Punching Shear Check For Circular Column
Punching Shear Check For Circular Column
Fcu
Fy
Fc'
=
=
=
40
420
32
T
d'
d
=
=
=
350
40
310
D
s
=
=
=
400
40
1
=
=
1000
100
2230.530784
2230.53
=
=
0.6
0.4
=
=
691464.54
132665289.7
=
=
1.4462
0.3015
1.7477
0.75
Critical Section
b0
=
=
=
2.1637467504
2.6618957187
1.4000714267
Vnmax
2.1213203436
0.7212489168
Vs =( Vu-Vc)/
Vs
1.61
Av /S = Vs / (Fyt *d)
Minimum No: of legs required
No: of Legs /side
Shear reinforcement Diameter
Spacing
Av /S
=
=
=
=
=
7.269
2
4
16
101
=
=
5404.98
1520.4582623
0.5 sqrt(fc')
Vn
Use T16@100mm Spacing with 4 no: legs to a distance of 1550mm from column edge
No: of Rows
17
Mpa
Mpa
Mpa
mm
mm
mm
mm
KN
KNm
mm
mm
mm
mm2
mm3
Mpa
Mpa
Mpa
208.4839
Mpa
Mpa
Mpa
Vc < Vu, Need shear reinforcement
Mpa
OK, Slab thickness is adequate
Mpa
1112.594 KN
mm2/mm
legs/side
mm
mm
mm
mm
804.2477
946.4