ABSTRACT-Direct torque control method is a powerful control technique for specially Induction motor drive.
Now a days Direct Torque Control using Digital signal processors more popular in the ac motor control, in
particular the induction motor drives. The quick response and smooth control of DSP's are being utilized to
perform real time simulation on the ac motor variables, such as electromagnetic torque, fluxes, mechanical
speed, etc. This paper presents the implementation of a high performance induction motor control technique
known as direct torque control (DTC) utilizing three level inverter and compare between basic DTC scheme and
modified DTC scheme(Three level inverter) to minimize the sampling period of the implemented drive system,
DTC drives. Experimental results of this high performance drive system on a5hp standard induction motor are
as expected and agree with the theoretical work Index term: Induction motor3phase, 5HP, Voltage source
Inverter
I. INTRODUCTION
IM control technique using direct torque control (DTC), was introduced about a few year ago,
has a relatively simple and wide range of control structure at least as good as the FOC technique . It
is also known that DTC drive is less sensitive to parameter changing. DTC method is based mainly on
space vector theory by selecting proper space vector voltage across the sampling period the required
control on stator flux and torque is obtain. The DTC drive consists of DTC controller, torque and flux
calculator, and a voltage source inverter (VSI) as depicted in Figure 1. The configuration is much
simpler than the FOC system. The technique can be easily implemented with using hysteresis
controllers that is one for torque and for flux. The implementation of DTC of IM, although simple but
requires a fast processor to perform real time simulation of electromagnetic torque and stator flux
based on sampled terminal variables. Still micro-controllers have been used extensively in scalar or
vector control of AC machines. However, to obtain a high performance and smooth control AC
Induction motor drives, use of a fast processor is required. The solution to this problem is to use a
processor that can perform fast calculations of the estimated values that in the case of DTC is the
torque and stator flux. With the current research trend in motion control, undoubtedly, the DSP-based
system will dominate the above problem. This is particularly true, example, with the newly introduced
DSP TMS320F2407 family and DSP controllers which are specifically designed for digital motor
control.
Vab Va Vb
-
-------
(1)
Vbc Vb Vc
------- (2)
Vca Vc Va
------- (3)
Stator flux behavior compared to rotor flux is shown in fig after step variation stator
pulsation, the initial pulsation and allows the step variation. Controlling the stator flux and
electromagnetic torque control achieved by using the appropriate stator voltages can quickly change
the electromagnetic torque. Choosing suitable voltage vectors which increases or decreases y the
causes the electromagnetic torque to increase or decrease.
Fig shows the partition of the complex plan in six angular sectors S I= 16
System core consists of a flux and torque calculated and from that width of the hysteresis can be
determine, a flux and speed controller and a torque are determine by two measure motor stator flux
current, the dc voltage and the state of the switches, references of flux and torque are compared with
actual value of flux and torque and two level for flux and three level for torque hysteresis control
method produces control signal
vs(t)=2/3(vsA(t)+avsB(t)+a2vsC(t)),where a=e2/3 --------(7)
vsA, vsB,vsC are the instantaneous phase that voltage
For the switching VSI it can be shown for a DC link voltage of Vd, the voltage space vector is given
by Sa(t), Sb(t), and Sc(t) are the switching functions of each leg of VSI, such that
The stator flux linkage of an IM can be expressed in the stationary reference frame (w=0) with the
help of the following two equations.
International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 74 | Page
--------- (8)
---------
(9)
The IM stator voltage equation which is in the stator reference frame (=0) is given by:
-----
(10)
Where Vs, Is, s are the stator voltage, current and stator flux space vectors respectively. According
to equation above if the stator resistance is small and can be neglected, the change in stator fluxThis
simply means that the tip of the stator flux will follow that of the stator voltage space vector
multiplied by the small change in time.
-------- (11)\
For one period of the voltage applied remain constant
----------- (12)
hence if the voltage drop due to stator resistance is ignored then above equation can be written
as
-------- (13)
Hence if the stator flux space vector (magnitude and angle) is known, its locus can be
controlled by selecting appropriate stator voltage vectors. In DTC the stator flux space vector is
obtained by calculation utilizing the motor terminal variables (stator voltages and currents). The stator
flux is forced to follow the reference value within a hysteresis band by selecting. The electromagnetic
torque is proportional to the vector product between stator vector and rotor flux and the expression is
-------- (14)
Where
s = stator vector flux
r = rotor vector flux and
= angle between stator and rotor flux vector
International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 75 | Page
REFERENCES
[1] Yatim A.H.M ;Idris N.R.N Implementation of Direct torque control of induction machine utilizing TMS320C31digital signal
processor,Signal Processing and Its Application, Sixth International,Symposium,2001volume :2 digital object identifier;
10.1109/ISSPA.2001.950223,publication year:2001,pages:627-630
[2] Toh, C.L.; Idris, N.R.N.; Yatim, A.H.M.;Muhamad,N.D.; Elbuluk, M.Implementation of New Torque and Flux controllers for Direct
Torque Control (DTC) of
Induction Machine Utilizing
Digital Signal Processor(DSP) ,Power Electronics Specialists
Conference,2005,Pages:1594-1599. P ESC05 IEEE 36th digital Object Identifier: 10.1109 /PESC.2005.1581843Publication Year: 2005 ,
Page(s): 1594 - 1599
[3] Toh,C.L.;Idris,N.R.N.;Yatim,A.H.M.;Muhamad,N.D;Elbuluk,M Implementation of a New Torque and flux Controllers for Direct
Torque control of Induction Machine Utilizing Digital Signal Processor and Field programmable Gate Arrays Power Electronics Zhou,
L.Q. DSP- controlled Direct Torque Control of Induction Machines ,Industrial Electronics and Application ,2007.ICIEA 2007.2nd IEEE
conference on Digital Object Identifier: 10.1109/ICIEA.2007.4318718,Publication year :2007,pages:1790-1793IEEEconference Publication
[4] Rekioua, D.; Rekioua, T. DSP-controlled direct torque control induction machines based on modulated hysteresis control
Microelectronics(ICM),2009International Conference on , DigitalObject Identifier:10.1109/ICM.2009.5218603 Publication Year: 2009 ,
Page(s): 378 381 Cited by: 1 IEEE Conference Publications Specialists Conference,2005.PESC 05.IEEE 36th
DigitalObjectIdentifier:10.1109/PESC.2005.1581843 Publication Year:2005,page(s):1594-1599
[5] H. Ibrahim ; M.Aktas. Direct torque control of induction machine drives using adaptive hysteresis band for constant switching
frequency, Electric machines & Drives Conference,2007,IEMDC 07.IEEE International volume:2 Digital Object
Identifier:10.1109/IEMDC.2007.383697 Publlication Year:2007,page(s) :1762-1767
[6] Habetler, T.G.; Profumo, F.; Pastorelli, M. Direct torque Control of induction machine over a wide speed range , Industry Application
Society Annual Meeting 1992.,Conference Record of the 1992 IEEE.,Digital Object Identifier : 10.1109/IAS.1992.244340 Publication Year:
1992 , Page(s): 600 - 606 vl.1 Cited by: 8 IEEE Conference Publications