0% found this document useful (0 votes)
405 views5 pages

80 KW Perkins Diesel Generator - TP-P80-T3-60-UL

Manual Book

Uploaded by

Permana Hasno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
405 views5 pages

80 KW Perkins Diesel Generator - TP-P80-T3-60-UL

Manual Book

Uploaded by

Permana Hasno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

80 KW / 100 KVA

POWERED by

MODEL

TP-P80-T3-60-UL

Triton Power is a world leader in the design,


manufacture of stationary, mobile and rental generator
sets and Power Modules from 10 to 2000 kW. Through
our commitment to quality we manufacture with only the
highest quality components from companies like
Cummins, John Deere, Perkins, Marathon, and Deep
Sea. All of this plus our worldwide warranty, customer
service professionals, is why Triton is the

THE POWER OF QUALITY


Available Voltage
3 Phase
120/208, 110/220, 120/240, 277/480
Power Factor 0.8

Standby
Prime

kVA
kW
kVA
kW

100
80
90
70

Standby : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 .
Prime : Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,
ISO 3046.

High quality, reliable and complete power unit


UL-2200 LISTED
Compact design
Easy start and maintenance
Every generator set is subject to a comprehensive test program
which includes full load testing and checking and providing of all
control and safety shut down functions testing
Full engineered with a wide range of options and accessories:
o Sound Attenuated Enclosure
o Trailer with fuel tank
o UL Listed Fuel Tank
o Permanent Magnet Generator
o Electronic Governor

Agency Approval: UL 508 R CSA C22.2 No 14 NFPA 110


CE Compliance: EC LVD-73/23/EEC EN 61000-6-4:2001 EMC EN 50178:1997
EMC- 89/336/EEC
EN 610000 6-2:2001 EMC Immunity
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
All photos are representative and may not reflect exact model

ENGINE INFORMATION
ENGINE MAKE
Model

PERKINS
1104D-E44TAG1

Engine Speed

RPM

1800
Tier 3

Tier Rating
Engine Power Output at
rated rpm

kWm

96.8

HP

129.8

Cooling

Radiator Cooled

Aspiration
Total Displacement

Liter

Turbocharged air-to-air charge


cooled
4.4

No. of Cylinders and Build


Bore and Stroke

4-inline
mm x mm

105 x 127

Compression Ratio

16.2:1

Governor
Fuel Consumption (L/hr)

Electronic
Full Load

23.7

75% Load

18.7

50% Load

13.5

Fuel Tank Capacity

Liter

Optional

Oil Capacity

Liter

Coolant Capacity

Liter

17

m/min

182

Radiator Cooling Air


Economic Power

Compact, Clean and Efficient Power

Mechanically operated unit fuel injectors with


electronic control, combined with carefully matched
turbocharging, provide excellent fuel economy and
low emissions.

Exceptional power to weight ratio and compact size


give optimum power density for ease of installation
and more cost effective transportation.

Designed to provide excellent service access for


ease of maintenance.

Reliable Power
Developed and tested using the latest engineering
techniques and finite element analysis for high
reliability, low oil usage and low wear rates.
High compression ratios ensure clean rapid starting
in all conditions.

Product Support
Total worldwide service is provided through a
network of 4,000 distributors and dealers.

TIPSS - The Integrated Parts and Support System


enables customers to specify and order parts
electronically.

Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
All photos are representative and may not reflect exact model

CONTROLLER INFORMATION
DEEP SEA MODEL 7320
The DSE7320 is an Auto Mains (Utility) Failure Control Module suitable for a wide variety of single, diesel or gas, gen-set
applications. A sophisticated module monitoring an extensive number of engine parameters, the DSE73xx will annunciate
warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LED, remote PC, audible alarm
and via SMS text alerts. The module includes RS232, RS485 & Ethernet ports as well as dedicated terminals for system
expansion.
Configurable inputs (11)
MAIN FEATURES:
Fuel usage monitor and low fuel alarms
Configurable outputs (8)
Charge alternator failure alarm
Voltage measurement
Manual speed control (on compatible CAN
Mains (utility) failure detection
Dedicated load test button
kW overload alarms
Comprehensive electrical protection
RS232, RS485 & Ethernet remote
communications
Modbus RTU/TCP
PLC functionality
Multi event exercise timer
Back-lit LCD 4-line text display
Multiple display languages
Automatic start/Manual start
Audible alarm
Fixed and flexible LED indicators
Event log (250)
Engine protection
Fault condition notification to a designated PC
Font panel mounting
Protected front panel programming
Configurable alarms and timers
Configurable start and stop timers
Five key menu navigation
Front panel editing with PIN protection
3 configurable maintenance alarms
CAN and Magnetic Pick-up/Alt. sensing

