
WINPOWER power management software, downloadable via internet
Connection Type
USB port, USB cable included
Approvals
CE marking
Dimensions and weights
205 x 145 x 385 mm
Dimensions (H x W x D)
140 x 100 x 330 mm
Weight
6 kg
Warranty
2 year limited warranty + 3 year pro-rata warranty and $25,000 Load Protection Guarantee.
6.5 kg
9.6 kg
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
14
EATON CORPORATION UPS and Power Quality Products Catalogue
10.5 kg
10.6 kg
Superior series 5 protection for workstations and small servers
Eaton Ellipse Max
Availability
Line Interactive technology: Ellipse MAX provides effective protection,
even in disturbed electrical environments. Fluctuations in voltage are
automatically corrected by an AVR device (booster/fader), without using
the batteries.
Surge protection: Ellipse MAX includes a high performance surge
protective device which complies with IEC 616431 standard
Robust: A wide tolerance of input voltage avoids excessively frequent
changeover to battery power
This means that maximum capacity is always available. The thresholds
for changeover to battery power can be adjusted using the supplied
Solution-Pac software.
Flexibility
Connection: 4 or 8 standard IEC outlets supplied with 2 IEC to AUST
adaptor leads
Integration: Ellipse MAX can be installed in vertical position over &
under the desk, or horizontally under a monitor
Rackable: the optional 2U kit allows you to install the Ellipse MAX in a
19 rack
Power management: Ellipse Max features a combined USB and
serial port
Technology: Series 5 (Line Interactive)
Rating: 600 / 850 / 1100 / 1500VA
Voltage: 230V
Backup Time: Typical 5 min
Configuration: Tower/Rack
Ideal for protecting
Computers and Peripherals
Workstations
Small Servers
POS Equipment
Ellipse Max Technical Specifications
Rating, VA/Watts
600VA / 360W
850VA / 550W
1100VA / 660W
1500VA / 900W
Model Numbers
ELMi600T-USB
ELMi850T-USB
ELMi1100T-USB
ELMi1500T-USB
Characteristics - input/output
Input Voltage Window
165 V - 285 V (adjustable to 150V - 285 V)
Surge Protection
Integral surge protection device to IEC 61643-1, Total surge absorption: 525 Joules
Output Voltage on Battery
230 V (adjustable to 220 V - 230 V - 240 V)
Frequency
50/60Hz, auto detection
Output receptacles with Backup & Surge Protection
3 / 1 (IEC C13 10A)
Output cables
2 x IEC to Aust 3 Pin 10A adaptor cables included
4 / 4 (IEC C13 10A)
4 / 4 (IEC C13 10A)
4 / 4 (IEC C13 10A)
Battery/run time
Battery Management
Battery test, Cold start (no mains), Deep discharge protection
Typical backup times for 50 and 70% of the VA rating
12 / 7
Battery Replacement Indicators
LED + Audible Alarm
18 / 12
15 / 9
12 / 7
User Interface
Visual
Illuminated On/Off button, 3 x LED (Surge Protection Active, UPS Fault, Overload)
Audible
Audible alarm for On Battery condition. Alarm can be deactivated
Communications / management
Power Management Software
Communications port HID-compliant USB port for automatic integration with most common operating systems
(Windows XP, Vista and 7, Linux, Mac OS X), cable supplied
Connection Type
Combined USB & Serial port, with included USB cable
Standards/Approvals
IEC/EN 60950-1, IEC/EN 62040-1-1, IEC / EN 62040-2 C1, IEC 61643-1, CB Report, CE mark, C-Tick
Dimensions and weights
Dimensions (H x W x D)
314 x 82 x 301 mm
314 x 82 x 410 mm
314 x 82 x 410 mm
314 x 82 x 410 mm
Weight
5.75 kg
10.2 kg
10.2 kg
10.2 kg
Warranty
2 year limited warranty + 3 year pro-rata warranty and $25,000 Load Protection Guarantee
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
15
Superior series 5 power protection for office servers
Eaton 5110
Product highlights:
Protects loads on six outlets - three with surge suppression and battery
backup, three with surge suppression only
Delivers consistent, clean output with automatic voltage regulation
(AVR) that doesn't drain battery power
Phone line transient protector guards phone equipment from "back
door" power surges
Stay informed of power problems and low battery conditions with
audible alarms and remote alarm notification via e-mail, pager or
the Web
USB port and cable are standard
Two year full warranty, plus three year pro-rated warranty and $50,000
load protection guarantee
Extend UPS service life with user-replaceable batteries
Deliver short-term mobile power with start-on-battery capability
Save space with a compact design that can be deployed as a tower,
under a computer monitor or in a rack
Options:
Extended warranty plans
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 5 (Line Interactive)
500-1500VA
240 Vac
Typical 4 min
Tower
The Eaton 5110 UPS uses Automatic Voltage Regulation (AVR) to smooth
out wide fluctuations in input voltage. The Eaton 5110 UPS accepts this
inconsistent voltage and delivers clean, consistent output for protected
equipment. AVR enables you to work through even the most frequent
brownouts and power sags.
Unlike typical line-interactive systems, the 5110 UPS does not switch
back and forth to battery power to accomplish this voltage regulation
- which would shorten battery life and increase battery replacement
costs. As a result, battery power is conserved for when you really
need it.
Typical applications:
Home Office
Workstations
Rack equipment
Point of Sale equipment
Small network servers
16
EATON CORPORATION UPS and Power Quality Products Catalogue
Superior series 5 power protection for office servers
Eaton 5110 Technical Specifications
Rating
500VA
700VA
1000VA
1500VA
Part Number
51100500A
51100700A
51101000A
51101500A
Capacity
500VA/300W
700VA/420W
1000VA/600W
1500VA/900W
Dimensions (mm) HxWxD
270x87x260
270x87x260
270x87x384
270x87x384
Unit Weight (kg)
12
12.5
Input Connection
IEC C14-10A
Output Connection
(6) AUST 10A Outlets (3 Battery Backup & Surge Protection, 3 Surge Protection only)
Operation
Input Voltage Range (on-line operation)
186 to 280VAC
Output Voltage Regulation (on-line)
216 to 260VAC
On Battery Output Voltage
Nominal -12% to +10%
Frequency
50 Hz
Lightning/Surge Protection
476 joules
Safety
AS/NZS62040.1.1, AS/NZS60950, A-Tick
EMI
AS/NZS62040.2, AS/NZSCISPR22, C-Tick
Transfer Time to Battery/AC
2-6 msec. typical
Battery Type
Sealed, maintenance free lead-acid battery
Typical Backup Time
3 minutes at full rated load
Internet/Phone/Fax Protection
RJ11
Short Circuit Protection
Circuit Breaker
Communication Port
USB
Environmental
Operation Temperature
0oC - 40oC
Operation Relative Humidity
0 to 95% non condensing
Storage Temperature
-15oC - 50oC
Software
Intelligent Power Protector Software is included free of charge
Battery Run Times (in minutes)
Load (VA)
Model
80
170
250
330
420
550
650
51100500A
43
17
11
51100700A
53
30
14
51101000A
80
64
51101500A
74
850
1000
28
20
15
35
12
14
10
1200
1350
1500
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
17
Superior series 5 performance
Eaton 5115
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 5 (Line Interactive)
500-1400VA
240 Vac
Typical 5 min
Cabinet
The Eaton 5115 is designed to protect workstations, small servers, hubs,
routers, PCs, and other electronic equipment from power disturbances.
Ideally suited for small to medium-sized businesses, the 5115 UPS
features both USB and serial ports to facilitate software communication.
To prolong battery service life, the 5115 incorporates ABM Technology,
which increases battery service life, optimises recharge time for quick
recovery after power outages, and provides advanced warning of the
end of useful battery life. In addition, incoming voltage fluctuations
are corrected so they do not affect the performance of connected
equipment.
Unlike other competitive UPSs in its class, which use a simulated sine
wave, the Eaton 5115 provides pure sine wave output during battery
operation. As a result, the connected load continues to receive a quality
electrical waveform and operates smoothly even during power outages.
To preserve data integrity, the 5115 is bundled with Intelligent Power
Product highlights:
Extends battery service life and provides advanced warning of the end
of useful battery life with ABM Technology
Delivers smooth, continuous power with pure sine wave output
Regulates power fluctuations with Buck and Boost voltage regulation
Australian output sockets eliminate messy adaptors
Protects equipment connected by network or phone wiring from "back
door" power surges with a Network Transient Protector
Minimises downtime with hot-swappable batteries
Communicates with Intelligent Power Protector software via serial
and USB ports
Provides investment protection with a two-year limited warranty,
8-year pro-rated warranty, $50,000 load protection guarantee
Options:
Extended warranty plans
Protector, which contains exclusive power management software
featuring extensive power monitoring and control capabilities. Backed
by superior performance, the 5115 UPS keeps your equipment up and
running without interruption.
Typical applications:
Small office servers
High-capacity PCs and workstations
18
EATON CORPORATION UPS and Power Quality Products Catalogue
Superior series 5 performance
Eaton 5115 Technical Specifications
Rating
500VA
750VA
1000VA
1400VA
Part number
51150500A
51150750A
51151000A
51151400A
Capacity (VA/Watts)
500/320
750/500
1000/670
1400/950
Dimensions WxDxH (mm)
150x268x185
150x333x185
150x333x185
150x388x185
Weight (kg)
12
13
17
Input connection
IEC C14-10A
IEC C14-10A
IEC C14-10A
IEC C14-10A
Output connection
(3) AUST 10A
(3) AUST 10A
(3) AUST 10A
(3) AUST 10A
Typical runtime (Full load)
5 min
6 min
5 min
5 min
Operational
Nominal input voltage (Vac)
240 Vac
Input voltage range
192 - 288VAC (+/-20%)
Operating
frequency 50/60 Hz auto sensing
Input power factor
Same as load
Output voltage
240 Vac
Output voltage regulation
216-254VAC (-10%/+6%) or +/-5% on battery
Overload capacity
110% 3 min; 150% 10 cycles
Efficiency
95%
User interface
LED
Four LEDs; UPS on, UPS on battery, overload, alarm
Standard communication ports
1 x RS232 & 1 x USBPort
Environmental
Operating temperature
0C to +40C
Storage temperature
-15C to +55C
Altitude
< 3000 m
Audible noise at 1 metre
< 40dBA
Certification
Markings
CE/GS/C-Tick
Safety
EN 50091-1-1 & IEC 609050
EMC (Class B)
AS62040.2.2001, C-Tick
Battery Runtimes (in minutes)
Load
51150500A
51150750A
51151000A
51151400A
200VA/128W
17
38
41
58
300VA/192W
11
27
28
41
500VA/320W
14
15
28
600VA/402W
10
19
750VA/503W
14
900VA/603W
10
1000VA/670W
1200VA/804W
1440VA/938W
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
19
Premier high density series 5 protection for network devices
Eaton Evolution
Technology:
Series 5 (Line Interactive)
Total flexibility
Rating: 650-1550VA
Evolution has unmatched flexibility
Voltage:
230 Vac
Format: Evolution is available in tower or 1U rack format
Backup time:
5-10 minutes
Configuration:
Rack and Tower mount
Communication: the Evolution includes both serial and USB ports,
plus remote On/Off connector and an extra Mini Slot for optional
communication cards. The UPS comes with a complete Eaton
software suite
Line interactive
High density protection for network devices
Maximum availability
Advanced protection for:
Rack servers
Tower servers
Network devices
Storage systems
Powershare: the Eaton Evolution output sockets are individually
controlled to provide load-shedding to maximise the backup time and
provide remote reboot and sequential start-up as standard
Continuous power supply: Hot swappable batteries.
The optional HotSwap MBP (Maintenance By-Pass) module allows the
UPS to be replaced without interrupting the power supply
Pure sinewave output: when operating in battery mode the Eaton
Evolution still provides high quality output signal for sensitive
connected equipment
Minimum total cost of ownership
Line-interactive HF technology: the best price/performance ratio
No additional cost: rack 1U models are provided with the rail kits
Remote supervision: a wide range of options using the Eaton Software
suite, including point-to-point power management, SNMP, relay
outputs, etc
Tower model
20
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier high density series 5 protection for network devices
1 x USB port + 1 x serial port
+ remote ON/OFF
Full user interface:
- ON/OFF button for UPS and outlets
- Load protected/ not protected LED
- Utilised power level/Battery charge level
- Status of switchable outlets
4 x IEC 10A sockets,
including 2 programmable sockets
Mini Slot for communications cards
Panel for batteries replacement
(Hot swappable)
Eaton Evolution 1550 Tower
Eaton Evolution Technical Specifications
Rating (VA/W)
Format
650VA / 420W
Tower or 1U Rack
850VA / 600W
Tower or 1U Rack
1150VA / 770W
Tower or 1U Rack
1550VA / 1100W
Tower or 1U Rack
Electrical characteristics
Technology
Input voltage and frequency
ranges without using batteries
Output voltage and frequency
Line-Interactive High Frequency (Booster + Fader)
160V-294V (adjustable to 150V-294V) 47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system),
up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software).
230 V (+6/-10 %) (Adjustable to 200 V (10 % derating of output power) / 208 V / 220 V / 230 V / 240 V), 50/60 Hz +/- 0.1 %
Connections
Input
Outputs
Remotely controlled sockets
Additional outputs with HS MBP
Additional outputs with FlexPDU
Batteries
Typical backup times for 50 and
70% load
Battery management
Interfaces
Communication ports
Communications card slots
1 x IEC C14 (10A) socket
4 x IEC C13 (10A)
4 x IEC C13 (10A)
4 x IEC C13 (10A)
2 groups of 1 x IEC C13 (10A)
2 groups of 1 x IEC C13 (10A)
2 groups of 1 x IEC C13 (10A)
4 x 3 Pin Aust or 6x IEC 10A sockets or terminal blocks (HW version)
4 x 3 Pin Aust or 12 x IEC 10 A sockets
9/6 min
16/7 min
14/7 min
4 x IEC C13 (10A)
2 groups of 1 x IEC C13 (10A)
14/7 min
Automatic weekly test (period adjustable), automatic recognition of external battery units => continuous maximisation
of backup time + deep discharge protection
1 x USB port + 1 x RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously)
+ 1 mini terminal block for remote ON/OFF and Remote Power Off
1 Mini Slot for Netword Card-MS, Relay Card-MS or Network & Modbus Card-MS
Operating conditions, standards and approvals
Operating temperature
Noise level
Performance - Safety - EMC
Approvals
0 to 35C
0 to 35C
0 to 35C
0 to 40C
< 40dbA
< 40dbA
< 40dbA
< 40dbA
IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 EN 50091-2 class B (EMC), IEC/EN 62040-3 (Performance),
IEC/EN 61000-4-2, 61000-4-3, 61000-4-4; 61000-4-5, 61000-4-6, 61000-4-8 (EMI)
CE, CB report, TV
Dimensions W x D x H / Weight
Dimensions of the Tower
Dimensions of the Rack
Weight of the Tower/Rack
147 x 418 x 234 mm
438 x 366 x 43.2 (1U)
8.4/10.1 kg
147 x 418 x 234 mm
438 x 512 x 43.2 (1U)
10.85/16.1 kg
147 x 418 x 234 mm
438 x 512 x 43.2 (1U)
12.5/16.6 kg
147 x 492 x 234 mm
438 x 556 x 43.2 (1U)
16.53/20 kg
Customer Service & Support
2 years warranty
Warranty+
Standard product exchange, including the battery
Optional 3-years warranty
Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Part Numbers
650
850
1150
1550
Tower
Rack1U
M68450
M68451
M68452
M68453
M68454
M68455
M68457
M68458
www.eaton.com/powerquality 1300 UPS UPS
21
Superior series 5 protection for low density IT tower and rack applications
Eaton 5130
Technology:
Series 5 (Line Interactive)
Options:
Rating:
1250-3000 VA
Extended Battery Modules for longer run times
Voltage:
230 Vac
Mini Slot connectivity cards
Configuration:
Rack-mount/Tower convertible
Extended warranty plans
The 5130 resolves outages, sags, surges, under-voltage and over-voltage
conditions - and supplies regulated power to all connected equipment.
This UPS is particularly well suited for protecting:
IT and networking equipment, such as routers, switches, servers,
wireless devices, storage systems, security systems and PC/
workstation clusters
Telecom equipment, such as PBXs, VoIP components and EDGE/3G/
WiMAX wireless networking equipment
The 5130 is value-priced, but it delivers features you would normally
expect to find in much higher priced systems, such as: load segment
control, hot-swappable battery modules, long battery runtime options,
multiple communication options, high output power factor and high
power densityall in a sleek, modern package.
Features:
Protects connected equipment from five of the most common power
anomalies: failures, surges, sags, under-voltage and over-voltage
Provides more real wattage in less space with a 0.9 power factorto
protect more equipment and leave more room to expand IT systems
Offers the choice of rack-mount or tower installation with spacesaving 2U or 3U reduced-depth packages, including internal batteries
Enables prioritised shutdown of non-essential equipment during
outages to maximise battery runtime for critical deviceswith
PowerShare
Maximises availability with extended battery runtime options, hotswappable batteries, optional maintenance bypass, remote monitoring
and power management software
22
EATON CORPORATION UPS and Power Quality Products Catalogue
Superior series 5 protection for low density IT tower and rack applications
Eaton 5130 Technical Specifications
Rating
1250VA
1750VA
2500VA
3000VA
3000VA
Part number
PW5130i1250-XL2U
PW5130i1750-XL2U
PW5130i2500XL2UAU
PW5130i3000XL2UAU
PW5130i3000XL3UAU
Capacity (VA/Watts)
1250/1150
1750/1600
2500/2250
3000/2700
3000/2700
Dimensions WxDxH(mm)
441x509x87 (2U)
441x509x87 (2U)
441x634x87 (2U)
441x634x87 (2U)
441x484x87 (3U)
Weight (kg)
24.3
26.6
33.8
33.8
34.3
Input connection
IEC C14-10A
IEC C14-10A
IEC C20-16A
IEC C20-16A
IEC C20-16A
Output connection
(8) IEC C13-10A
(8) IEC C13-10A
(1) IEC C19-16A
(8) IEC C13-10A
(1) IEC C19-16A
(8) IEC C13-10A
(1) IEC C19-16A
(8) IEC C13-10A
Operational
Nominal input voltage (Vac)
230 Vac (200/208/220/240 Selectable)
Input voltage range
160-294 Vac
Operating frequency
50/60 Hz auto sensing, tolerance 47-70Hz
Nominal output voltage
230 Vac (200/208/220/240 Selectable)
Output voltage range
230V +6%, -10%
User interface
LED
13 LED's: bar graph % load, battery charge level and various status and alarms
Standard communication ports
RS232 and USB as standard on all models
Optional
1 Mini Slot for Network Card-MS and Relay Card-MS connectivity cards
Environmental
Operating temperature
1250VA: 0C +40C , 1750-3000VA: 0C +35C
Storage temperature
-15C +50C
Altitude
< 3000 m
Audible noise at 1 metre
< 45 dBA
Certification
Markings
C-Tick, CE, TUV
Safety
EN50091-1-1 and IEC60950
EMC
EN 50091-2
Battery Runtimes (in minutes)
Rack/Tower Models
Internal Batteries
+1 EBM
+2 EBMs
+3 EBMs
+4 EBMs
PW5130i1250-XL2U
15/5
58/29
100/54
143/99
185/104
PW5130i1750-XL2U
9/3
36/16
62/28
89/41
115/53
Half Load/ Full Load
PW5130i2500-XL2U
11/3
55/23
100/42
150/63
206/85
PW5130i3000-XL2U
10/3
44/17
73/32
101/47
130/62
PW5130i3000-XL3U
10/3
44/17
73/32
101/47
130/6
Battery Backup Times in minutes Half Load/ Full Load.
