Plumbing Review
Plumbing Review
2.
General Regulations
3.
Which of the following is suitable for testing a DWV system for leaks?
a. Air
b. Water
c. Smoke
d. All of the above
It is common for modern DWV systems to be tested with air. In the old days water was the most
common means of testing. When there is a leak that cannot be found easily, smoke can be used to
expose the leak location. Smoke is not used as a primary test method. Air is the test medium of
choice. The testing of a DWV system is to be conducted for a minimum of 15 minutes. The minimum
test pressure is required to be 10 pounds per square inch (PSI). If only underground plumbing is
being tested there must be one riser that is at least ten feet above the main plumbing system.
4. All pipe used in plumbing applications will have all of the following markings except:
a. Pressure rating in psi
b. Nominal pipe size
c. Length of pipe
d. Manufacturer's brand name
Some pipe manufacturers list measurement in one foot increments when rolls of pipe are 100' or
over, but do not list increments on joints of 21', 20' or less. Brand names, psi rating, and nominal
pipe size are required.
Fixtures
5.
Handicap toilets are available with heights that include 16 inches, 18 inches and 20 inches.
6. What is the minimum unobstructed opening of egress when a shower door is installed for a
typical shower?
a. 22 inches
b. 24 inches
c. 28 inches
d. 30 inches
The minimum unobstructed opening of egress for a shower door installed on a typical shower is 22
inches.
8. The minimum vertical distance from the bottom of an indirect drain line to its receptor's
flood rim is _____________________________.
a. 1"
b. "
c. "
d. 2"
Minimum vertical distance from the bottom of an indirect drain line to its receptors flood rim is 1".
10. You are connecting two back to back lavatories, two urinals and two water closets to one
horizontal branch. What are the maximum number fixtures that can be connected to a
horizontal branch?
a.3
b.4
c6
d.8
The plumbing code allows a maximum of eight fixtures connections to a horizontal branch drain.
This is also called a circuit vent.
12.
All flexible water connections are required to be accessible. This means that they can be concealed
in a cabinet or behind an access panel, but they must be accessible.
14. Water heaters, hose bibs and sill cocks are normally protected from backflow with
________.
a. An air gap
b. An air break
c. A vacuum breaker
d. A reduced-pressure backflow preventer
Vacuum breakers are normally used to protect water heaters, sill cocks and hose bibs from
backflow dangers.
The amount of grade, also referred to as pitch or fall, for a drain pipe is determined by the size of
the drain pipe. Master plumbers and other design professional establish these elements of a
plumbing system based on the minimum standards required by local code requirements. As a
general rule-of thumb, the proper amount of grade for a drain up to 4-inches in diameter is .25 inch
per liner foot.
16. What will result when a 4 inch pipe is reduced in size in the direction of the flow?
a. The waste will travel faster which will allow for better cleaning of the pipe.
b. This could cause blockage to build up at the reduction point.
c. This could cause slugging in the waste system.
d. This will have no affect on the drainage system.
At the reduction point, because of the direction of flow, waste can build up which will result in ping
system blockage.
18.
Water Heaters
19. Where is the maximum allowable working pressure of a storage tank and water heater
required to be shown?
a. In the installation guide
b. Stamped in the metal
c. On a permanently attached plate
d. Either b or c
Such markings shall be in an accessible position outside of the tank, permanently affixed.
20. The minimum depth thickness for a water heater drip pan is
__________________________.
a. 1"
b. 1.5"
c. 3/4"
d. 2"
1.5" is the minimum depth size for a drip pan.
a. Measured
b. Flow controlled
c. Filtered
d. Monitored
Any gray water going into a gray-water collection reservoir is required to be filtered. This is required
as a means of blocking solids from entering the collection reservoir. While the fixtures allowed for
the recycling of gray water should not be transporting solids there is always a possibility the some
type of solid could find its way into the drainage water. The filters stop these impurities from
reaching the collection of gray water that will be recycled.
