Software Directsoft5
Software Directsoft5
Programming versions
With DirectSOFT5 Programming Software,
selecting which software package you
need is a snap! You can select the fully
loaded package at its great low price, or
you may choose the FREE package. It has
all of the same programming functions as
the full package. However, it will only
download a program up to 100 words
long.
The fully-loaded version (PC-DSOFT5)
will program all of our DirectLOGIC
PLCs, some GE Series One Plus PLCs,
and TI305/405 SIMATIC PLCs. Refer to
the
chart
below
to
verify
compatibility.
Family
CPU
PLC compatibility
If youre using our DirectLOGIC products,
then compatibility is not an issue. All
DirectSOFT5 packages support all
DirectLOGIC CPUs. Our software also
supports many compatible products that
were offered by previous vendors of the
Koyo-designed PLCs. If youre buying the
software to program a compatible CPU,
check the following table to make sure
your CPU is supported. (Sorry, but if your
CPU is not shown, then it is not
supported.)
Direct SOFT5
(full version)
PC-DSOFT5
Direct SOFT5
(free version)
PC-DS100*
CPU Firmware
Version Needed to
Use IBox
Instructions
DL05
All
DL06
DL105
All
All
DL-230
D2-240
DL205
DL305
DL405
GE Series 1 PLUS
D2-250
D2-250-1
D2-260
D3-330**, D3-330P**
D3-340
D3-350
D4-430
D4-440
D4-450
IC610CPU105**
IC610CPU106**
325-07**, PPX:325-07**
330-37**, PPX:330-37**
330S-37**, PPX:330S-37**
335-37, PPX:335-37
425-CPU, PPX:425-CPU
435-CPU, PPX:435-CPU
* PC-DS100 is only available by download from our Website. This FREE, full-featured software package will download a program limited to 100 words.
** Requires Data Communications Unit (D3-232-DCU).
88
Software
1 - 80 0 - 633 - 0405
PLC
Overview
PC system compatibility
DL05/06
PLC
Following are the recommended system requirements for running DirectSOFT5 on a PC:
1 GHz CPU
CD-ROM for loading software
Windows 2000/XP (Home and Pro)
No DOS, OS/2, MacIntosh, LINUX or UNIX versions, or 16-bit versions available
512 MB RAM and 20 MB free hard disk space
At least one unused serial communications port or USB port using our USB-RS232, USB-to-serial
adapter and/or 10-Base-T or 10/100-Base-T Ethernet network card
Color SVGA monitor (1024 x 768)
DL105
PLC
DL205
PLC
DL305
PLC
DL405
PLC
Field I/O
NOTES:
Laptops: DirectSOFT5 is perfectly suitable for use with laptop computers as long as they meet the requirements shown above. Most laptops can be ordered with a serial port as an option, which will allow a direct connection to our DirectLOGIC PLCs. If your laptop has a USB port, consider using our USB to serial adapter,
USB-RS232. If your laptop has an Ethernet port and you are considering a DL05, DL06, DL205 or DL405 PLC,
consider using the H*-ECOM or ECOM100 Ethernet Communications Module to connect your PC to the PLC
(The D2-230 does not support the ECOM).
Monitors: Any size monitor will work, however, larger, higher resolution, monitors enhance the features of
DirectSOFT5.
Software
C-more
HMIs
Other HMI
AC Drives
Motors
DL06 CPUs
Port 1: 9.6 Kbaud
Port 2: 300 baud - 38.4K baud
Steppers/
Servos
Motor
Controls
Proximity
Sensors
DL05 CPUs
Photo
Sensors
Limit
Switches
DL205 CPUs
DL105 CPUs
Encoders
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
TBs &
Wiring
Power
Enclosures
DL305 CPUs
D3-330 (requires D3-232-DCU): 300 - 19.2 Kbaud
D3-340: Port 1/2: 300 baud - 38.4 Kbaud
D3-350: Port 1: 9.6 Kbaud
Port 2: 300 baud - 38.4 Kbaud
w w w. a u to m at i o n d i re c t . c o m / s o f twa re
DL405 CPUs
Appendix
Part Index
Or use an ECOM module in the DL05, DL06, DL205 (except D2-230) or DL405
local base to program over a high-speed Ethernet link.