Run time chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
23
Premier efficient & manageable protection for high-end IT applications
Eaton 5PX
Availability and Flexibility
The 5PX comes in a rack/tower convertible cabinet - pedestal and rail
kits are included with all models at no extra charge
Stronger, longer battery life: Eaton ABM battery management
technology uses an innovative three-stage charging technique that
only recharges the battery when necessary, so the battery experiences
less corrosion and service life is prolonged by up to 50%
Batteries can be hot-swapped without ever having to shut down
connected equipment. With an optional, hot-swap maintenance bypass
module, you can even replace the entire UPS
There is also the possibility to add more runtime with up to four
external hot-swappable battery modules, able to run systems for
hours if necessary. The additional battery modules are automatically
recognised by the UPS
Ideal for protecting
Servers
Switches
Routers
Technology:
Series 5 (Line Interactive)
Rating: 1500-3000VA
Voltage:
230 Vac
Configuration:
Rack-mount/Tower convertible
Storage devices
The Eaton 5PX provides exceptional efficiency, manageability and
metering capabilities for IT managers
Manageability
The new graphical LCD display provides clear information on the UPSs
status and measurements on a single screen (in seven languages).
Enhanced configuration capabilities are also available with easy-to-use
navigation keys
For the first time in the industry the 5PX can meter energy consumption
right down to the managed outlet groups. kWh values can be monitored
using the LCD or Eatons Intelligent Power Software Suite
Load segment control enables prioritised shutdowns of nonessential
equipment to maximise battery runtime for critical devices. Load
segment control can also be used to remotely reboot locked-up
network equipment or to manage scheduled shutdowns and sequential
start-ups
The 5PX offers Serial and USB connectivity, plus an extra Mini Slot for
an optional communication card (including SNMP/Web card or relay
contact card). Eatons Intelligent Power Software Suite compatible
with all major OS including virtualisation software such as VMware and
Hyper-V is included with each UPS
Rack/Tower versatile
Performance and Efficiency
With an optimised electrical design, the 5PX can provide up to 99%
efficiency, reducing cooling and utility costs
With a power factor of 0.9, the 5PX delivers more real output power.
It powers more servers than other UPSs with equivalent VA ratings
and lower power factors. The 5PX is compatible with all modern IT
equipment
When operating in battery mode the 5PX provides a high quality output
waveform for any sensitive equipment connected, such as active PFC
(power factor corrected) servers
24
EATON CORPORATION UPS and Power Quality Products Catalogue
Intuitive LCD display for ease
of configuration and management
Premier efficient & manageable protection for high-end IT applications
Eaton 5PX 3000i RT2U
Graphical LCD display :
- Clear information on UPS status and measurements
- Enhanced configuration capabilities
- Available in 7 languages
Panel for batteries replacement (Hot swappable)
1 USB port + 1 serial port + remote ON/OFF and remote
power OFF inputs
External battery (EBM) connector
8 IEC 10A + 1 IEC 16A sockets with energy metering
(including 4 programmable sockets)
Mini Slot for connectivity cards
Eaton 5PX Technical Specifications 1500
2000
2200
3000
Rating (VA/W)
1500VA / 1350W
2000VA / 1800W
2200VA / 1980W
3000VA / 2700W
Format
RT2U (rack / tower 2U)
RT2U (rack / tower 2U)
RT2U (rack / tower 2U)
RT2U & RT3U
Electrical characteristics
Technology
Line-Interactive High Frequency (Pure Sinewave, Booster + Fader)
Input voltage and frequency ranges
160V-294V (adjustable to 150V-294V) 47 to 70 Hz (50 Hz system),
without using batteries
56.5 to 70 Hz (60 Hz system), 40 Hz in low-sensitivity mode
Output voltage and frequency
230 V (+6/-10 %) (Adjustable to 200V / 208V / 220V / 230V / 240V), 50/60 Hz +/- 0.1 % (autosensing)
Connections
Input
1 IEC C14 (10 A) socket
1 IEC C14 (10 A) socket
1 IEC C20 (16 A) socket
1 IEC C20 (16 A) socket
Outputs
8 IEC C13 (10 A)
8 IEC C13 (10 A) sockets
8 IEC C13 (10 A) sockets,
1 IEC C19 (16 A) socket
8 IEC C13 (10 A) sockets,
1 IEC C19 (16 A) socket
Remotely controlled sockets
2 groups of 2 x IEC C13 (10 A)
Additional outputs with Hot Swap MBP
4 AUS 10A + 1 IEC 16A sockets or 6 IEC 10 A sockets or terminal blocks (HW version)
Additional outputs with FlexPDU
6 AUS 10A + 1 IEC 16A sockets or 12 IEC 10 A sockets
Batteries Typical backup times for 50 and 70% load*
5PX
19/11 mins
16/9 mins
15/8 mins
14/9 mins
5PX + 1 EBM
90/54 mins
66/39 mins
60/35 mins
66/38 mins
5PX + 4 EBM
285/180 mins
231/138 mins
210/125 mins
213/121 mins
Battery management
ABM & Temperature compensated charging method (user selectable), Automatic battery test, deep discharge
protection, automatic recognition of external battery units
Interfaces
Communication ports
1 USB port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously)
+ 1 mini terminal block for remote ON/OFF and Remote Power Off
Communications card slots
1 Mini Slot for Network Card-MS, Relay Card-MS and Network & Modbus Card-MS connectivity cards
Operating conditions, standards and approvals
Operating temperature
0 to 40C
Noise Level
< 45 dBA
Performance - Safety - EMC
IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 (EMC), IEC/EN 62040-3 (Performance), C-Tick
< 45 dBA
< 45 dBA
Approvals
CE, CB report, TV
< 50 dBA
Dimensions W x D x H / Weight
UPS Dimensions (mm)
441 x 522 x 86.2 (2U) mm
441 x 522 x 86.2 (2U) mm
441 x 522 x 86.2 (2U) mm
441 x 647 x 86.2 (RT2U) mm
UPS Weight (kg)
27.6 kg
28.5 kg
28.5 kg
38.08 (RT2U), 37.33 (RT3U)
Dimensions of EBM
same as UPS
Weight of the EBM
32.8 kg
32.8 kg
32.8 kg
46.4kg (RT2U), 44.4kg
(RT3U)
441 x 497 x 130.7 (RT3U) mm
Customer Service & Support
Warranty
3 years on electronics, 2 years on batteries
* Runtimes are shown at 0.7 power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Part Numbers
1500
2000
2200
3000 (RT3U)
3000 (RT2U)
UPS
5PX1500iRT
5PX2000iRT
5PX2200iRTAU
5PX3000iRT3UAU
5PX3000iRT2UAU
EBM
5PXEBM48RT
5PXEBM48RT
5PXEBM48RT
5PXEBM72RT3U
5PXEBM72RT2U
www.eaton.com/powerquality 1300 UPS UPS
25
Essential series 9 Power Protection
Eaton E Series DX
Features
Double conversion topology assures maximum reliability
Wide input voltage range appropriate for the harshest
electrical environments
Tested for generator compatibility
Standard Models for fixed-run time performance
XL Models for customised, long run-time applications,
with fast recharging
Automatic bypass for fault-tolerance
Built in maintenance bypass on 6-20kVA models
Optional SNMP communications provides remote network
based monitoring
Cold start on battery power allows portable power
WINPOWER software monitors power conditions
Intuitive front-panel LED user interface for consistent
status indication
Technology: Series 9 (Double Conversion On Line)
Rating: 1kVA 20kVA
Voltage: 230/240V
Backup Time: Typical 5 min
Configuration: Tower
The E Series DX UPS double-conversion UPS affordably protects
mission critical applications from downtime, data loss and corruption.
The double-conversion architecture incorporates rectifier and inverter
stages to completely isolate the output power from all input anomalies.
By adapting to a wide range of input voltages, the E Series DX avoids
battery usage during minor power fluctuations, saving its capacity for
times when utility power is completely lost.
6-20kVA models are parallelable for increased capacity
and/or redundancy
Options
SNMP/Web Card
Relay Card
External Maintenance Bypass Switch
Extended Battery Cabinets
Ideal for protecting
Computers and Peripherals
POS Equipment
PLC Systems
Security Systems
3kVA rear panel
26
EATON CORPORATION UPS and Power Quality Products Catalogue
Essential series 9 Power Protection
Eaton E Series DX Technical specifications
Capacity (VA/Watts)
1000VA/700W
2000VA/1400W
3000VA/2100W
6kVA/4.2kW
10kVA/7kW
10kVA/7kW
15kVA/10.5kW
20kVA/14kW
N/A
N/A
EDX15KHXL31
EDX20KHXL31
Standard Model
(Internal Battery)
EDX1000HA
EDX2000HA
EDX3000HA
EDX6000HA
EDX10000HA
N/A
XL Model (Large Charger
+ External Battery)
EDX1000HXL
EDX2000HXL
EDX3000HXL
EDX6000HXL
EDX10KHXL
EDX10KHXL31
Input / Output
Nominal Input Voltage
220/230/240Vac 1 Phase (240V preset on "A" models, 230V on others)
380/400/415Vac 3 phase
Input Voltage Window
@ full load
1605V 2965V at >80% load
176 - 276Vac (at full load)
Input Power Factor
>0.95
0.98
Frequency & Frequency
Range
50/60Hz; Tolerance (46/56 0.5) Hz Low, (54/640.5) Hz High
Nominal Output Voltage
220/230/240V (240V preset on "A" models, 230V on others)
Output Voltage on
Battery
220/230/240V (240V preset on "A" models, 230V on others)
Overload performance
108% 5% to 150% 5% for 30 secs
Input Connection
C14 10A
C14 10A
C20 16A
Hard Wired
Output receptacles
(4) IEC C13 10A
(6) IEC C13 10A
(4) IEC C13 10A
& Hard Wired
Hard Wired
Battery Quantity/Type
(Standard)
3 x 12V (7.2Ah)
8 x 12V (7.2Ah)
8 x 12V (7.2Ah)
20 x 12V
(7.2Ah)
Battery Quantity (XL)
3 x 12V
8 x 12V
8 x 12V
20 x 12V
Re-charge time to 90%
capacity
8 hours
Start-On-Battery
UPS can be started without being connected to AC utility power
0.95
105-130% for 10 mins, 130% for 1 sec, up to 130% continuous on bypass
Battery
20 x 12V (9Ah)
N/A
<7 hours
XL Models dependant on battery capacity
User Interface
Visual
LED mimic diagram with 4 x LEDs for Utility, Bypass, Inverter & Battery Status, 5 LED Bar Graph for Load and Battery Capacity, Fault LED
Control
Two buttons for On/Off and Test/Alarm Silence
Communications / management
Power Management
Software
WinPower power management software, included on CD
Connection Type
Standard RS232 (DB9)
Connectivity slot
Intelligent Slot for optional SNMP card / AS 400 Relay Card / Modbus Card
Environment
Operating Temperature
0C ~ 40C
Humidity
5-95% Non Condensing
Noise Level @ 1m
<50dBA
Standards
IEC61000-4-2 Level 4, IEC61000-4-3 Level 3, IEC61000-4-4 Level 4, IEC61000-4-4 Level 4, IEC62040-1, EN55022 Class B, CE Mark
<50dBA
<50dBA
<55dBA
Dimensions & Weights W x H x D mm
-
(Standard Models)
145 x 220 x 400
192 x 340 x 460
192 x 340 x 460
260 x 717 x 570
260 x 717 x 570
(XL Models)
145 x 220 x 400
192 x 340 x 460
192 x 340 x 460
260 x 717 x 570
260 x 717 x 570
260 x 717 x 570
260 x 717 x 570
260 x 717 x 570
Weight (Standard/
XL) kg
14 / 7
34.5 / 15
35.5 / 16
90 / 35
93 / 38
39
55
55
E Series DX internal battery models runtime chart
EDX1000HA
EDX2000HA
EDX3000HA
EDX6000HA
EDX10000HA
Battery Runtime 1/2 load
14 min
31 min
16 min
20 min
16 min
Battery Runtime Full load
7 min
11 min
>5 min
8 min
>5 min
Battery backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
27
Superior series 9 protection for critical applications
Eaton EX
Eaton EX Rack/Tower versatility
Technology:
Series 9, (Double Conversion On Line)
Rating:
1000 - 3000VA
Voltage:
208240Vac
Configuration:
Rack-mount/Tower convertible
Maximum availability
Topology: double conversion on-line UPS with automatic
by-pass and power factor correction
Powershare: the Eaton EX output sockets are individually controlled
to provide load-shedding to maximise the backup time and provide
remote reboot and sequential start-up as standard
Continuous power supply: Hot swappable batteries.
The HotSwap MBP (Maintenance By-Pass) module allows the UPS to
be replaced without interrupting the power supply
Long backup times: 1 to 4 EXB battery units can be added to the
Eaton EX. The Eaton EX 3000XL has a built-in super charger for extra
long backup times
Minimum total cost of ownership
Easy operation: the LCD gives you access to a wide range of
measurements and set-up menus
Remote supervision: the Eaton Intelligent Power software suite
offers a wide range of communication option including: SNMP and
HTML, ModBus/JBus and relay outputs
28
EATON CORPORATION UPS and Power Quality Products Catalogue
Total flexibility
Eaton EX has unmatched Flexibility.
Format: EX 1000 to 1500 are available in RT2U convertible rack/
tower format (compatible with short-depth rack). EX 2200 & 3000 are
available in RT2U format (optimised for rack mounting) or RT3U (for
tower or short-depth racks)
Connections: with FlexPDU and HotSwap MBP, the RT2U and RT3U
models can be connected by sockets or terminal blocks. They can be
installed as required, on the side or on top of the unit
Compatible with high power factor loads: Eaton EX is rated for 0.9
power factor (1000 VA/900 W, 1500 VA/1350 W, 2200 VA/1980 W and
3000 VA/2700 W)
Communication: the EX includes both serial and USB ports,
plus remote On/Off connector and an extra slot for optional
communication cards
Ideal protection for:
Servers, data storage and network equipment
Telephony - VoIP
Medical equipment - Industrial processes
Superior series 9 protection for critical applications
1 x USB port + 1 x serial port +
remote ON/OFF and emergency stop
inputs.
LCD Multilingual display
- 6 languages,
- displays measurements,
- displays alarms,
- access to control and set-up
menus.
EXB battery unit connector.
EXB units recognised automatically.
8 x IEC 10A sockets, including 4 x
Powershare programmable sockets
and 1 x IEC 16A socket.
Panel for batteries replacement
(Hot swappable)
Mini Slot connectivity card slot.
Mountings for HotSwap MBP and
FlexPDU.
Eaton EX RT
Eaton EX Technical Specifications
1000 RT2U
1500 RT2U
2200
3000 - 3000 XL
Rating (VA/W)
1000 VA / 900 W(1)
1500 VA / 1350 W(1)
2200 VA / 1980 W
3000 VA / 2700 W(1)
Format
RT2U (tower/rack 2U)
RT2U (tower / rack 2U) and RT3U (tower / rack 3U)
Electrical characteristics
On-line double conversion with automatic by-pass and power factor correction
Architecture
Input voltage and frequency ranges without using
100/120/140/160 V(2) to 284V - 40 to 70 Hz
batteries
Output voltage and frequency
100/120/160/184 V(2) to 284V - 40 to 70 Hz
230 V (adjustable to 200/208/220/240/250 V), 50/60 Hz autoselect or frequency converter mode (3)
230 V (adjustable to 200/208/220/240 V),
50/60 Hz auto-select or frequency converter mode
Input
1 x IEC C14 (10A) socket
1 x IEC C20 (16A) or terminal block on HotSwap
MBP HW (Hard-Wired)
Outputs
6 x IEC C13 (10A) sockets
8 x IEC C13 (10A) sockets + 1 x IEC C19 (16A) socket
Remotely controlled Powershare sockets
2 independent groups: 2 + 1 x IEC C13 (10A) sockets
2 groups of 2 x IEC C13 (10A) on Eaton EX
Additional outputs with HotSwap MBP
4 x Aust 3 pin or 6 x IEC 10A sockets or terminal blocks (HW version)
Additional outputs with FlexPDU
6 x Aust 3 pin or 12 x IEC 10A sockets
Connections
Battery
Typical backup times for 50 and 70% load(6) except for Eaton EX 3000 XL(5)
EX
18 min / 12 min
13 min / 9 min
17 min / 12 min
15 min / 10 min
EX + 1 EXB
75 min / 50 min
50 min / 35 min
85 min / 60 min
60 min / 40 min
EX + 4 EXB
250 min / 200 min
180 min / 120 min
285 min / 200 min
190 min / 150 min
Battery management
Automatic weekly test (period adjustable using LCD display or in software supplied), automatic recognition of external
battery units => continuous maximisation of backup time + deep discharge protection
Interfaces
Indicators and display
3 x LEDS + adjustable multilingual display: display of measurements, access to control and set-up menus
Communication ports
1 x USB port + 1 x RS232 serial port and relay contacts (4) + 1 x mini terminal block for remote ON/OFF and emergency stop
Communications card slots
1 x Mini Slot for Network Card-MS, Relay Card-MS or Network & Modbus Card-MS connectivity cards
Operating conditions, standards and approvals
Operating temperature noise level
0C to 40C continuous, 45 dBA
Performance - Safety - EMC
IEC/EN 62 040-3 (VFI-SS-113), IEC/EN 62 040-1-1, IEC/EN 60 950-1 (RD), IEC/EN 62 040-2 C1 Class
Approvals
CE, TV GS, CB report, cTV-US
CE, TV, CB Report, UL
242 x 153 x 490 mm / 18 kg
440 x 131 x 490 mm (7) / 30 kg (3000 XL = 18 kg)
86.5 x 438 x 483 mm / 20.5 kg
CE, TV, CB Report, UL
Dimensions (H x W x D) / Weight
EX
EX RT2U
EX EXB
242 x 153 x 440 mm / 21 kg
86 x 440 x 640 mm / 31 kg
440 x 131 x 490 mm(7)
EX EXB RT2U
86.5 x 438 x 483 mm / 24.5 kg
Customer Service & Support
2 years warranty
Standard product exchange, including the battery
Warranty+
Optional 3-years warranty (depending on the country please visit www.eaton.com/powerquality)
1: Maximum rating with EXB battery units: Eaton EX 1000 = 800 W, Eaton EX 1500 =1200 W and Eaton EX 3000=2400W. 2: Lower limits for <20%, <33%, <66%, >=66% of nominal power (VA). For active
output power greater than 0.7 and 0.8 nominal rating, the lower limit is 180V and 190V respectively. 3: Derated by 15% when used as a frequency converter. 4: USB and RS232 serial ports cannot be used
simultaneously. 5: Except Eaton EX 3000 XL: UPS with high speed charger, without built-in batteries, for custom configurations: ask us for details. 6: Runtimes are shown at 0.7 power factor. Backup times are
approximate and may vary with equipment, configuration, battery age, temperature, etc. 7: compatible with 600 mm deep rack.