22. What is the maximum amount of time that gray water is allowed to be retained for use to
flush a toilet or urinal?
a. 24 hours
b. 48 hours
c. 72 hours
d. 96 hours
The maximum allowable time for the retention of gray water that will be used to flush toilets or
urinals is 72 hours. Holding water for long periods of time can result in the growth of bacteria. This
bacteria is not wanted in the plumbing system. For example, green water in a toilet tank is not
appealing and could present health hazards. When a gray water recycling system is sized properly
the water retained in a collection reservoir would be balanced to the fixtures served and the normal
daily use of the fixtures will draw down from the reservoir often enough to avoid prolonged water
storage.
Fuel Gas
23. Gas piping installed in a laundry chute ____________.
a. Must be secured at maximum intervals of 6 feet
b. Must be protected from damage in the normal course of use of the chute
c. Is required to be installed with only vertical pipe sections
d. Is a code violation
Gas piping in not allowed to be installed in laundry chutes, dumbwaiters, air-circulating ducts or
elevators. The chutes, shafts and ducts can transport gas to various locations in a building if a leak
should occur. Therefore, it is inappropriate to install gas piping in a location that could distribute gas
beyond the location of the leak.
24. When flow controls are installed on gas piping, they _____________.
a. Must be accessible
b. Must not contain sediment traps
c. Must be equipped with a leak-limiting device
d. Are used to keep operating pressure lower than the supply pressure
Flow controls on gas systems are installed to keep the operating pressure of the system lower than
the supply pressure for the system. These devices prevent excessive pressure from the distribution
system. They must be approved and suitable both the inlet and outlet gas pressure for the
application. The flow controls must be readily accessible.
Math
25.
What is the angle made when you offset a sewer with a 1/8 bend?
a. 45
b. 60
c. 72
d. 90
26. What is the total force in pounds on a 6 inch diameter test plug with a water head of 15
feet?
a. 3.00 psi
b. 4.25 psi
c. 6.51 psi
d. 7.20 psi
psi = Height x Amount of pressure exerted at base of a one foot stack
psi = 15 x .434
psi = 6.51
1. Which of the following plumbing code in USA does the National Plumbing Code
B. ASPE Code
A. Res. No. 2
C. Res. No. 4
3. According to the Code, the desgign of roof gutters is based on the maximum
roof area. What is the shape of the gutter does the desgn table for storm sewer is
being based to?
o
A. Circular
B. Restangular
C. Ovate
D. Semi-circular
A. Restraining order
B. Partial permit
C. Summon
D. Evaluation sheet
A. ASSE
B. ASPE
C. ANSI
D.IAPMO
6. What type of PVC female screws for water piping is prohibited under the code?
A. Tapped
B. Job fabricated
C. Seamless
D. Schedule 20 screws
7. Within how many days upon the approval of Rep. Act No. 1378 does it require
A. Thirty days
B. Fortyfive days
C. Sixty days
D. Fifteen days
8.The minimum requirement for the slope of horizontal drainage pipes between
manholes is
A. 2%
B. 2 1/2%
C. 3%
D. 4%
A. Welded
B. Threaded
C. Soldered
10. Who has the power to remove any member of the Board of Master Plumbers
D. Commision on Appointments
A. Water Meter
B. Floor Drain
C. Urinal
D. Laundry Tray
13. Who is authorized to issue rules and regulations to carry into effect the
14. What is the minimum age requirement for an appointee to become a member
of the Board of Master Plumbers?
15. According to Rep. Act 1378 for at leasrt how many years must the appointee
to the Board of Master Plumbers must have been actively engaged in the trade of
plumbing?
A. Ten years
B. Eight years
C. Two years
D. Five years
16. Of the four board subjects given for Master Plumbers examination, which of
A. Practical Problems
C. Plumbing Code
D. Plumbing Arithmetic
17. A plumbing permit shall expire and become null and void if the plumbing work
B. 45 days
C. 100 days
18. Who was awarded as the most outstanding Registered Master Plumber for
the Year 2011?
