0% found this document useful (0 votes)
1K views6 pages

Punching Shear Check For Circular Column

This document provides input parameters and calculations for checking punching shear in a flat slab with a circular column. The slab thickness is 350mm with a concrete cover of 40mm, giving an effective depth of 310mm. The column diameter is 400mm. Material strengths and loadings are provided. Punching shear calculations are shown to check the ultimate shear stress against the factored concrete punching strength. As the ultimate shear stress exceeds the factored punching strength, shear reinforcement is designed with 4 legs of 16mm bars spaced at 100mm, extending to 1550mm from the column edge.

Uploaded by

Jansher Sadik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views6 pages

Punching Shear Check For Circular Column

This document provides input parameters and calculations for checking punching shear in a flat slab with a circular column. The slab thickness is 350mm with a concrete cover of 40mm, giving an effective depth of 310mm. The column diameter is 400mm. Material strengths and loadings are provided. Punching shear calculations are shown to check the ultimate shear stress against the factored concrete punching strength. As the ultimate shear stress exceeds the factored punching strength, shear reinforcement is designed with 4 legs of 16mm bars spaced at 100mm, extending to 1550mm from the column edge.

Uploaded by

Jansher Sadik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

Check for Punching shear in Flat slab with Circular Column

Material Input Data


Cube Compressive Strength
Reinforcement steel grade
Cylinder Concrete strength
Slab and Column Section
Slab Thickness
Concrete Cover
Effective Depth
Column Diameter

Fcu
Fy
Fc'

=
=
=

40
420
32

T
d'
d

=
=
=

350
40
310

D
s

=
=
=

400
40
1

=
=

1000
100

2230.530784

2230.53

=
=

0.6
0.4

=
=

691464.54
132665289.7

=
=

1.4462
0.3015

1.7477

0.75

Ultimate Shear Force


Factored Bending moment

Critical Section

b0

Size of opening within column strip


or within 10 times slab thickness, if any
b0effect
Moment Transfer
Flexural portion of moment (f)
Eccentric shear portion (v) = 1- f
Shear Parameters
Ac= bo * d
Jc1/C
Ultimate shear Stress
V/Ac
v*M2/(Jc2/C)
Ultimate shear stress Vu
Concrete Punching Strength:

Vc (1)= 0.17(1+2/c) SQRT (fc')


Vc (2)= 0.083(s*d/bo+2) SQRT (fc')
Vc (3)= 0.33 SQRT (fc')

=
=
=

2.1637467504
2.6618957187
1.4000714267

Vnmax

2.1213203436

vc (for punching RFT 0.17SQRT(fc')

0.7212489168

Vs =( Vu-Vc)/

Vs

1.61

Av /S = Vs / (Fyt *d)
Minimum No: of legs required
No: of Legs /side
Shear reinforcement Diameter
Spacing

Av /S

=
=
=
=
=

7.269
2
4
16
101

=
=

5404.98
1520.4582623

0.5 sqrt(fc')

Vn

Design of Shear Reinforcement


11.11.3.1

Distance of shear reinforcement


B0req
Distance from column

Use T16@100mm Spacing with 4 no: legs to a distance of 1550mm from column edge
No: of Rows

17

Mpa
Mpa
Mpa
mm
mm
mm
mm

KN
KNm

mm
mm

mm

mm2
mm3

Mpa
Mpa
Mpa

208.4839

Mpa
Mpa
Mpa
Vc < Vu, Need shear reinforcement
Mpa
OK, Slab thickness is adequate

Mpa

1112.594 KN

mm2/mm
legs/side
mm
mm

mm
mm

from column edge

804.2477