0% found this document useful (0 votes)
190 views

Technical Data Pressure Drop Calculations: Case 1 Case 2

This document contains technical data related to pressure drop calculations for two cases of air flow through pipes. It lists the stream parameters like temperature, pressure, mass flow rate. It also provides the pipe sizing details like diameter, design factor, fluid velocity and viscosity. The calculations show the frictional pressure drop per 100 feet and per meter of pipe. It also accounts for pressure drops across bends and totals the pressure drops for each case.

Uploaded by

AJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
190 views

Technical Data Pressure Drop Calculations: Case 1 Case 2

This document contains technical data related to pressure drop calculations for two cases of air flow through pipes. It lists the stream parameters like temperature, pressure, mass flow rate. It also provides the pipe sizing details like diameter, design factor, fluid velocity and viscosity. The calculations show the frictional pressure drop per 100 feet and per meter of pipe. It also accounts for pressure drops across bends and totals the pressure drops for each case.

Uploaded by

AJ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

TECHNICAL DATA

PRESSURE DROP CALCULATIONS


Stream
Service
Phase (*)
Temperature (C)
Pressure (barg)
Mass Flow (kg/h)
Flowing (m3/h)
Mole Weight
Flowing Density (kg/m3)
Line Sizing
Nominal Diameter (inch)
Pipe Int. Diameter (inch)
Design Factor
Fluid velocity (m/s)
Fluid viscosity (cP)
Reynolds No
e/D
Error (%)
Calc. Fanning Factor
Pressure Drop (psi/100ft)
Pressure Drop (mmWC/m)
Length, m
Pressure Drop (mmWC)
Pressure Drop Across Bend
Friction Coeff. for Bend
Delta P per bend
No. of bends Assumed
Pressure Drop across Bends
Total Presure Drop, mm WC

Line No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Scrubber
Outlet

Case 1
AIR
V
40
0.105
50.00
40.34
28.80
1.24

Case 2
AIR
V
40
0.105
50.00
40.34
28.80
1.24

6
5.80
1.10
0.7
0.01
13,204
0.00031
-0.00786
0.00732
0.00
0.01
100.00
0.65

4
3.80
1.10
1.7
0.01
20,154
0.00048
-0.00388
0.00671
0.00
0.05
100.00
4.96

0.60
0.02
12.00
0.23

0.60
0.11
12.00
1.27

0.89

1.32

Pressure
Assumed
Assumed Duct Drop Across
Duct lengths
bends
Duct
mtrs
mmWC

Pressure
Drop Across
Duct
mmWC

Total
Pressure
Drop mmWC

Remarks