A. Dave Vela
B. Alberto Azarcon
C. Alberto Cabael
D. Thelma Cardente
A. P 150.00B
B. Equal to the original fee
D. 1/2 of the original fee
D.365 days
20. For at least how many working days shall a required for inspection of the
A. 7 working days
B. 5 working days
C. 3 working days
D. 10 working days
21. Who is the current chairman of the Board of Examiners for Master Plumber?
A. Fortunato Amosco
B. Virgilio Simbulan
C. Jessie Mariano
D. Valerin Maogila
22. For a vertical drainage line that is installed to be truly in vertical position, what
is the allowed degeree of the branch to be used?
A. 10
C. 30
D. 60
23. A type of drainage and venting system with universal branch line that is
prohibited
A. Single
B. 45
B. Dual
C. Dependent
D. Alternate
24. Building sewers shall be tested by completely filling the sewer with water from
the ___
25. What is the name of the professional orginazation for the Registered Master
26. Aside from Bell and Spigot, B & S in the code means
B.14
D. 12
A. 1935
C. 18
B. 1956
C. 1946
D. 1968
29. In the water test of the entire plumbing system all openings should be tightly
closed except at
A. Producing cleanouts
B. Highest opening
C. Stack vent
D. Bleeders
30. Under what law did plumbing became a duly recognized profession by the
Philppine government?
o
D. None of these
32. What Congress of the Republic of the Philippines approved after the third
reading Rep. Act 1378 otherwise known as the Plumbing Law of the Philippines?
A. Third Congress
B. Sixth Congress
C. Second Congress
D. Fifth Congress
B. Upright pipe
C. Horizontal nipple
D. All of these
B. Comelio G. Odvina
D.Catalino C. Casupanan
35.Except for plastic piping system, hot and cold water piping may be tested wtih
___
o
A. 50 psi of the working pressure of the water in the system for at least 15 minutes
D. The vertical main of soil, waste, or vent piping that extends one or more stories
37. How many units do the controversial Article 3.2.2.2 of PD 1096 otherwise
known as the National Building Code limits the practice of Master Plumber?
A. 20
B.10
C. 5
D. 50
38. What is the minimum allowable interval for the support of plastic pipes when
installed vertically
A. 2ft
B. 5ft
C.1 meter
D. 1.5 meter
39. In 1966- 1969, the Board of Master Plumbers and NAMPAP prepared a
curriculum for Plumbing Engineering and approved by the Department of
Education. What was the first school that introduced the Plumbing Engineering
curriculum?
A. Feati University
D. National University
an access panel or utility at least 0.30 meter in its least dimension for easy
inspection and repair?
A. Slip joint
C.Hubless
D. Flanged
41. A fitting for lead-caulked joint that is prohibited when in vertical position
A. Single hub
B. Double hub
D. All of these
42. PD No. 1185 is another law that Master Plumbers used as their guide in the
practice of the plumbing profession.What is PD No. 1185?
A. Accessibilty Law
D. Code of Sanitation
43. To allow cleaning of the soil and waste line each cleanout should be installed
B. Opening upward
D. All of these
44. The appropriate sealant that will be used to cover void spaces between pipes
C. Grease
D. Putty
45. For the hot and cold water distribution system, on what side should the hot
water supply be placed in combination fittings?
A. Left
B. Epoxy
B. Right
C. Center
D. None of these
46. According to the Fire Code of the Philippines what is the required slope of all
B.20%
C. 5%
D. 2%
vertical vent pipes before offsetting horizontally to join the stack vent or vent stack?
A. Invert of trap
48. A kind of cleanout plugs that will be installed in case where raised heads may
B. Countersunk
C. Embedded
D. Recessed
49. What is the maximum water pressure must standpipe fittings and connections
B. 34 kg/cm
C.15 kg/cm
D. 8 kg/cm
C. On stack vent
51. What is the minimum pipe size of the standpipe if the highest outlet is located
more than 23 meters above the Fire Service connection?
A. 3 inches
B. 6 inches
C. 5 inches
D. 4 inches
52. What is the minimum pipe size of the standpipe if the highest outlet is located
B.6 inches
C. 5 inches
D. 4 inches
B. Wet standpipe
D. Siamese connection
54. Who among the Board Examiners is not a signatory to PRC Resolution 04
that request for the adoption and promulgation of the Revised National Plumbing
Code of the Philippines in 1999?
