GRUNDFOS DATA BOOKLET

CR, CRI, CRN, CRT


CRE, CRIE, CRNE, CRTE
Custom-built pumps
50/60 Hz

CR, CRI, CRN, CRT,

Table of contents

1.

Introduction

Customised CR pumps
Pumps for individual requirements

3
3

2.

Overview

3.

Performance range

CR
CRT(E)

7
8

Identification

Type keys

4.
5.

Applications

10

High-pressure applications
Hot-water applications
Applications involving temperature control
Aggressive/hazardous liquids
Hygienic applications
Special installation requirements
Special applications

10
11
12
13
14
15
16

Accessories

17

ATEX-approved dry-running protection


Venting valve with connecting pipe

17
17

9.

Pump

36

PN 25 and PN 40 pumps
Measurement of inlet pressure
Pumping of liquids down to -40 C
Surface treatment
CRN all-stainless steel pumps
CR low NPSH
Horizontal inline pumps
Horizontal end-suction pumps
Belt-driven pumps
CR(I) deep-well pumps
Pump rubber parts
Empty chambers
Bearing flange
Support bearings
Bearing material
Pump head positions
Customised nameplate
Dry-running protection
Connections

36
36
36
37
38
38
39
42
43
45
46
46
46
47
48
48
48
48
49

10. Certificates
6.

7.

8.

Motor

18

VIK-approved motors
Tropicalised motors
cURus-, UR- and CSA-approved motors
Other motor approvals
ATEX-approved pumps
Special voltage
Motor with multiplug connection
Motor with anti-condensation heater
Motors with PTC sensors
Motors with thermal switches
Oversize motors
Undersize motors
Alternative enclosure class (IP)
Alternative terminal box positions
4-pole motors
Motor efficiency classes
Other motor makes

18
18
18
18
19
19
20
21
22
22
23
24
25
25
25
25
25

Shaft seals

26

Shaft seal arrangements


Overview of shaft seals
Shaft seal variants
Double seal arrangements

26
26
26
27

CR pumps with certificates

11. CRE pump solutions


CRE pump with extended functional module
Customised CRE pump solutions

12. How to read the curve charts


Guidelines to curve charts

13. Performance curves


CR deep-well
Low-NPSH pumps
CR pumps with 4-pole motor

14. Technical data


CR low-NPSH pumps

15. Technical data


CR deep-well pumps

16. Technical data


CRN pumps with magnetic drive
CRN pumps with magnetic drive

17. Technical data


CRH(N) pumps
CRH(N) pumps

18. Motor data


Standard 2-pole motors for
CR, CRI, CRN, 50 Hz
Standard 4-pole motors for
CR, CRI, CRN, 50 Hz
Standard 2-pole motors for
CR, CRI, CRN, 60 Hz
Standard 4-pole motors for
CR, CRI, CRN, 60 Hz

54

59
59
60

65
67

68
68
70
86

110
110

137
137

139
139
142

153
153
154

160
160
160
161
161

19. Pumped liquids

162

20. Further product documentation

165

WebCAPS
WinCAPS

54

165
166

CR, CRI, CRN, CRT,

This catalogue is a supplement to these data booklets:


CR, CRI, CRN, CRE, CRIE, CRNE
CRT, CRTE
CR, CRN high-pressure pumps.
It gives an overview of some of the customised
solutions offered by Grundfos. If the catalogue does
not provide a solution to your specific pumping needs,
please contact us with a detailed description of your
problem, and we will get down to work - for you!

Customised CR pumps
We offer a wide range of customised variants of the
CR type range for a variety of demanding industrial
applications.
With these multistage in-line pumps, based on the
well-known CR type range, we meet the customers
needs for pumps capable of handling special
installation requirements and these liquids:
high-temperature liquids
crystallising liquids
high-viscosity liquids such as paints and varnishes
aggressive liquids
volatile liquids
flammable liquids.
Most of the pumps are available with either
mains-operated motors (CR, CRI, CRN and CRT) or
electronically speed-controlled motors (CRE, CRIE,
CRNE and CRTE).
Customised pumps from CR 1s to CR 90 are available
for these temperature ranges:
Water-based liquids: -40 C to +180 C.
Thermal oils:
-20 C to +240 C.
The below pump types are available as customised
pumps.
Pump
type

1s

CR(E)

CRI(E)

CRN(E)

Pumps for individual requirements


The CR pumps can be customised to meet individual
requirements. This is due to the "mix-and-match"
approach to customisation, where the many pump
features and options are to be regarded as modules
that can be combined to create the ideal pump for the
job at hand.
Motor options
CR motors are available in many different
configurations to meet the requirements presented by
the power supply, the pump environment and/or the
pumped liquid itself.
Power supply systems vary in terms of both
frequency and voltage, and required protection
methods.
Your environment may be explosive, very hot and/or
very humid. Special conditions also apply at high
altitudes.
The pumped liquid can call for a special motor
solution. High or low viscosities and/or high or low
densities may require non-standard motor sizes.
You may also need an explosion-proof variant.
The installation site of the pump may require
alternative positions of pump and motor parts, such
as terminal box positions and vent screw positions.
For further information, see section 2. Overview.
Shaft seal options
Extreme liquids sometimes call for extreme measures.
High temperatures damage seal faces unless
precautions are taken.
Concern for safety can necessitate special
measures for aggressive, toxic or flammable liquids.
Liquids can be harmful to shaft seals because they
crystallise, harden or are extremely abrasive.
For further information, see section 2. Overview.

10 15 20 32 45 64 90 120 150

Pump options

The CR pump elements can handle the most


demanding liquids and pressures, and be adapted to
suit many other requirements.
Horizontal installation if height is a limitation.
Poor inlet conditions mean that NPSH values must
be adjusted to avoid cavitation.
Very high pressures demand special solutions.
Special surface treatments or certificates may be
required.
For further information, see section 2. Overview.

Available.

Note: CRT(E) 2, 4, 8 and 16 are also available as


customised pumps.

Introduction

1. Introduction

Connection options
Your chosen pump elements can be fitted with exactly
the connection options you need. All standards are
covered, and special connection variants are available
for maximum compactness, high liquid pressures etc.
For further information, see section 2. Overview.

CR, CRI, CRN, CRT,

Introduction

Features and benefits


Customised CR pumps have the following features and benefits:

GR5357

Grundfos motor
Grundfos motors are remarkably silent and highly efficient.
Three-phase pumps from 1.1 to 75 kW have premium efficiency IE3
motors as standard.
Grundfos motors are available with integrated frequency converter
designed for speed-controlled operation.
Shaft seal solutions
The specially designed cartridge seal increases reliability, ensures safe
handling and enables easy service and access.
The cartridge shaft seal comes in a wide choice of materials. It is
available in single and double seal arrangements and magnetic drive
configurations.
Connections
The Grundfos CR pump can be connected to any system.
Material options
The Grundfos CR pump is available in four different material variants:
CRT(E):
Titanium
CRN(E):
Stainless steel AISI 316
CRI(E):
Stainless steel AISI 304
CR(E):
Stainless steel AISI 304/cast iron.
Wide range of pump sizes
The CR pump comes in 13 flow sizes and hundreds of pressure sizes,
ensuring that you can always find exactly the right pump for the job.
High-performance hydraulics
Pump efficiency is maximised by the optimised hydraulics and carefully
crafted production technology.
Dry-running protection
The patented Grundfos LiqTec system eliminates the risk of
breakdowns due to dry running. If there is no liquid in the pump, the
LiqTec will stop the pump immediately.

CR, CRI, CRN, CRT,

Overview

2. Overview

4-pole motors

Explosion-proof
motors

Anti-condensation
heater

Multiplug
connections

CSA/UL-approved
motors

See page 25.

See page 19.

See page 21.

See page 20.

See page 18.

Shaft seals

Rubber parts

Titanium

Non-cartridge
solution

CR pumps with
air-cooled top

See page 26.

See page 27.

See page 26.

See page 26.

See page 31.

CR high-pressure
pumps

Horizontal
mounting

All-stainless steel
CR pumps

CRH, horizontal
end-suction
pumps

Low temperature

See page 10
and 36.

See page 15
and 39.

See page 38.

See page 42.

See page 12
and 36.

Oval flanges (CR)

Flanges (CR)

PJE connections
(CRI, CRN)

Flanges
(CRI, CRN)

Clamp
connections
(CRI, CRN)

See page 53.

See page 53.

See page 52.

See page 53.

See page 51.

2
Overview
6

CR, CRI, CRN, CRT,

VIK-approved
motors

Oversize or
Motor protection undersize
motors

Special voltage

Enclosure class

Terminal box
positions

See page 18.

See page 22.

See page 23.

See page 19.

See page 25.

See page 25.

MAGdrive

Back-to-back
seal
arrangement

CR pump with
pressure
intensifier

CR pump with
barrier liquid

Tandem seal
arrangement

Dry-running
protection

See page 34.

See page 27.

See page 29.

See page 28.

See page 30.

See page 48.

See page 17.

Alternative
colour

Bearing flange

Pump rubber
parts

CR low-NPSH
pumps

CR deep-well
pumps

Belt-driven CR
pumps

Bearing
materials

Surface
treatment

See page 37.

See page 46.

See page 46.

See page 11
and 38.

See page 16
and 45.

See page 15
and 43.

See page 48.

See page 37.

Oval flanges
(CRI, CRN)

TriClamp
connections
(CRN)

Union
connections
(CRI, CRN)

PJE connections
(CRT)

Customised
solutions

Certificates

See page 53.

See page 49.

See page 53.

See page 53.

See page 53.

See page 54.

Accessories

CR, CRI, CRN, CRT,

Performance range

3. Performance range
CR
50 Hz
H
[m]

50 Hz

400
300
CR 32
CRN 32

200

CR 150
CRN 150
CR 120
CRN 120

100
80
60

CR 1s

CR 3

CR 10

CR 20

CR 64

CRI 1s

CRI 3

CRI 10

CRI 20

CRN 64

CRN 1s

40
30

CRN 3

CRN 10

CRN 20

CR 1

CR 5

CR 15

CR 45

CR 90

CRI 1

CRI 5

CRI 15

CRN 45

CRN 90

CRN 1

CRN 5

CRN 15

20
0.8
1

10

20

30

40 50 60

80 100

200

Q [m/h]

Eta
[%]
80
60

20
0
0.8
1

10

20

30

40 50 60

80 100

200

Q [m/h]

TM02 1192 4708

40

Note: CRE, CRIE, CRNE pumps are available up to 22 kW.


60 Hz
H
[m]

60 Hz

400
300
200

CR 150
CRN 150

CR 120
CRN 120

100
80
60

CR 1s

CR 3

CR 10

CR 20

CR 45

CR 90

CRI 1s

CRI 3

CRI 10

CRI
20

CRN 45

CRN 90

CRN 1s

40
30

CRN 3

CRN 10

CR 1

CR 5

CR 15

CRI 1
CRN 1

CRI 5
CRN 5

CRI 15
CRN 15

CRN
20

CR 32

CR 64

CRN 32

CRN 64

20
0.8
1

10

20

30

40 50 60

80 100

200

Q [m/h]

Eta
[%]
80
60

20
0
0.8
1

10

20

30

40 50 60

80 100

200

Q [m/h]

TM02 1530 4408

40

Note: CRE, CRIE, CRNE pumps are available up to 22 kW.

CR, CRI, CRN, CRT,

Performance range

CRT(E)
50 Hz
H
[m]

CRT

300

50 Hz
200

100
90
80
70

CRT 2

CRT 4

CRT 8

CRT 16

60
50
40

20
1

9 10

20

30

40

Q [m/h]

TM03 3817 1106

30

Note: CRTE pumps are available.


60 Hz
H
[m]

CRT

300

60 Hz
200

100
90
80
70

CRT 2

CRT 4

CRT 8

CRT 16

60
50
40

20
1

9 10

20

30

40

Q [m/h]

Note: CRTE pumps are available.

TM03 3818 1106

30

CR, CRI, CRN, CRT,

Identification

4. Identification
Type keys
Pump
Example

CR E 32 s -4 -2 -A -F -G -E -HQQE

Type range:
CR, CRI, CRN, CRT
Pump with integrated frequency
converter
Flow rate [m 3/h]
Undersize impeller (all impellers)
CR 1s, CRI 1s, CRN 1s
Number of impellers
Number of reduced-diameter impellers
CR(E), CRN(E) 32, 45, 64, 90, 120, 150
Code for pump version
Code for pipe connection
Code for materials
Code for rubber parts
Code for shaft seal

Key to codes
Code

Description

Pump version
A
B
D
DW
E
F

G
H
HS
I
J
K
M
N
P
R
SF

V
X

Basic version
Oversize motor
Pump with pressure intensifier
Deep-well pump with ejector
Pump with certificate
Pump for high temperatures (with air-cooled top)
Multi-E slave
Horizontal version
High-pressure pump with high-speed MGE motor
Different pressure rating
Pump with a different maximum speed
Pump with low NPSH
Magnetic drive
With sensor
Undersize motor
Horizontal version with bearing bracket
High-pressure pump
Multi-E master
Special version

Code

Description

Code for rubber parts in pump


E
F
K
V

EPDM
FXM (Fluoraz)
FFKM (Kalrez)
FKM (Viton)

Shaft seal type designation


A
D
H
K
O
P
X

O-ring seal with fixed driver


Balanced O-ring seal
Balanced cartridge seal with O-ring
Type M as cartridge seal
Double seal, back-to-back
Double seal, tandem
Special version

Seal face material


B
C
H
U
Q
X

Carbon, synthetic resin-impregnated


Other types of carbon
Cemented tungsten carbide, embedded (hybrid)
Cemented tungsten carbide
Silicon carbide
Other ceramics

Secondary seal material (rubber parts)


E
F
K
V

EPDM
FXM (Fluoraz)
FFKM (Kalrez)
FKM (Viton)

Shaft seal
Example

-H

-Q

-Q

-E

Shaft seal type designation


Material of rotating seal face
Material of stationary seal face
Material of secondary seal (rubber parts)

Pipe connection
A
B
CA
CX
F
G
J
N
P
X

Oval flange
NPT thread
FlexiClamp
Triclamp
DIN flange
ANSI flange
JIS flange
Changed diameter of ports
PJE coupling
Special version

Materials
A
D
G
GI
I
II
K
S
X

Basic version
Carbon-graphite filled PTFE (bearings)
Wetted parts EN 1.4401/AISI 316
All parts stainless steel, wetted parts EN 1.4401/AISI 316
Wetted parts EN 1.4301/AISI 304
All parts stainless steel, wetted parts EN 1.4301/AISI 304
Bronze (bearings)
SiC bearings + PTFE neck rings
Special version

CR, CRI, CRN, CRT,

Applications

5. Applications
High-pressure applications

GR7767 - TM02 8470 4004

2-pump solutions

Fig. 1

CR high-pressure pumps

Reference applications

Filtration
reverse osmosis
cleaning and washing
boiler feed.

Further documentation
Information about
CR high-pressure pumps (standard documentation)
Pumps with bearing flange
Customised pump parts

see page
165
46
18-63

Customised solutions

Special installation requirements

15

High-pressure applications often expose pumps to a


variety of extreme conditions, such as high inlet
pressure, high operating pressure, frequent
starts/stops and pressure pulsing.
Overload of the pump may cause increased wear of
pump parts, such as motor bearings and shaft seal,
and thus reduce the pump life.
To avoid unexpected breakdowns, we offer customised
solutions designed to meet your needs!

