Hi 60856
Hi 60856
Configuration Software
General Description
The H-S81-HS panel can be programmed using the software ProHS81.
The program, which is supplied separately from the panel, can be installed on any PC provided with either a serial port or a link for network connection with the panel to be programmed.
A USB port is also necessary for the protection key that is used to prevent tampering and unauthorized modification after testing.
ProHS81 allows the programmer to make the most effective use of panel and hardware modularity. Besides being simple to use, it utilizes video
windows including tables and selection menus consistent with both panel composition and desired functions.
Configuration Method
The H-S81-HS panel is mainly composed of one basic unit and one or more racks, where cards selected according to the type of system
installed are inserted.
Whatever its special function, each card acts as a device connecting and controlling the input (detection) and output (command) field devices.
Once they have been inserted into the racks, the cards must be configured through ProHS81 programming to define:
1.
2.
3.
4.
1) Definition of inputs
Determination of behavior and time of delay of inputs.
Physical location and addressing of devices.
2) Definition of actuators
Determination of behavior and time of delay of outputs.
Physical location and addressing of devices.
It defines the status variations of inputs to determine the activating conditions of outputs.
Possible Configurations
At a general configuration level, it is possible to define:
Panel and program language
Panel display parameters
Panel heading and general information on the type of the panel
Communication method for panels, PCs and printers
Panel and supervision PCs IP addresses
CPU and cards redundancies
Time-related operation and periodical test functions
Program and configuration protection parameters.
At panel (and system) functional level, it is possible to configure:
AND, OR, N/N logic associations relevant to inputs and outputs managed by panel
Logic associations on other network-connected panels
Logic associations and events determined by time frame variations.
The logic associations can be configured for a maximum of 300 fire extinguishing zones and technologically controlled zones. Each zone can
have 99 inputs, 99 outputs, and 99 logic associations.
www.honeywell.com
www.honeywell.com
This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice.
+1 203-484-7161
fax: +1 203-484-7118
Pasadena, TX 77507
www.honeywell.com
+1 713-577-1510
HI-60856
March 2015
2015 Honeywell International Inc.