Part Numbers
1000
1500
2200
3000
EX
M68181
M68183
M68400
M68402 - XL: M68404
EX RT2U (includes rack kit)
M68182
M68184
M68401
M68403
EX EXB
M68186
M68186
M68405
M68405
EX Rack Kit 2U/3U
M68441
M68441
www.eaton.com/powerquality 1300 UPS UPS
29
Premier series 9 Tower UPS for all critical applications
Eaton 9130 Tower
Product highlights:
Offers premium performance with a 0.9 power factor and
95% efficiency
Increases battery service life and system uptime with ABM battery
charging technology
Enables prolonged runtime of essential equipment during power
outages by allowing for orderly, remote shutdown of non-critical
systems or processes
Ensures data and system integrity with Intelligent Power
management software
Options:
Extended Battery Modules for extended run time and Extended
Battery Cabinets for even longer run time
External Battery Charger Unit for fast charging of long run time
Extended Battery Cabinets
Hard wiring kits for fixed installations
Interlocked Maintenance Bypass Switches
Mini Slot connectivity cards
Extended warranty plans
Technology:
Rating:
Voltage:
Configuration:
Series 9, (Double Conversion On Line)
700 - 6000VA
208240Vac
Tower
The Eaton 9130 UPS, resolves utility power problems and delivers
superior power protection for IT and networking equipment, medical
systems, manufacturing process control or anywhere critical
equipment and applications require clean, continuous power.
Double-conversion design for superior power protection The 9130
is constantly monitoring power conditionsregulating both voltage
and frequency. Even when presented with the most severe power
problems, this UPSs output remains within two percent of nominal
voltage. With a wide input voltage range, the 9130 does not depend
on batteries to smooth out minor power fluctuations. Batteries are
conserved for those times when utility power is highly unstable or
completely out. If an outage occurs, the 9130 transfers to battery with
zero interruption in power, making this an ideal UPS for sensitive and
critical equipment.
More real power for less cost. High 0.9 output power factor enables
the 9130 to provide its full power capability to modern IT equipment
that may have a wide range of leading and lagging power factors. With
a 0.99 input power factor, this UPS avoids the disturbances that some
energy converters tend to cause.
Typical applications:
Servers, networking gear
Telecommunications, VoIP, security systems
Medical systems
Diagnostics and medical screening
Patient record archives
Manufacturing systems
Chip fabrication
Pharmaceutical production
Chemical processing
30
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier series 9 Tower UPS for all critical applications
Eaton 9130 Tower Technical Specifications
Rating
700VA
1000VA
1500VA
2000VA
3000VA
6000VA
Part number
PW9130G700T-XLAU
PW9130G1000T-XLAU
PW9130G1500T-XLAU
PW9130G2000T-XLAU
PW9130G3000T-XLAU
PW9130G6000T-XLAU
Capacity (VA/Watts)
700/630
1000/900
1500/1350
2000/1800
3000/2700
6000/5400
Dimensions WxDxH (mm)
160x355x250
160x383x250
160x435x250
214x410x345
214x410x345
242x542x575
Weight (kg)
12.2
14.5
19.0
34.5
34.5
75.5
Input connection
IEC C14-10A
IEC C14-10A
IEC C14-10A
IEC C14-10A
IEC C20-16A
Hard Wired
Output connection
(4) AUST 10A
(4) AUST 10A
(4) AUST 10A
(5) AUST 10A
(1) IEC C13-10A
(5) AUST 15A
(1) IEC C19-16A
Hard Wired
Operational
Nominal input voltage
(Vac)
240Vac (200/208/220/230 selectable)
Input voltage range
700-1500VA: 120/140/160-276 Vac (at 33%/66%/100% 0.7pf load)
2000-3000VA: 140/160/180-276 Vac (at 33%/66%/100% 0.7pf load)
6000VA: 120/140/160/180-276V (25%/50%/75%//100% 0.9pf Load)
Operating frequency
50/60 Hz auto sensing, tolerance 40-70Hz
Input power factor
0.99
Nominal output voltage
240Vac (200/208/220/230 selectable)
Output voltage regulation
+/-2%
Overload capacity
700-3000VA: Up to 130 % for 12 seconds, 130-150% for 2 sec
6000VA: Up to 130 % for 120 seconds, 130-150% for 30 sec
Efficiency
700-2000VA: 90% online, 93% High Efficiency Mode
3000VA: 91% online, 93% High Efficiency Mode
6000VA: 95% online, 98% High Efficiency Mode
User interface
LCD display
LCD display showing both UPS meters and UPS settings
LED
Four LEDs; UPS On, UPS on Battery, UPS on bypass, Alarm
Standard communication
ports
RS232 and USB as standard on all models
Optional
1 Mini Slot for Network Card-MS, Relay Card-MS or Network & Modbus Card-MS connectivity cards
Environmental
Operating temperature
0C +40C
Storage temperature
-15C +40C
Altitude
< 3000 m
Audible noise at 1 metre
700-3000VA: < 52 dBA, 6000VA: < 55 dBA
Certification
Markings
C-Tick, CE, GS
EMC
EN62040-2 Emissions, category C1; Immunity, category C2
Battery Runtimes (in minutes) Standard Extended Battery Modules
Load (VA/Watts)
% 0f Load
Internal Batteries
w/1 EBM
w/2 EBM
w/3 EBM
w/4 EBM
PW9130G700T
700/630
100%
N/A
N/A
N/A
N/A
350/315
50%
14
N/A
N/A
N/A
N/A
PW9130G1000T-XLAU
1000/900
100%
31
51
82
100
500/450
50%
19
68
111
192
246
PW9130G1500T-XLAU
1500/1350
100%
24
46
69
90
750/675
50%
14
61
112
172
221
PW9130G2000T-XLAU
2000/1800
100%
11
44
79
115
162
1000/900
50%
28
96
168
258
336
PW9130G3000T-XLAU
3000/2700
100%
21
51
66
93
1500/1350
50%
15
60
100
169
215
PW9130G6000T-XLAU
6000/5400
100%
33
64
96
130
3000/2700
50%
19
78
148
211
266
Run time chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Longer run times available with Extended Battery Cabinets. Please consult your sales representative for information.
www.eaton.com/powerquality 1300 UPS UPS
31
Premier series 9 protection for low density IT rack environments
Superior de-centralised power protection for medium to high density rack environments
Eaton
9130 Rack
Technology:
Rating:
Voltage:
Configuration:
Series 9, (Double Conversion On Line)
1000 - 3000VA
208240Vac
Rack-mount
The newest Eaton addition, the Eaton 9130 UPS, resolves utility power
problems and delivers superior power protection for IT and networking
equipment, medical systems, manufacturing process control
or anywhere critical equipment and applications require clean,
continuous power.
Double-conversion design for superior power protection The 9130 is
constantly monitoring power conditionsregulating both voltage and
frequency.
Even when presented with the most severe power problems, this UPSs
output remains within three percent of nominal voltage. With a wide
input voltage range, the 9130 does not depend on batteries to smooth
out minor power fluctuations. Batteries are conserved for those times
when utility power is highly unstable or completely out. If an outage
occurs, the 9130 transfers to battery with zero interruption in power,
making this an ideal UPS for sensitive and critical equipment.
More real power for less cost. High 0.9 output power factor enables
the 9130 to provide its full power capability to modern IT equipment
that may have a wide range of leading and lagging power factors.
With a 0.99 input power factor, this UPS avoids the disturbances that
some energy converters tend to cause.
Typical applications:
Servers, networking gear
Telecommunications, VoIP, security systems
Medical systems
Diagnostics and medical screening
Patient record archives
Manufacturing systems
Chip fabrication
Pharmaceutical production
Chemical processing
32
EATON CORPORATION UPS and Power Quality Products Catalogue
Product highlights:
Offers premium performance with a 0.9 power factor and
95% efficiency
Increases battery service life and system uptime with ABM battery
charging technology
Enables prolonged runtime of essential equipment during power
outages by allowing for orderly, remote shutdown of non-critical
systems or processes
Ensures data and system integrity with Intelligent Power software
Options:
Extended Battery Modules for longer run times
Mini Slot connectivity cards
Extended warranty plans
Premier series 9 protection for low density IT rack environments
Eaton 9130 Rack Technical Specifications
1000VA
Rating
1500VA
2000VA
3000VA
Part number
PW9130G1000R-XL2UAU
PW9130G1500R-XL2UAU
PW9130G2000R-XL2UAU
PW9130G3000R-XL2UAU
Capacity (VA/Watts)
1000/900
1500/1350
2000/1800
3000/2700
Dimensions WxDxH(mm)
438x438x86.5 (2U)
438x438x86.5 (2U)
438x600x86.5 (2U)
438x600x86.5 (2U)
Weight (kg)
16.0
19.5
29.0
29.5
Input connection
IEC C14 10A
IEC C14 10A
IEC C14 10A
IEC C20 16A
Output connection
(2) AUST 10A
(4) IEC C13-10A
(2) AUST 10A
(4) IEC C13-10A
(4) AUST 10A
(4) IEC C13-10A
(4) AUST 15A
(4) IEC C13-10A
Operational
Nominal input voltage (Vac)
240Vac (200/208/220/230 selectable)
Input voltage range
700-1500VA: 120/140/160-276 Vac (at 33%/66%/100% 0.7pf load)
2000-3000VA: 140/160/180-276 Vac (at 33%/66%/100% 0.7pf load)
Operating frequency
50/60 Hz auto sensing, tolerance 40-70Hz
Input power factor
0.99
Nominal output voltage
240Vac (200/208/220/230 selectable)
Output voltage regulation
+/-2%
Overload capacity
Up to 130 % for 10 seconds, 130-150% for 2 sec
Efficiency
700-2000VA: 90% online, 93% High Efficiency Mode
3000VA: 91% online, 93% High Efficiency Mode
User interface
LCD display
LCD display showing both UPS meters and UPS settings
LED
Four LEDs; UPS On, UPS on Battery, UPS on bypass, Alarm
Standard communication ports
RS232 and USB as standard on all models
Optional
1 Mini Slot for Network Card-MS, Relay Card-MS or Network & Modbus Card-MS connectivity cards
Environmental
Operating temperature
0C +40C
Storage temperature
-15C +40C
Altitude
< 3000 m
Audible noise at 1 metre
< 52 dBA
Certification
Markings
C-Tick, CE, GS
EMC
EN62040-2 Emisions, category C1; Immunity, category C2
Battery Runtimes (in minutes) Standard Extended Battery Modules
Load (VA/Watts)
% 0f Load
Internal Batteries
w/1 EBM
w/2 EBM
w/3 EBM
w/4 EBM
1000/900
100%
31
51
82
100
500/450
50%
19
68
111
192
246
1500/1350
100%
24
46
69
90
750/675
50%
14
61
112
172
221
2000/1800
100%
33
59
88
119
1000/900
50%
17
72
129
183
260
3000/2700
100%
18
34
53
69
1500/1350
50%
45
84
122
165
PW9130G1000R-XL2UAU
PW9130G1500R-XL2UAU
PW9130G2000R-XL2UAU
PW9130G3000R-XL2UAU
www.eaton.com/powerquality 1300 UPS UPS
33
Premier series 9 protection for medium density rack environments
Eaton 9135
Technology:
Series 9 (Double Conversion On Line)
Rating:
6000VA
Voltage: 208240V
Configuration:
Rack-mount/Tower convertible
The Eaton 9135 UPS resolves power problems and supplies continuous,
conditioned power. You get clean power for valuable IT and networking
equipment, battery backup to gracefully handle utility outages, and
on-demand visibility into UPS status from anywhere.
The 9135 delivers superior power protection for medium-density data
centres, banking and security systems, manufacturing process control,
retail point-of-sale systems and telecommunications/VoIP equipment.
Combining premium performance with innovative features, the 9135 is
an exceptional UPS in its class. Get more usable power for every utility
dollar.
The 9135 provides exactly the level of power protection needed
under the conditions of the momentoptimising for both efficiency
and performance. When this feature is activated, the UPS monitors
incoming power and operates in high-efficiency mode unless power
conditions warrant an automatic switch to double-conversion mode.
With this technology, the UPS can operate at up to 97 percent
efficiency under normal conditionsand up to 91 percent when poor
power conditions require the UPS to work harder to deliver clean
power. High efficiency leads to a greener IT infrastructureone that
uses less energy and dissipates less heat, which in turn reduces
power and cooling costs.
Typical applications:
Servers, networking gear
Telecommunications, VoIP, security systems
Medical systems
Diagnostics and medical screening
Patient record archives
Manufacturing systems
Chip fabrication
Pharmaceutical production
Chemical processing
34
EATON CORPORATION UPS and Power Quality Products Catalogue
Product highlights:
Provides clean, continuous power to protect critical equipment and
applications from power-related downtime, data loss, corruption, and
process interruption
Saves valuable rack space by delivering up to 6000VA/4200W in
only 3U
Provides deployment versatility by offering rack and tower installation
options with rail kits and pedestal provided
Increases availability with hot-swappable batteries and power
module and an optional external maintenance bypass
Offers extended battery runtime options to power essential systems
for more than an hour during an outage
Simplifies UPS monitoring and management with a bright LCD user
interface and Intelligent Power Software Suite
Options:
Mini Slot connectivity cards
Extended battery modules, 3U high
Extended warranty plans
Premier series 9 protection for medium density rack environments
Eaton 9135 Technical Specifications
Rating
6000VA
Part number
PW9135G6000-XL3UEU
Capacity (VA/Watts)
6000/4200
Dimensions WxDxH(mm)
444.5x741x130.6 (3U)
Weight (kg)
57
Input connection
Hardwired
Output connection
Hardwired & (8) IEC C13-10A, (2) IEC C19-16A
Operational
Nominal input voltage (Vac)
230 Vac (208/220/240 selectable)
Input voltage range
156-280V @ 100% load, 120-280V @ 70% load
Operating frequency
50/60 Hz auto sensing, tolerance 40-70Hz
Input power factor
0.95
Nominal output voltage
230 Vac (208/220/240 selectable)
Output voltage regulation
+/-2%
Efficiency
> 91% (Online mode)
> 97% (High efficiency mode)
User interface
LCD display
LCD display showing both UPS meters and UPS settings
LED
Four LEDs; UPS On, UPS on Battery, UPS on bypass, Alarm
Standard communication ports
RS232, USB and Relay Port as standard on all models
Optional
1 Mini Slot for Network Card-MS or Relay Card-MS connectivity cards
Environmental
Operating temperature
0C +40C
Storage temperature
-15C +40C
Altitude
< 3000 m
Audible noise at 1 metre
< 46 dBA
Certification
Markings
C-Tick, CE, TUV(GS)
Safety
EN50091-1-1, EN62040-1-1, IEC60950-1-1
EMC
EN62040-2 C1, AS62040-2 C1
Battery Runtimes (in minutes) Standard Extended Battery Modules
Load (VA/Watts)
Internal Batteries
+1 EBM
+2 EBMs
+3 EBMs
+4 EBMs
1000/700
36
132
232
332
433
2000/1400
13
52
95
140
184
3000/2100
10
40
74
110
146
4000/2800
29
53
80
107
5000/3500
22
41
62
83
6000/4200
17
33
50
67
Run time chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
35
Premier series 9 power protection for medium to high density rack environments
Eaton 9140
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 9 (Double Conversion On line)
7.5 and 10 kVA
1ph/1ph in/out: 230 Vac (200-240 Vac)
3ph/1ph in/out: 380-415/220-240 Vac
7-45 minutes
Rack-mount
Today's racks of IT equipment are requiring even greater power,
from computer rooms and wiring closets to commercial data centres.
Whether you manage the IT needs of a small and medium business or a
commercial facility, you know it is a challenge to provide in-rack power
protection for expanding loads in shrinking spaces.
Fortunately, technology advancements have also raised the power
density of power protection systems. The Eaton 9140 uninterruptible
power system (UPS) delivers efficient, reliable power protection in only
6U of rack space, including batteries.
This double-conversion, online UPS resolves all nine common utility
power problems and supplies clean, continuous power to all connected
equipment. If utility power goes out altogether, there is no delay
transferring to backup power, either to UPS batteries or an auxiliary
generator.