E-pump solutions

59

WebCAPS

165

High-pressure handling
We offer high-pressure pumps specially designed to
cope with pressures up to 50 bar at max. +120 C.
When necessary, CR high-pressure pumps are fitted
with a bearing flange. A bearing flange is an additional
flange with an oversize ball bearing designed to
absorb axial forces in both directions.
CR high-pressure pumps come in two variants: as a
single-pump solution or as a 2-pump solution.
The single-pump solutions is used for flow rates up to
5 m3/h, the 2-pump solution for flow rates above
5 m3/h.
Single-pump solution
Our single-pump solutions include the pump types
CRNE 1 HS and CRNE 3 HS.
CRNE HS pumps are fitted with a high-speed motor
with integrated frequency converter.
To minimise the pressure on the shaft seal, the
direction of rotation is the opposite of that of standard
pumps, and the chamber stack is turned up-side down.
Consequently, the pumped liquid flows in the opposite
direction.

10

Our 2-pump solutions are divided into two groups


based on pump size:
CRN 3, 5, 10, 15, 20 SF
CR(N) 32, 45, 64, 90, 120, 150.
Both solutions consist of two pumps in series. The first
pump is a standard pump for feeding. The second
pump is a high-pressure pump especially designed for
high pressure.
To minimise the pressure on the shaft seal, the
direction of rotation on CR SF pumps is the opposite of
that of standard pumps, and the chamber stack is
turned up-side down. Consequently, the pumped liquid
flows in the opposite direction.

Supplementary Grundfos pumps


For pressures above 50 bar, we recommend Grundfos
BM modules or Grundfos BME, BMET pumps.
For further information about BM modules and BME,
BMET pumps, see page 165.

CR, CRI, CRN, CRT,

Hot-water applications

Fig. 2

CR pumps for hot-water applications

Reference applications

Boiler feeding
applications involving poor inlet/suction conditions
cleaning and washing applications
high-temperature applications.

Hot-water applications often expose pumps to a variety


of extreme conditions, such as high temperatures, long
operating hours, frequent starts/stops, pressure
pulsing, poor inlet conditions and high inlet pressure.
Such conditions may result in cavitation and/or cause
increased wear of pump parts, for instance motor
bearings and shaft seal, and thus reduce the pump life.
To avoid breakdowns, we offer customised solutions
designed to meet your needs! We provide solutions for
applications involving special requirements:
steady steam production
poor inlet conditions
high temperature, etc.
Steady steam production
To ensure a steady steam production and a constant
water level in the boiler tank, we recommend
speed-controlled pumps.
Why speed-controlled pumps are recommended:
The reaction to changes in the steam consumption
is faster compared with mains-operated pumps.
The water level in the boiler feed tank is kept stable.
The installation costs are lower compared to
systems with mains-operated pumps and valves.

Fig. 3

Further documentation
Information about

see page

CR low-NPSH pumps

38

CR pumps with air-cooled top

31

Pumps with bearing flange

46

CR pumps with under-/oversize motor

23

Customised pump parts

18-63

Special installation requirements

15

E-pump solutions

59

WebCAPS

165

10 bar
+170 C
Boiler

Burner

The pumping of hot liquids demands much of pump


parts, such as the shaft seal and rubber parts.
To ensure a reliable and stable production, we offer CR
pumps with an air-cooled top.
A CR pump with an air-cooled top has a standard
mechanical shaft seal handling liquid temperatures up
to +180 C at 25 bar without external cooling. At the
same time the pump delivers a high pressure. As the
name implies, the pump is fitted with a special
air-cooled shaft seal chamber generating the same
insulation effects as that of a vacuum flask.

TM03 2615 4605

Controller

Cavitation is often a problem in applications where


pumps have to cope with the combination of high liquid
temperatures, poor inlet pressure and/or high flow
rate.
Low-NPSH pumps eliminate the risk of cavitation and
ensure a stable and reliable operation.
The CR low-NPSH pump is a pump with a special first
stage design that reduces the pumps NPSH value and
prevents erosion and destruction of the pump,
pipework and valves.
For further information about NPSH and the calculation
of NPSH-value, see these data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CR, CRN high pressure
CRT, CRTE.
High-temperature applications

Customised solutions

Condensate

Applications

GR5228 - GR7767 - TM02 8470 4004

Applications involving poor inlet conditions

Boiler-feed application with speed-controlled pump

11

CR, CRI, CRN, CRT,

TM02 7397 3403

Applications

Applications involving temperature


control

Fig. 4

CRE, CRIE, CRNE pumps with sensor

The pumping of hot liquids demands much of pump


parts, such as shaft seals and rubber parts. Examples
of such liquids:
water-based liquids up to +180 C at PN 25
thermal oils up to +240 C at PN 16.
To ensure a reliable and stable production, we offer CR
pumps with an air-cooled top and special rubber parts.
A CR pump with an air-cooled top is a pump which can
handle high temperatures and deliver a high pressure.
The pump is fitted with a special air-cooled shaft seal
chamber generating the same insulation effects as that
of a vacuum flask.

Reference applications

Pumping of high-viscous liquids

Cooling systems:
Electronic data processing
laser equipment
medical equipment
industrial cooling and freezing processes, etc.
Temperature-control systems:
Casting and moulding tools
oil processing, etc.

In applications where high-viscous liquids are pumped,


precautions must be taken to ensure that the motor of
the pump is not overloaded, and that the pump
performance is not reduced too much.
The viscosity of a pumped liquid depends strongly on
the liquid temperature.
To ensure a stable and reliable operation, we offer CR
pumps with oversize motors.

Customised solutions
To ensure a safe and reliable operation in applications
involving temperature control, we offer customised
solutions designed to meet your needs!
We provide solutions for applications involving
pumping of the following liquids:
liquids at temperatures down to -40 C
high-temperature liquids
high-viscous liquids, etc.
Pumping of liquids down to -40 C
In applications where liquids are pumped at
temperatures down to -40 C, it is crucial for a
successful production that pump parts are of the right
materials and dimensions.
At such low temperatures, the selection of wrong
materials and dimensions may cause deformation
because of thermal expansion, and eventually
stoppage of operation.
For low-temperature liquids below -20 C, we
recommend CRN pumps.

12

Pumping of high-temperature liquids

Further documentation
Information about

see page

ATEX-approved pumps

19

CR pumps with air-cooled top

31

Pump rubber parts

46

CR pumps with oversize motor

23

Customised pump parts

18-63

Special installation requirements

15

E-pump solutions

59

WebCAPS

165

CR, CRI, CRN, CRT,

Aggressive/hazardous liquids

GR5954 - GR7369 - GR5216

Fig. 5

CR pumps for aggressive/hazardous liquids

Reference applications

Chemical industry
pharmaceutical industry
refineries
petrochemical industry
distilling plants
paint industry
mining.

Customised solutions
In industries where pumping of dangerous and
aggressive liquids is an integrated part of the daily
production, safety is top priority. Leaking pumps pose
a danger to the environment.
To prevent breakdowns, we offer customised solutions
designed to meet your needs!
We provide solutions for the following liquids:
aggressive and abrasive liquids
toxic and hazardous liquids
flammable liquids
odorous liquids.
To ensure a safe handling of the above liquids, we
offer the following pumps:
pumps with tandem seal arrangement and flushing
pumps with back-to-back seal arrangement and
pressure intensifier
pumps with magnetic drive (MAGdrive)
pumps with ATEX approval.
Pumps with tandem seal arrangement
Pumps with tandem seal arrangements connected to a
flushing device are used for crystallising, hardening or
sticky liquids.
If the primary seal leaks, the leaking liquid will be
flushed away by a flushing liquid.

Applications

Pumps with back-to-back seal arrangement


We recommend pumps with back-to-back seal
arrangements for toxic, aggressive or flammable
liquids.
Pumps with back-to-back seal arrangements are
connected to a pressure intensifier preventing leakage
from the pump to the atmosphere side.
MAGdrive pumps
We recommend pumps with magnetic drive
(MAGdrive) for toxic and hazardous liquids.
The MAGdrive pump is a hermetically sealed pump. In
the MAGdrive pump, the power from the motor is
transmitted to the pump shaft by means of magnetic
force instead of a traditional coupling.
The motor shaft and the pump shaft are hermetically
separated from each other.
ATEX-approved pumps
We recommend ATEX-approved pumps for potentially
explosive atmospheres. Explosive atmospheres
consist of air and combustible material such as gases,
vapours, mists or dusts in which the explosion spreads
after ignition.
We offer ATEX-approved pumps with these
classifications:
2G EExe II T3
2G EExd IIB T4
2G EExd IIC T4
2G EExde IIB T4
2G EExde IIC T4
EEx 2D T125
EEx 3D T125 .
Electropolished pumps
We recommend electropolished pumps for applications
with strict requirements concerning corrosion and
cleanability.
We offer electropolished pumps in all CRN pump sizes.
Further documentation
Information about
CR pumps with back-to-back seal arrangement

see page
27

CR pumps with tandem seal arrangement

30

Pumps with magnetic drive (MAGdrive)

34

ATEX-approved pumps

19

Customised pump parts

18-63

Special installation requirements

15

E-pump solutions

59

WebCAPS

165

13

CR, CRI, CRN, CRT,

Cleanability
TM02 1808 2001 - GR7375 - TM02 8470 4004

Applications

Hygienic applications

Fig. 6

CR pumps for hygienic applications

CR pumps are not designed for the pumping of


hygienic and sterile liquids, but their construction and
the choice of materials make them an ideal solution for
secondary processes in hygienic applications.

In secondary hygienic applications, it is extremely


important to clean the pumps sufficiently to prevent
deposits from contaminating the pumped liquid.
For secondary hygienic applications, we recommend
CRN(E) pumps which have all pump parts in stainless
steel. As the surface and properties of the metal is not
affected by cleaning agents, stainless steel is the ideal
solution.
ATEX-approved pumps
We recommend ATEX-approved pumps for potentially
explosive atmospheres. Explosive atmospheres
consist of air and combustible material such as gases,
vapours, mists or dusts in which the explosion spreads
after ignition.
Further documentation
Information about
Cleaned and dried CR pumps

Reference applications

Pharmaceutical industries
biotechnological industries
electronics industries
food and beverage industries
process industries.

37

Electropolished CR pumps

37

Stainless steel CRN pumps

38

ATEX-approved pumps

19

Customised pump parts

18-63

Special installation requirements

15

E-pump solutions

59

WebCAPS

165

Customised solutions

Supplementary Grundfos pumps

In hygienic industries, pumps must meet strict


requirements on design, materials, surface quality,
cleanability, etc.
To ensure a hygienic and reliable production, we offer
customised solutions specially designed to meet your
requirements!
We provide solutions for applications involving special
requirements to hygienic design and cleanability.

If sanitary pumps with a hygienic design are required,


we recommend the following Grundfos sanitary pump
types:
F&B-HYGIA
Euro-HYGIA
Contra
Sipla.
Most of the Grundfos sanitary pumps comply with the
QHD, EHEDG and 3-A sanitary standards.
For further information, see page 165.

Hygienic design
The surface quality of pump parts is of utmost
importance - both for corrosion resistance and
microbial adhesion and growth.
To meet the strict hygienic requirements to material
and surface quality in secondary hygienic processes,
we offer electropolished stainless steel CRN pumps
with the following surface quality:
Pump type
CRN 1s, 1, 3, 5,
10, 15, 20, 32, 45,
64, 90, 120, 150

Cast stainless Stainless steel Surface


steel
parts (not cast) quality

Ra 0.8 m

Available.

Furthermore, we offer a wide variety of connections,


such as TriClamp connections, specially designed for
pharmaceutical, food and beverage industries.
For further information about TriClamp connections,
see page 49.
We offer the following pumps:
cleaned and dried pumps
mechanically or electropolished pumps.
Electropolished pumps have a higher corrosion
resistance than non-polished pumps.

14

see page

CR, CRI, CRN, CRT,

Special installation requirements

Fig. 7

CR pumps for special installations

Reference applications

Applications

GR5886 - GR5379 - GR5887

Belt-driven pumps
Belt-driven pumps are often selected in the following
cases:
non-electrically driven applications for instance air-,
solar-, wind-, diesel- and pneumatically driven
applications
installations requiring an alternative supply, for
instance firefighting systems and emergency
pumps.
The construction of belt-driven pumps is like that of
electrically driven pumps, but belt-driven pumps have
a pulley and belt connected to a combustion motor or
other device.
Pumps with alternative mounting

Places with limited access and space


ships
mobile applications
fire protection
earthquake-prone areas
applications in remote areas.

For installations with limited access and space, we


offer pumps with alternative mounting of pump parts
such as terminal box and vent screw.
Certificates, approvals and reports

Customised solutions
Due to safety, location and arrangement requirements
some installations require pumps of another design
than traditional vertical pumps.
To meet special installation requirements, we offer
customised solutions designed to meet your needs!
We provide solutions for the following pump types:
horizontally mounted pumps
belt-driven pumps
pumps with alternative mounting, etc.
Horizontally mounted pumps

We offer customised pumps with a wide variety of


certificates and approvals. Examples:
Inspection certificate 3.1C
- Lloyds Register of Shipping (LRS)
- Det Norske Veritas (DNV)
ATEX, VIK and UL approvals
Duty-point verification report
Vibration test report.
Further documentation
Information about

39

Belt-driven CR pumps

43

Stainless steel CRN pumps

Horizontally mounted pumps are often chosen in the


following cases:
installations with limited access and space, for
instance cabinets and compact systems
earthquake-prone areas
mobile systems, for instance ships and vehicles.
For installations with limited height, we recommend
horizontally mounted pumps.
For earthquake-prone areas, we recommend
horizontally mounted pumps to lower the centre of
gravity and thus minimise swings during an
earthquake. See the example in fig. 8.

see page

Horizontally mounted CR pumps

Pump parts designed to match your needs


CR pumps with certificates

38
18-63
54

E-pump solutions

59

WebCAPS

165

Supplementary Grundfos pumps

TM03 2645 4705

For installations with special requirements to a


compact design, we recommend CH, CHI pumps or
BM booster modules.
For further information, see page 165.

Fig. 8

Vibrations of pumps in earthquake-prone areas

If the chamber stack and staybolts are stressed by


repeated swings during an earthquake, they may
break and cause stoppage of operation.
For earthquake-prone areas and in mobile systems,
we recommend CRN pumps, as stainless steel is more
ductile than cast iron.

15

CR, CRI, CRN, CRT,

Pumping of liquids down to -40 C


GR7369 -TM02 8470 - TM02 1808

Applications

Special applications

Fig. 9

CRT, CRNE and CRN pumps

Reference applications

Off-shore and maritime applications


cooling applications
deep-well pumping systems
pumps operating under special conditions.

Customised solutions
We offer customised solutions for a number of
applications not mentioned on the previous pages.
Examples:
Off-shore and maritime applications
pumping of liquids down to -40 C
deep-well pumping in small water supply systems
special conditions
special requirements as to approvals, voltage,
frequency.
To ensure a stable and reliable operation, we offer
customised solutions designed to meet your
needs!

