5 Ce52 Design of RC Structures
5 Ce52 Design of RC Structures
SEM:SUMMER
NOTE: Missing data, if any may suitably be assumed. Use if IS 456-2000 and SP-16 is permitted.
1.a)
b)
Derive an expression for percentage of tension, for a given factored moment, material
properties and sectional properties.
Determine the characteristic strength of concrete which has given the following
compression test results on 150mm cubes.
40, 45, 38 41, 39, 51 48 38 N/mm2
c)
06
04
10
OR
2.a)
b)
3.a)
b)
Design a doubly reinforced beam is of 300mm x 600mm overall size, with an effective
cover of 50mm on both the compression and tension sides, factored moment 400 KNm. Use M20 concrete and Fe 415 steel. Sketch the details of reinforcements.
What is a doubly reinforced beam? Explain the circumstances of using doubly
reinforced beams.
Explain for any two types of shear failure in R.C beams with the help of neat sketches.
A simply supported beam 300mm wide and 600mm effective depth carries a uniformly
distributed load of 70 KN/m including its own weight over an effective span of 5 mts.
the reinforcement consists of 4 bars of 25mm diameter, out of these, two bars can be
safely bent up at one m distance from left support. Design the shear reinforcement for
the beam. Use M20 concrete and Fe 415 steel.
10
06
04
16
OR
4.a)
A simply supported slab 120mm thick a span 3.60m is reinforced with 10mm diameter
at 100 mm pitch at an effective cover of 20mm, if concrete grade is M20 and steel
grade Fe 415. Calculate the deflection due to creep for slabs, when it carries imposed
live load of 2 KN/m2 and floor finish 1KN/m2. Assum e 50% live load to be permanent
and creep co efficient = 1.6.
20
5.a)
20
OR
6.a)
b) A cantilever beam projects 2.5m beyond the fixed end and carries a super imposed
load of 12KN per meter run. Design the cantilever using M20 concrete and Fe 415
steel. The width of support is 350mm and width of cantilever beam is 250mm. sketch
the details of reinforcement.
7.a)
b)
Design a Cantilever chejja slab projecting 1.50 m from support wall. Adopt a live load
2.0 KN/m2, use M20 concrete and Fe 415 grade of steel, floor finish 0.50 KN/m2 and
ceiling finish 0.375 KN/m2. Sketch the details of reinforcement.
16
iq
Explain the difference between one way slab and two way slab.
OR
8.a)
9.a)
Determine the reinforcement for a column of a braced frame for the following data.
Pu = 1800 KN. M ux = 150 KN-M, Muy = 110 KN-m, unsupported length of column = 4m.
Effective cover 50mm use M20 concrete and Fe 415 steel.
20
Design a rectangular footing for a rectangular column 230mm x 460mm to carry a load
of 1300 KN. The safe bearing capacity of soil is 130 KN/m2. Use M20 concrete and Fe
415 steel. Sketch the details of reinforcements.
20
OR
10.a)
Design a suitable stair for an office building which has a stair room measuring 2.6m x
5.0m. The height of the floor is 3.6m. Live load is 4 KN/m. Sketch the reinforcement
details. Wall = 230mm. R=150mm T=250mm. Adopt M25 concrete and Fe 415 steel.
**************
20