Product highlights:
Conserves valuable rack space, only 6U high including batteries
Pre-installed rack-mount hardware significantly reduces
installation time
Modular lightweight design facilitates installation and improves
service time
Upgradable from 7.5kVA to 10kVA, to accommodate system growth
Input configurable as 1 or 3 phase
ABM prolongs battery life by up to 50%
Options:
ConnectUPS-X Web/SNMP card with in-built switching hub
X-Slot Relay card
Extended battery modules, 3U high
Extended warranty plans
Typical applications:
Critical servers in rack configuration
Telecom rack applications
36
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier series 9 power protection for medium to high density rack environments
Eaton 9140 Technical Specifications
Rating
7.5 kVA
10 kVA
Part number
9140 7500 HW
9140 10000 HW
Capacity (kVA/kilowatts)
7.5 / 6
10 / 8
Dimensions WxDxH (mm)
430 x 760 x 263 (6U)
430 x 760 x 263 (6U)
Weight (kg)
115
115
Input connection
Hardwired
Hardwired
Output connection
Hardwired & (3) IEC C19-16A,
(2) IEC C13-10A
Hardwired & (3) IEC C19-16A,
(2) IEC C13-10A
Typical runtime (Full load)
(Half load)
7 min
18 min
5 min
12 min
Operational
Nominal input voltage (Vac)
220-240 Vac single phase , user selectable to 380/220V, 400/230V, 415/240V, three phase
Input voltage range
174 to 288 Vac single phase, 301 to 499 Vac three phase
Operating frequency
50/60Hz (5Hz)
Input Power factor
> 0.99
Input current distortion
< 5% THD
Nominal Output voltage
220/230/240VAC single phase
Output voltage regulation
2% static , 10% dynamic
Efficiency
> 90%
User interface
LCD-display
Graphical LCD with backlight LCD
languages (English, French, Spanish, German)
LED
4 LEDs for notice and alarm
Communication ports
(1) USB, (1) RS-232 serial, (1) REPO
Communication slot
(1) X-Slot communication bay
Optional
External battery cabinets; Web/SNMP adaptor; AS/400 relay adaptor
Environmental
Operating temperature
0C to +40C
Storage temperature
-20C to +50C
Altitude
< 3000 m
Audible noise at 1 metre
< 55 dBA
Certification
Quality
ISO 9001
EMC Compliance Markings
CE /TUV /C-Tick
Safety Certifications
NOM, TUV, CE
Battery Runtimes (in minutes)
Model/Load
Internal Batteries
+ 1 EBM
+ 2 EBMs
+ 3 EBMs
+ 4 EBMs
1250VA/1000W
80
137
189
275
365
2500VA/2000W
31
61
99
138
181
3750VA/3000W
18
38
68
92
121
5000VA/4000W
12
27
52
69
90
6250VA/5000W
21
42
55
72
7500VA/6000W
17
35
46
60
8750VA/7000W
14
31
40
51
10000VA/8000W
12
27
35
45
EBM run times include internal batteries. Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
37
Premier series 9 Rack/Tower UPS for IT and Industrial applications
Eaton EX RT
Technology:
Series 9 (Double Conversion On Line)
Rating:
5 - 11 kVA
Voltage: 230Vac
Configuration:
Rack/Tower Convertible
Industrial
Compatible with all types of generator sets
Can be integrated into building management systems
Steel casing
Operating temperature up to 45C
High-availability
Meets marine vibration test requirements
Hot swappable UPS and battery modules
Internal bypass and maintenance bypass included as standard
Power management
The UPS can be connected to two independent electrical sources
(sources 1 and 2 can be common or separate)
Software suite on CD Supplied as standard
Large input voltage range without draining the battery: 230V + 20%
to - 30% single phase
Batteries tested automatically at regular intervals and protected
against deep discharge
N+1 redundancy supported by two single units. Wide choice of
backup times
From 10 minutes to 2 hours with battery modules or up to 8 hours using
the CLA charger module
Optional Battery Integration System for automatic recognition of
battery modules and minimising size
Ergonomy
Multilingual LCD display and LEDs for rapid view of the UPS status
and the operating log
Self diagnosis and fault messages
Computer
Tower / 6U Rack convertible
Comprehensive range of Power Distribution Units for convenient
power distribution within the rack
38
EATON CORPORATION UPS and Power Quality Products Catalogue
Optional Network Card-MS SNMP/Webcard Connect to Ethernet,
alarms and supervision using a Web-interface
Environmental Monitoring Probe (EMP) sensor for SNMP/Web card monitoring of temperature + RH + status of 2 contacts
SNMP and Web monitoring of temperature + RH + status of 2 contacts
NMS Supervision through Intelligent Power Manager or NMS
integration kit: HP Openview, Tivoli Netview, CA Unicenter
Network & Modbus Card-MS card for connecting the UPS to a building
management system
Customer Service & Support
1-year warranty, including battery. Associated services:
Warranty extension
Commissioning: startup of your installation conforming to the
manufacturers specifications
Maintenance contracts: a range of convenient
maintenance programmes
Site audit: load analysis and recommendations in line with the
technical environment
Premier series 9 Rack/Tower UPS for IT and Industrial applications
EX RT Technical Specifications
Rating
5 kVA
7 kVA
11 kVA
Part numbers (single phase)
EXRTi5000-XL6U
EXRTi7000-XL6U
EXRTi11000-XL6U
Part numbers (three phase)
EXRTN5000-XL6U
EXRTN7000-XL6U
EXRTN11000-XL6U
Active power kVA / kW
5/4
7 / 4.9
11 / 8
Technology
on-line double conversion with PFC (Power Factor Correction) system
Rated input voltage
200/208/220/230/240/250V single phase, 380/400/415V three phase
Input voltage range
(- 30%, + 20%) 230 V; (- 20%, + 15%) 400 V
Input, output frequency range
40-70 Hz, 50 / 60 HZ autoselection, frequency converter as a standard
Output voltage / THDU
200/208/230/240 /250 V +/- 2%; THDU < 2%
Overall efficiency
normal mode 91%, eco mode 97%
THDI
THDI < 5%
Crest factor / short circuit current
3:1 / 100 A
Overload capacity
>150% 500 ms; 150% 30 s; 125% 60 s; 110% 120 s
Temperature operating
45C for 8 Hrs(1), 40C continuous
Performances
3:1 / 150 A
Back-up times(2) at 70% load
from 10 up to 15 minutes
Standard: 1 power mod. 3U + 1 battery mod. EXB 3U = 6U
from 15 up to 20 minutes
Standard + 1 battery mod. EXB 3U = 9U
from 40 up to 65 minutes
Standard + 2 battery mod. EXB 3U = 12U
Connection
terminal block for 13 mm2 (stranded cable) or 10 mm2 (solid cable)
Input /output
Communication
Port type
6 voltage free contacts DB9 2 A 48 V DC, 1 RS 232, RJ11 for remote emergency power off
Slot
1 Mini Slot for Network Card-MS, Relay Card-MS or Network & Modbus Card-MS connectivity cards
Standards and certification
Performance and safety
IEC 62040-1/IEC 60950
EMC
IEC 62040-2; EN 50091-2
Certification
TV, GS mark,CB, C-Tick,CE, IEC 68-2-6 (vibration tests Marine approval)
Dimensions (H x W x D) in mm; weight (single phase input / three phase input)
EX RT standard backup tower
444.5 x 261.2 x 700
EX RT standard backup rack mounting
261.2 (6U) x 444.5 x 700
89.5 Kg
97.3 Kg
Comet EX RT Power module
94.2 Kg / 95.3 Kg
96.1 Kg / 97.3 Kg
102 Kg / 103.1 Kg
23 Kg / 24.2 Kg
24.9 Kg / 26 Kg
64.5 Kg
68.5 Kg
444.5 x 130.6 x 700 / 130.6 (3U) x 444.5 x 700
24.2 Kg
Battery module EXB RT
88.3 Kg / 89.5 Kg
444.5 x 130.6 x 650 / 130.6 (3U) x 444.5 x 650
64.5 Kg
EX RT CLA module / EX RT Transformer
130.6 (3U) x 444.5 x 650 / 12 Kg / 87 Kg
1: at nominal output power for 230 V or 400V input and 230V output. 2: typical values after 3 discharge cycles, batteries 3-5 years, longer backup times available using the CLA or EXB module, ask
for details.
www.eaton.com/powerquality 1300 UPS UPS
39
Premier series 9 protection for centralised mission critical loads
Eaton 9155
Product highlights:
Hot Sync redundancy
ABM providing up to 50% longer battery life time
Active input power factor correction (PFC) providing 2-5%
THD(i) harmonics
High 0.9 p.f. output rating for server and high computer loads
Market leading internal battery runtime
User friendly graphical LCD display with light blue back light
Web/SNMP and ModBus monitoring capability
Intelligent Power Software Suite bundled
In-built Maintenance Bypass Switch on 20-30kVA models,
optional on 8-15kVA models
Options
System Parallel Cabinets for Hot Sync
Capacity/Redundancy Solutions
External Maintenance Bypass Switches
Extended Battery Cabinets
X Slot connectivity options
ViewUPS-X remote monitoring panel
Preventative maintenance contracts
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 9 (Double Conversion On line)
8-30kVA
220-240/380-415 Vac, 50/60 Hz
Typical 5-33 min internal (extendable
up to several hours)
Cabinet
Eaton 9155 are Series 9 UPS designed to protect high 0.9 p.f. rated,
critical computers and servers. The centralised UPS protection is an
essential part of IT infrastructure in todays IT, telecom, healthcare,
banking and industrial automation applications. The 9155 features
active input power factor control (PFC) and low 2-5% Total Harmonic
Distortion (current) with IGBT rectifier technology
The Eaton 9155 operate using the unique ABM function. While
traditional UPS charges batteries continuously, ABM charges
batteries only when necessary, thus preventing battery corrosion. The
exceptional ABM function prolongs the service life of batteries by up
to 50%.
Typical applications:
High-capacity computers
Server rooms
Networks
Process automation, control equipment
Telecommunication applications
Offshore, military and special projects
40
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier series 9 protection for centralised mission critical loads
Eaton 9155 Technical specifications
Rating
Model
8 kVA
9155-8-S
9155-8-N
10 kVA
9155-10-S
9155-10-N
12 kVA
9155-12-N
15 kVA
9155-15-N
20kVA
9155-20-N-MBS
30kVA
9155-30-N-MBS
Capacity (kVA/kilowatts)
8 / 7.2
10 / 9
12 / 10.8
15 / 13.5
20 / 18
30 / 27
Dimensions WxDxH (mm)
305x702x817
305x702x817
305x702x817
305x702x817
494x762x1684
494x762x1684
With extra runtime
305x702x1214
305x702x1214
305x702x1214
305x702x1214
70
70
70
70
200
200
165
165
165
300
N/A
270
270
270
400
400
N/A
N/A
N/A
500
500
N/A
N/A
N/A
600
600
Weight (kg)
UPS without batteries
165
UPS with internal 1xBAT
270
UPS with internal 2xBAT
N/A
UPS with internal 3xBAT
UPS with internal 4xBAT
N/A
Typical runtime UPS+1xBAT
15 min
10 min
8 min
5 min
5 min
N/A
UPS+2xBAT
33 min
25 min
20 min
15 min
13 min
7 min
Operational
Nominal input voltage (Vac)
S models: 220/230/240 Vac single phase;
N models: 220/380, 230/400, 240/415 Vac three phase
Input voltage range
175/305V - 276/478V at 100% load, 115/200V - 276/478V at 50% load
Operating frequency
50/60 Hz (45 to 65 Hz)
Input power factor
0.99 (5% THD)
Input current distortion
5% THD in normal network condition
Nominal output voltage
220/230/240VAC single phase
Output voltage regulation
2% static;
5% dynamic at 100% load change, < 1 ms response time
Overload capacity
150% for 5 sec / 125% for 1 min (online),
1000% for 20 msec (bypass)
Efficiency
92% with computer load; 93% with linear load
User interface
LCD-display
Graphical LCD with blue backlight, English, German and Spanish languages, extendable
LED
4 LED for notice and alarm
Standard communication
ports
1 x RS232 for local support, 2 x X-slot (empty);
1 x relay contact, 1 x emergency power off input, 2 x environmental input
Optional
External battery cabinets; isolation transformer;
external mechanical bypass switch; X-slot; Web/SNMP, Modbus/Jbus, Relay, Hot Sync cards
Environmental
Operating temperature
0C to +40C
Storage temperature
-15C to +40C
Altitude
< 1000 m at +40C, < 3000 m at +25C
Audible noise at 1 metre
< 50dBA at 1 metre
Certification
Quality
ISO 9001; 2000 and ISO 14001:1996
Markings
CE and GOST markings / C-Tick
Safety
IEC 62040-1-1, IEC 60950, EN 62040-1-1
EMC
EN 50091-2 Class A, C-Tick
www.eaton.com/powerquality 1300 UPS UPS
41
Premier series 9 scalable UPS
Eaton MX & MX Frame
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 9 (Double Conversion On Line)
4-20kVA
220-240/380-415 Vac, 50/60 Hz
Typical 5-33 min internal (extendable
up to several hours)
Rack/Tower convertible
The Eaton MX4000 and MX5000 UPS can be paralleled to provide 8kVA
or 10 kVA using the Modular Easy Kit without extra cost on the initial
purchase. The MX frame is a modular system with 5kVA sub-modules
paralleled to provide up to 20kVA or 15kVA with redundancy.
Minimum total cost of ownership (TCO)
More power with an output power factor of 0.9
When the power supply needs to be upgraded, the Eaton MX 4000 and
5000 can be paralleled to provide 8 kVA or 10 kVA using the Modular
Easy kit: without extra cost on the initial purchase
Eaton MX Frame is a modular system with 5 kVA sub-modules
paralleled to provide up to 20 kVA or 15 kVA with redundancy
Continuous power supply
Two front access hot-swappables sub-modules (power and battery) for
maintenance without load interruption
Automatic battery test (test period can be set)
Internal bypass built-in to supply the load even if the UPS fails
Large input voltage and frequency ranges to avoid using the
batteries unnecessarily
Total flexibility
Can be used as a free-standing tower unit with casters or 19
rack-mounted: only 3U for Eaton MX 4000 and 5000, 16U for Eaton
MX Frame
LCD multilingual display with mimic and LEDs for rapid view of the UPS
status, diagnostics and event log
Outputs: IEC 10A and 16A outlet sockets and hardwired outputs.
Built-in Powershare system for remote reboot of the equipment
connected, sequential start-up or load shedding while operating from
battery to maintain the power to critical loads
Eaton MX Frame
Eaton MX Frame is compatible with three phase or single
phase supplies
Backup time: 10 mins up to 2 hours by adding 3U battery
extension modules
42
Advanced protection for:
EATON CORPORATION UPS and Power Quality Products Catalogue
Departmental networks, servers and workstations
Premier series 9 scalable UPS
8 x IEC 10A sockets
DB 9 with 5 output contacts
Retention clips
DB 9 serial and USB ports
2 x IEC 16A sockets
DB 15 for paralleling
Output circuit protection
EXB battery extension module power connector
1 x Mini Slot for connectivity cards
Input
RJ11 remote power off
Output
RJ45 EXB battery module detection
Eaton MX 4000/5000
Eaton MX Technical Specifications 4000
5000
MX Frame 15000
MX Frame 20000
Rating (kVA/kW)
4 kVA / 3.6 kW
5 kVA / 4.5 kW
15 kVA / 13.5 kW
20 kVA / 18 kW
8 kVA / 4 kVA + 4 kVA
redundancy
10 kVA / 5 kVA + 5 kVA
redundancy
15 kVA / 10 kVA + 5 kVA redundancy 20 kVA / 15 kVA + 5 kVA redundancy
5 kVA + 2 x 5 kVA redundancy
10 kVA + 2 x 5 kVA redundancy
Paralleling
Maximum rating / redundancy(1)
Inputs
Technology
Number of phases, input connections
VFI-SS-113, on-line double conversion with power factor correction, convection cooled static bypass switch
L + N, terminals up to 6 mm2
L + N, terminals up to 6 mm2 L + N or 3P + N, terminals up to 35 mm2, separate or common
AC normal and AC bypass
Nominal voltage
200/208/220/230/240/250 V
200/208/220/230/240/250 V
200/208/220/230/240/250 V (L + N) or 380/400/415 V (3P + N)
Voltage range without using battery(2)
120 - 280 V
120 - 280 V
120 - 280 V (L + N), 250 - 465 V (3P + N)
Input frequency range, THDI
40-70 Hz, < 7%
Outputs
Output connections (3)
Terminals + 8 x IEC C13 (10A) + 2 x IEC C19 (16A)
Remotely controlled Powershare sockets
Output voltage and frequency(4), THDU, efficiency(5)
2 groups (2 IEC C13 10A per group)
Terminals + 8 x IEC C13 (10A) + 4 IEC C19 (16A), sockets, except on -HWOP models
200/208/230/240 /250 V, 50 / 60 Hz autoselect, frequency converter as standard, <2%, 97%
Backup time(6)
Eaton MX standard backup time
Eaton MX + EXB / MX + 2 EXB / MX + 3 EXB
10 minutes
45 / 80 / 120 minutes
8 minutes
35 / 60 / 95 minutes
8 minutes
35 min (3 EXB)/60 min (6 EXB)
/90 min (9 EXB)(7)
8 minutes
35 min (4 EXB)/60 min (8 EXB)
/90 min (12 EXB)
Communications
Slots
1 Mini Slot (MX) or 2 Mini Slot (MX Frame) for Network Card-MS, Relay Card-MS or Network & Modbus Card-MS connectivity cards
Remote Power off (RJ11), 5 output contacts (DB9), setup via Solution-Pac(8) , (USB and DB9-serial ports), EXB detection (RJ45), paralleling (DB 15)
Ports
Operating conditions, standards and approvals
Performance, safety, EMC, surge protection
Operating temperature, noise, approvals, guarantee
IEC/EN 62 040-3, IEC/EN 62 040-1-1, IEC/EN 62 040-2 class A (class B as option), 4 kV IEC 61 643, UL 1778 and CSA 22.2(9)
0C to 40C continuous, 45 dbA(10), UL, TV, GS mark, CB, C-Tick, CE, IEC 61 931, one year (11)
Dimensions H x W x D / Weight
Eaton MX standard backup tower
444.5 mm x 130.6 mm x 735 mm / 57 kg
Tower 690 mm high (795 mm casters) x 444.5 mm wide x 735 mm deep / 250 kg
Eaton MX standard backup rack
3U x 444.5 mm wide compatible with 800-1000 mm deep rack
Rack 16U x 444.5 mm wide, compatible with 800-1000 mm deep rack
Eaton MX EXB battery unit tower / rack
444.5 mm x 130.6 mm x 650 mm / 3U x 444.5 mm wide / 70 kg
Dimensions same as MX Frame / 194 kg for 15 kVA, 239 kg for 20 kVA
Eaton MX ModularEasy, paralleling kit
Dimensions same as EXB battery unit / 10 kg
Customer Service & Support
1 year guarantee, including batteries.
Warranty+
Optional 3-years warranty (depending on the country please visit www.eaton.com/powerquality)
1: Eaton MXs can be paralleled using ModularEasy. 2: At 70% load. 3: 4 IEC C13 (10A) 2 m long cables for use with retention clips (8 cables for use with Eaton MX Frame). 4: Frequency conversion for non-paralleled units only.
5: Economy mode, 91% in normal mode. 6: At 70% nominal rating with power factor 0.7 typical values after 3 charge/discharge cycles, with 3-5 years old batteries. Weekly battery test without interrupting the load (daily or monthly if
required). EXB compatible with 0.8 power factor loads. 7: With Eaton MX Frame EXB (4 battery units). 8: Solution-Pac CD-ROM supplied as standard. 9: Applicable to US models. 10: 50 dbA above 5 kVA. 11: Depending on the country,
see www.eaton.com/powerquality.
Part Numbers
MX 4000
MX 5000
Eaton MX Tower or rack-mounting: standard backup time
M68501
M68504
MX Frame 15000 MX Frame 20000
M68513(1)
Eaton MX EXB: battery extension module
Eaton MX ModularEasy: paralleling kit (2 Eaton MX)
Eaton MX / EXB Rack Kit: rail kit for 19 rack mounting
IEC 32 A kit , 2 X 2 m long cables: male to hardwired and female to hardwired
MX 1,8 m Battery extension cable
MX Battery / Power electronics sub-module
Eaton MX Frame empty chassis
Battery Integration System (up to 9 EXB)
M68515
M68520
M68002
M68525
M68528
M68524 / M68522
/
/
M68515
M68520
M68002
M68525
M68528
M68524 / M68523
/
/
add multiple MX EXB : M68515
/
/
/
/
/
/
M68528
M68528
M68524 / M68523
M68524 / M68523
M68526
M68526
M68527
M68527
M68514(2)
1: (with rack kit, casters, NMC card) M68513 = M68526 (empty Eaton MX Frame) + 3 x M68524 + 3 x M68523. 2: (with rack kit, casters, NMC card) M68514 = M68526 (empty Eaton MX Frame) + 4 x M68524 + 4 x M68523.
www.eaton.com/powerquality 1300 UPS UPS
43
Essential series 9 Three Phase UPS
Eaton E Series DX
Typical applications
Computers and Peripherals
POS Equipment
PLC Systems
Security Systems
Features
On-line double conversion topology assures maximum reliability
High Frequency technology allows a compact design that delivers
perfect sine wave output.