16

In applications with liquid temperatures down to


-40 C, the material of shaft seal faces, the dimensions
of the neck ring and other factors must meet high
requirements. At such low temperatures, the selection
of wrong materials and dimensions may cause
deformation because of thermal expansion, and
eventually stoppage of operation.
For liquids below -20 C, we recommend CRN pumps.
Deep-well pumping in small water supply systems
Water is pumped from depths down to 90 metres. The
system consists of a dry-mounted CR pump connected
to a submerged ejector.
Pumps operating under special conditions
Installations at high altitudes (above 1000 metres)
applications with low, high or fluctuating ambient
temperatures
the pumping of high-viscous/-density liquids.
In such cases, the motor may be overloaded and an
oversize motor may be required.
Special requirements
We offer customised pumps meeting special
requirements as to approvals, voltage, frequency, etc.
Further documentation
Information about

see page

CR pumps for cooling applications

36

CR pumps for deep-well pumping

45

CR pumps with under-/oversize motors


Pump parts designed to match your needs

23
18-63

Special installation requirements

15

Off-shore and maritime applications

E-pump solutions

59

In off-shore and maritime applications, pumps must


meet stringent requirements to reliability in connection
with for instance cooling, firefighting, cleaning and
desalination systems. Pumps are often installed in a
corrosive environment.
We offer customised pumps with a wide variety of 3.1C
inspection certificates, such as Lloyds Register of
Shipping (LRS) and Det Norske Veritas (DNV).
For further information, see page 54.
Furthermore, we offer customised pumps with a wide
variety of materials, connections, enclosure classes,
etc.
For the pumping of seawater, we recommend CRT(E)
pumps which have all pump parts in titanium. As its
corrosion resistance is not affected by seawater,
titanium is the ideal solution.

CR pumps with certificates

54

WebCAPS

165

Supplementary Grundfos pumps


If the suction head exceeds 90 metres, we recommend
Grundfos SP and SQ submersible pumps.
For further information about SP and SQ pumps, see
page 165.

CR, CRI, CRN, CRT,

Accessories

6. Accessories
ATEX-approved dry-running
protection

TM05 1120 0611

For environments, group II, category 2G, always use


the ATEX-approved dry-running protection described
below, or a similar product with ATEX approval.
The link between ATEX groups, categories and zones
is explained in the 1999/92/EC directive. Please note
that this is a minimum directive. Some EEC countries
may therefore have stricter local rules. The user or
installer is always responsible for checking that the
group and category of the pump correspond to the
zone classification of the installation site.
Components
Designation

Ex marking

Connection

Flow sensor

II 2G Ex ib IIC T6

G 1/2
AISI316Ti
G 1/2
AISI316Ti

Amplifier for
flow sensor

Product
number

85

96607921

120

96607922

[V]

II (1) GD [Ex ia] IIC

230

96607923

Type

Terminals

II2GEx e IIT6
II 2GEx ia IIC T6
II 2GEx e [ia] IIC T6

Fig. 11 ATEX-approved extension box

The extension box is designed for connection of


intrinsically safe and/or non-intrinsically safe circuits in
explosion-hazardous areas of category 2 (zone 1
and 21).

Venting valve with connecting pipe

GKEI 100 97754528


GKI 60 97754527
GKE 60 97752524

TM05 1160 0611

Extension
box

[C]

TM05 1169 3511

Fig. 12 Venting valve with connecting pipe

Fig. 10 ATEX-approved flow sensor and amplifier

The connecting pipe of this special venting valve


allows the operator to deaerate the pump into a closed
container. This accessory is ideal when pumping
aggressive or hazardous liquids.
Designation

Venting valve with


connecting pipe

Connection

Type

Product
number

G 1/2

EPDM
FKM
FFKM
FXM

97773787
97775104
97775105
97775106

17

CR, CRI, CRN, CRT,

Motor

7. Motor
The Grundfos standard range of motors meets a wide
variety of application demands. For special
applications or operating conditions, we offer various
customised solutions:
a wide range of motor approvals
motors with special voltage
motors with anti-condensation heater
motors with Harting 10-pin multiplug connection
motors with built-in PTC sensor
motors with built-in thermal switch
undersize and oversize motors
motors with alternative enclosure class, etc.

VIK-approved motors
We recommend VIK-approved motors for industrial
climates where aggressive gasses and/or aggressive
vapours, etc., are likely to occur.
The VIK standard applies to three-phase
mains-operated motors and three-phase motors
connected to a frequency converter.
We offer VIK-approved motors from 0.37 to 75 kW in
accordance with the requirements of the German
industrial standard, Verband der Industriellen Energieund Kraftwirtschaft. To comply with the standard,
VIK-approved motors must meet these requirements:
Group II, Category 2, version EEx e or EEx d,
temperature class T3 in the ATEX directive.
In case of doubt, consult the above standard or
contact Grundfos.
Enclosure class IP55 as a minimum.
Protected against sucking. This phenomenon may
occur when the pressure inside the motor is lower
the atmospheric pressure. In such cases, moisture
is sucked from the atmospheric side into the motor
through bearing housings, etc.
From 1.1 to 75 kW, all VIK-approved motors are IE2
high-efficiency motors.
For further information about the VIK-standard, see
www.vik.de or contact Grundfos.

18

Tropicalised motors
A tropicalised motor does not contain paper, wood or
similar materials containing wood pulp.
Grundfos defines a tropicalised motor as a motor
which fulfils the climate group "World-Wide" in
DIN/IEC 721-2-1 and has the following characteristics:
enamel covered windings
double winding impregnation
double winding insulation
FPM V-ring
terminal board made of polyester
liquid sealing between frame and flange/end shield
all outside screws made of stainless steel
30 m paint layer on aluminium stator housings
120 m paint layer on cast-iron stator housings
heating element.

cURus-, UR- and CSA-approved


motors
We offer mains-operated motors with these approvals:
Approval

Motor power - P2 [kW]

cURus

0.37 - 7.5

UR

11 - 75

CSA

11 - 75

Other motor approvals


We offer a wide range of motor approvals:
CCC
C-tick
GOST
B
TSU
METI/JQA
CB
TSE
SASO, etc.

CR, CRI, CRN, CRT,

ATEX-approved pumps

We recommend ATEX-approved pumps for potentially


explosive atmospheres. Explosive atmospheres
consists of air and combustible material, such as
gases, vapours, mists or dusts in which the explosion
spreads after ignition.
We offer explosion-proof or dust-ignition-proof motors
in accordance with the directive 94/9/EC, the so-called
ATEX directive.
The ATEX-approved pumps can be used in areas
(zones) classified according to the directive
1999/92/EC. In case of doubt, consult the
above-mentioned directives or contact Grundfos.
ATEX-approved pumps will be supplied with serial
number, special installation and operating instructions
and a nameplate showing the ATEX classification.
A pump report is available on request.
Scope of ATEX categories

Motor
[kW]

0.37 - 1.3
1.85 - 4.6
5.5 - 7.5
10 - 15
20 - 28

Motors available

All explosion-proof motors have PTC sensors. For


further information about PTC sensors, see page 22.

Special voltage
We offer pumps with the following voltages:
Frequency

50 Hz

60 Hz

Category 2

1999/92/EC 1)
CR pumps available

0.37 - 45

Group II

Pumps intended for use in areas in which


explosive atmospheres are likely to occur.
G (gas)
Zone 1
CR, CRI, CRN, CRT
2G EEx e II T3
2G EEx d II B T4

0.37 - 45

Pumps made of materials that do not


create sparks and thus do not
constitute any danger of explosion.
CR, CRI, CRN
None 1)

Air-driven or hydraulically driven motors are not available from


Grundfos.

Installation areas liable


to be endangered by
explosive atmospheres.

Voltage

Mains-operated motor

Category M2

1)

Version
(2G EExe II T3) (2G EExd IIB T4) (2D T125 ) (3D T125 )

0.37 - 1.5
2.2 - 4
5.5 - 7.5
11 - 45

Group I

Underground installations in mines


liable to be endangered by explosive
gasses or combustible dust.
CR pumps available
Motors available

Motor

TM01 6193 4202

We offer the following ATEX-approved motors:

2)

D (dust)
Zone 21
CR, CRI, CRN, CRT

3
3
3
3
3
3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x
x
x
x
x
x

220-240 /380-415
200-220/346-380 V
380-415 V
380-415 /660-690
200-230/346-400 V
208-230/460 V
220-255 /380-440
220-277 /380-480
220-277 /380-480
380-440 V
380-480 V
380-480 /660-690
575 YV

YV

YV

YV
YV
YV

YV

Motor with integrated frequency converter


50/60 Hz

1 x 200-240 V
3 x 200-240 V
3 x 380-480 V

Note: Other voltages are available on request.

2D 125 C

Category 3
Installation areas liable
to be endangered by
explosive atmospheres.
1999/92/EC 1)
CR pumps available
Motors available

Pumps intended for use in areas in which


explosive atmosphere only rarely occur.
G (gas)
Zone 2
CR, CRI, CRN, CRT
2G EEx e II T3
2G EEx d II B T4

D (dust) 1)
Zone 22
CR, CRI, CRN, CRT
3D 125 C

1)

Note: The link between groups, categories and zones is explained in


the 1999/92/EC directive. Please note that this is a minimum directive.
Some EEC countries may therefore have stricter local rules. The user
or installer is always responsible for checking that the group and
category of the pump correspond to the zone classification of the
installation site.
2)
For group II, category 2 G (zone 1), the pump must be protected
against dry running. Use one of the following methods:
An ATEX-approved dry-running protection.
Always use this protection on pumps with MAGdrive or pumps with
a single mechanical shaft seal.
Pumps with double-seal system (back-to-back or tandem).
The system for pressurising or flushing the double-seal system
must be ATEX-approved.

19

CR, CRI, CRN, CRT,

Motor

Motor with multiplug connection

Dimensions

Gr7550

TM01 8716 0700

129

167

All dimensions are in mm.

Fig. 13 Mains-operated motor with Harting 10-pin


multiplug

TM01 8714 0700

Fig. 17 Dimensions, 1.5 - 7.5 kW

Plug connections

W2 U2

V2

U1

W1

V1

10

TM01 8702 0700

TM01 8713 0700 - TM02 8518 0304

Mains-operated motors fitted with a Harting 10-pin


multiplug connection, HAN 10 ES, enable easy
connection to the mains.
Note: For Grundfos motors with integrated frequency
converter up to 7.5 kW, we offer the solutions shown
on page 20.
The purpose of a multiplug connection is to make the
electrical installation and service of the pump easier.
The multiplug functions as a plug-and-pump device.
The drawings below show the position of the multiplug
on the mains-operated motor.

192
230

Fig. 16 Dimensions, 0.37 - 1.1 kW

Fig. 18 Plug connection from motor

The multiplug connection is available for the following


motor sizes:
Motor power P2 [kW]

Voltage [V], starting method

0.37 - 7.5
0.37 - 7.5

3 x 220-240 /380-415 YV
3 x 380-415 V

Logo for multiplug

L1

L2

L3

10

TM01 8703 0700

Fig. 14 Motor with multiplug connection

Fig. 15 Logo

L1

L2

L3

10

Fig. 20 Plug connection for delta connection

Note: Fishplates for connections are located in the


plug.

20

TM01 8704 0700

TM02 0470 0700

Fig. 19 Plug connection for star connection

CR, CRI, CRN, CRT,

High humidity may cause condensation in the motor.


Slow condensation occurs as a result of a decreasing
ambient temperature; rapid condensation occurs as a
result of shock cooling caused by direct sunlight
followed by rain. We recommend always to use motors
with anti-condensation heater in areas with ambient
temperatures below 0 C.
Note: Rapid condensation is not to be confused with
the phenomenon which occurs when the pressure
inside the motor is lower than the atmospheric
pressure. In such cases, moisture is sucked from the
atmosphere into the motor through bearings, housings
etc.
In applications with constant high humidity levels
above 85 %, the drain holes in the drive-end flange
must be open. This changes the enclosure class to
IP44. If IP55 protection is required due to operation in
dusty environments, we recommend to install a motor
with anti-condensation heater.
The figure below shows a typical circuit of a
three-phase motor with anti-condensation heater.

Fig. 21 Location of the detachable cable inlet bar on the


motor terminal box as well as plugs for mains
connection, sensor and communication

TM03 4058 1406

TM03 1964 3405 - TM03 1962 3405

To facilitate electrical installation and service of our


three-phase CRE pumps up to 7.5 kW, all motor
terminal boxes are equipped with a detachable cable
inlet bar.
When the cable inlet bar is removed, it is possible to
disconnect all electrical connections.
Figure 21 shows the location of the detachable cable
inlet bar on the motor terminal box as well as plugs for
mains connection, sensor and communication.

Fig. 23 Three-phase motor with anti-condensation heater

Key

TM03 2440 4305

Motor with anti-condensation


heater

Symbol

Designation

Contactor

Motor

Note: Connect the anti-condensation heater to the


supply voltage so that it is on when the motor is
switched off.
Motors from 0.37 to 75 kW are available with
anti-condensation heater.
Motor size, 50/60 Hz
[kW]

Fig. 22 Mains-operated motor with anti-condensation


heater

In applications where condensation in the motor may


occur, we recommend to install a motor with an
anti-condensation heater on the stator coil ends.
The heater keeps the motor temperature higher than
the ambient temperature and prevents condensation.

Motor

Plug-and-pump solutions for CRE pumps

2-pole

4-pole

1 x 24 V

0.37 - 1.1
1.5 - 3.0
4.0 - 5.5

0.25 - 0.75
1.1 - 3.0
4.0

38

7.5 - 22
30-37
45 - 55
75
1)

Power of heating unit


[W]

5.5 - 15
18.5 1)
-

1)

1 x 115 V

2 x 38
-

1 x 190-250 V
23
31
38
2 x 38

55

55

92
109

92
109

15 and 18.5 kW 4-pole are oversize motors in the CR pump range.

21

CR, CRI, CRN, CRT,

Key

Fig. 24 PTC sensor incorporated in winding

Built-in PTC sensors (thermistors) protect the motor


against rapid as well as steady overload.
We offer motors with temperature-controlled PTC
sensors in the motor windings.
Three-phase mains-operated motors from 3 kW and up
have PTC sensors as standard.
Note: Temperature-controlled PTC sensors must be
connected to an external tripping or LiqTec unit
connected to the control circuit. For further information
about LiqTec, see page 48.
Protection according to IEC 60034-11:
TP 111 (steady overload only)
TP 211 (steady and rapid overload).
PTC sensors comply with DIN 44 082. Maximum
voltage at the terminals, Umax = 2.5 VDC. All tripping
units available for DIN 44 082 PTC sensors meet this
requirement.
The figure below shows a typical circuit of a
three-phase motor with PTC sensors.
L1 L2 L3 N

3UN2 100-0 C
95

A1
H1
H2
K

N
T1

T2

A2

96

98

Symbol

Designation

S1

On/off switch

K1

Contactor

+T

PTC sensor (thermistor) in motor

Motor

3UN2 100-0 C

Tripping unit with automatic reset

Amplifier

Output relay

H1

LED Ready

H2

LED Tripped

A1, A2

Connection for control voltage

T1, T2

Connection for PTC sensor loop

Motors with thermal switches

TM02 7042 2403

TM02 7038 2403

Motor

Motors with PTC sensors

Fig. 26 Thermal switch incorporated in winding

Built-in thermal switches protect the motor against


rapid as well as steady overload.
We offer three-phase mains-operated motors from
0.37 to 11 kW with built-in thermal switches.
Note: Thermal switches must be connected to an
external control circuit to protect the motor against
steady overload. The thermal switches require no
tripping unit.
Protection according to IEC 60034-11: TP 211 (steady
and rapid overload). As protection against seizure, the
motor must be connected to a motor-protective circuit
breaker.
Thermal switches tolerate the following maximum
loads:

S1

K1

M
3

Fig. 25 Three-phase motor with PTC sensors

22

TM00 3965 1494

K1

Umax

250 VAC

IN

1.5 A

Imax

5.0 A (locked-rotor and breaking current)

CR, CRI, CRN, CRT,

Motor

Oversize motors

Figure 27 below shows a typical circuit of a


three-phase motor with built-in bimetallic thermal
switches.