A. Imelda Perez
C. Sprinkler system
55. For new, additional or altered plumbing installation not exceeding 20 units, the
Building Code stated that a Licensed Master Plumber could sign and affix his seal
on the follwing engineering documents except
C. Isometric drawing
56.In sizing the grease interceptors, four elements are being used. Two of these
elements are number of meals per peak hour and the waste flow rate. Whta are the
other two elemets?
57. If the discharge of a fixture or drain may contain solids or semisolids heavier
than water that would be harmful to the drainage system or cause stopaage within
the system, where the discharge must pass first?
A. Sand interceptor
C. Wooden baffle
58. What is the minimum number of approved slip joints fittings may be used on
the putlet side of the trap?
A. Three
B. Two
C. None
D. One
59. Except on what fixture does the vent pipe opening from the soil or waste pipe
A. Lavatory
B. Kitchen sink
C. Bath tub
D. Water closet
60. According to the Building Code of the Philippines what is the range in height
A. 30 cm to 1.2 m
B. 60 cm to 1.5 m
C. 80 cm to 1.8 m
D. 50 cm to 1.0 m
A. Kitchen sink
C. Washing machine
D. Bidet
62. The Building Code stated that all dry standpipe outlets shall be equipped with
valves having substantial chains. What kind of valve is this?
A. Check valve
B. Bath tub
B. Globe valve
C. Gate valve
D. Ball valve
D. None of these
64. Aside from the number of fixture units connected to it, the size of the vent
B. Length
C. Discharge
D. Loading
65. To what provision does the design, construction and operation of deep wells
D. Code of Sanitation
66. Drainage piping serving fixtures located below the crown level of the main
A. Septic tank
B. Sump
C. Cesspool
D. Leaching tank
67. Who shall set the criteria for the quality of drinking water from meteoric,
B. Department of Health
68. Where the number of water closets in a floor level exceeds 20, how many of
B. 2
C. 3
D. 4
C. Imhoff tank
70. What is the maximum distance as where supports of vertical cast iron soil
B. Every meter
C.Every storey
D. Every joint
71. Whenever the piping is pressurized by a pump or ejector, what kind of pipe
D. None of these
72. What government agency is tasked to set the criteria in the discharge of
sanitary sewage from buildings or pretreated industrial wastewater directly into the
nearest sanitary sewer main?
C. Department of Health
73. Where practical, all pipes from fixtures shall be run in what direction with
B. Parallel
C. Across
D. Perpendicular
74. What is the minimum height of raised letters on an iron or bronze sign that will
B. 1/4inch
C. 25mm
D. 30mm
75. With what standard specification must all pipe materials must conform to?
B. Three years
C. Two years
D. Five years
A. A registered engineer
B. An engineering graduate
D. A member of NAMPAP
78. The following are the data required whenever a Registered Master Plumber
B. PTR date
D. None of these
79. According to Art 3.2.2.2 of PD 1096 what scope of work in plan preparation for
new sanitary installations with more than 20 units does a sanitary engineer differs
with a Registered Master Plumber?
o
C. Cost estimate
81. In the excreta drainage system, which of the following pipe materials should
not be used underground?
82. Which of the following could be omitted if the trap arm changes direction that
does not exceed 90 degrees?
A. Wye
B.Cleanout
C. Long sweep
83. How does a pneumatic tank be designed to supply adequate water pressure
in all floors of a building that will be in accordance with the Building Code?
D. Equal to the total dynamic head and minus all the head losses
84. What is the masimum length of the fire hose that shall be equipped on wet
standpipes?
A. 12 meters
B. 23 meters
C.17 meters
D. 25 meters
85. What is the type of Siamese connection that all 125-millimeter dry standpipes
B. Two-way
C.Four-way
D. One-way
86. What is the nimimum floor area in every storey which is used for habitation,
recreation, dining, study of work and which has an occupiped load of not more than
20, wherein a standard automatic extinguishing system is a
A. 300 sq.m
C. 400 sq.m
D. 500 sq.m
87. Which of the following is a prohibited fixture inside a public toilet room?
A. Faucet
B. 200 sq.m
B.Drinking fountain
C. Slop sink
D. Bidet
88. Aside from galvanized steel, what is the other material for dry standpipe that
B.Wrought iron
C.PE pipe
D. Brass
89. Where should the overflow pipe lead for overhead tank installed on buildings?
A. Soil stack
D. Gutter
C. Storm drain
90. What portion of the trap should the vent pipe opening will not go below from a
soil or waste pipe?