Intuitive front-panel LCD user interface for consistent status indication
0.8 Power Factor output
Internal battery option for short run times
Tested for generator compatibility
Automatic bypass for fault-tolerance
Built in maintenance bypass switch
Parallelable for N+X capacity & redundancy
WINPOWER software monitors power conditions
Options
SNMP/Web Card
Technology: Series 9 (Double Conversion On Line)
Rating: 20kVA 40kVA
Voltage: 380-415 Vac, 50/60Hz
Backup Time: Typical 5-14 min internal (extendable up to several hours)
Configuration: Tower
Modbus Card
External Maintenance Bypass Switch
Extended Battery Cabinets
The Eaton E Series DX is a three-phase, double conversion
uninterruptible power supply (UPS), and is available in 20, 30 and 40kVA
output power ratings. Its design fits perfectly to any environment where
uninterrupted power feed is required to secure critical equipments
continuous operation. The E Series DX UPS provides a perfect solution
for power protection, and solves power quality problems such as surges,
spikes, voltage fluctuations, harmonic distortion, clutter interference and
frequency fluctuations.
With E series DX, each phase is independently double converted and
regulated. In addition a PFC (power factor control) controller is used for
real time control and data processing, ensuring high availability at all
times. Further reliability is accomplished by introducing an intelligent
charge mode which significantly prolongs service life of batteries. Also,
the possibility to have dual feed on UPS input adds availability and
increases reliability of the system.
The E-Series DX is available in two cabinet configurations that
accommodate internal/external batteries or external batteries only.
As an added benefit, IP21 compliant design makes E Series DX a perfect
fit for industrial and other applications, with harsh environmental
conditions. An optional filter is also available for further protection
against the smallest damaging particles.
44
EATON CORPORATION UPS and Power Quality Products Catalogue
Essential series 9 Three Phase UPS
Description
kVA
Standard models
using external battery
solution
20
Eaton E Series DX 20 kVA
EDX20K4E, EDX20K4AU
82
420 x 643 x 956
30
Eaton E Series DX 30 kVA
EDX30K4E, EDX30K4AU
135
470 x 710 x 1150
Standard models with
space for internal
batteries
Standard models with
internal batteries
installed
Model description
Part number
Net weight (kg)
Dimensions (WxDxH mm)
40
Eaton E Series DX 40 kVA
EDX40K4E, EDX40K4AU
140
470 x 710 x 1150
20
Eaton E Series DX 20 kVA B
EDX20K4EB, EDX20K4AUB
120
420 x 710 x 1245
30
Eaton E Series DX 30 kVA B
EDX30K4EB, EDX30K4AUB
195
470 x 710 x 1753
40
Eaton E Series DX 40 kVA B
EDX40K4EB, EDX40K4AUB
195
470 x 710 x 1753
20
Eaton E Series DX 20 kVA BI
EDX20K4EBI, EDX20K4AUBI
272
420 x 710 x 1245
30
Eaton E Series DX 30 kVA BI
EDX30K4EBI, EDX30K4AUBI
515
470 x 710 x 1753
40
Eaton E Series DX 40 kVA BI
EDX40K4EBI, EDX40K4AUBI
515
470 x 710 x 1753
eaton E Series DX 3 Phase Technical specifications
Input
Nominal Voltage
Operating environment
380/400/415 Vac (L-L)
Temperature
0C to 40C
220/230/240 Vac (L-N)
Humidity
20% to 90% non-condensing
Frequency
40-65 Hz (self-adaptive to 50 Hz and 60 Hz)
Efficiency
Wiring
3-Phase + N + PE
Line mode
92%
THD i
<5%
HE mode (high
efficiency)
98%
Power factor
>0.99
Display
Dual-line input
Supported
LCD
UPS status and operating instructions. Input voltage,
output voltage, current, frequency, charger voltage and
current, fault and warning display.
LED
UPS operation status
Battery
Type
Maintenance free VRLA batteries
Backup time
Up to 15 min with internal batteries on 20-40kVA, more
with external batteries
Battery Voltage
360 V (30x12 V, 180 cells), 20kVA internal battery model
384 V (32x12 V, 192 cells), all other models
Warning equipment
Buzzer alarm and light double LED
Communication interface
Output
Voltage
380/400/415 Vac (L-L) 220/230/240 Vac (L-N)
Frequency
50/60 Hz
Phase
Three-phase four wire + ground
Power factor
0.8
Overload capability
125% 10 minutes, 150% 1 minute
RS-232, AS/400, RS485, service, EPO, interface for
battery temperature sensor, intelligent communications
slot
Runtime for 20-40kVA UPS with internal batteries p.f. 0.7 (typical IT server/computer load)
Battery
Qty
20
30
40
kVA
7 Ah 12 V
2 x 30
min
9 Ah 12 V
2 x 30
10
min
7 Ah 12 V
3 x 32
min
9 Ah 12 V
3 x 32
10
min
7 Ah 12 V
4 x 32
11
min
9 Ah 12 V
4 x 32
15
10
min
Run time chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
www.eaton.com/powerquality 1300 UPS UPS
45
Premier Three-phase UPS for servers and industrial applications
Eaton 9355
Product highlights:
Hot Sync redundancy
ABM providing up to 50% longer battery life time
Active input power factor correction (PFC) providing 2-5%
THD(i) harmonics
High 0.9 p.f. output rating for server and high computer loads
Market leading internal battery runtime
User friendly graphical LCD display with light blue back light
Web/SNMP and ModBus monitoring capability
Intelligent Power Software Suite bundled
In-built Maintenance Bypass Switch on 20-40kVA models,
optional on 8-15kVA models
Options:
System Parallel Cabinets for Hot Sync
Capacity/Redundancy Solutions
"UPS Centre" distribution cabinets for small computer room
applications
External Maintenance Bypass Switches
Extended Battery Cabinets
X Slot connectivity options
ViewUPS-X remote monitoring panel
Preventative maintenance contracts
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Series 9 (Double Conversion On Line)
8-40 kVA
380-415 Vac, 50/60 Hz
Typical 5-33 min internal (extendable
up to several hours)
Cabinet
Eaton 9355 are Series 9 UPS designed to protect high 0.9 p.f. rated,
critical computers and servers. The centralised UPS protection is an
essential part of IT infrastructure in todays IT, telecom, healthcare,
banking and industrial automation applications. The 9355 features
active input power factor control (PFC) and low 2-5% Total Harmonic
Distortion (current) with IGBT rectifier technology.
The 9355 operate using the unique ABM function. While traditional
UPS charges batteries continuously, ABM charges batteries only
when necessary, thus preventing battery corrosion. The exceptional
ABM function prolongs the service life of batteries by up to 50%.
Typical applications:
High-capacity computers
Server rooms
Networks
Process automation, control equipment
Telecommunication applications
Offshore, military and special projects
46
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier Three-phase UPS for servers and industrial applications
Eaton 9355 Technical Specifications
Rating
8kVA
10kVA
12kVA
15kVA
20kVA
30kVA
40kVA
Model
9355-8-N
9355-10-N
9355-12-N
9355-15-N
9355-20-N-MBS
9355-30-N-MBS
9355-40-N-MBS
Capacity (kVA/kilowatts)
8 / 7.2
10 / 9
12 / 10.8
15 / 13.5
20 / 18
30 / 27
40 / 36
Dimensions (mm) WxDxH
305 x 702 x 817
494 x 762 x 1684
With extra runtime
305 x 702 x 1214
Weight (kg)
UPS without batteries
UPS with internal 1xBAT
UPS with internal 2xBAT
UPS with internal 3xBAT
UPS with internal 4xBAT
75
165
N/A
N/A
75
165
275
N/A
N/A
75
165
275
N/A
N/A
75
165
275
N/A
N/A
200
300
400
500
600
200
N/A
400
500
600
217
N/A
N/A
517
617
Input Connection
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Output Connection
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
*Typical runtime with 1xBAT
Typical runtime with 2xBAT
Typical runtime with 3xBAT
Typical runtime with 4xBAT
15 min
33 min
N/A
N/A
10 min
25 min
N/A
N/A
8 min
20 min
N/A
N/A
5 min
15 min
N/A
N/A
5 min
13 min
22 min
31 min
N/A
7 min
13 min
20 min
N/A
N/A
8 min
12 min
Operational
Nominal input voltage (Vac)
220/380, 230/400, 240/415 Vac three phase
Input voltage range
175/305V - 276/478V at 100% load, 115/200V - 276/478V at 50% load
Operating frequency
50/60 Hz (45 to 65 Hz)
Input power factor
0.99
Input current distortion
5% THD in normal network condition
Nominal output voltage
380/400/415 three phase
Output voltage regulation
2% static;
5% dynamic at 100% load change, < 1 ms response time
Overload capacity
150% for 5 sec / 125% for 1 min (online),
1000% for 5 msec (bypass)
Efficiency
92% with computer load; 93% with linear load
User interface
LCD-display
Graphical LCD with blue backlight, English, German and Spanish languages, extendable
LED
4 LED for notice and alarm
Standard communication ports
1 x RS232 for local support, 2 x X-Slot (empty);
1 x relay contact, 1 x emergency power off input, 2 x environmental input
Optional
External battery cabinets; isolation transformer; external mechanical bypass switch; X-Slot;
Web/SNMP, Modbus/Jbus, relay card, RS232 port, Hot Sync card
Environmental
Operating temperature
0oC to +40oC
Storage temperature
-15oC to +40oC
Altitude
< 1000 m at +40oC, < 3000 m at +25oC
Audible noise at 1 metre
< 50dBA at 1 metre
Certification
Quality
ISO 9001; 2000 and ISO 14001: 1996
Markings
CE and GOST markings / C-Tick
Safety
IEC 62040-1-1, IEC 60950, EN 62040-1-1
EMC
EN 50091-2 Class A, C-Tick
www.eaton.com/powerquality 1300 UPS UPS
47
Premier Rack Mount 3 Phase UPS for Data Centre & IT Applications
Eaton BladeUPS
Typical applications:
Data centres with rack mount blade servers
Telecommunications
Product highlights:
Minimum efficiency of >98% in normal operation
Easy to install, configure and deploy
Fits into standard 19" rack cabinets
Hot-swappable battery and electronics modules
Parallel for capacity/redundancy
Hot Sync redundancy
Decentralised bypass ensures no single failure point
ABM prolongs battery life by up to 50%
Options:
X Slot connectivity options
Technology:
Rating:
Voltage:
Backup time:
Configuration:
Double Conversion On Line, On Demand
12 to 60 kW N+1 using 12 kW modules
400 Vac, 50/60 Hz
5 minutes typical, extendable
Rack-mount
Power Xpert software
Eaton eNotify remote monitoring and diagnostic service
Eaton BladeUPS is the first product on the market to offer a "Online,
Double Conversion On Demand" power technology. This innovative
design takes into consideration the design capabilities of the actual
computer power supplies in such a manner that the UPS furthers
that capability in order to provide an extremely efficient and robust
protection solution without generating additional heat.
The BladeUPS is a rack-mounted three-phase input and three-phase
output uninterruptible power system. Each 12kW module can be
paralleled to achieve a maximum 60 kW N+1 system. Paralleling can be
accomplished for either redundancy or capacity purposes. Each 12 kW
module is identical and can be converted from a single stand alone UPS
to a system capable of being paralleled by simply changing the power
cord. The BladeUPS is designed for computer data centre installations.
Paralleling of the BladeUPS modules takes place in the BladeUPS bar,
which is mounted separately in the rear of the IT rack. This bar provides
the required input and output power connections for 4 or 6 BladeUPS
modules. Each BladeUPS bar comes equipped with fully rated input and
output lugs within a designated wiring area. The protected load can be
connected to the wiring section, or distributed output can be taken in
12 kW increments from the locking output connector on the rear of the
BladeUPS module.
A single BladeUPS module can be connected to the BladeUPS bar, with
additional modules installed to meet future power demands.
48
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier Rack Mount 3 Phase UPS for Data Centre & IT Applications
BladeUPS - Scalability
Meet current and changing requirements with modular architecture
The building block of the Eaton BladeUPS system is a 6U rack-mount
module that provides 12 kW of backup power protection. The system
expands easily to provide maximum results. As your data centre
grows, the systems modularity plays a key role in optimising your
capital planning and deployment. Using the patented and field-proven
Hot Sync paralleling technology, up to six BladeUPS modules can
be paralleled for extra capacity or redundancy, providing 60 kW of
redundant backup power protection in one 19 inch rack.
YEAR 1:
Patented load-sharing control intelligently distributes the workload
among modules without requiring direct synchronisation links among
them. Any module can provide backup support for any other, with no
interruption or downtime. For instance, in a redundant system you could
perform full maintenance on any module without any interruption of
conditioned power to the protected IT equipment.
YEAR 3:
INITIAL INSTALL
YEAR 5:
EXPANSION
FURTHER EXPANSION
BladeUPS
Redundant N+1 configuration:
Parallel Bar for
Six 12 kW UPS modules share
paralleling UPS
the load equally. If a UPS
modules
module is removed from
service, the remaining
modules seamlessly support
the load without interruption.
42U Eaton
Enclosure
Three 12 kW UPS
modules = 36 kW
Total Rack
of backup power
Space: 24U
12 kW
6U electrical
Eaton
wire-way
BladeUPS occupies
6U of space
12kW
36kW or 24kW, N+1
60kW, N+1
* Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Runtimes at 0.7 pf.
www.eaton.com/powerquality 1300 UPS UPS
49
Premier protection for high availability systems
Eaton 9390
Product highlights:
High efficiency - up to 94%
Parallel systems with Hot Sync redundancy and scalability
ABM providing up to 50% longer battery life
Active input Power Factor Correction (PFC) providing up to 5%
THD(i) harmonics
High output power factor for PFC controlled server and computer loads
Energy Saver System increases efficiency to 99%
SNMP/Web communication offered as standard or optional
User friendly graphical LCD display with multi-language support
Built-in mechanical bypass switch (40-80kVA)
Easy Capacity Test enables load testing without external load banks
Top and bottom cable entry
Options:
Systems Parallel cabinets for Hot Sync
Capacity/Redundancy Solutions
Wall-mounted external bypass switch modules
Static Transfer Switch
X-Slot communication options
ViewUPS-X remote monitoring panel
Long-life battery cabinets and racks
Sync Control option for use with Static Transfer Switches
Eaton eNotify remote monitoring and diagnostic service
Preventative maintenance contracts
Technology:
Series 9 (Double Conversion On Line)
Rating:
40-160 kVA at 0.9 p.f.
Voltage:
230/400VAC50/60 Hz
Backup:
10-90 min
Configuration: Cabinet
Eaton 9390 provides unmatched power performance for input harmonics,
efficiency and output power factor. Its scalable for capacity and
redundancy to meet the present and future power needs. 9390 provides
peace-of-mind and resolves all utility power problems. Whether youre
selecting a UPS for a branch office, manufacturing floor, medical facility,
or a large data centre, theres a 9390 model that delivers just the right
combination of performance and price for your needs.
Typical applications:
Data centres, server farms
Building, banking and telecommunication systems
Industrial automation equipment
Healthcare systems
50
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier Power protection for high availability systems
Eaton 9390 Technical Specifications
Rating
40 kVA
60 kVA*
80 kVA
100 kVA*
120 kVA*
160 kVA
Part number
939040N4X0-MBS
939060U4X0-MBS
939080N4X0-MBS
9390100U4X0
9390120N4X0
9390120U4X0
9390160N4X0
Capacity (kVA/kilowatts)
40/36
60/54
80/72
100/90
120/108
160/144
Dimensions WxDxH (mm)
519 x 804 x 1872
519 x 804 x 1872
519 x 804 x 1872
944 x 804 x 1872
944 x 804 x 1872
944 x 804 x 1872
Weight (kg) UPS only
285
313
313
480
480 (N Model)
530 (U Model)
530
Input connection
Dual Input, Hardwired
Output connection
Hardwired
Operational
Nominal input voltage (Vac)
220/380, 230/400, 240/415VAC 50/60 Hz
Input voltage range
190/330V - 276/478V at 100% load, 161/279V - 276/478V at 50% load
Operating frequency
50 Hz or 60 Hz (45 to 65 Hz)
Input power factor
0.99
Input current distortion
<5% THDi typical
Nominal output voltage
220/380, 230/400, 240/415VAC
Output voltage regulation
1% static, 5% dynamic at 10% to 90% load change, < 1 ms recovery time
Overload capacity
101-110% for 10 min
111-125% for 1 min
126-150% for 10 sec
1000% for one cycle (bypass)
Efficiency
up to 94% (99% in Energy Saver System mode)
User interface
LCD display
Graphical LCD with blue backlight
LED
4 status indicators
Standard communication ports
4 x X-Slot, 1 x relay contact,
1 x Emergency power off input, 2 x environmental inputs
Options
External battery cabinets and racks; system parallel cabinets; external maintenance bypass;
X-Slot: SNMP/Web/HUB, ModBus, Relay card, Hot Sync cards
Environmental
Operating temperature
0C to +40C, +45C with 7.5% derating, batteries max +25C
Storage temperature
-15C to +45C
Altitude
< 1500 m
Audible noise at 1 metre
55dBA 40 kVA; 62dBA 60-80 kVA
65dBA 100-120 kVA; 70dBA 160 kVA
Certification
Quality
ISO 9001 : 2000, ISO 14001 : 1996
Markings
CE / C-Tick
Safety
IEC 62040-1-1; IEC 60950; EN62040-1-1
EMC
EN 50091-2
* 'U' models are upgradeable to next model rating.
www.eaton.com/powerquality 1300 UPS UPS
51
Premier High Efficiency UPS Solutions 200 - 1100kVA
Eaton 9395
Features:
Delivers the highest reliability and availability for large, mission-critical
systems by integrating a redundant multi-module UPS (including the
System Bypass Module) into a single, pre-wired unit
Grows with changing power requirements with scalable architecture
that allows you to add another 275 kVA module on-site later for capacity
or redundancy
Eliminates the need to switch to bypass for service with concurrent
serviceability: One redundant 275 kVA module can be isolated and
serviced while the other is online
Provides unmatched power performance for efficiency, input current
harmonic distortion (THD), and power factor
Ensures battery reliability with innovative ABM three-stage charging
system, battery health-checks, optional temperature-compensated
charging, and remote monitoring
Lowers installation time and costs with small footprint and the flexibility
to install against walls using top- or bottom-entry cabling and by
eliminating the need to run inter-unit cabling on-site with pre-wired
configuration
Integrates seamlessly with PowerXpert software to enable you to
monitor and manage the UPS, as well as the entire power system,
including all upstream and downstream switchgear
The Eaton 9395 uninterruptible power system (UPS) is a doubleconversion UPS that resolves all utility power problems and supplies
clean, continuous, uninterruptible power to connected equipment.