We recommend to use an oversize motor if operating


conditions fall outside the operating conditions
described in these data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CR, CRN high pressure
CRT, CRTE.
We especially recommend oversize motors in these
cases:
The pump is installed at an altitude above 3500 m
(MG IE3), 2875 m (Siemens IE3), and 1000 m
(MG IE2).
The ambient temperature exceeds +60 C (MG IE3),
+55 C (Siemens IE3) or +40 C (MG IE2).
The viscosity or density of the pumped liquid is
higher than that of water.
We offer the following oversize motors.

TM00 3964 1494

Mains-operated motors

Fig. 27 Three-phase motor with thermal switches

Key
Symbol

Designation

S1

On/off switch

K1

Contactor

Thermal switch in motor

Motor

MV

Motor-protective circuit breaker

Oversize motors (three-phase)


2-pole
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0

4-pole
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5

Motors with integrated frequency converter


Oversize motors (three-phase)
2-pole
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0

4-pole
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5

23

CR, CRI, CRN, CRT,

Motor

Undersize motors

Motor sizes available for pumps

We recommend to use an undersize motor if operating


conditions fall much inside the standard conditions
described in these data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CR, CRN high pressure
CRT, CRTE.
We especially recommend undersize motors in these
cases:
The viscosity or density is lower than that of water.
The duty point of the pump is constant, and the flow
rate is significantly lower than the maximum
recommended flow rate.
We offer the following undersize motors.

2-pole

Mains-operated motors
Undersize motors (three-phase)
2-pole
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0

4-pole
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5

Motors with integrated frequency converter


Undersize motors (three-phase)
2-pole
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5

24

4-pole
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0

Undersize motor

Oversize motor

[kW]

[kW]

0.37
0.37
1.5
7.5

7.5
18.5
45
75

Undersize motor

Oversize motor

[kW]

[kW]

0.25
0.25
1.5
1.5

1.5
4.0
11
18.5

Pump type
CR
CR
CR
CR

1s - CR 5
10 - CR 20
32 - CR 90
120 - CR 150

4-pole
Pump type
CR
CR
CR
CR

1s - CR 5
10 - CR 20
32 - CR 90
120 - CR 150

CR, CRI, CRN, CRT,

4-pole motors

IP class

IP54

IP55

IP56

IP65

TM03 1711 2805

The motor enclosure class complies with IEC 60034-5.


The enclosure class states the degrees of protection of
the motor against ingress of solid objects and water.
All motors comply with IP55 as standard.
On request, we offer motors in accordance with IP54
and IP65.
Description
The motor is protected against the ingress of dust,
i.e. harmful layers of dust.
The motor is protected against water splashing from
any direction.
The motor is protected against the ingress of dust,
i.e. harmful layers of dust.
The motor is protected against water being
projected by a nozzle from any direction.
The motor is protected against the ingress of dust.
The motor is protected against heavy seas or
high-pressure water jets from any direction.
The motor is completely dust-proof.
The motor is protected against water being
projected by a nozzle from any direction.

Motor

Alternative enclosure class (IP)

Fig. 29 4-pole motor

We offer all CR pumps with 4-pole motors.


4-pole motors are often preferred in these cases:
A low sound pressure level is required.
Inlet conditions are poor.
Beating of the liquid is not allowed.
Performance curves and technical data of 4-pole
CR pumps, see page 110 to 136 and 123 to 136.
Electrical data of 4-pole CR pumps, see pages 160
and 161.

Alternative terminal box positions

Position
6 oclock
(standard)

Position
9 oclock

Position
12 oclock

Fig. 28 Possible terminal box positions

Position
3 oclock

TM03 3658 0606

The terminal box is in position 6 oclock as standard.


The possible terminal box positions are shown below.

Motor efficiency classes


The new EN standard 60034-30:2009 defines the
following efficiency classes of low-voltage three-phase
asynchronous motors from 0.75 to 375 kW:
IE1: standard efficiency
IE2: high efficiency
IE3: premium efficiency.
IE = International Efficiency.
Three-phase motors of CR pumps are 0.75 to 75 kW
IE3 motors as standard.
CR pumps with IE2 motors are available on request.

Other motor makes


We also offer pumps with a motor of any make which
can fulfil requirements such as
flange dimensions
bearing specifications
pump shaft.
Alternatively, Grundfos pumps can be supplied without
a motor.

25

CR, CRI, CRN, CRT,

Shaft seals

8. Shaft seals
Shaft seal arrangements

Shaft seal variants

Depending on the application, CR pumps are available


with these shaft seals:
single seal arrangement
double seal arrangement
magnetic drive.
CR(E), CRI(E), CRN(E) pumps are fitted with a
cartridge shaft seal mounted in a single seal
arrangement as standard:
HQQE or HQQV (0.25 - 45 kW)
HBQE or HBQV (55 - 75 kW).
CRT(E) are fitted with one AUUE or AUUV O-ring seal
as standard.
In applications where the pumped liquid may harm the
environment, double seal arrangements or
magnetic-drive pumps are selected.
To ensure reliability, these conditions must be
considered when selecting a shaft seal:
operating pressure
type of pumped liquid
liquid temperature.

Liquids or applications exceeding the range of normal


operating conditions require special-purpose shaft seal
solutions.
In order to meet any specific requirements, we offer
variants of seal face material and secondary seal
material (rubber parts).
The following tables apply to clean water and water
containing glycol.
Shaft seal and seal face variants

Pump type

CR(E), CRI(E),
CRN(E)

CRT(E)

Temperature
[C]

Shaft seal,
seal face
variant

Min.

Max.

HQQx

-40

+120

30

HBQx *)
HQBx

+120

30

+120

30

HUUx

-40

+90

30

HUBx

+120

30

Pressure
rating
[bar]

AQQx

-40

+90

25

DQQx

-40

+90

25

*) Only for CR, CRN 120 and 150, 55-75 kW.

Overview of shaft seals


The below table shows the shaft seals available.
Shaft seal
As standard

On request

CR(E), CRI(E) and CRN(E)


HQQE
HQQV

HBQE *)
HBQV *)

HQQE *)
HQQV *)
HUBE
HUBV
HUUE
HUUV
HUUK
HUUF
HUBF
HUBK
HQQK
HQQF
HQBE
HQBV
HQBK
KUHE
KUHV
KUUV
KUUE

CRT(E)

AUUE
AUUV

*) Only for CR, CRN 120 and 150, 55-75 kW.

Codes for shaft seals, see page 9.

26

AUUK
AQQE
AQQV
AQQK
DQQE
DQQV
DQQK

For explanation of codes, shaft seal types and


materials, see the type key on page 9, or see the data
booklet "Shaft seals" which is available in WebCAPS.

CR, CRI, CRN, CRT,

We recommend shaft seals with EPDM O-ring material


for water and aqueous solutions.
EPDM rubber is not resistant to mineral oils.
Temperature range for rubber material:
heat-resistant from -40 C to +150 C
water-resistant up to +140 C.
Shaft seals with FKM O-ring material (HxxV)
We recommend shaft seals with FKM O-ring material
for a wide range of temperatures and pumped liquids,
such as acids, saline solutions, mineral oil, vegetable
oil and most solvents.
Temperature range for rubber material:
heat-resistant from -20 C to +240 C (oil only)
water-resistant up to +90 C.
Shaft seals with FFKM O-ring material (HxxK)
We recommend shaft seals with FFKM O-ring material
for a wide range of pumped liquids, such as nitric acid,
solvents, varnishes, paints and dyes.
Temperature range for rubber material:
heat-resistant from -20 C to +150 C
water-resistant up to +150 C.

Double seal arrangements

Shaft seals

Shaft seals with EPDM O-ring material (HxxE)

We offer two double seal arrangements:


back-to-back (OQQx)
tandem (PQQx).

Back-to-back seal arrangement


Back-to-back seal arrangements consist of two
Grundfos cartridge shaft seals, type O, fitted
back-to-back in a separate seal chamber.
We recommend this type of seal arrangement for
handling these types of liquid:
toxic, aggressive or flammable liquids
abrasive or sticky liquids which would either wear
out, damage or block a mechanical shaft seal.
The back-to-back double seal protects the surrounding
environment and the people working in the vicinity of
the pump. It is specially designed for operating
pressures up to 25 bar and +120 C with the aim of
minimising the risk of leakage from the pump to the
environment.

We recommend shaft seals with FXM O-ring material


for high temperatures as well as for acid liquids and
gasses within oil and gas extraction.
Temperature range for rubber material:
-10 C to +275 C. For short periods up to +300 C.
Plug and sleeve O-rings made of FXM are available for
the full range.
For further information about O-ring materials, see the
following data booklets available in WebCAPS.
Publication number
V7023751

CR, CRI, CRN, CRE, CRIE, CRNE, 60 Hz

96488672

CRT, CRTE

V7149894

Shaft seals

96519875

TM04 4405 1609

CR, CRI, CRN, CRE, CRIE, CRNE, 50 Hz

Fig. 30 CR 1s to 5 with back-to-back seal arrangement

Fig. 31 CR 10 to 20 with back-to-back seal arrangement

TM04 4267 1609

Data booklet

TM04 4404 1609

Shaft seals with FXM O-ring material (HxxF)

Fig. 32 CR 32 to 90 with back-to-back seal arrangement

27

CR, CRI, CRN, CRT,

TM03 3810 1106

TM04 4406 1609

Shaft seals
Fig. 33 CR 120 and 150 with back-to-back seal
arrangement

Key to figures 30, 31, 32 and 33


Fig. 34 CR pump with dosing pump
Pos.

Designation

Seal chamber

Shaft seals

Pump

Key
Pos.

The back-to-back seal arrangement is available for the


following CR pumps:
Pump
type

1s

CR(E)

CRI(E)

CRN(E)

10

15

20

32

45

64

90

120

150

Available.

Dimensions
All dimensions are in mm.
Pump type

Additional height of seal chamber

CRI, CRN 1s, 1, 3, 5

108

Designation

Pump

Pressure tank

Dosing pump

Pressure switch

Manometer

Reservoir with barrier liquid

The setpoint of the barrier liquid pressure is set by


means of the pressure switch (pos. 4). When the
pressure drops below the setpoint, the dosing pump
will start and thus maintain a higher pressure in the
seal chamber (max. pressure 16 bar). Barrier liquid is
supplied from a reservoir (pos. 6).
One dosing pump can supply several pumps with
back-to-back seal arrangements.
Connections are all RG 1/2".
Note: Connecting pipes/hoses are not included.

CRI, CRN 10, 15, 20

90

CR, CRN 32

210

CR, CRN 45

240

Dimensions of back plate with components

CR, CRN 64

166

All dimensions are in mm.

CR, CRN 90

184

CR, CRN 120, 150

111

Pressurising

TM03 4660 2406

In back-to-back seal arrangements, the pressure in the


seal chamber must be higher than the pump pressure
to prevent the pumped liquid from leaking through the
shaft seal to the environment.
Note: The barrier liquid will seep through the lower
(primary) shaft seal and be mixed with the pumped
liquid. The right barrier liquid must therefore be used.
The pressure in the seal chamber can be generated in
three ways:
by an existing pressure source
by a dosing pump
by a pressure intensifier.
For further information about Grundfos back-to-back
seal arrangements, see the data booklet "Shaft seals"
which is available in WebCAPS.
CR pump with dosing pump
The example below shows a CR pump with a
back-to-back seal arrangement. The barrier liquid is
supplied and pressurised by a dosing pump.

28

Fig. 35 Dimensional sketch

CR, CRI, CRN, CRT,

CR pump with pressure intensifier

Shaft seals

Note: One pressure intensifier can only supply one


pump. The pressure intensifier is fitted on the pump
from factory.
Maximum operating pressure: 25 bar.
Dimensions

GR5954

All dimensions are in mm.

TM01 4459 0399

Fig. 36 CR pump with pressure intensifier


8

Fig. 38 Dimensional sketch


6
Pump type

3
2
1

CR, CRI, CRN 1, 3, 5

297

108

128

CR, CRI, CRN 10, 15, 20

330

90

140

CR, CRN 32

342

210

155

CR, CRN 45

349

240

164

CR, CRN 64

349

166

164

CR, CRN 90

355

184

170

CR, CRN 120, 150

355

111

170

Note: The dimension "b" is the additional height as compared to the


standard pump.

TM03 8299 1007

Fig. 37 Components of pressure intensifier


Pos.

Designation

Pressure intensifier

Piston

Diaphragm

Non-return valve

Relief valve

Vent screw, Rp 1/8

Spring for piston

Pressure gauge (barrier liquid)

Pressure gauge (pumped liquid)

The seal chamber is primed with barrier liquid via a


non-return valve (pos. 4) until the pressure gauge
(pos. 8) reaches 1.5 to 2 bar. The spring (pos. 7) is
now preloaded with the barrier liquid pressure. The
pump is primed and vented. When the pump is started,
the pump pressure + the pressure from the preloaded
spring will result in a pressure 1.5 to 2 bar higher in the
seal chamber.

29

CR, CRI, CRN, CRT,

Shaft seals

Tandem seal arrangement

Key

Tandem seal arrangements consist of two Grundfos


cartridge shaft seals, type P, mounted tandem in a
separate seal chamber.
We recommend tandem seals for crystallising,
hardening or sticky liquids.

Pos.

Designation

Seal chamber

Shaft seals

Pump

The tandem type of seal is available for these CR


pumps:

CR 1s, 1, 3, 5, 10, 15 and 20

Pump
type

1s

10

15

20

32

45

64

90

120

150

CR(E)

CRI(E)

CRN(E)

TM03 3657 0606

Available.

Fig. 39 CR 1s to 20 with tandem seal arrangement

Dimensions
All dimensions are in mm.
Pump type

Additional height of seal chamber

CRI, CRN 1s, 1, 3, 5

108

CRI, CRN 10, 15, 20

90

CR, CRN 32, 45, 64, 90

CR 32, 45, 64 and 90

CR, CRN 120, 150

0
111

TM03 9158 3507

Flushing-liquid systems

Fig. 40 CR 32 to 90 with tandem seal arrangement

TM04 4164 1609

CR 120 and 150

CR pumps with tandem seal arrangement must be


equipped with a flushing-liquid system.
Note: The pumped liquid will seep through the lower
(primary) shaft seal and be mixed with the flushing
liquid. Maximum liquid temperature: +120 C.
The flushing-liquid flow rate should also be matched to
the application (recommended flow rate 25-200 l/h).
The pressure of the flushing liquid must always be
lower than the pressure of the pumped liquid.
Note: The flushing-liquid supply must never be
connected directly to the public water supply system.
Local regulations must be observed.
For further information about Grundfos tandem seal
arrangements, see the data booklet "Shaft seals"
which is available in WebCAPS.
The following figures show examples of flushing
systems for tandem seal arrangements.