Software
89
Family
D2-DSCBL
Only one
**
Port 1
D2-DSCBL
Port 2
D2-DSCBL-1
Port 1
D2-DSCBL
Port 2
D2-DSCBL-1
Only one
**
Port 1
D2-DSCBL
Port 2
D2-DSCBL-1
Only one
D2-DSCBL
D2-230
Only one
D2-DSCBL
Top port
D2-DSCBL
Bottom port
D2-DSCBL
Top port
D2-DSCBL
Bottom port
D2-DSCBL-1
Top port
D2-DSCBL
Bottom port
D2-DSCBL-1
D2-DCM (module)
Only one
D3-DSCBL-2
Only one
**
D3-330/D3-330P
Requires DCU*
D3-DSCBL-2
Top port
D3-DSCBL-1
Bottom port
D3-DSCBL-1
Top port
D2-DSCBL
Bottom port
D3-DSCBL-2
Only one
D3-DSCBL-2
D4-DSCBL
D3-DSCBL-2
Phone jack
D2-DSCBL
D4-DSCBL
D3-DSCBL-2
D4-DCM (module)
Only one
D3-DSCBL-2
Only one
**
Only one
D4-DSCBL
IC610CPU105/106
Requires DCU*
D3-DSCBL-2
325-07, PPX:325-07
Requires DCU*
D3-DSCBL-2
330-37, PPX:330-37
Requires DCU*
D3-DSCBL-2
Requires DCU*
D3-DSCBL-2
330S-37, PPX:330S-37
Requires DCU*
D3-DSCBL-2
Phone jack
D3-DSCBL-1
If DCU is used*
D3-DSCBL-2
If DCU is used*
D4-DSCBL
D4-DSCBL
D3-DSCBL-2
D4-DSCBL
D3-DSCBL-2
Only one
D4-DSCBL
DirectLOGIC DL06
DirectLOGIC DL105
D2-240
DirectLOGIC DL205
D2-250(-1)
D2-260
D3-340
DirectLOGIC DL305
D3-350
D3-DCM (module)
D4-430/D4-440
DirectLOGIC DL405
GE Series 1
TI305/SIMATIC TI305
Cable
D2-DSCBL
All versions
DirectLOGIC DL05
Port
Port 1
D4-450
335-37, PPX:335-37
425-CPU, PPX:425-CPU
N/A, PPX:430-CPU
TI405/SIMATIC TI405
435-CPU, PPX:435-CPU
Smart slice
810
Software
1 - 80 0 - 633 - 0405
PLC
Overview
DL05/06
PLC
D2-DSCBL <--->
DL105
PLC
D2-DSCBL-1 <--->
DL205
PLC
DL305
PLC
DL405
PLC
Field I/O
Software
D3-DSCBL-1 <--->
C-more
HMIs
Other HMI
D3-DSCBL-2 <--->
AC Drives
Motors
Steppers/
Servos
Motor
Controls
D4-DSCBL <--->
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
TBs &
Wiring
Power
Enclosures
Appendix
Part Index
w w w. a u to m at i o n d i re c t . c o m / s o f twa re
Software
811
DirectSOFT5 Functions
Click to start
programming
Utilities, such as
CTRIO WB
Documents
(Projects most recently
used listed first)
Communication links to PLCs
ladder Palette
Documentation
Documentation is the text associated with the components and
structure of your program. It helps to clarify the representation of
elements by assigning four different fields: Description, Wiring
Info, Nickname, and Element.
Onscreen views
DirectSOFT5 defaults to a new Tab view to give you the most optimized viewing
area. You still have the option to view multiple windows in the original MDI format
by simply hitting the Restore button in the upper right of the active tabbed window,
or go to Windows menu and select one of the tile or cascade options. You can have
multiple windows open to view such things as all of the addresses used in the
program, a mnemonic view of the program instructions, and all of the instructions
used.
812
Software
1 - 80 0 - 633 - 0405
DirectSOFT5 Functions
PLC
Overview
DL05/06
PLC
DL105
PLC
DL205
PLC
DL305
PLC
DL405
PLC
Field I/O
PID view
Software
DirectSOFT5 offers an excellent PID feature. The loop and trending screens
are very easy to configure. This feature has all of the views, trending, and
tuning that you need to easily and successfully set up your PID loop.
C-more
HMIs
Other HMI
AC Drives
PID
Motors
Steppers/
Servos
Motor
Controls
Proximity
Sensors
OFFDTMR - Off Delay Timer will delay the "turning off" of the Output parameter by the specified Off Delay Time
Photo
Sensors
PONPOFF - Push ON/Push OFF Circuit toggles an output state whenever its
input power flow transitions from off to on
Limit
Switches
Encoders
MATHBCD - Math - BCD Format lets you enter complex mathematical expressions like you would in Visual Basic, Excel, or C++
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
TBs &
Wiring
CTREDRL - CTRIO Edit Preset Table Entry and Reload, on a leading edge transition to this IBox, will perform this dual operation to a CTRIO Output
resource in one CTRIO command.
Power
Enclosures
Appendix
Part Index
w w w. a u to m at i o n d i re c t . c o m / s o f twa re
Software
813