A4.3 Insulation: Comparative Table of Insulating Materials

The document discusses the properties and specifications of polyurethane foam insulation. The insulation is composed of rigid polyurethane foam that is self-extinguishing and has a fire resistance classification of B2 or B3. It has an average density of 40 kg/m3 ± 10%, compression and tensile resistance over 1 N/cm2, and a thermal conductivity of 0.022 Kcal/m.h.°C. Tables are provided showing the coefficient of heat transmission (K value) for various thicknesses of insulation used in roofing and wall panels.

Uploaded by

Sathya Prakash
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views

A4.3 Insulation: Comparative Table of Insulating Materials

The document discusses the properties and specifications of polyurethane foam insulation. The insulation is composed of rigid polyurethane foam that is self-extinguishing and has a fire resistance classification of B2 or B3. It has an average density of 40 kg/m3 ± 10%, compression and tensile resistance over 1 N/cm2, and a thermal conductivity of 0.022 Kcal/m.h.°C. Tables are provided showing the coefficient of heat transmission (K value) for various thicknesses of insulation used in roofing and wall panels.

Uploaded by

Sathya Prakash
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A4.

3 INSULATION
Composed of rigid polyurethane foam, self-extinguishing in accordance with current European
standards
COMPARATIVE TABLE OF INSULATING MATERIALS

Equivalent
thermal
insulation
860 mm Bricks
380 mm Concrete
140 mm Timber
50 mm Cork
45 mm Fibreglass
40 mm Polystyrene
25 mm Polyurethane

Reaction to fire Class B2 or B3 in terms of DIN standard 4102 part 1


Average density 40 kg/m3 10%
Compression resistance 11 N/ cm2 (at 10% deformation)
Resistance to stretching 1 N/ cm2
Resistance to cutting 1 N/ cm2
Coefficient of thermal conductivity I=0.022 Kcal/m.h.C
Non-hygroscopic because made up of over 95% closed cells
Coefficient of heat transmission:
For single- and double-skinned roofing panels
Thickness (mm)
30
40
50
60

80

100

120

Coeff. K (W/m2*C)

0,55

0,44

0,36

0,31

0,25

0,20

0,16

Coeff. K (kcal/h*m2*C)

0,48

0,38

0,32

0,27

0,22

0,17

0,13

For single- and double-faced walling panels


Thickness (mm) 30

40

50

60

80

100

120

150

Coeff. K (W/m2*C)

0,64

0,50

0,40

0,34

0,26

0,21

0,18

0,14

Coeff. K (kcal/h*m2*C)

0,57

0,44

0,35

0,30

0,23

0,18

0,15

0,12

A4.4 LOAD-BEARING CAPACITY


This depends on the type of metal bearing surface, its thickness and the thickness of the layer of thermal
insulation, as stated in the tables in the specific product catalogues. Load-bearing capacities refer to the