Minimum
1 metre
TM04 3217 2408

Fig. 41 CR 120 and 150 with tandem seal arrangement

Fig. 42 Tandem seal arrangement with circulating flushing


liquid

30

CR, CRI, CRN, CRT,

Shaft seals

CR with air-cooled top

In figure 42, the flushing liquid circulates between an


elevated tank and the pump by natural circulation.
Heated flushing liquid rises from the seal chamber to
the tank where it cools down. The cooled-down
flushing liquid returns to the seal chamber.
At high temperatures, the circulation of flushed liquid
through the seal chamber cools the seal faces of the
shaft seal and reduces noise.

Fig. 43 Tandem seal arrangement with flushing-liquid


supply

In figure 43, the flushing liquid enters the seal chamber


via a pipe from an elevated tank.
No heat is dissipated from the system.

GR5228

TM03 3809 1106

CR pumps with an air-cooled top are used where the


pumping of hot liquids is crucial for a successful
production. A CR pump with an air-cooled top is a
pump with a special air-cooled shaft seal chamber
generating the same insulation effect as that of a
vacuum flask. No external cooling is necessary; the
ambient temperature is sufficient.

Fig. 45 CR pump with an air-cooled top

CR pumps with air-cooled top have a mechanical


silicon carbide/silicon carbide/EPDM cartridge shaft
seal, type HQQE, as standard.
The pumps are able to handle liquid temperatures up
to +180 C at max. PN 25.
Note: If the pumped liquid is oil, the pumps can handle
following liquid temperatures:
CR 1s to 90:
+240 C at max. PN 16.
CR 120 and 150: +180 C at max. PN 16.
The following rubber part variants are available for our
air-cooled top solutions:
Liquid temperature [C]

Rubber part material

TM03 3813 1106

Water-based liquids

Fig. 44 Tandem seal arrangement with flushing liquid


connected to a drain

In figure 44, the flushing liquid enters the seal chamber


via a pipe from an elevated tank.
In case of leakage, the pumped liquid is washed away
to the drain by the flushing liquid.

120-150

EPDM

120-180

FXM/EPDM

Thermal oils
120-240

FKM

Temperatures above +120 C normally result in a


substantial reduction of seal life due to poor lubrication
of the seal faces. As the temperature in the seal
chamber does not exceed +120 C during operation, a
standard Grundfos shaft seal can be used.
An automatic air vent is required for venting the pump
seal chamber.
Note: For safety reasons, fit a pipe in order to lead
away steam from the air vent to a drain.
Local regulations must be observed.

31

CR, CRI, CRN, CRT,

Fig. 46 CR 1s, 1, 3 and 5 with air-cooled top

TM04 4165 0909

CR 120 and 150

TM03 9159 3507

Shaft seals

CR 1s, 1, 3 and 5

Fig. 49 CR 120 and 150 with air-cooled top

Key

CR 10, 15 and 20

Pos.

Designation

Air chamber

Liquid

Air vent

Shaft seal

Cooling channel

Pump range

TM03 9160 3507

The air-cooled top is available for these pump types:

Fig. 47 CR 10, 15 and 20 with air-cooled top

Pump
type

CR pumps with air-cooled top


1s

10

15

20

CR(E)
CRI(E)

CRN(E)

32

45

64

90

120

150

Available.

CR 32, 45, 64 and 90

Note: CRT(E) pumps are not available with air-cooled


top.
Bearing flanges for CR pumps with air-cooled top

TM03 4060 1406

When pumping hot liquids, the pump requires a net


positive inlet pressure according to the vapour
pressure of the specific liquid.
For water applications at 180 C, a bearing flange is
incorporated in the following pump types.

Fig. 48 CR 32, 45, 64 and 90 with air-cooled top

50 Hz

60 Hz

CRI, CRN 10-1 - 10-6


CRI, CRN 15-1 - 15-3
CRI, CRN 20-1 - 20-3
CR, CRN 32-1-1 - 32-4
CR, CRN 45-1-1 - 45-2
CR, CRN 64-1-1 - 64-2-2
CR, CRN 90-1-1 - 90-1

CRI, CRN 10-1 - 10-5


CRI, CRN 15-1 - 15-2
CRI, CRN 20-1
CR, CRN 32-1 - 32-2
CR, CRN 45-1-1 - 45-1
CR, CRN 64-1-1

Note: A bearing flange is not available for motors


below 3 kW. Some CR, CRN 32 pumps come with
oversized motors.

32

Air vent positions on CR pumps with air-cooled top

Shaft seals

CR, CRI, CRN, CRT,

Horizontal CR pumps with air-cooled top

TM03 4084 1609

The air vent of vertical CR pumps with air-cooled top is


in line with the discharge port (12 oclock position) as
standard. The air vent is mounted vertically (12 oclock
position) on horizontal pumps.
The possible air vent positions are shown below.
Vertical CR pumps with air-cooled top
Fig. 52 Air vent positions on horizontal CR pumps with
air-cooled top

Key to fig. 52
Pump type

12 oclock

TM03 3659 0606

3 oclock

6 oclock

CRI, CRN 1s, 1, 3, 5


CRI, CRN 10, 15, 20
CR, CRN 32
CR, CRN 45, 64
CR, CRN 90, 120, 150

X
308
324
391
398
404

Note: 75 kW motors are higher than distance x.

Fig. 50 Air vent positions on vertical CR pumps

Dimensions

TM03 4082 1609

All dimensions are in mm.

Fig. 51 Air-cooled top


Pump type

CRI, CRN 1s, 1, 3, 5 (< 3 kW)

142

CRI, CRN 1s, 1, 3, 5 (3 - 7.5 kW)

172

CRI, CRN 10, 15, 20 (< 4 kW)

156

CRI, CRN 10, 15, 20 (4 - 7.5 kW)

186

CRI, CRN 10, 15, 20 (11 - 18.5 kW)

217

CR, CRN 32

176

CR, CRN 45, 64

186

CR, CRN 90

190

CR, CRN 120, 150 (11 - 45 kW)

190

CR, CRN 120, 150 (55 - 75 kW)

243

Additional pump height


Pump type
CRI, CRN 1, 3, 5

Additional pump height


108

CRI, CRN 10, 15, 20

90

CR, CRN 32

210

CR, CRN 45

240

CR, CRN 64

166

CR, CRN 90

184

CR, CRN 120, 150

111

33

CR, CRI, CRN, CRT,

Shaft seals

Magnetic-drive pump (MAGdrive)

Applications

Grundfos CRN MAGdrive pumps operate according to


a patented, magnetic-drive system that eliminates the
need for shaft seals. The power from the motor is
transmitted to the pump by magnetic force and not by
a conventional coupling. Combined with a hermetically
sealed liquid end, the pump is totally leak-free.
As all axial forces are absorbed in the MAGdrive
system, the pump incorporates a standard ICE or
NEMA motor with keyway and deep-groove ball
bearing.

The CRN MAGdrive pump is suitable for wide selection


of industrial applications such as:
Aggressive or corrosive liquids
Concentrated sulphuric acid, nitric acid, phosphoric
acid, etc.
Toxic liquids
Trichloroethylene, chloroform, phenol, etc.
Flammable liquids
Petrol, jet fuels, LPG, alcohols, etc.
Hardening/curing liquids
Paint, glue, resins, etc.
Crystallising liquids
Glycol additives, naphthalene, sugar products,
salts, etc.
Refrigerants
Ammonia, synthetic chemicals (CFC, HCFC, HCF),
etc.

GrA4445

Design

TM03 9149 3407

Fig. 53 CRN MAGdrive pumps

The MAGdrive solution is available for these pumps:


CRN pumps with magnetic drive
Pump type
CRN(E)

1s

10

15

20

32

45

64

90

Available.
* Available up to 22 kW.

As minimum, a soft starter is required for these motors:


2-pole motors: 18.5 and 22 kW.
4-pole motors: 1.1 kW and up.
Features and benefits
CRN MAGdrive offers the following special features
and benefits:
a hermetically sealed drive system for 100 %
leak-free pump operation
special choice of materials and design for low
energy loss
simple pump design for ease of service
unique pump design for efficient cooling of magnet
by means of the pumped liquid
ATEX version available.

Fig. 54 MAGdrive system


Pos.

Designation

Materials

1
2
3

Motor stool
MAGdrive
Pump head

Cast iron. Stainless steel on request

The configuration of the CRN MAGdrive pump is


almost identical to that of the standard CRN pump.
The following rubber parts solutions are available:
EPDM
FXM (Fluoraz)
FFKM (Kalrez)
FKM (Viton).
Connections available for CRN MAGdrive pumps:
CRN
Connection type
1s, 1, 3, 5, 10, 15, 20

32, 45, 64, 90

DIN, ANSI, JIS flange

PJE

FlexiClamp, union, oval


flange, TriClamp

Available.

34

Stainless steel (EN 1.4408)

Construction

Operating conditions

The magnetic field is generated by two magnets; the


outer magnet is driven by the motor, and the inner
magnet is connected to the pump. The two shafts are
not connected.

Maximum pressure: 25 bar.


Temperature range: -40 C to +120 C.
Viscosity range: 0.3 to 300 mPas.

Shaft seals

CR, CRI, CRN, CRT,

Technical data
Motor range: 0.37 kW to 22 kW.
Dimensions

TM03 9141 3407

The height of the MAGdrive system typically makes the


pump a little higher than a standard CRN pump. Some
pump sizes have a larger motor than the standard
range.
For dimensions and weights for CRN MAGdrive
pumps, see page 139 to 152.
Note: When ordering a Grundfos MAGdrive, please
state the data:
liquid temperature [C]
liquid viscosity [mPas]
liquid density [kg/m3]
frequency [Hz].
Above information is required for the selection of the
correct MAGdrive/motor combination.

Fig. 55 Sectional drawing of MAGdrive system


Pos. Designation

Material

1
2
3
4
5

Outer drive
Outer magnets
Can
Inner drive
Inner magnets

1.4301
NdFeB (neodymium)
1.4539
1.4401
NdFeB (neodymium)

Rotating thrust bearing

SiC Q1G (silicon carbide,


carbon-filled)

Stationary thrust
bearing

Radial bearing

Upthrust bearing

10

Drive/pump shaft

11
12

Pump head
O-ring

SiC Q1G (silicon carbide,


carbon-filled)
SiC (silicon carbide)
Graflon (carbon-graphite-filled
PTFE)
CRN 1s-5
: 1.4401
CRN 10-20 : 1.4460
CRN 32-90 : 1.4462
1.4408
EPDM, FKM, FXM, FFKM

35

CR, CRI, CRN, CRT,

Pump

9. Pump
PN 25 and PN 40 pumps

We offer these pump types with tappings:

We offer customised pump solutions for the following


inlet pressures:
CR 1 to CR 20:
up to 25 bar.
CR 32 to CR 150: up to 40 bar.
Note: In applications with high inlet pressures, a
bearing flange must be fitted.
For further information, see the CR, CRN
high-pressure data booklet
(publication number V7174003).

Pump
type

1s

10

15

20

CR(E)

CRI(E)

CRN(E)

32

45

64

90

120

150

Available.

Note: CR(E) and CRN(E) 32, 45, 64 and 90 have


tappings for measurement of pump inlet pressure as
standard.

Measurement of inlet pressure

Pumping of liquids down to -40 C

As CR 1s to CR 20 pumps are not equipped with a


connection for the measurement of pump inlet
pressure, we offer customised pumps with a tapping
for a pressure gauge or pressure sensor.

We offer customised pumps for the pumping of liquids


down to -40 C. The pumps have an oversize neck ring
ensuring that impellers do not seize up as a result of
thermal expansion.
We offer the above solution for these pump types:

TM03 4726 2506

Pump
type

TM03 4091 1606

Fig. 56 CR pump with pressure gauge

Fig. 57 Insert for measurement of inlet pressure

The material of the insert is stainless steel (AISI 316).


Designation

Rubber
material

Connection

L
[mm]

Product
number

CR 1s, 1, 3, 5
EPDM
FKM
FFKM
FXM

RG 1/4

57

96488082
96562250
96562251
96562252

CRI, CRN 1s, 1, 3, 5


Insert for
measurement of
inlet pressure

EPDM
FKM
FFKM
FXM

RG 1/4

51.5

96562253
96562254
96562255
96562256

CR 10, 15, 20
EPDM
FKM

RG 1/4

62

96584117
96584119

CRI, CRN 10, 15, 20


EPDM
FKM

36

RG 1/4

53

96584121
96584122

1s

10

15

20

32

45

64

90

120

150

CR(E)
CRI(E)

CRN(E)

Available.
Standard CRN 32, 45, 64 and 90 pumps with shaft seal type HQQE are
suitable for liquid temperatures down to -40 C.

CR, CRI, CRN, CRT,

Surface treatment
Cleaned and dried pumps
Cleaned and dried pumps are used in applications
involving strict demands to cleanliness and surface
quality, such as low content of silicone.
To meet these strict demands, we offer these cleaned
dried pump types:
Pump
type

1s

CR(E)

CRI(E)

CRN(E)

10

15

20

32

45

64

90

120

150

Pump

Carbon-free pumps
Certain processes, such as pumping of pure water in
electronics industries, require pumps that do not
contain carbon.
To meet such requirements, we offer these 100 %
carbon-free pump types:
Pump
type

1s

CR(E)

CRI(E)

CRN(E)

10

15

20

32

45

64

90 120 150

Available.
Pumps with HQQx shaft seal are carbon-free as standard.

Available.

Prior to assembly, all pump parts are cleaned in 60 to


70 C water with a cleaning agent. All pump parts are
then thoroughly rinsed in de-ionised water and
air-dried. The pump is assembled without any use of
silicone lubricants. Finally, the pump is packed in
silicone-free plastic.
Note: Silicone-free shaft seals are available as option.
Cleaned and dried pumps are not performance tested.
Electropolished pumps
Electropolished pumps are often used in the
pharmaceutical industry and in the food and beverage
industry where materials and surface quality must
meet strict requirements to hygiene or corrosion
resistance.
Electropolishing removes burrs as well as metallic and
non-metallic inclusions, providing a smooth, clean and
corrosion-resistant stainless steel surface.
First all components are pickled in a mixture of nitric
and hydrofluoric acid. Subsequently, the components
are electropolished in a mixture of sulphuric and
phosphoric acid. Finally, the components are
passivated in nitric acid.
All cast parts of CRN are polished mechanically before
being electropolished.
Note: The pump incorporates a standard shaft seal
which has not been polished.
To meet the strict hygienic requirements to material
and surface quality, we offer electropolished stainless
steel pumps with the following surface quality:

Corrosion protection
We offer corrosion protection in the form of painting
and in several categories according to the specific
requirements of the pump installation.
The categories refer to area/environment, layer
thickness and lifetime expectancy.
The new DS/EN ISO standard 12944 divides the
categories into three validity periods:
Low:
2 to 5 years
Medium: 5 to 15 years
High:
more than 15 years
Corrosion protection will be according to the standard
GS 704B0001.
Alternative colouring
We offer customised pumps in any NCS- or
RAL-specified colour to suit your requirements!
The used paint is water-based. Painted parts
correspond to corrosion class III.
All pump types and sizes are available with alternative
colouring.

