R O O M I N D E X UF Approximation: Room Informations Utilization

The document contains information about the dimensions, lighting specifications, and lighting calculations for a room. It lists the room's length, width, height, work area height, light-ceiling distance, and room index value. It also provides the reflectance values for the ceiling, walls and floor. The number of lights, desired light level, lumen output per light, maintenance and utilization factors, and required number of lighting units are specified. Charts with room index values and the corresponding utilization factor approximations are included.

Uploaded by

e_haitham_jamal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
138 views3 pages

R O O M I N D E X UF Approximation: Room Informations Utilization

The document contains information about the dimensions, lighting specifications, and lighting calculations for a room. It lists the room's length, width, height, work area height, light-ceiling distance, and room index value. It also provides the reflectance values for the ceiling, walls and floor. The number of lights, desired light level, lumen output per light, maintenance and utilization factors, and required number of lighting units are specified. Charts with room index values and the corresponding utilization factor approximations are included.

Uploaded by

e_haitham_jamal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Room Informations

Utilization

Length(m)
Width(m)
Hight(m)

5.53
3.7
4

Work office hight(m)

0.75

Light-ceiling distance(m)
Hm (m)
Room Index K

0
3.25
0.68209

R ( ceiling)

0.8

R( walls)

0.5

R (floor)

0.3

No. of lights in one unit n

E ( Lux)
F ( Lumen) for each light

300
3250

Maintainance Factor MF
Utilization Factor UF
No. of Lighting Units

0.8
0.386941
3.050707

Reflection

R
O
O
M
I
N
d
E
X

R ( ceiling)
R( walls)
R (floor)

Column1
0.8
0.5
0.3

0.6

0.35

0.8

0.44

0.51

1.25

0.58

1.5

0.64

0.72

2.5

0.77

0.81

0.85

0.89

UF Approximation
UF1
UF2
K1
K2
K
UF ( Result)

0.35
0.44
0.6
0.8
0.68209
0.386941

Column2 Column3 Column4 Column5 Column6Column7 Column8 Column9


0.8
0.8
0.8
0.7
0.5
0.5
0.3
0
0.5
0.3
0.3
0.5
0.3
0.3
0.3
0
0.1
0.3
0.1
0.2
0.3
0.1
0.1
0

imation

0.33

0.28

0.27

0.33

0.26

0.25

0.24

0.18

0.42

0.37

0.35

0.41

0.34

0.32

0.31

0.24

0.48

0.44

0.41

0.48

0.4

0.38

0.36

0.3

0.53

0.5

0.47

0.54

0.46

0.44

0.42

0.35

0.58

0.56

0.52

0.58

0.51

0.48

0.46

0.39

0.64

0.65

0.59

0.65

0.58

0.55

0.52

0.45

0.68

0.7

0.64

0.7

0.63

0.59

0.56

0.49

0.71

0.76

0.68

0.73

0.67

0.62

0.59

0.52

0.74

0.81

0.71

0.76

0.71

0.65

0.62

0.55

0.76

0.84

0.74

0.79

0.74

0.68

0.64

0.57

Column9

You might also like