Whether youre selecting a UPS for a branch office, manufacturing floor,
medical facility, or a large data centre, theres a 9395 model that delivers
just the right combination of performance and price for your needs.
Taking large system mission critical reliability to the next step. The 9395
combines the reliability and redundancy of a multi-module UPS into an
integrated, pre-wired solution. Built with up to 275 kVA building blocks,
the 9395 features N+1 internal redundancy, which allows one 275 kVA
module to automatically carry the load in the event the other module is
out of service.
Advanced design delivers unequalled power performance. The
innovative design of the 9395 delivers the industrys best performance
combination of efficiency, input current distortion and power factor. The
9395 operates at a high efficiency of up to 99%, reducing utility costs
and extending battery runtimes. Higher system efficiency produces
cooler operating conditions, which reduces facility air conditioning
cost, extends the life of UPS components, and increases overall
reliability, availability, and performance. A new input circuit design
keeps input current THD low and input power factor near unity without
compromising overall efficiency.
Eaton's Energy Advantage Architecture
9395 features maximised energy efficiencies with Energy Advantage
Architecture (EAA): Variable Module Management System (VMMS)
optimises system efficiency at low load levels and Energy Saver System
(ESS) allows dramatic increase in UPS efficiency without sacrificing load
protection.
52
EATON CORPORATION UPS and Power Quality Products Catalogue
Premier High Efficiency UPS Solutions 200 - 1100kVA
Eaton 9395 UPS with redundant, field-installed module
275 kVA field-upgradable
UPS-U can be added for
redundancy
550 kVA Integrated system bypass
module (ISBM)
Redundant 275 kVA
uninterruptible power system
Eaton 9395 Technical Specifications
UPS rating
Dimensions (W x D x H)
Weights
kVA
200 225 275 300 400 450 550 600 825 1100
200kVA
1350x880x1800 mm
810 kg
kW
180 202 250 240 360 405 500 480 750 1000
225,275 and 300kVA
1350x880x1880 mm
830 kg
400kVA and 200kVA redundant
1890x880x1880 mm
1390 kg
550/600kVA and 275/300kVA redundant
1890x880x1880 mm
1430 kg
550 kVA redundant
2520x880x1880 mm
2030 kg
275 kVA field upgrade UPS-U
740x880x1880 mm
600 kg
825 kVA
3710x880x1880 mm
3460 kg
1100 kVA
4450x880x1880 mm
3460 kg
General characteristics
Efficiency
Up to 95%
Parallel capability
Up to 5 modules
Audible noise
75 to 81.5dBA @ 1m, model dependant
Altitude (max)
1000 m at 40C
Internal N+1
redundance capable
Yes
Field upgradeable
for redundancy
System bypass module
Included
Input characteristics
User benefits
Control panel (LCD)
8 lines x 40 characters
Frequency conversion
Optional
Remote display panel
Optional
Buildings alarm inputs
2 (galvanic isolated)
Voltage
415
Voltage range
+15% / -20%
Frequency range
45-65 Hz
Power factor
0.99
Input current distortion
3-5% in nominal load condition
Back/side against wall installation
Soft start capability
Yes
Optional accessories
Internal backfeed
Protection
Yes (except on 200/400kVA models)
Serviceability
Integrated maintenance bypass
Input breaker
Batteries
Output characteristics
Standard
in line-and-match cabinets
Voltage
415
Certification
Regulation
1%
Safety
IEC 62040.1.1
Inverter
PWM with IGBT switching
< 2% (100% linear load); < 5% (standard nonlinear load)
0.7 lagging to 0.8 leading
EMC
EN50091.2
Voltage THD
Load power factor range
Battery
Battery types
VRLA, AGM,
Battery voltage
480 V
Temperature
compensation
Optional
Charging method
Advanced battery management technology
Communications
Software compatibility - Power Xpert
Communication cards - Two communication bays standard. Maximum of four
communication bays with the communication expansion option. The following
connectivity options can be installed at any time.
- ConnectUPS Web/SNMP/xHub, Modus card, Relay Interface Card (Use for
AS400s), Industrial Relay Card (5A@120V), Hot Sync CAN Bridge Card provides CAN
communications, isolated RS-485 port, Environmental Monitoring Probe (EMP)
www.eaton.com/powerquality 1300 UPS UPS
53
Intelligent Power Distribution
Maximise your available power
Utilise all your available power through Intelligent
Power monitoring
Ensure you have the power you need, where you need it
Combinations of IEC C13, C19 and local sockets
Manage your moves and changes in the data centre and redistribute
your power
Know what power is available for you to add servers or capacity,
or if you are reaching capacity
Maximum availability
Designed for the data centre environment and to fit in any industry
standard rack
Rugged Aluminium chassis, with multiple mounting options
Available in 0U Vertical, and 1U or 2U horizontal options
High quality components and state-of-the-art technology and circuitry
Managed ePDU
Basic ePDU
Managed ePDUs offer the data centre managers the maximum
functionality fully Intelligent Power distribution for complete
understanding and control, of Data Centre power distribution, including:
Designed for reliable and cost effective power distribution, Basic ePDUs
have the form factor and outlet choices to meet your needs.
Monitoring: highly accurate individual outlet, branch circuit, and full
ePDU monitoring for V, W, A and kWhrs. Also monitor temperature and
humidity in the rack via optional sensors
Switching: individual outlet, sequencing of outlets with delays or
cycling enables remote reboot of equipment
Control: Monitor and control remotely over Ethernet and via Advanced
LCD screen on the unit. Communication protocols include HTTP /
HTTPS, DHCP, SNMP v1 and v3, SNTP, SMTP, Telnet, IPv4 & IPv6
Manage your power consumption
Control your operating costs by monitoring and tracking consumption
from rack to branch, right down to the individual server
Easily identify physical branch sections and related breakers through
Colour-coded sections
Accurate V, W, A and kWhr measurement enables analysis
and tracking
Designed for the Data Centre: All ePDUs, including basic ePDUs,
are made of rugged aluminium or steel chassis and incorporate fully
shrouded circuit breakers and switches, they are designed to be highly
reliable, and designed to last.
Advanced Monitored ePDU
Advanced Monitored ePDUs give the data centre manager the detailed
information and understanding they need to efficiently and effectively
run their data centre
Monitoring: Highly accurate individual outlet monitoring, branch circuit
monitoring and the ePDU as a whole, for V, W, A and kWhrs. Also
monitor temperature and humidity in the rack via optional sensors
Control: Monitor and measure key properties and alerts remotely over
Ethernet or via Advanced LCD screen on the unit. Communication
protocols include HTTP / HTTPS, DHCP, SNMP v1 and v3, SNTP, SMTP,
Telnet, IPv4 & IPv6
Enables you to see what your servers are doing
Monitored ePDU
Complete control and understanding
Monitored ePDUs monitor the current draw to allow for provisioning
and load balancing of servers, and to ensure current draw is not
approaching breaker limits.
Control your power distribution and consumption
Build knowledge base of what is going on
Switch, sequence outlets and outlet groups as well as individually
monitor you have complete control
Switched ePDU
Switched ePDUs give control to the Data Centre manager be able to
remotely shut off or restart equipment, and ensure that it starts up in the
correct sequence with the correct delays.
Switching: on and off control of individual outlets, together with
cycling and sequencing of outlets, branch circuits and the ePDU
as a whole
Monitoring: Highly accurate monitoring of the ePDU as a whole for V,
W, A and kWhr. Also monitor temperature and humidity in the rack via
optional sensors
Monitoring: Monitor current on input and each branch circuit to
ensure accurate load balancing
Control: Monitor and measure remotely over Ethernet or via LED
interface on the unit
Transfer Switch
The STS source transfer switch is a simple and effective solution to
manage the redundancy provided by two independent power sources.
STS handles the automatic or manual transfer of your loads between
two independent power sources without interrupting the supply of
power (< 6 milliseconds). Either of the two sources may be designated
as the preferred source with the other becoming the alternate source.
In the event of a failure, transfer from one to the other is automatic
and instantaneous.
Control: Monitor over Ethernet or via Advanced LCD screen on the unit,
control via Ethernet. Communication protocols include HTTP / HTTPS,
DHCP, SNMP v1 and v3, SNTP, SMTP, Telnet, IPv4 & IPv6.
54
EATON CORPORATION UPS and Power Quality Products Catalogue
Airf low management and racks
Aisle containment
Industry studies indicate that an estimated 60% of the cool air
supplied to traditional data centres is wasted because it bypasses the
intended IT equipment and returns directly to the hot air intake of the
CRAC. Adopting a cold or hot aisle containment strategy increases
air efficiencies, allowing a significant reduction of cold air supply,
translating to longer hardware life and valuable energy savings.
Eatons solutions can be equally effective for both hot and cold aisles in
the data centre.
Rack Integrated System
Features and Benefits
End of Row Doors create more efficient cold aisles by blocking an
obvious cold-air escape route and entry for hot air re-circulation and air
mixing. This allows you to set a higher overall temperature within the
data centre thus saving energy and extending hardware life.
Variety of Door Models Choose from three styles of doors Singleswing, double-swing caf style and sliding doors
Eatons ceiling system is comprised of clear panels made from materials
with multiple ratings including UL94 V-0, ASTM E 84, FM4910 or
antistatic. These panels mount easily to the top of Paramount, Vantage
S2 and third-party enclosures. The ceiling system is modular and
scalable to accommodate differences in rack heights and row spacing.
It's self-supporting structure allows for easy rack changes within the
row. Fire-activated ceiling panels ensure quick row access for critical
fire suppression.
Rack Agnostic Flexible enough to install almost anywhere on any
manufacturers brand enclosure
Ease of Installation Field-installable, rack-integrated and freestanding
options available
Improve Efficiency and Predictability Increases cold air intake
efficiency, from the bottom of the enclosure to the top, within the
cold aisle
Minimise Air Re-mixing Cost-effectively minimise air mixing between
the hot and cold aisle while keeping the uniform cold air supply in front
of the servers for a consistent temperature top to bottom
Independent Containment System (ICS)
The culmination of Eaton containment strategies is its patent pending
Independent Containment System (ICS), a free-standing, scalable,
sustainable and vendor-neutral containment solution for high-density
computing environments.
Designed to provide maximum flexibility in all environments, the ICS,
assembled within the footprint of a standard aisle, is constructed with a
tubular steel frame. The frames structure is designed to be freestanding
and meets seismic NEBS Zone 4 standards.
Additionally, it accepts a variety of Eatons End of Row Doors including
caf style, swing and sliding models.
Features and Benefits
Scalable Design The ability to extend aisles with load growth makes
the ICS an ideal solution for co-location and other highly evolving data
centre. Design can support an overhead cable tray
Containment Integrity Vertical blanking panels ensure airflow
containment when racks are partially deployed within the row and are
easily removed in sections to allow quick installation of new IT racks
Rack Agnostic Ability to support virtually any brand of server
or network rack in any depth, height and size with on-demand
reconfiguration of the row
Shown above - Independent Containment System featuring
End Of Row, Cafe-style doors and vertical blanking panels to
accommodate third-party enclosures.
Cold/Hot Aisle Compatible Easily deployed as a cold aisle
containment solution with or without a down flow chimney system
Increased ROI Modular, building-block design offers complete
flexibility and room for growth increasing your initial Return on
Investment (ROI)
www.eaton.com/powerquality 1300 UPS UPS
55
Airf low management and racks
Rack containment
Eaton Heat Containment System (HCS)
Eaton's HCS is a simple, scalable and low cost solution to cool up to 25
kW or more per enclosure without the expense of adding supplemental
CRAC units to your data centre. This patented technology is available on
Eatons Paramount and Vantage S2 enclosure systems and can also be
field retrofitted to most manufacturers' enclosures. The HCS contains
and directs the heat exhaust of your IT equipment through the chimney
that is attached to the top rear of the enclosure. The hot air is then
ducted to your existing CRAC units through a plenum ceiling or high
air returns.
Active Airflow Manager
HCS for third-party racks
Converting existing enclosures to the HCS allows you to eliminate the
incremental capital expense associated with having to add more CRAC
units or other supplemental cooling.
Features and benefits:
Implement heat containment operations by building up from existing
enclosures without having to re-route or disconnect cables and power
By isolating the hot exhaust air from the cold supply air, you can load
over 25 kW of equipment in an enclosure
Requires no additional air conditioners or other space consuming
supplemental equipment at the perimeter of the data centre, in-row
or overhead
Eliminates chaos airflow results in a more predictable operating
environment, allowing you to drive efficient energy use and create a
reliable infrastructure for moves, additions and changes
Eatons HCS pressure based system with active airflow, when combined
with best practices, improves performance metrics considerably.
Allocating the correct amount of airflow at known intake locations is
the key to reducing energy consumption while increasing equipment
performance. Best practices such as blanking panels, proper perforated
tile placement and the reduction of bypass airflow must be employed to
ensure desired results.
Eatons Paramount enclosure
with integrated HCS.
Features and benefits:
SNMP managed device with user-friendly Web interface
Controller continuously monitors pressure differentials to ensure that
air entering the enclosure and server is properly removed
Local LEDs indicate fan status including fan fail and over temperature
Manage up to 64 peer active Airflow Managers via Ethernet
Two integrated temperature sensors with e-mail alert capabilities
Redundant power input, C13 plug type is required for each input, 90-240
Vac supplied by enclosure PDU(s)
Controller is RoHS compliant
Utilisation as your capacity demands grow
Dramatically increasing the reliability of the data centre increasing
their efficiency by operating at a higher Delta T (DT) centre, freeing up
stranded assets and lowering operational costs locations and it is also
field-installable on third-party enclosures
The HCS allows for your
existing cable management
without the interruption of
re-routing or disconnecting
cables and power. Shown
here on Eaton's Paramount
Enclosure System.
Optional fans (2)
Chimney
Tool-less fan access door
Chimney base
56
EATON CORPORATION UPS and Power Quality Products Catalogue
Airf low management and racks
Enterprise-class racks
Eaton Paramount enclosure system
Our premier enclosure platform, Paramount not only supports an
industry leading 1,000 kilograms of equipment in a fully welded frame,
but it is also designed to adapt to the ever-changing requirements of
the data centre through a scalable and modular approach. Speed of
deployment is essential to any company when considering time to
market. Paramounts modularity and building block design ensures
quick reconfigurations and minimises downtime, protecting your
initial investment.
Features and benefits:
Rack accessories
Blanking panels
Blanking panels provide a quick, easy and cost-effective solution to
optimise air circulation within an enclosure while maintaining high
aesthetics. Eaton offers blanking panels in a variety of styles including
tool-less, mechanically fastened, clear and with cable pass through
options in steel as well as plastic. The width meets EIA-310-D standards
and they come in various heights (depending on style). Most panels are
bulk packed in quantities of 10 and 100.
Superior airflow control and management
Flexible platform allows for ever-changing
requirements, protecting your initial investment
Industry leading weight capacity of up to 1,000
kilograms handles even the heaviest server
equipment
Guaranteed compatibility with TIA/EIA-310-D*
standard sized equipment
Eaton's patented Heat Containment System
(HCS) cools up to 25 kW or more per enclosure,
without the expense of adding supplemental
CRAC units to your data centre
Features and benefits:
Significantly reduces re-circulation of hot exhaust air to the
equipment inlet
Adds to the overall aesthetics of the data centre
1U, 2U, 3U, 4U, 5U, 6U, 7U, 8U and 20U (depending on style)
EIA-310-D compliant for 19" equipment
Color: black steel, black plastic, clear plastic
Available in tool-less, mechanically fastened, clear and cable
pass-through styles
Full complement of accessories to handle non-rackmount devices
Industry leading cable access and management
Eaton E Series enclosures
Eatons E Series enclosures provide high quality and advanced features
at an affordable price.
Features and benefits:
Lightweight but sturdy
Stylish contoured front door provides
2,649.22cm2 total open area. Exceeds major IT
equipment air flow requirements
Vendor neutral, compatible with all 19
standard IT equipment
Depth adjustable 19 vertical mounting rails
Solid side panel
A solid side panel kit (qty. 2) is available to further
enclose your rack where end of row or single rack
aesthetics is necessary.
Cable rings
Flexible mounting to multiple points for vertical
cable management.
Heavy-duty fixed shelf
Supports non-rackmounted equipment. Four
point mounting and 400 pound weight capacity.
U numbers printed on rails
Quick release and field reversible doors
Overall height on casters, just under 2 metres,
fits through standard doorway
Two piece side panels provides easy access
to interior
Grounding kit
Comply with National Electric Code (NEC) Article
250 Grounding.
Available in flatpack or fully assembled cabinet
Quick assembly time, approximately 30 minutes Specifications:
Overall dimensions: 600W or 800W x 1000D x 1950H
Useable height: 42U
Load rated to 1,000 kg static
Standard: EIA-310D, IEC-60297-2
Material: high-grade cold and hot rolled steel/all materials
RoHS compliant
Finishing: 5 stage iron phosphate pre-treatment followed by tough
scratch resistant powder coat paint
www.eaton.com/powerquality 1300 UPS UPS
57
Intelligent Power Software Suite
Eatons Intelligent
Power Software Suite
Incorporates two important applications for ensuring quality power
and uptime: monitoring and management of power devices across
the network and automatic, graceful shutdown when faced with an
extended power outage.
Use each software independently or as a powerful combination.
Together with your UPS, they provide end-to-end power management for
maximum uptime and data integrity.
I ntelligent Power Manager: software for extensive monitoring
and management.
I ntelligent Power Protector: shutdown software for extended
power outages.
Intelligent Power Manager supervisory software lets you monitor and
manage multiple power and environmental devices across the network
from a single interface, giving you up-to-the-minute information on the
status of power in your network. It also works seamlessly with VMwares
vCenter Server and vMotion as well as Microsofts SCVMM and
Live Migration.
Intelligent Power Protector protection software provides graceful,
automatic shutdown of network devices during a prolonged power
disruption, preventing data loss and saving work-in-progress. As part
of Eatons power network management system, these two applications
work together to deliver comprehensive power management and
protection.