Cast stainless Stainless-steel Surface


steel
parts (not cast) quality

Pump type
CRN 1s, 1, 3, 5,
10, 15, 20, 32, 45,
64, 90, 120, 150

Ra 0.8 m

Available.

We offer these electropolished pumps:


Pump
type

1s

10

15

20

32

45

64

90

120

150

CR(E)
CRI(E)
CRN(E)

Available.

37

CR, CRI, CRN, CRT,

Pump

CRN all-stainless steel pumps

Pump range

We offer customised stainless-steel CRN pumps for


maritime applications, very humid environments, etc.:
pump with stainless-steel motor stool
pump with stainless-steel base
pump with stainless-steel flanges.
We offer the above solutions for these pump types:
Pump
type

10

15

20

32

45

64

90

120

150

CRI(E)

*)

*)

Note: The dimensions of customised stainless-steel


CRN pumps do not differ from those of standard CRN
pumps.

CR low NPSH

TM03 4063 1406

Cavitation is often a problem in applications where


pumps have to deal with the combination of high liquid
temperatures, poor inlet pressure and/or high flow
rate. For further information about NPSH and the
calculation of NPSH value, see these data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CR, CRN high pressure
CRT, CRTE.
Low-NPSH pumps are designed to eliminate the risk of
cavitation and ensure a stable and reliable operation.
The CR low-NPSH pump is a pump with a special
first-stage design that reduces the pumps NPSH value
and prevents erosion and destruction of the pump,
pipework and valves. Thanks to the improved inlet
design, low-NPSH pumps can handle more stress than
conventional pumps without affecting the stability of
operation.
The CR low-NPSH pump reduces the excess pressure
itself and does not require any additional tank to
provide supplementary pressure. In boiler feed
applications where many large tanks are gathered, a
compact system is an advantage.

Fig. 58 Sectional drawing of CR low-NPSH pump

Key

38

CR low-NPSH pumps
5

10

15

20

32

45

64

CR(E)

CRI(E)

CRN(E)

1s

90

120

Maximum pressure

25 bar

Maximum liquid temperature

+120 C 1)

1)

Available.
*)Only available with stainless steel base and flanges.

Pos.

Pump
type

150

Available.
1s

CR(E)
CRN(E)

These pump types are available as low-NPSH pumps:

Designation

Special inlet part

Special inlet impeller

With air-cooled top, the maximum liquid temperature is +180 C.

For further information about CR low-NPSH pumps,


see pages 70 to 85.
For information about sectional drawings, dimensions
and weights, see pages 110 to 122.

CR, CRI, CRN, CRT,

Horizontal inline pumps

Pump

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW)


CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW)

GR5379

B1

Fig. 59 Horizontal CR pump


X

2 x 14

AAA
AA
A
4 x 14

TM03 4642 3507

AB

BB
B

Horizontal pumps are used in applications for safety


and/or space-saving reasons.
In earthquake areas, horizontal pumps are more
reliable than vertical pumps. In case of earthquake, the
design and mounting of the pump will dampen the
oscillations of the pump.
In installations with limited access or space, we
recommend horizontal pumps to improve installation
and service.

CR(E), CRN(E) 32, 45, 64, 90, 120, 150

Pump range
These Grundfos pumps are available for horizontal
mounting:
Horizontal CR pumps

Pump
type

1s

10

15

20

32

45

64

90

120

150

CR(E)

CRI(E)

CRN(E)

Available.

CRT(E) 2, 4, 8 and 16 pumps are also available for


horizontal mounting. The pumps are supplied with
separate mounting plates for support of motor and
pump.
Dimensional drawings
CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW)
CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW)

B1

2 x 14

B
B

TM05 1537 2911

2 x 14

TM03 4641 3507

39

CR, CRI, CRN, CRT,

Pump

Dimensions
All dimensions are in mm.
CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW), support
for base plate and pump head
X
Connections
Motor
[kW]

0.37-0.55
0.75-1.1
1.5-2.2
3-4

138

C
B1-118
B1-124
B1-140
B1-144

45
45
45
45

140

50

DIN

Oval, PJE,
FlexiClamp

105

80

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW)


CR(E), CRI(E), CRN(E) 5
X
Connections

Motor
[kW]

5.5
7.5

216
216

AA
326
326

AAA

AB

366
366

276
276

140
140

BB
180
180

B1+119
B1+119

68
68

E
45
45

F
138
138

200
200

50
50

DIN

Oval

105

80

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW), support for base plate and pump head
CR(E), CRI(E), CRN(E)
10

15, 20
X
Connections

Motor
[kW]

0.37-0.55
0.75-1.1
1.5-2.2
3-4

170

B1-125
B1-129
B1-144.5
B1-149.5

45
45
45
45

174

DIN, oval, PJE, FlexiClamp

DIN, oval, PJE, FlexiClamp

110

120

50

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW), support for base plate and motor
CR(E), CRI(E), CRN(E)
10

15, 20
X
Connections

Motor
[kW]

AA

AAA

AB

BB

5.5
7.5
11
15
18.5

216
216
254
254
254

326
326
384
384
384

366
366
424
424
424

276
276
334
334
334

140
140
210
210
254

180
180
260
260
310

B1+119
B1+119
B1+138
B1+138
B1+138

68
68
40
40
40

45
45
45
45
45

170
170
170
170
170

200
200
200
200
200

50
50
50
50
50

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

40

DIN, oval, PJE, DIN, oval, PJE,


FlexiClamp
FlexiClamp

110

120

CR, CRI, CRN, CRT,

Pump

CR(E), CRN(E) 32, 45, 64, 90 ( 45 kW), support for base plate and motor
CR(E), CRN(E)
32

45, 64, 90
X
Connections

Motor [kW]

AA

AAA

AB

BB

1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45

140
140
160
190
216
216
254
254
254
279
318
318
356

320
320
340
370
395
395
440
455
455
485
540
540
580

380
380
400
430
455
455
500
515
515
545
600
600
640

220
220
245
275
300
300
340
340
340
365
410
410
450

100
125
140
140
140
140
210
210
254
240
305
305
310

165
165
180
180
180
180
275
266
310
310
365
365
370

B1-261
B1-261
B1-254
B1-247
B1-228
B1-228
B1-209
B1-209
B1-209
B1-196
B1-184
B1-184
B1-168

200
200
190
178
158
158
130
130
130
110
90
90
65

400
400
400
400
400
400
400
400
400
400
400
400
400

290

60

DIN

DIN

212

177

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR, CRN 120, 150 (55-75 kW), support for base plate and motor
CR, CRN
120, 150
X
Connections
Motor [kW]

AA

AAA

BB

55
75

349
368

419

409
479

100
100

B1-189
B1-167

40
10

400
400

290
290

60
60

DIN
177
177

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

41

CR, CRI, CRN, CRT,

Terminal box positions

TM05 1988 4111

Pump

Horizontal end-suction pumps

TM05 1717 3511

IEC motor

Fig. 60 Horizontal end-suction pumps

Pump
1
type

1s 3

10 15 20 32 45 64 90 120 150

CRH
CRIH
CRNH

Dimensions of CRH pumps with IEC motors, see


section 17. Technical data.

CR(E)H, CRI(E)H, CRN(E)H 50/60 Hz


CRH, CRIH, CRHN pumps are horizontal end-suction
pumps, typically mounted on base plates. The pumps
are available in a complete 50 & 60 Hz range with both
IEC or NEMA motors.
Interchangeable ANSI solution
The patented loose flange concept provides easy
installation in ANSI, DIN or JIS standard pipework.
Pump dimensions comply with the ANSI/ASME B73.1
standard and ensure interchangebility with traditional
end-suction pumps with axial suction port and radial
centre-line discharge port. This makes the CRH a
high-efficiency solution designed for ANSI-specified
applications. The back pull-out design enables service
of most versions without removing the base from the
pipework.
CRH, CRIH, CRNH pumps are suitable for a variety of
applications from pumping of potable water to pumping
of chemicals. The pumps are therefore used in a wide
variety of pumping systems where the performance
and material of the pump meet specific demands.

NEMA motor
Pump
1
type

1s 3

10 15 20 32 45 64 90 120 150

CRH
CRNH

Dimensions of CRH pumps with NEMA motors, see


WebCAPS.

Variants
The same variants and accessories are available for
the CRH, CRIH, CRNH pump range as for the standard
CR pump range. The only difference between the CR
horizontal end-suction pump and the CR inline pump is
the base. However, the base for horizontal end-suction
pumps is not available in titanium.

Construction

TM05 1989 4111

Energy efficiency
To reduce loss and thus increase the pump efficiency,
CRH, CRIH, CRNH pumps are available in an
energy-optimised version with suction and discharge
ports with a larger diameter than ANSI specifications.

TM05 1378 3511

Fig. 62 Sectional drawing

Fig. 61 CRH pump with axial suction port and radial


discharge port

Max. pressure:
30 bar.
Max. liquid temperature: 120 C (air-cooled top 180 C
(oil 240 C)).
Max. motor size:
45 kW.

42

Pos.
1
2
3
4
5
6
7
8

Designation
Pump head
Motor stool
Shaft
Impeller
Chamber
Sleeve
O-ring for sleeve
Base

Pos.
9
10
11
12
13
14
15
16

Designation
Neck ring
Shaft seal
Foot
Flange ring
Support bracket
Sleeve flange
Discharge port
Bottom bearing ring

CR, CRI, CRN, CRT,

Belt-driven pumps

Pulley head

GR5886 - GR5887

Pump type
Pulley wheel
diameter
V-belts
Pump speed
[min-1]

Type III

Type IV

Type II

Type I

0.37 - 5.5
[kW]

7.5 - 18.5
[kW]

1.5 - 7.5
[kW]

11 - 45
[kW]

CR, CRI, CRN


1s, 1, 3, 5,
10, 15, 20
10, 15, 20

Pump

For extended bearing life, we recommend these pulley


wheel sizes:

CR, CRN
32, 45, 64, 90

112-135

Min. 200

Min. 160

Min. 200

Min. 3

Min. 2

Min. 3

Max. 3000

Dimensional drawings
CR, CRI, CRN 1s, 1, 3 and 5 (type III)

Fig. 63 Belt-driven CR pump

Belt-driven pumps are used in applications for


space-saving reasons or where no electrical power is
available.
Belt-driven CR pumps are of the same construction as
electrically driven CR pumps. They do, however, have
a pulley for connection to for instance an internal
combustion motor.
Pump range
These Grundfos pumps are available as belt-driven
pumps:
Belt-driven CR pumps
1

10

15

20

32

45

64

90

CRI

CRN

120

150

TM03 4137 1706

1s

CR

Available.

CRT 2, 4, 8 and 16 pumps are also available as


belt-driven pumps.
An additional bearing has been added on top of an
existing bearing flange. The two bearings are fitted
back to back. This bearing design makes it possible to
withstand the extra radial forces caused by a pulley.
A pulley can be attached to the end of the shaft.
Note: The pulley is not supplied with the pump.
By means of pulley belts, the pump can be driven by a
motor mounted next to it rather than on top of it.
The pump can be mounted horizontally or vertically by
the extra support plates.
The pulley head is positioned on the motor stool where
the motor would normally be fitted. By means of the
existing holes in the motor stool, the pulley head can
be secured to the motor stool with bolts, washers and
nuts. The pulley wheel is then attached to the shaft
using an appropriate bush and key.

CR, CRI, CRN 10, 15 and 20 (type III)

TM03 4168 1706

Pump
type

43

CR, CRI, CRN, CRT,

TM03 4170 1706

CR, CRN 32, 45, 64 and 90 (type II)

44

TM03 4171 1706

CR, CRN 32, 45, 64 and 90 (type I)

TM03 4169 1706

Pump

CR, CRI, CRN 10, 15 and 20 (type IV)

CR(I) deep-well pumps

Technical data

CR(I) deep-well pumps are used for deep-well


pumping in small water supply systems where water is
pumped from depths (HD) down to 90 metres.

Maximum system pressure:


Maximum ambient temperature:
Maximum liquid temperature:
Minimum size of borehole

Pump

CR, CRI, CRN, CRT,

16 bar
+40 C
+40 C
3"

Pump range
These pumps are available with ejector:
Pump
type

HD

CR deep-well pumps
1s

CR

CRI

10

15

20

32

45

64

90

120

150

CRN
Available.
TM03 2954 4905

Use of suction pipe

Fig. 64 System with CR(I) deep-well pump

If the well capacity is lower than the pump capacity, dry


running of the pump can be prevented by fitting a
suction pipe below the ejector. To enable this, the
ejector strainer (E) is replaced with a special threaded
nipple.
Performance curves and technical data

The pump system consists of a dry-installed CR(I)


multistage centrifugal pump connected to a one-size
submerged ejector via two pipes.
We recommend to connect a pressure tank to the
discharge side of the pump to maintain a suitable
pressure at the tapping point.

For information about the performance curves and


technical data of CR deep-well pumps, see page 68
and 137.
Ejectors
Based on the performance curves on page 68, we offer
the following ejectors:

Ejector type

Product number

45B

90230045

44B

90230044

29B

90230029

22B

90230022

20B

90230020

11B

90230011

Contact Grundfos for further information about CR(I)


ejector pumps.

G
F
E

TM03 2953 4905

Fig. 65 Sectional drawing of ejector

Water is pumped through the pressure pipe (A) and the


strainer (B) to the nozzle (C). The water passes the
nozzle at high speed and flows into the diffuser (D).
Via the strainer (E) and bottom valve (F), water which
is to be pumped up is in connection with the chamber
(G).
From the chamber, it is pressed into the diffusor (D) by
the water jet from the nozzle (C). There the two water
flows mix, and the velocity is converted into pressure,
driving the water up through the riser pipe (H) to the
suction port of the pump.

45

CR, CRI, CRN, CRT,

Pump

Pump rubber parts

Bearing flange

We offer pumps with a wide range of customised


rubber materials such as EPDM, FKM, FFKM and FXM
to suit your requirements.

To ensure long pump life and reliable operation, a


bearing flange can be fitted between the motor and the
pump head.

Rubber material

Pump type
CR,
CR,
CR,
CR,

EPDM

CRI, CRN 1s, 1, 3, 5


CRI, CRN 10, 15, 20
CRN 32, 45, 64, 90
CRN 120, 150

FKM

FFKM

1)

FXM

Available.
1)
These pumps are fitted with FXM sleeve gaskets. All other rubber parts
are of FFKM.

Pump
type

1s

10

15

20

32

45

64

90

120

150

CR(E)

CRI(E)

CRN(E)

TM03 4062 1406

We offer customised rubber materials for these pump


types:

Fig. 66 Bearing flange

Available.

Key

Empty chambers

Pos.