engines)
Manual fuel pump control
Protections disabled feature
Reverse power protection
Power monitoring (kW h, kV Ar, kV A h, kV Ar
h)
Load switching (load shedding and dummy load
outputs)
Automatic load transfer
Unbalanced load protection
Independent Earth Fault trip
Fully configurable via DSE
Configuration Suite PC software
Configurable display languages
Remote SCADA monitoring via
DSE Configuration Suite PC
software
Advanced SMS messaging
(additional external modem required)
Start & stop capability via SMS messaging
Additional display screens to help with modem
diagnostics
DSENet expansion compatible
Integral PLC editor

BENEFITS

RS232, RS485 & Ethernet can be used at


the same time
DSENet connection for system
expansion
PLC functionality
Five step dummy load support
Five step load shedding support

Worldwide language support


Direct USB connection to PC
Ethernet monitoring
USB host
Data logging & trending

OPERATION

The module is operated using the front STOP/RESET, MANUAL, AUTO, TEST and START
pushbuttons. An additional pushbutton next to the LCD display is used to scroll through the
modules metering displays.

Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
All photos are representative and may not reflect exact model

ALTERNATOR INFORMATION
Manufacturer

Stamford

Design

Brushless single bearing, revolving field

Stator

2/3 pitch

Rotor

Single bearing, flexible disc

Insulation System

Class H

Standard Temperature Rise

125 -163C Continuous

Exciter Type

Self Excited

Phase Rotation

A (U), B (V), C (W)

Alternator Cooling

Direct drive centrifugal blower fan

AC Waveform Total Harmonic Distortion


Telephone Influence Factor (TIF)

No load < 1.5%. Non distorting balanced linear load


< 5%
<50 per NEMA MG1-22.43

Telephone Harmonic Factor (THF)

<2%

STANDARD ITEMS
Mainline Circuit Breaker
Generator Set mounted on Heavy Duty Steel Base Frame
Anti-Vibration Pads between Engine/Alternator and Frame
Forklift Pockets within Base Frame (up to 400 kW)
Battery Charging Alternator

OPTIONAL ITEMS
ENGINE OPTIONS

Engine Block Heater


Racor Fuel Water Separator
Oil Heater

ALTERNATOR
OPTIONS

Permanent Magnet Generator


Anti-Condensation Heater
Oversized Alternator (Motor Starting)

OTHER OPTIONS

Sound Attenuated Enclosure with Critical Silencer (70 db at 7 meters)


Trailer (with or without fuel tank)
UL-142 Base Mounted Fuel Tank
Residential or Critical Grade Silencer

Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
All photos are representative and may not reflect exact model

WEIGHT AND DIMENSIONS

SKID MOUNTED GENERATOR


DIMENSIONS (LxWxH)
DRY WEIGHT

In
lb

Inquire
Inquire

SOUND ATTENUATED GENERATOR


DIMENSIONS (LxWxH) without TANK
DRY WEIGHT
FEATURES AND BENEFITS OF ENCLOSURE:

All enclosure parts are modular


No welding to reduce corrosion
Doors on both sides for easy maintenance
All metal parts are powder coated

In
lb

122.28 x 41.85 x 63.9


3550

Critical Exhaust Silencer Included


Thermally insulated exhaust system
Emergency stop located on exterior
Easy Lifting and Moving

TRITON POWER CORP


8511 NW 61 STREET MIAMI, FL USA
Phone: 305-592-6300 Fax: 305-592-5900 E-mail: [email protected]
www.americasgenerators.com
Triton Power is a subsidiary of Americas Generators, Inc.

Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
All photos are representative and may not reflect exact model

You might also like