Monitor and manage multiple power and environmental devices from
any Internet browser or your vCenter dashboard
Helps you avoid data loss by gracefully shutting down computers and
virtual machines/servers powered by an Eaton UPS during an extended
power outage
Auto discovery provides fast installation by automatically detecting
devices on the network
Easy-to-use interface from any PC with a Web browser
Mass-upgrading of firmware capability reduces network management
card setup and maintenance time
Acquires UPS information through local or network communication and
can be easily deployed on many computers
Shutdown agent management enables safe shut down of servers
Can be remotely managed, configured and updated with Eatons
Intelligent Power Manager
Multiple password-protected access levels and support for secure
communications
All the functionality of an enterprise-class monitoring solution for free
or at a fraction of the cost
Can communicate with the protected device directly (via USB) or
through the network (via Web/SNMP card)
Support for up to 10 devices included at no charge; additional capacity
may be purchased
Benefits for Virtualised Environments
Intelligent Power Managers Integration with vCenter helps data centre managers reduce infrastructure and operating costs while increasing
productivity and operational responsiveness Intelligent Power Manager triggers vcenters vMotion and SCVMMs Live Migration applications to
transparently move virtual machines from a server affected by a power interruption to an available server on the network, ensuring data integrity and
zero downtime.
58
EATON CORPORATION UPS and Power Quality Products Catalogue
Options to Manage and Monitor Your UPS
Network Management Cards
ConnectUPS Web/SNMP card
Relay Cards
Network Card-MS
Network Card-MS and ConnectUPS Web/SNMP cards are a complete
UPS monitoring, control and shutdown solution in a networked IT
environment. In case of alert the Web/SNMP card can notify users and
administrators through e-mail and SNMP traps. In case of a prolonged
power failure the protected computer systems can be shut down in a
graceful manner with Intelligent Power software. The unique
three-port switching hub on the X-Slot model provides additional
network connections.
Relay/AS400 card
Relay Card-MS and X-Slot Relay cards are an easy connection to
IBM AS/400 series computers as well as industrial and building
management systems.
Other Devices
Industrial Network Cards
Environmental Monitoring Probe
ModBus card
Network & Modbus Card-MS and X-Slot Modbus cards connect the UPS
to industrial and building management systems using ModBus
RTU protocol.
Power Xpert Cards
Power Xpert Gateway Card"
Power Xpert Gateway cards provide Web-enabled, real-time monitoring
of Eaton UPSs and PDUs through standard onboard Web pages, Power
Xpert Software or third-party software. As an integral part of the Power
Xpert Architecture, the cards provide a central point to connect UPS and
PDUs to an Ethernet network via an X-Slot communication bay.
Environmental Monitoring Probe (EMP) adds temperature, humidity
and two contact closure monitoring capability to Network Management
Cards and Power Xpert Cards. It is especially well suited for monitoring
rack temperature and door status. Operating system shutdown can be
triggered if user defined thresholds are exceeded or contact closure
status changes.
ViewUPS-X
ViewUPS-X remote display is an LCD panel that lets users view the
status of the UPS from as far as 100 m. ViewUPS-X has also four status
LEDs and an alarm sound. The display is bundled with a dedicated X-Slot
card that also powers the display through the communication cable.
In addition to the remote display connection the card has also a
SELV isolated relay port for connection to monitoring systems and
AS/400 computers.
www.eaton.com/powerquality 1300 UPS UPS
59
Eaton's Power Xpert Architecture
Manage Power as a
Strategic Asset
A simple, Web-based
interface helps you to:
Today, the IT infrastructure is viewedand managedas a strategic
business asset. Clearly, the quality of the electrical power that flows
through facilities, data centres and server rooms should be a factor
when IT managers measure infrastructure performance. Yet, invisible
and fleeting power disturbances can be silent killersoften going
unmonitored and unnoticed.
Understand energy usage patterns and baselines
With Eatons Power Xpert Architecturethe backbone of our
PowerChain Management solutionsyou gain unprecedented visibility
into the entire power system. A framework to view your entire power
system, Power Xpert Architecture encompasses conditioned power in
the data centre as well as unconditioned power coming into the facility.
Through hardware, software and communication elements, the
architecture unites diverse power components across your enterprise
into a single viewold and new PDUs, batteries and other critical
equipment from multiple manufacturers. So you can monitor, control
and manage the power system more effectively and efficiently as you
correlate events across the power system, drill into details for quick
diagnosis and use tools to determine appropriate actions.
Web Browsers
view Power
Xpert Software
& components
Reduce peak loads, identify high energy users and realise
energy savings
Find the real causes of issues, including power event ghosts, sags,
swells and transients
Analyse event severity according to IT standards
See your power quality at a glance
Leverage Power Xpert Architecture to establish a unified management
approach for your enterprise. The solution is based on open standards
so that devices can communicate. It synchronises equipment clocks
through a network time server so you can accurately correlate events at
different points in the system.
Power Xpert ArchitectureIts one of Eatons powerful innovations in
facility monitoring and management. For additional information about
Power Xpert Architecture and to download the product data sheets,
visit: www.eaton.com/powerxpert.
Software users
view, monitor, and
manage information
about their power chain.
PowerXpert
Dashboards
view the status
of your power
chain at a
glance.
PowerXpert Server
Core Software to
help you model,
monitor and manage
your power chain.
60
EATON CORPORATION UPS and Power Quality Products Catalogue
Power Management
Power and Energy
Meters
Power Xpert Meter 4000/6000/8000
Eatons Power Xpert Meter series represents world-class power
monitoring that reduces day-to-day operating costs and helps avoid
costly business interruptions. The meters combine state-of-the-art
technology with an embedded Web server, advanced power diagnostics,
data trending and performance benchmarking, along with a twist-n-click
LCD for simplicity and ease of use.
IQ 250/260 series
Metering products
The IQ 250 and IQ 260 electronic meters provide capabilities you
wouldnt normally expect in an affordable, compact metersuch as
fast sampling rate and accurate metering for a full range of power
attributes. The meter can be configured either from the easy-to-read
display or remotely (accessible via a Power Xpert Gateway) via included
configuration software. In addition, built-in slots allow for upgrades to
input/output option cards.
IQ 250/260 Features
Comprehensive metering
High-end accuracy
Large, easy-to-read display
Features and Benefits
Local or remote configuration
Free download of
power Xpert Meter
Profiler to trend
and predict energy
usage
Industry-standard
communication protocols
(Modbus)
Mix-and-match input/output
options
Embedded Web
Server
Field-upgradeable
Automatic power
quality analysis
and trigger setting
with built-in ITIC
performance curve
IQ 100 series
Comprehensive
power, energy and demand measurements for 138 standard data points
logged
At-a-glance view of power quality analysis with patented Power Quality
Index gauge
Industry-standard communication protocols, to support a multitude
of configurations and third-party software: HTTP, FTP, Modbus RTU,
Modbus TCP, SNMP, SMTP, NTP, COMTRADE
High storage capacity
Metering products
Providing the first line of defense against costly power problems, Eatons
IQ 100 electronic power meters can perform the work of an entire wall
of legacy metering equipment utilising todays technology. Eatons IQ 100
meters use 24-bit AD converters that sample at more than 400 samples
per cycle and meet ANSI C12.20 standards for accuracy of 0.5 percent.
With such high-performance measurement capability, these meters
can be confidently used for primary revenue metering and submetering
applications.
ANSI C12.20 accuracy
Applications
CE certified
Utility and commercial metering
Power Xpert Meter 2000 series
Substations, industrial facilities,
power generation sites and
campuses
Compact Power Quality Metering products
Submetering
The meters combine state-of-the-art technology with waveform viewing,
data trending and performance benchmarking. The embedded Web
server enables users to surf to the meter over the Internet via a standard
Web browser. This platform offers adaptability such as field-upgradeable
firmware and optional digital inputs/outputs and analog outputs.
Load studies and voltage
recording
Analog meter replacement
Identify power quality problems
to help:
Protect motors from damage
Preserve the integrity of
processes and batches
Prevent blown capacitor
bank fuses
Protect transformers and
conductors from overheating
www.eaton.com/powerquality 1300 UPS UPS
61
Power Management
Power Xpert Software
and Foreseer Services
Power Xpert Software
Power Xpert Software enables you to manage the complexities of
large system deployments, from one desktop, on one screen. Web
enabled hardware devices are fine in limited numbers, but as the
number of components grows or becomes more complex, Power
Xpert Software is the logical choice for the required trending, analysis
and alarming systems.
Power Xpert Software is Web-enabled, open and time synchronised.
Using only a browser, you can access the software from anywhere
your network can reach, including remotely. Designed to communicate
graphically with the broad range of Eaton and non-Eaton devices, Power
Xpert Software uses industry-standard protocols. The software is
available in two editions: Professional and Enterprise.
Power Xpert Software Professional Edition
Geared towards end users, with built in support for Eaton power
distribution products such as switchgear, UPSs, breakers, PDUs, RPPs,
meters, relays, VFDs and MCCs among others
Standard reports include: Energy Summary Report, Energy Cost
Allocation Report, Power Quality Report, Branch Circuit Report, Capacity
Summary Report, Event
Summary Report, Joint
Commission (JCAHO)
Report.
Highlighted features
Helps quality for LEED
credits
Reporting hierarchies
organise device data
Microsoft Excel
integration for further
analysis
Web browser access
Connect to
multiple databases
simultaneously
Foreseer Services
Foreseer Services provide vendor independent, power and energy
infrastructure integration solutions that help companies reduce energy
consumption and unplanned downtime due to the failure of critical
power, environmental, safety or security systems.
Eaton products connect with the software directly via an Ethernet
connection, while legacy devices use a Power Xpert Gateway to Webenable their communications
Features and Benefits
A subset of third-party meters and devices are supported as standard
via the gateway connection
Offered in three main categories: Foreseer Software Services,
Foreseer Project Management Services and Foreseer Engineering
Services.
Power Xpert Software Enterprise Edition
Geared towards advanced power users, system integrators and
enterprises with heterogeneous device spectrum and system
developers who can take advantage of the included SNMP and
Modbus integration development utilities
Extensive support for third-party devices via standard SNMP and
Modbus TCP protocols
Large variety of ready made third-party drop in drivers
62
Power Xpert Reporting
Turns data into Distributed, scalable architecture is tailored to meet
organisational needs.
High performance trend analysis and forecasting tools assess
equipment performance through cause analysis, impact analysis,
capacity planning, preventative maintenance assessments and
trending.
Extensive, multi-vendor, device-driven library interfaces monitor a
multitude of different device types
Customisable, graphic user interface (GUI) depicts any company or
organisational topology in the initial design.
Web browser access and remote notification enables easy system
access without the need for additional client seat licenses.
EATON CORPORATION UPS and Power Quality Products Catalogue
Power Management
Energy Management
System Upgrade Kit
Monitoring: 42 circuits (one panel) or 84 circuits (two panels)
Rating:
208/120V, 380/220V, 400/230V, 415/240V
Configuration: Wall-mounted, standalone unit
Features
Millions of dollars a year are invested in power protection systems such
as UPSs and generators, but problems can still occur at the branch
circuit level due to improper loading or inadequate monitoring. You might
not be able to see trouble coming until a circuit breaker trips, and thats
too late. Systems go down. Valuable data is lost, and business comes to
a standstill. It can take hours to recover.
Monitors power conditions on individual breakers, panels or at the
equipment levelthree tiers of visibility within one unit
Provides remote monitoring via the Power Xpert Gateway Card,
The EMS continuously measures the current on all breaker levels and
warns you of impending trouble, so you can take proactive steps. Armed
with these insights, data centre and facilities managers can more
effectively balance loads, prevent overload conditions, plan for future
capacity needs and, where applicable, allocate energy cost among
internal departments.
Extends the branch circuit monitoring capabilities of the Eaton
Energy Management System (EMS) to legacy and third-party power
distribution equipment
which links Eaton and non-Eaton equipment to the local area network
or the Internet
Tracks and records more energy parameters and provides more
standard features than alternative branch circuit monitoring systems
from other vendors
Delivers real-time and historical information for precision analysis,
troubleshooting, power management, billing and energy planning
Streamlines and unifies the management of diverse, multi-vendor
power distribution systems
Extending the reach of the Energy Management System
The EMS has always integrated with Eatons latest generation of power
distribution panelboards, power distribution units and remote power
panels. Now a new Eaton Energy Management System Upgrade Kit
is available to extend these branch circuit monitoring capabilities to
existing equipment, from Eaton or others. With the EMS Upgrade Kit,
you bring the entire power distribution system under the support of the
EMS. Even if you have a mix of older equipment from other vendors, you
get the insights to effectively manage the edge of the power distribution
system. You will be able to track and analyse:
Time-stamped metering, alarm, event and statistical information
Peak loads, along with current, power and frequency minimums
and maximums
Voltage and power, monitored all the way down to the branch
breaker level
Power quality metrics, such as total harmonic distortion (THD) and
power factor (PF)
Load profiling to make the best decisions for energy planning This
information is shown for individual circuits, each panelboard and at
the equipment levelequipment such as a power distribution unit
(PDU) or remote power panel (RPP)to provide visibility at all levels in
one system.
www.eaton.com/powerquality 1300 UPS UPS
63
Surge Protection Devices
Surge Protection Equipment Overview
In nanoseconds a power surge can do major damage to sensitive
equipment and data. It can come from anywhere, and like a bullet, you
only know it has been by the destruction left behind.
1. Eaton PPFi
2. Eaton MSDi
6. Eaton SPD50NGi
10. Eaton POD & POD+
3. Eaton SPDi
7. Eaton ESFi
4. Eaton SPDV60/T60
8. Eaton DSFi
11. Eaton SSFi
5. Eaton Quickmov
9. Eaton CSFi
12. Eaton SF8RM
1. Series Power and Noise Filter with Shunt Surge
Diverter 3 Phase, 100-800A, 80-240kA
6. Neutral-Earth or Earth-Earth
Equipotential Clamp 50kA
10. Surge Powerboard for IT and AV
applications, 10A, 220-250V, 60kA
2. Shunt Surge Diverter, 3 Phase 200kA
7. Series filter with Shunt Surge Diverter
Class II/Cat C & B, 1 & 3 Phase 50-80A,
100kA Series Surge Filters
11. Portable Surge Filter, 1 Phase 10A and
15A, 25kA Primary
3. Shunt Surge Diverter, 1 and 3 Phase, 40kA and 100kA
4. Shunt Surge Diverter, 1 Pole 60kA
5. Intergrated Surge Protection Device
(Inernally HRC Fused) 1 Pole 60kA
64
That's why surge protection is so critical. And why Eaton builds so much
quality into our full line of surge protection products. Eaton has a world
beating reputation for Power Quality and a full range of surge protection
solutions, covering every eventuality.
8. Series Filter with Shunt Surge
Diverter, 1 Phase 5-32A, 40kA Primary
9. Series Filter with Shunt Surge
Diverter, 1 Phase 3-25A, 25kA Primary
EATON CORPORATION UPS and Power Quality Products Catalogue
12. Single Phase Rack
Mounted Filter /PDU
Eaton POD & POD+
The POD is manufactured from the highest quality materials and is
ergonomically and aesthetically designed to suit office and home
installations. Rest easy with a five year full replacement warranty and
a $100,000 load protection guarantee* (Australia and New Zealand).
Series Power Filter and
Shunt Surge Diverter
*Conditions apply
Key Features
POD 6 Outlet or POD+ 8 Outlet models
10A, 220-250V, 60kA
60,000 Amp surge protection
The Eaton POD protects your precious Computer System, Home
Entertainment System and other valuable electronic equipment
from surges, spikes and noise caused by lightning and other power
disturbances. An ideal device for Category A locations.
Highest quality power sockets with extra wide spacing
Visual indication of Power and Surge Protection status
1.8 metre power cord with insulated pins
Resettable circuit breaker
Its series power filter provides superior protection against surges and
spikes, with the additional benefit of protecting against line noise that
may affect sensitive equipment. With a surge rating of 60kA, the POD
out-performs and outlasts many other products that provide shuntonly protection. The POD not only protects your power circuits, but
also protects against back door surges that can enter your systems
telephone lines, aerials or network cables.
Power Connections
Power On/Off switch
Data, Video/Aerial and Phone surge protection on POD
Data, Video/Aerial, Cable TV and Phone surge protection on POD+
Network cable, telephone cable and Coax cable supplied
Wall mountable to save valuable floor space
Phone/Fax Connections (RJ11)
Input Voltage:
220-250VAC
Nominal Line Impedance:
600 Ohms
Frequency:
50/60Hz
Maximum Line Voltage:
275Vrms
No. of Outlets:
POD = 6 x 10A
POD+ = 8 x 10A
Clamping Voltage (Line to Line):
430V (270Vac RMS)
Maximum Continuous Load:
10 Amps total
Clamping Voltage (Line to Earth):
600V (375Vac RMS)
Current Limiting:
Resettable Circuit Breaker
Response Time:
500ns nominal
Clamping Voltage (Line to Neutral):
470V (295Vac RMS)
Maximum Surge current:
Peak let-through voltage (3kA L-L):
20,000 Amps
1000V
Clamping Voltage (Neutral to Earth):
680V (420Vac RMS)
Aggregate energy absorption:
300 joules
Response Time:
5nS Nominal
Video/Aerial connections
Aggregate Surge Current:
60,000 Amps
Connections
POD: Video Connector
POD+: Video Connector & F Type Screw
Connector
Maximum surge current (one pulse L-N):
40,000 Amps
Nominal line impedance:
75 Ohms
Maximum surge current (one pulse L-E):
10,000 Amps
Signal loss:
Approx. 3dB@500MHz
Maximum surge current (one pulse N-E):
10,000 Amps
Clamping Voltage:
600V (375Vac RMS)
Aggregate Energy Absorption:
1470 Joules
Maximum surge current:
20,000 Amps
Attenuation at full load:
>40dB @ 1MHz
Aggregate energy absorption:
200 joules
Lines Protected:
1/2, 3/6
(long x wide x high mm)
POD: 338 x 130 x 42
POD+: 383 x 130 x 42
Clamping Voltage (Line to Line):
<20V
Weight
POD: 0.8 kg, POD+: 1.0 kg
Clamping Voltage (Line to Earth):
600V (375Vac RMS)
Power Cord
1.8 metres length
Surge current - Amps (10/1000us):
20 Amps (2ms) /40
Network Connections (RJ45)
Dimensions
www.eaton.com/powerquality 1300 UPS UPS
65
Power Conditioners
Sola Power Conditioners
Eaton's Sola ferroresonant products are proven technology. In 1938,
Sola was awarded the first patent for ferroresonant power conditioners:
the constant voltage transformer. Since then, our technology has
remained at the forefront of ferroresonant power conditioning.
Today, Eaton's Sola ferroresonant power conditioners supply sinewave
output, which is especially important for computer applications.
Whether you purchase a model 200, 210 or 26 voltage regulator, you can
count on an average of 25 years service from your unit.
Every ferroresonant power conditioner is manufactured to exacting
specifications and is subject to rigorous quality control.
The ferroresonant power conditioners protect equipment from all power
problems, other than the complete loss of power. They excel at tightly
regulating the voltage, providing superior noise attenuation and are
ruggedly designed to withstand the harshest electrical environments.
Possessing no moving parts, ferroresonant power conditioners are
virtually maintenance free.
What is Ferroresonance?
Simply put, ferroresonance is the property of a transformer design in
which the transformer contains two (2) separate magnetic paths with
limited coupling between them. The output contains a parallel resonant
tank circuit and draws power from the primary to replace the power
delivered to the load.