A. Slip joint
B. Scuppers
B. Weir
C. Sleeve
D.Seal
91. The following are grounds for non-issuance of the certificate of registration by
B. Of unsound mind
92. What should be done whenever a partition contains some piping and runs
parallel to the floor joist underneath?
93. Which of the following is the primary basics for sizing vertical rainwater piping
A. Intensity of rainfall
B. Wind direction
C. Slope of roof
D. Roof area
A. CONCRETE
B. STEEL
C.PLASTIC
D. WOODEN
95. If ever pipes are to pass through masonry by using pipe sleeves, how far
must each pipe be from each other?
96. What is the minimum number of water closet in a floor level wherein you have
to provide 1 water closet for disabled persons as provided by Batas Pambansa Blg.
344? in excess of this number you have to provide 2.
A. 12
B. 15
C. 20
D. 10
97. What is the shape for the signage for women's comfort room in order to aid
B.RECTANGLE
D. SQUARE
98. What is the maximum height should a water closet have if it is intended for a
disabled person.
A. 0.40m
C.TRIANGLE
B. 0.50m *
C. 0.45m
D. 0.35m
99. Accordingto Batas Pambansa Blg. 344, what type of urinal should be provided
A. WALL-HUNG TYPE
B. PEDESTAL TYPE
C. TROUGH TYPE
D. NONE OF THESE
100. For how many days shall the REvised National Plumbing Code will take
effect following its complete publication in the Official Gazette?
A. 100 days
D. RECTANGLE
C. TRIANGLE
B. GOVERNMENT
C. PRIVATE
D. COMPETENT
103. What is the minimum dimension for a turning space in a water closet stall
intended for disabled persons?
A. 2.00 m
B. CIRCLE
102. One of the Code of Ethics for Master Plumber states "Take advantage of a
salaried ____ position to complete unfairly with a practicing Master Plumber." What
is the missing word?
A.HIGHER
D. 30 days
C.50 days
A. SQUARE
B. 60 days
B. 1.20 m
C. 1.00 m
D. 1.50 m
104. In order as not to impede the movement of a person in wheel chair and to
have a convenient access on the lavatory, what is the allowable knee recess
vertical clearance that will be provided?
A. 0.50 m to 0.80 m
B. 0.60 m to 0.80 m
C. 0.40 m to 0.70 m
D. 0.60 m to 0.70 m
105. What is the minimum total net inlet area of roof deck drains on roof deck
106. When permitted by DENR, which of the following below is NOT used as a
basis in determining the type of the private sewage disposal system to be used?
A. SOIL POROSITY
C. NUMBER OF OCCUPANTS
D. LOCATION
107. What is the maximum allowable lead content of pipe and fitting for potable
piping system?
A. 0%
B. 2%
C. 5%
D. 8%
108. What is the minimum horizontal clear dsitance from the septic tank to the
C. 1.5 m
D. 1.8 m
109. If a septic tank has a compartment that exceed 3.7 m in length, what should
be the additional requirement?
A. An additional manhole
110. What is the minimum diameter of vent pipe is allowed in the revised Code?
A. 1 inch
B. 1.2 m
B. 1 1/4 inch
C. 2 inch
D. 1 1/2 inch
111. What installation standard is followed in joining plastic pipe and fittings by
solvent cement?
A. ISO
C. IAPMO
D. ASHRAE
112. Under the Accessibilty Law, what is the minimum area of water closet stalls?
B.ANSI
113. Within how many meters away shall unions be installed from regulating
equipment, water heater, conditioning tank and similar equipment which require
removal for servicing or replacement?
A. 2 ft
B. 1 m
C. 5 ft
D. 0.3 m