We offer customised pumps with empty chambers


designed to meet your specific duty point!
CR pumps with a predefined number of chambers are
selected from the standard range. See for instance the
performance curves of CR 20-14 and CR 20-17 on
page 7. In order to avoid the selection of a pump too
large for your duty point, we offer customised pumps
with empty chambers enabling an optimum match.
We offer pumps with empty chambers for the following
pump types:
Pump
type

1s

10

15

20

CR(E)

CRI(E)

CRN(E)

32

45

64

90

120

Available.
Note: CRT(E) 2, 4, 8 and 16 are also available as
customised pumps with empty chambers.

150

Designation

Motor

Bearing flange

Pump head

A bearing flange is an additional flange with an


oversize ball bearing to absorb axial forces in both
directions. The coupling is part of the bearing flange
fitted to obtain optimum alignment.
Note: The bearing flange requires a motor with keyway
and ball bearings according to IEC 34 and NEMA.
A bearing flange is used in two situations:
1. A standard motor with standard ball bearing is
required. The bearing flange absorbs the hydraulic
load from the pump, ensuring an acceptable motor
bearing life.
2. The pump is to run at a higher inlet pressure than
the maximum pressure recommended.
Note: For motor sizes above 11 kW, the bearing flange
is equipped with grease nipples and must be lubricated
regularly. Please follow the instructions on the bearing
flange.
Pump range
The following pump types are available with bearing
flange:
Pump
type

1s

10

15

20

32

45

64

90

CR(E)

CRI(E)

CRN(E)

120

Available.

Note: CRT(E) 2, 4, 8 and 16 are also available as


customised pumps with bearing flange.

46

150

Bearing flange for CR pumps

Dimensions

CR, CRI, CRN 1s, 1, 3, 5 ( 7.5 kW)


CR, CRI, CRN 10, 15, 20 ( 4 kW)

The following additional heights in mm must be added


to the total height of the pump.

Pump

CR, CRI, CRN, CRT,

CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20


Motor power

Additional height

TM02 7436 3403

IEC [kW]

CR, CRI, CRN 10, 15, 20 ( 5.5 kW)

0.37 - 0.55

31

0.75 - 1.1

32

1.5 - 4.0

40
23 1) / 150 2)

5.5 - 7.5
11.0 - 18.5

150

NEMA [hp]
0.33 - 2.0

45

15 - 40

135

1)

TM02 7437 3403

2)

CR, CRN 32, 45, 64, 90 ( 7.5 kW)

40

3.0 - 10

CR, CRI, CRN 1s, 1, 3, 5


CR, CRI, CRN 10, 15, 20.

CR, CRN 32, 45, 64, 90


Motor power

Additional height

IEC [kW]
3.0 - 7.5

23

11.0 - 45

20

TM01 4352 0199

NEMA [hp]

CR, CRN 32, 45, 64, 90 (> 7.5 kW)

3.0 - 10.0

22

15.0 - 60.0

17

For information about the total height of a given CR


pump, see these data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CRT, CRTE
CR, CRN high pressure.
The above data booklets are available in WebCAPS.
See page 165.

TM01 4353 0199

Support bearings
We offer customised pumps with support bearings of
bronze for corrosive applications for these pump types:
Pump
type

1s

CR(E)

10

15

20

32

45

64

90

120

150

CRI(E)
CRN(E)
Available.

47

CR, CRI, CRN, CRT,

Dry-running protection

We offer pumps with a wide range of customised


bearing materials such as bronze, tungsten carbide
and carbon-filled PTFE to suit your requirements.

LiqTec

Pump size

Bearing material
Bronze/tungsten carbide
EPDM/tungsten carbide
Silicon carbide/tungsten carbide

CR, CRN 1, 3, 5, 10, 15, 20


CR, CRN 32, 45, 64, 90

GR9415

Pump

Bearing material

We offer customised rubber parts for these pump


types:
Fig. 67 LiqTec dry-running protection device

Pump
type

1s

10

15

20

32

45

64

90

CR(E)

CRI(E)

CRN(E)

120

150

Available.

Pump head positions


The pump head is mounted so that the air vent screw
is in line with the discharge port as standard.
The pump head can be mounted in three other
positions in steps of 90 .
Note: The air vent of horizontal pumps must always
point upwards.

Customised nameplate
We offer additional customised nameplates attached to
the pump:
A nameplate supplied by you.
A Grundfos nameplate customised in terms of a
specific duty point.
A Grundfos nameplate with a tag number.
Note: A Grundfos standard nameplate is always fitted
on the pump.

48

The Grundfos LiqTec immediately cuts off the pilot


current to the motor protection relay in these cases:
There is no liquid in the pump.
The liquid temperature exceeds +130 5 C.
The sensor, sensor cable, electronic unit or power
supply fails.
When connected to the PTC sensors in the motor, the
LiqTec also protects the motor against overheating.
The sensor is easily inserted through the 1/2"
connection in the pump head close to the shaft seal. It
can, however, also be used externally.
The LiqTec sends a heat impulse through the sensor,
measuring the temperature of the sensor. Liquid in the
pump cools the sensor as well as the shaft seal and
other pump parts.
If there is no liquid present, the LiqTec detects a high
temperature in the sensor and cuts out the pump
immediately to prevent damage.
The LiqTec also prevents excessive liquid
temperatures from damaging the pump. If the LiqTec
senses a liquid temperature above +130 C, it cuts out
the pump immediately. The LiqTec is a fail-safe device,
meaning that the pump stops as soon as the sensor
detects an error on the sensor cable or the electronics,
or if the power supply of the control unit is switched off.
Restarting of the pump can be automatic or manual
when the sensor detects liquid in the pump again.
Remote restarting is possible via a digital input.
The electronic control unit can also be connected to
the PTC sensor measuring the motor temperature. In
case of overheating of the motor, the system cuts out
the pump.

Figures 68 and 69 show installation examples.

Dimensions

L1
L2
L3

116 x 90 mm. The LiqTec can be mounted on a DIN rail


in a control cabinet.

Pump

CR, CRI, CRN, CRT,

Technical data

N
Sensor

K1

Supply voltage

T+

5W

Max. pressure

3
External
restart

1 x 80-130 V or 1 x 200-240 V

Power consumption

T+

T+

40 bar

Brown/Black
Blue
White

Min./max. liquid temperature

-20 C/120 C

Max. ambient temperature

50 C

Humidity

99 %

Enclosure class

IPX0
Any water-based liquid handled by
Grundfos pumps

Pumped liquid

5 m 1)

Cable length
1)

15-metres cable is available on request.

TM03 0112 4004

Connections

K1

Fig. 68 LiqTec connected to a standard motor


L1
L2
L3

A base with TriClamp connection is of hygienic design


with a sanitary coupling for use in the pharmaceutical
and food and beverage industry.
A set consists of one clamping ring, one gasket and
one pipe stub.
The connection is in accordance with EN/DIN 32676.
Dimensions
All dimensions are in mm.

Sensor

T+

MGE
3

4 x 13

T+

100
150
162

TM03 4648 3507

Brown/Black
Blue
White

50

External
restart

50.5

T+

22

CR pumps with TriClamp connection

32
180
210

Fig. 70 TriClamp connection for CRI, CRN 1s, 1, 3 and 5

2 3 9

Fig. 69 LiqTec connected to an MGE motor

26

4 x 13

130
200

50
215
248

CRI,
10: 10
80
80
on CRN
CRI, CRN
CRI,
15, 15
20:and
9020
90
on CRN
CRI, CRN

TM03 4649 2406

Terminals in MGE motor

TM04 4472 1309

64

202

Fig. 71 TriClamp connection for CRI, CRN 10, 15 and 20

49

CR, CRI, CRN, CRT,

Pump type

Nominal diameter

CRI(E), CRN(E)
1s, 1, 3, 5

38.0
32.0
51.0
50.0

92.0
102.0
104.4
123.0

59.5
60.0
74.0
75.0

CRI(E), CRN(E)
10, 15, 20

TM03 4646 2406

Gasket

TM03 4645 2406

Port

B
50.5

21.5

64.0
65.0

TM03 4647 2406

Pump

Clamping ring

35.6
32.0
48.6
50.0

38.6
36.0
51.6
54.0

35.3
32.2
48.0
50.2

B
50.5
64.0

The clamping ring is made of stainless steel


EN/DIN 1.4301/AISI 304.
The port is made of stainless steel
EN/DIN 1.4401/AISI 316.
The gasket is made of PTFE or EPDM.
Connection

Pipework
connection

Pump type

Connection
material

PTFE

CRI(E), CRN(E)
1, 3, 5

DN 32

EPDM

GR5840

Stainless steel
CRI(E), CRN(E)
10, 15, 20

DN 50

1s

10

15

20

CRI(E)

CRN(E)

CR(E)

Available.

50

32

45

64

90

PTFE
EPDM

We offer TriClamp connections for these pump types:


Pump
type

Gaskets

120

150

Pressure
[bar]
16
50
16
50

Coupling sets
required

Product number

2
2
2
2
2
2

96515375
96515374
97549395
96515377
96515376
97549397

CR, CRI, CRN, CRT,

Pump

CR pumps with connection to EN/DIN 11851


A base with connections according to EN/DIN 11851 is
of hygienic design for use in dairies and in the food
and beverage industry.
A set consists of one pipe stub with external thread
designed for a flexiClamp base with union connection.
Dimensions
All dimensions are in mm.
M10 x 40

100
150
321

TM03 4682 2506

50

22

4 x 13

75
180
210

Fig. 72 Connection to EN/DIN 11851 for CRI, CRN 1s, 1, 3


and 5

M10 x 40
26

4 x 13

130
200
394

TM03 4683 2506

100
215
248

CRI,
10: 80
80 onCRN
CRI, CRN
10
CRI,
15, 20:
90 20
90 onCRN
CRI, CRN
15 and

Fig. 73 Connection to EN/DIN 11851 for CRI, CRN 10, 15


and 20
Pump type

Pipework connection

CRI(E), CRN(E)
1, 3, 5

DN 32

CRI(E), CRN(E)
10, 15, 20

DN 50

Connection material

Gaskets

Stainless steel

EPDM
FKM
EPDM
FKM

Pressure
[bar]

Coupling sets required

Product number

16

2
2
2
2

96551545
96551547
96551549
96551570

We offer the above connections for these pump types:


Pump
type

1s

10

15

20

32

45

64

90

120

150

CR(E)
CRI(E)
CRN(E)

Available.

51

CR, CRI, CRN, CRT,

Pump

CR pump with PJE coupling


A base with PJE couplings is designed for use in a
wide range of industrial applications.
A set consists of two coupling halves, one gasket, one
coupling liner for welding and bolts and nuts.
Dimensions

88.9

All dimensions are in mm.

170
226
320

TM03 4719 2506

105

30

4x 14

240
298

114.3

Fig. 74 PJE coupling for CRN 32

190
251
365

TM03 4720 2506

140

45

4x 14

266
331

114.3

Fig. 75 PJE coupling for CRN 45

TM03 4721 2506

140

45

4x 14

266

190
251
365

331

114.3

Fig. 76 PJE coupling for CRN 64

199
261
380

280
348

TM03 4722 2506

140

45

4x 14

TM04 4558 1609

Fig. 77 PJE coupling for CRN 90

Fig. 78 PJE coupling for CRN 120 and 150

52

Designation

TM00 3709 0894

TM00 3712 0894

Part

Designed for pump type

Victaulic type 77 coupling


3": 89
4": 114

Rubber parts

Product number

CRN 32

NBR seal 3"

00ID7664

CRN 45, 64, 90, 120, 150

NBR seal 4"

96415463

CRN 32

N version 3"

00150574

CRN 45, 64, 90, 120, 150

N version 4"

96416743

Victaulic coupling liner for welding

We offer PJE couplings for these pump types:


Pump
type

1s

10

15

20

32

45

64

90

Customised connections
120

150

CR(E)
CRI(E)

CRN(E)

Available.
Note: PJE connections are available on CRI, CRN, 1s,
1, 3, 5, 10, 15 and 20 pumps as standard.
CR pumps with ANSI or JIS connection
We offer pumps with ANSI or JIS flanges for these
pump types:
Pump
type

1s

Pump

CR, CRI, CRN, CRT,

10

15

20

32

45

64

90

120

150

CR(E)

CRI(E)

CRN(E)

Available.
Note: ANSI and JIS connections are available on CRI,
CRN, 1s, 1, 3, 5, 10, 15 and 20 pumps as standard.
Technical data
Connection

Max. rated pressure

ANSI
JIS

Class 300
30 K

We offer a wide range of customised connections for


these pump types:
Pump
type

1s

10

15

20

32

45

64

90

CR(E)

CRI(E)

CRN(E)

120

150

Contact Grundfos for further information about


customised connections.
We also offer these connections:
oval flanges (BSP)
DIN flanges
PJE couplings (Victaulic) for CRN(E)
clamp couplings (L-couplings)
unions (+GF+).
For further information about connections, see these
data booklets:
CR, CRI, CRN, CRE, CRIE, CRNE
CR, CRN high pressure
CRT, CRTE.
All data booklets are available in WebCAPS.
See page 165.

Note: CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 and 10


pumps are available with flanges that meet the
requirements of both DIN, ANSI and JIS as standard.
The dimensions of pumps with DIN, ANSI or JIS
flanges are the same, apart from the flange bolt holes.

53

10

CR, CRI, CRN, CRT,

Certificates

10. Certificates
CR pumps with certificates
We offer certificates for a number of applications
requiring documentation on the pump quality.
Examples:
pharmaceutical industries
maritime and offshore applications
potentially explosive environments
energy and power suppliers.
Note: The certificates must be ordered with the pump.
These pumps are available with certificates:
Pump
type

1s

CR(E)

CRI(E)

CRN(E)

10

15

20

32

45

64

90

120

150

Available.

Note: Certified and approved CRT(E) 2, 4, 8 and 16


pumps are also available.
Certificates
Certificate
Certificate of compliance with the order
Test certificate. Non-specific inspection and testing
Inspection certificate 3.1

Inspection certificate

Standard test report


Material specification report
Material specification report with certificate from raw
material supplier
Duty-point verification report
Surface-roughness
Vibration report
Motor test report
Cleaned and dried pump
Electropolished pump
ATEX-approved pump

Description
According to EN 10204, 2.1. Grundfos document certifying that the pump supplied is in
compliance with the order specifications.
According to EN 10204, 2.2. Certificate with inspection and test results of a non-specific
pump.
Grundfos document certifying that the pump supplied is in compliance with the order
specifications. Inspection and test results are mentioned in the certificate.
Grundfos document certifying that the pump supplied is in compliance with the order
specifications. Inspection and test results are mentioned in the certificate. Certificate from the
surveyor is included.
We offer the following inspection certificates:
Lloyds Register of Shipping (LRS)
Det Norske Veritas (DNV)
Germanischer Lloyd (GL)
Bureau Veritas (BV)
American Bureau of Shipping (ABS)
Registro Italiano Navale Agenture (RINA)
China Classification Society (CCS)
Russian maritime register of Shipping (RS)
Biro Klassifikasio Indonesia (BKI)
United States Coast Guard (USCG)
Nippon Kaiji Koykai (NKK)
Certifies that the main components of the specific pump are manufactured by Grundfos, and
that the pump has been QH-tested, inspected and conforms to the full requirements of the
appropriate catalogues, drawings and specifications.
Certifies the material used for the main components of the specific pump.
Certifies the material used for the main components of the specific pump. A material
certificate, EN 10204, 3.1, will be supplied for each main component.
Certifies a test point specified by the customer. Issued according to ISO 9906 concerning
"Duty point verification".
Shows the measured roughness of the cast pump base of the specific pump. The report
indicates the values measured at the base inlet and outlet according to ISO 1302.
Vibration report indicating the values measured during the performance test of the specific
pump according to ISO 10816.
Shows the performance test of the specific motor, including power output, current,
temperature, stator windings resistance and insulation test.
Confirms that the specific pump has been cleaned and dried, and how it was done.
Confirms that the specific pump has been electropolished. The maximum surface roughness
is specified in the report.
Confirms that the specific pump is ATEX-approved according to the EU directive 94/9/EC, the
"ATEX directive".