Note that "resonance" in ferroresonance is similar to that in linear
circuits with series or parallel inductors and capacitors, where the
impedance peaks at a particular frequency. In a non linear circuit,
such as a ferroresonant transformer, "resonance" is used to reduce
the changes in supply voltage and provide more constant voltage to
the load.
A magnetic device is non linear. Its reluctance changes abruptly above
a certain magnetic flux density. At this point, the magnetic device is
defined as being in saturation.
The design of the ferroresonant transformer allows one magnetic path
to be in saturation, while the other is not. As a result, further change in
the primary voltage will not translate into changes in the saturated, or
secondary voltage, and voltage regulation results.
Typical Model 200 or 210 Performance
Features and Benefits
Superior Low Line Performance
Specified performance is maintained for all loads 0 - 100% of nominal
rating
Switchmode Computer Load Compatibility
Able to support typical computer loads when input supply mains
voltage is 50% below nominal
240 Volt, 230 Volt or 220 Volt Models
Separate models to suit different nominal supplies or particular nominal
output voltage requirements
200% Overload Rated
Suitable for use with computer start up overloads. Units are output
short circuit proof
On Site Configuration
7.5 to 18kVA units can be site configured as Single Phase or Three
Phase operation, if required
Selectable Voltages
Hardwired 26 Series units have selectable input and output voltages
5 Year Warranty
Exceptional MTBF (Mean Time Between Failure), an optimum
combination of performance to cost effective power conditioning
66
EATON CORPORATION UPS and Power Quality Products Catalogue
500VA to 2500VA Portable Power Conditioners
Sola 200/210
Designed and manufactured in Australia, the Sola 200/210 portable
power conditioner provides smooth stepless control of output voltage to
your computer or electronic system, whilst attenuating harmful impulses,
surges and other power line disturbances.
The Sola 200/210 incorporates improved surge withstand capabilities,
as specified by ANSI/IEEE C62.41-1980 and is covered by the SECV
Certificate of Suitability Number CS84292V.
Built to protect
Programmable logical controls (PLC)
Photographic equipment
Remote computer peripherals
Copiers and laser printers
Process control equipment
CNC machinery
Entire installations
Specifications
Ordering details
Input
240 Volt In/Out
Voltage:
220 or 240 Volt AC
Frequency:
50 Hz
Input Voltage Range:
+ 10%, -20% (40%)
Protection:
ANSI/IEEE C62.41-1980 A and B waveforms
suppressed to safe levels.
Output
Nominal Voltage:
220 or 240 Volt AC
Frequency:
50 Hz
Voltage Regulation:
3% for +10%, -20% input. +5%, -8% for 40%
input.
Control:
AC on/off switch
Power Efficiency:
90%
Response/Correction
Time:
Return to regulation envelope within 30 msec.
Dynamic Response:
Continuous and smooth correction for input
voltage fluctuations.
Overloads
200% of rated load for 10 seconds without
damage. 500% of rated load for 10 msec.
Rated
Output
VA
Part Number
Current
AMPS
(Cont.)
Output
Receptacles
Weight
(kg)
500
210-26-650-00
2.08
23
1000
210-26-710-00
4.16
36
2000
210-26-720-00
8.33
55
2500
210-26-725-00*
10.41
66
220 Volt In/Out Hardwired Units
Rated
Output VA
Part
Number
Current
AMPS (Cont.)
Weight (kg)
Enclosure
Size (Note 3)
500
200-44-650
2.27
23
1000
200-44-710
4.55
36
2000
200-44-720
9.09
55
2500
200-44-725
11.36
66
Notes:
1.
240 Volt Hardwired options available to order
Electrical Noise Attenuation
2.
Special voltage configurations available to order
Transverse Mode:
3.
Enclosure sizes (mm) Size 3: 195 (H) x 210 (W) x 328 (D)
60 dB typical, (80 dB max.) 4kHz to 20 MHz
Common Mode:
120 dB typical, (140 dB max.) 2kHz to 1 MHz
Output Harmonic
Distortion
Less than 3% THD on linear loads.
No greater than 5% on typical computer loads.
Enclosure
Size (Note
3)
Size 4: 252 (H) x 280 (W) x 421 (D)
4. * Input lead fitted with 15 Amp plug top (all other units fitted with 10 Amp
plug tops)
5. Specific input leads and output sockets can be fitted to order
Environmental
Operating Ambient:
-20C to +50C
Relative Humidity:
0 to 95% non-condensing
Ventilation:
Natural Convection Cooled
Status Indication
Power On:
Amber lamp
Overload Protection
Output short circuit protection
Warranty
5 years
www.eaton.com/powerquality 1300 UPS UPS
67
3kVA to 22kVA Power Conditioners
Sola 200
The extension of Sola ferroresonant power conditioners continues
through to 22kVA. These units are mostly suited to hardwired, fixed
installation applications for providing smooth stepless control of the
output voltage, attenuation of harmful impulses or surges and other
power line disturbances. Sola 200 power conditioners are ideally
suited to provide protection in computer rooms, regulation for scientific
instrumentation, plus protection and regulated power to sophisticated
computer based factory process equipment. To simplify installation, all
units are free standing and fitted with castors (excluding 22kVA) and
jacking feet. Connections are provided at the rear via a base plate cable
entry to an isolation switch.
The flexibility of Sola 200 power conditioners is increased on units
between 7.5kVA and 18kVA. These units can be field configured for
single phase or three phase operation. Sola 200 power conditioners (3 to
22kVA) incorporate approved surge withstand capabilities, as required
by ANSI/IEEE C62.41-1980.
Specifications
Input
Voltage:
2 20, 230 or 240 Volt AC (Refer Ordering
Details for configuration options)
Frequency:
50 Hz
Input Voltage Range:
+ 10%, -20% (40%)
Protection:
ANSI/IEEE C62.41-1980 A and B
waveforms suppressed to safe levels.
Built to protect: Remote computer peripherals, copiers and laser
printers, process control equipment, CNC machinery, programmable
logical controls (PLC), photographic equipment and entire installations.
Ordering details
Configuration
Weight
(kg)
Enclosure
Size (Note 5)
Nominal Voltage:
220 or 240 Volt AC
Frequency:
50 Hz
200-26-730
1 Phase only
100
Voltage Regulation:
3% for +10%, -20% input. +5%, -8% for
40% input.
200-26-730-00**
1 Phase only
100
Control:
AC on/off switch
200-26-750
1 Phase only
155
200-26-750-HO***
1 Phase only
155
7.5
200-26-775****
1 or 3 Phase
215
200-26-790****
1 or 3 Phase
270
200-26-812M****
1 or 3 Phase
360
Output
Power Efficiency: 90%
Response/Correction
Time:
Return to regulation envelope within 30
msec.
Dynamic Response:
Continuous and smooth correction for
input voltage fluctuations.
12
15
200-26-815****
1 or 3 Phase
420
Overloads
2 00% of rated load for 10 seconds without
damage. 500% of rated load for 10 msec.
18
200-26-818****
1 or 3 Phase
520
22.5
200-46-822****
3 Phase only
595
Electrical Noise Attenuation
Transverse Mode:
60 dB typical, (80 dB max.) 4kHz to 20 MHz
Common Mode:
1 20 dB typical, (140 dB max.) 2kHz to 1
MHz
Output Harmonic
Less than 3% THD on linear loads.
Distortion
o greater than 5% on typical computer
N
loads.
Notes:
Environmental
Operating Ambient:
-20C to +50C
Relative Humidity:
0 to 95% non-condensing
Ventilation:
Natural Convection Cooled
1. * For units with nominal Ph-N voltage of 220V specify 44 (as in 200-44-730)
for 3-18kVA units and 24 (as in 200-24-822) for 22.5kVA model. For units
with nominal Ph-N voltage of 230V specify 25 for 3-18kVA units and 35 for
22.5kVA.
2. ** Units fitted with WIP 15 plug and 4 x 10/15 Amp screw sockets
3. *** Units fitted with input terminal block and 4 x 10/15 amp screw sockets
4. To avoid nuisance tripping of input circuit breakers, we recommend the use
of "D" curve or motor start type circuit breakers. Current rating should be at
least one size larger than input current stated on unit
data plate. See manual or consult your sales representative for
further details.
5. Enclosure Sizes (mm): Size 1: 600 (H) x 400 (W) x 440 (D)
Status Indication
68
Part Number
Rated
Output
kVA
Power On:
Amber lamp
Overload Protection
Output short circuit protection
Warranty
5 years
EATON CORPORATION UPS and Power Quality Products Catalogue
Size 2: 995 (H) x 525 (W) x 550 (D)
Size 3: 990 (H) x 800 (W) x 550 (D)
Size 4: 1236 (H) x 800 (W) x 550 (D)
6. **** 3 Phase loads to be star connected only. Power Conditioners NOT to be
used for Delta loads.
Multi-Voltage, Hardwired Power Conditioners for Industrial Applications
Multi-Voltage,
Hardwired Power Conditioners for Industrial Applications
Sola
26 Multivolt
Frequently, power transformers are incorporated with process
equipment to provide specific voltages for sensitive equipment.
Unfortunately, outside interferences will vary the output from these
transformers, causing the sensitive equipment to malfunction or
fail. The Sola 26 range of power conditioners provide an immediate
answer to this inconvenience, by suppressing and isolating power
line interference and regulating the output voltage to 5%. These
hardwired power conditioners provide the unique feature of selectable
input tap for greater versatility and output voltage taps are also
provided. These features make the Sola 26 power conditioner the ideal
choice for a regulated power supply where a three phase source is
provided without a neutral line.
The Sola 26 power conditioner provides superior noise rejection,
exceeding 120 dB common mode and 60 dB transverse mode noise
rejection. By nature of design, this product is a true, ultra isolation
device. The Sola 26 is available from 500VA through to 15kVA as a panel
mounting, hardwired unit.
specifications
Built to protect
Input
Voltage:
500-5000VA Models: Field selectable
110/120V or 220/240 or 380/415V
7 .5-15kVA Models: Field selectable
220/240V or 380/415V
Frequency:
50 Hz
Remote computer peripherals
Copiers and laser printers
Process control equipment
CNC machinery
Programmable logical controls (PLC)
Photographic equipment
Output
Entire installations
Voltage:
F ield Selectable - 110/120/220/240
Volts AC
Voltage Regulation:
5% for an input line variation of
15%. + 5%, -8% for 40% input.
Output Harmonic Distortion
Less than 3% THD on linear loads. No
greater than 5% on typical computer
loads.
Efficiency
85% at full load.
Dropout
No loss of output for line loss of 3
msec.
Electrical noise rejection
Ordering details
Rated
Output
VA
Part Number
Height
(H) (mm)
Width
(W)
(mm)
Length
(L)
(mm)
Weight
(kg)
500
2605-0500M
162
200
362
18
1000
2605-1000M
170
200
460
28
2000
2605-2000M
244
288
467
51
3000
2605-3000M
244
288
501
73
Transverse Mode:
> 60 dB
5000
2605-5000M
244
288
736
110
Common Mode:
> 120 dB
*10000
2605-10kM
244
630
736
221
Operating temperature
-20C to +50C
*15000
2605-15kM
244
987
736
350
Warranty
5 years
Typical Single Module Arrangement
www.eaton.com/powerquality 1300 UPS UPS
69
Protecting your investment
Service
We at Eaton do our best to make it as simple as
possible for you to pick the right UPS equipment
to match your power protection needs.
In the same vein, we have also compiled four
distinct service packages to match different types
of maintenance needs and budgets. Whichever
package you choose, you can rest assured it
delivers power security and reliability that will
keep your core business running.
Service Plans Summary
Service Features Included in Service plans
Powertrust
Preferred
Powertrust
Proactive
Powertrust
Preventative
Maintenance
Onsite corrective maintenance (5x8)
Onsite corrective maintenance (7x24)
Repair service: Parts and labour for electronics
Repair Service: Parts and labour for batteries
2, 4, 8 hour response time option
Preventative maintenance visit (5x8)
One per year^
Preventative maintenance visit (7x24)
One per year
One per year
Two per year
Optional
Battery preventative maintenance*
One per year
One per year
Two per year
One per year^
Battery warranty extension to 3 years
eNotify remote monitoring service**
Discounted spare parts & upgrades
Discount on batteries
Firmware and technical updates
Access to customer service support centre
Duration of Service Plan
3 years
2 years
12 months
12 months
Notes:
1. * Applies to standard batteries only. Additional battery packs will require to be added on to the selected service plan.
2. ^ Additional preventative maintenance visits can also be added on to your service plan. Maintenance visits can be conducted monthly, quarterly or half yearly.
3. **eNotify remote monitoring will require a web card & EMP which requires to be purchased separately as it is not included in the service plans.
70
EATON CORPORATION UPS and Power Quality Products Catalogue
Protecting your investment
Site inspections: Consultative service that aims at securing the best
possible operational environment for your UPS to ensure its fault-free
operation.
Installation: Eatons service engineers can help you set up and
configure your entire UPS, including its connections to your monitoring
system and, if desired, to remote monitoring system.
Commissioning: Our service engineers help you start up your UPS and
make sure it works as intended, performing all necessary checks before
turning the system over to you.
Preventative maintenance: Equipment cleaning, inspection of installation
and operation environment, mechanical inspection, measurements and
adjustments, battery condition check, system check, event log analysis,
necessary action and eventual repairs. Usually performed once a year,
unless otherwise agreed.
Reports: After each maintenance visit, whether regular or emergency,
you receive a full written report on the fault and steps undertaken to
repair it.
24-hour telephone support: 24-hour, 365-days-a-year access to Eatons
support engineers for immediate help on your UPS system. Available
free of charge to all Service plan customers.
Extended warranty: For a small fee, you can extend the warranty of your
UPSs incrementally up to 5 years, for all single phase product range.
Power quality analysis: As time goes by, the loads on both your UPS
and the mains may change. Eatons service engineers can analyse the
quality of the power being fed to your equipment and suggest remedies
if necessary.
Battery analysis and replacement: Because batteries are the most
important part of a UPS, we pay particular attention to their condition.
Only rigorously tested, high-quality batteries are used in Eaton UPSs.
Battery life is optimised through our ABM battery charging method.
Eatons service engineers keep your batteries as good as new,
changing them when necessary and disposing of the old batteries in
an environmentally sound fashion. When the batteries are changed, all
cabling is also be replaced to prevent problems through oxidisation.
Finally, the battery system is tested under normal operating conditions.
System upgrades: During maintenance visits, our service engineers
analyse the load and performance of your UPS and, if necessary,
suggest changes to accommodate new needs. You will never find
yourself running an obsolete or undersized system.
Eaton WarrantyPlans
The Power Life Pack product is designed to provide warranty uplift to
our Single Phase product range. Warranty can be extended to a 3rd, 4th
or 5th year that includes a next business day response time, advance
replacement and startup services. Our Gold plan customers also
benefits from a yearly maintenance visit inclusive in the package.
Warranty+ Includes
Next Business Day Response*
Advance Replacement^
Dedicated on-line assistance available 5x8 from our qualified
support staff
Warranty + Silver
Next Business Day Response*
Advance Replacement^
Dedicated on-line assistance available 5x8 from our qualified
support staff
Startup** inspection of electrical installation, checking
compliance with current standards and regulations (A.C
cabling install not included)
Our qualified service technicians will train you on system
operation and provide maintenance recommendations
Warranty + Gold
Next Business Day Response*
Advance Replacement^
Dedicated on-line assistance available 5x8 from our qualified
support staff
Startup** inspection of electrical installation, checking
compliance with current standards and regulations (A.C
cabling install not included)
Our qualified service technicians will train you on system
operation and provide maintenance recommendations
Preventative Maintenance^^ visit to be performed annually
Notes:
1. * Available for sites located within 100km radius from an Eaton Office / Service Agent.
2. ** Startup Service and training on system operations is available upon request.
3. ^ Eaton takes care of product retrieval and new product shipment including all logistics and
associated cost.
4. ^ Maintenance visit is generally scheduled 8-9 months from date of installation. To be
conducted during business hours (Mon-Fri).
5. PLP registration to be done within 30 days from date of purchase @ www.eatonplp.com.au
Spare parts: Entering an Eaton service agreement guarantees you the
use of only the best quality, factory-approved spare parts. Authorised
Eatons service representatives stock the most often needed spares,
and their stocks are quickly replenished from Eatons strategically
located regional logistics centres. The cost of spares is included in all
Powertrust Service Plan options.
On line Remote Service: Your UPSs can link directly to Eatons regional
Service Centre via the Web. Remote monitoring software residing on
Eatons computers will keep an eye on your UPS status, sounding an
alarm immediately if its monitored parameters are out of the ordinary.
The remote monitoring system can only link into your UPS. It has
absolutely no access to your business data. Alarms received are relayed
by mobile phone to Eatons duty engineer who takes action immediately.
The remote monitoring is an ideal enhancement to your service
package. Ask your Eaton representative for details.
www.eaton.com/powerquality 1300 UPS UPS
71
Eaton Corporation is a diversified power management company ranked
among the largest Fortune 500 companies. The electrical group is a global
leader in electrical control, power distribution, power quality, automation,
and monitoring products and services. Eatons global electrical product
lines, including Cutler-Hammer, MGE Office Protection Systems,
Powerware, Holec, MEM, Santak and Moeller, provide customerdriven PowerChain Management solutions to serve the power system
needs of the industrial, institutional, government, utility, commercial,
residential, IT, mission critical and OEM markets worldwide.
PowerChain Management solutions help enterprises achieve sustainable
and competitive advantages through proactive management of the
power system as a strategic, integrated asset throughout its life cycle.
With Eatons distribution, generation and power quality equipment;
full-scale engineering services; and information management systems,
the power system is positioned to deliver powerful results: greater
reliability, operating cost efficiencies, effective use of capital, enhanced
safety, and risk mitigation.
Eaton Australia:
Eaton Sales
1300 877 877
Eaton Service 1300 303 059
Eaton New Zealand:
Eaton Sales
0508 328 6669
Eaton Corporation Pty. Ltd.
Electrical Sector
10 Kent Road Mascot,
NSW 2020 Australia
1300 UPS UPS (1300 877 877)
www.eaton.com/powerquality
Eaton Corporation Pty. Ltd.
Electrical Sector
1 Barry Hogan Place,
Christchurch 8041 NZ
0508 EATON NZ (0508 328 6669)
www.eaton.co.nz
PowerChain Management
is a trademark of Eaton
Corporation. All other
trademarks are property
of their respective owners.
LanSafe, Eaton, ePDU, Flex, PowerChain
Management, PowerTrust, Powerware,
PowerPass, X-Slot, and PowerVision
are trade names, trademarks, and/or
service marksof Eaton Corporation.
All other trademarks are the property of
their respective owners. 2011 Eaton
Corporation All Rights Reserved.
Due to continual product improvement,
specifications are subject to change
without notice.
Printed in AUS. 555PQ
72