See examples of the certificates on pages 55 to 58.


Note: Other certificates are available on request.

54

10

CR, CRI, CRN, CRT,

Certificates

Examples of certificates
Certificate of compliance with the order

Test certificate

Certificate of compliance with the order

Test certificate
Non-specific inspection and testing

EN 10204 2.1

EN 10204 2.2

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.

Customer name
Customer order no.
Customer Tag no.
GRUNDFOS order no.
Product type

Pump
Pump type
Motor make
Flow
Head
Power P2
Voltage
Frequency
Full load current
Motor speed

We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

Part number
P ar t num b e r
m3/h
m
kW
V
Hz
A
min -1

Signature:
Name:
Dept.:
Part no. 96 50 78 95/1001002

GRUNDFOS

TM03 4165 1706

GRUNDFOS
Date:

Date:
Signature:
Name:
Dept.:
Part no 96 50 78 96/1001002

Inspection certificate 3.1

Inspection certificate

Inspection certificate.

Inspection certificate.

EN 10204 3.1

Manufactured by
GRUNDFOS order no.
GRUNDFOS DUT id.
Customer order no.
Customer name
and address
Shipyard / factory
Ship / new building
Customer TAG no.
Classifying society

GRUNDFOS authorized department


Motor
Make
Part number
Serial No.
P2 (kW)
Voltage (V)
Current (A)
n(min-1)
Frequency (Hz)
Insulation class
Power factor

Din / W. - No.
Base/Pump head cover
Impeller/guidevanes
Shaft/sleeve
Customers requirements
Flow rate (m3/h)
Test result ref. requirements
Q(m3/h)
H(m)

n(min )

I(A)

Motor
Make
Part number
Serial No.
P2 (kW)
Voltage (V)
Current (A)
n(min-1)
Frequency (Hz)
Insulation class
Power factor

Din / W. - No.
Base/Pump head cover
Impeller/guidevanes
Shaft/sleeve

Head (m)
-1

Russian Maritime Register of Shipping ( RS )

Pump
Pump type
Part number
Serial no.
Flow rate (m3/h)
Head (m)
Max. ope. P/t (bar / C)
Service
Medium

Customers requirements
Flow rate (m3/h)

P1(kW)

Test result ref. requirements


Q(m3/h)
H(m)

Bar no leaks or deformation observed

Hydrostatic test

Head (m)
-1

n(min )

I(A)

P1(kW)

Bar no leaks or deformation observed

The pump has been marked

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no. 96 50 78 97/1014142

Surveyor signature:
Tested date:

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no. 96 50 79 25/1014142

TM03 4156 3607

Pump
Pump type
Part number
Serial no.
Flow rate (m3/h)
Head (m)
Max. ope. P/t (bar / C)

Hydrostatic test

Russian Maritime Register of Shipping

TM03 4162 3607

Manufactured by
GRUNDFOS order no.
GRUNDFOS DUT id.
Customer order no.
Customer name
and address
Shipyard / factory
Ship / new building
Customer TAG no.
Classifying society

TM03 4163 1706

We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured, tested, inspected, and conform to the full
requirements of the appropriate catalogues, drawings and / or specifications relative thereto.

55

10

CR, CRI, CRN, CRT,

Certificates

Standard test report

Material specification report

Material specification report.

Standard test report


Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
Production code

Customer name
Customer order no.
Customer Tag no.
GRUNDFOS order no.
Product type
GRUNDFOS DUT id.
Part number
We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications
relative thereto.
The attached test result is from the above mentioned pump.

Pump
Pump head
Pump head cover
Shaft
Impeller
Chamber
Outer sleeve
Base

Materials

DIN W.-Nr.

AISI / ASTM

Signature:
Name:
Dept.:
Part no. 96 50 79 30 P01 /A72775

GRUNDFOS

TM03 4143 1706

GRUNDFOS
Date:

Date:
Signature:
Name:
Dept.:
Part no 96 50 79 28/A72775

Material specification report with certificate from raw material


supplier

Duty point verification report

Material specification report


with EN10204 3.1
material certificate from raw
material supplier

Duty point verification report

Customer name
Customer order no.
Customer Tag no.
GRUNDFOS order no.
Product type
GRUNDFOS DUT id.
Part number

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
Production code

Pump
Pump head
Pump head cover
Shaft
Impeller
Chamber
Outer sleeve
Base

TM03 4150 1706

We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications
relative thereto.

Raw materiel no.

Supplier certificate no.

Signature:
Name:
Dept.:
Part no 96 50 79 29/A72775

56

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no. 96 53 96 99 /A72775

TM03 4148 1706

GRUNDFOS
Date:

TM03 4149 3607

We the undersigned hereby guarantee and certify that the materials and/or parts for the
above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

10

Surface-roughness

Certificates

CR, CRI, CRN, CRT,

Vibration report

Vibration report
According to ISO 10816

Surface roughness
According to ISO 1302

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
GRUNDFOS DUT id.

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
CRN base part number

Measured object
Pump type
P2 (kW)
Number of poles

Part number
Frequency (Hz)
Serial no.

Test conditions
The pump is floormounted on vibration
absorbers.

The surface roughness is measured as the maximum roughness of the CRN inlet and outlet
surface.

Voltage (V)
Frequency: (Hz)
Flow (m/h)
Head (m)
For vibration velocity measurement positions, see figure.

Remarks
B

Result of measurement:

Typical zone boundary limits


Pos

[m]
[m]
[m]

Me a s ur ed v a l ue s B
R max
RA
RZ

[m]
[m]
[m]

Roughness
degree
N 12
N 11
N 10
N9
N8
N7
N6
N5
N4
N3
N2
N1

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no 96 50 79 31/A72775

RMS vibration
Class I
Class II
velocity (mm/s)
0.28
A
0.45
A
0.71
1.12
B
1.8
B
2.8
C
4.5
C
7.1
11.2
D
18
D
28
45
The machine classifications are as follows:
Class I: Individual parts of engines and machines, integrally
connected to the complete machine in its normal operating
condition. (Production electrical motors of up to 15 kW are
typical examples of machines in this category.)
Class II: Medium-sized machines (typically electrical motors
with 15 kW to 75 kW output) without special foundations,
rigidly mounted engines or machines (up to 300 kW) on special foundations.

GRUNDFOS
Date:

Part no 96 50 79 32/A72775

Motor test report

Cleaned and dried pump

Motor test report

Cleaned and dried pump

Customer name
Customer order no.
Customer Tag no.
GRUNDFOS order no.
GRUNDFOS DUT id.
Part number
Motor no.
Motor serie no.

26-Apr-06

Signature:
Name:
Dept.:

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
Production code

We the undersigned hereby guarantee and certify that the above motor has been tested.
The performance of the motor can be seen in the motor test report on the next page.

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the
specifications mentioned in the CR, CRI, CRN Custom-built pumps data booklet. This means
that prior to assembly, pump components are washed in pure, hot soap water, rinsed in deionized water and dried.
The pump is wrapped in a plastic bag before being packed.

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no. 96 50 79 33 /A72775

TM03 4146 1706

The pump has not been performance-tested.

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no 96 50 79 34/A72775

TM03 4145 1706

Mea sure d val u es A


R max
RA
RZ

Roughness
value RA [m]
50
25
1 2. 5
6. 3
3.2
1.6
0.8
0.4
0 .2
0.1
0 . 05
0 . 0 25

1
2
3
4
5
6
7
8
9

TM03 4147 3607

Surface Treatment
None
E lec t r o-p ol is h ed

RMS vibration
velocity (mm/s)

TM03 4167 1706

57

10

CR, CRI, CRN, CRT,

Certificates

Electropolished pump

ATEX-approved pump

Electro-polished pump

ATEX-approved pump

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
Production code

Customer name
Customer order no.
Customer TAG no.
GRUNDFOS order no.
Pump type
GRUNDFOS DUT id.
Part number
Production code
Pump serial no.
Motor serial no.
ATEX approval of pump
Technical file no.

Grundfos hereby conforms that the pump mentioned above is manufactured according to the
specifications mention in the CR, CRI, CRN Custom-built pumps data booklet. This means
that prior to asembly, pump components are electro-polished in a mixture of sulphuric acid
and phosphoric acid. Finally the components are passivated in nitric acid.
The CRN1s, 1, 3, 5, 10, 15, and 20 casted parts are all mechanically polished before being
electropolished.
The pump will then optain following surface roughness;
________________________________________________________________________
Pump type

96499604

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the
ATEX directive. This means the pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as mentioned in the ATEX Supplement to installation and operating instructions supplied with the pump.

Stainless steel
casted parts

Stainless steel
Surface
plate and other
roughness
non casted parts
( m )
________________________________________________________________________
CRN1s, 1, 3, 5
*
*
equal to or below 0,8
_______________________________________________________________________
CRN10, 15, 20
*
*
equal to or below 0,8
________________________________________________________________________
between 10 15
*

equal to or below 0,8


GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no 96 50 79 35/A72775

58

GRUNDFOS
Date:
Signature:
Name:
Dept.:
Part no 96 51 22 40/A72775

TM03 4166 1706

TM03 4144 1706

CRN32, 45, 64, 90

11

CR, CRI, CRN, CRT,

CRE pump solutions

11. CRE pump solutions


Control panel

GR9033

Extended functional module


(MGE I/O)
Bus communication module
(GENI/RS485)

Fig. 79 Motors for CRE, CRIE, CRNE, CRTE pumps

TM03 8612 2007

Figure 81 shows the terminal box of the motor


containing a basic controller, an extended functional
module and a GENIbus communication module.

NC C NO

L1 L2 L3

0-10 V
0/4-20 mA

4-20 mA

1/0
1/0
1/0

13 12 11 10 1 9 8 7

B Y A

Group 1

STOP
RUN
0/4-20 mA

0-10 V
10K

*)

6 5 4 3 2

*) 0.37 - 7.5 kW only: The changeover follows the


function of digital input 4.
Factory setting: Not active (NO) <-> active (NC)

TM02 9032 1504

CRE pumps with extended functional module enable


the control of more than one parameter, such as
pressure, differential pressure, temperature,
differential temperature or flow rate.
CRE, CRIE, CRNE, CRTE pumps are equipped with
these parts as standard:
a control panel on the terminal box front.
a basic controller with one digital input for start/stop,
one analog setpoint input, etc.
a functional module with three digital inputs, one
analog sensor input, one analog sensor output and
24 V supply.
a GENIbus communication module.
See also page 61.
Note: If the GENIbus communication module is not
required, we offer motors without the module.
The version is the same for CRE, CRIE, CRNE, CRTE
pumps with and without sensor.
Figure 80 shows the hardware combination of a
standard CRE pump with extended functional module.

Fig. 80 Hardware combination of a standard CRE pump

Group 3

CRE pump with extended


functional module

Terminal box including


basic frequency converter
and basic controller

Group 2

Besides continuously variable performance, CRE,


CRIE, CRNE, CRTE pumps offer a number of
advantages depending on the hardware and software
combinations of the motor.
We offer the following CRE pump solutions:
CRE pump with extended functional module
customised CRE pump solutions.
CRE pumps are not dependent on the frequency of the
supply voltage and are designed for operation at
frequencies between 750 min-1 and 6000 min-1.
This offers a number of advantages:
compact pump
higher performance in relation to physical size
larger dynamic range
less noise at reduced speed
more gentle handling of the pumped liquid at
reduced speed.
The speed may be chosen freely, taking into
consideration the maximum motor load and the
hydraulic properties of the pump. Pumps can be
delivered with oversize or undersize motors depending
on load profile. Ball bearing configuration can also be
altered to fit load and demands.

Fig. 81 Customised CRE pump with extended functional


module (0.37 - 22 kW)

59

11

CR, CRI, CRN, CRT,

CRE pump solutions

Key
Group No

Terminals

Description

Basic controller
2
3
4
5
6

Start/stop
GND
Setpoint input
+10 V
GND

Functional module:
Extended module (MGE I/O)
Multi-pump module (Multi-E)

Functional module

GENIbus communication
module (GENI/RS485)

13
12
11
10
1
9
8
7

Terminal box incl. basic


frequency converter and
basic controller

GND
Analog output (0-10 V)
Digital input 4
Digital input 3
Digital input 2
GND
+24 V
Sensor input

GENIbus communication module

RS-485B
Screen
RS-485A

Potential-free signal relay


NC, C, NO

Motor

Outputs for signal relay

Voltage supply
3

L1, N, PE:
L1, L2, L3:

Single-phase motor
Three-phase motor

TM03 4114 1606

B
Y
A

Fig. 82 Motor combination of customised CRE pumps

60

Control panel

As an alternative to the other CRE pump solutions, we


offer CRE pump solutions for your requirements!
It is possible to put together CRE pumps by
selection/deselection:
Selection of a control panel on the front of the
terminal box of the motor.
Note: If the control panel is deselected, a blanking
plate is fitted, and the motor cannot communicate
with the R100 remote control.
Selection of a multi-pump functional module,
reduced functional module or other
application-specific add-on cards.
Note: The motor can only contain one functional
module.
Selection/deselection of a GENIbus communication
module. See also page 61.
Our CRE pump solutions make it possible to read in
customised configuration files, the so-called gsc files,
for optimum operation. The configuration files can be
read into the motor during the final test at Grundfos, at
start-up or in connection with service by means of
Grundfos PC Tool products.
Note: When configuration files have been read in, it is
still possible to make adjustments. They can be made
by means of the R100 remote control, control panel or
PC Tool products. See page 63.
Figure 82 shows the hardware combination of the
motor for a customised CRE pump.

The control panel on the front of the terminal box of the


motor enables setpoint setting and communication.

Three-phase motor

Single-phase motor

TM02 8513 0304 - TM00 7600 0304

Customised CRE pump solutions

TM02 0936 0501

Fig. 83 Buttons
and
for manual setting of the
setpoint of the pump

Fig. 84 Communication with the CRE pump by means of


the R100 remote control

11

The R100 remote control is based on IR


communication and is to be pointed at the control
panel of the motor during communication.
If a motor without control panel is ordered, it is
supplied with a blanking plate. See fig. 85.
Note: Motors with blanking plate cannot communicate
with Grundfos R100.

CRE pump solutions

CR, CRI, CRN, CRT,

Superior control system

PROFIBUS or
another protocol
Gateway

Blanking plate

GR4345

GENIbus

Fig. 85 Motor without control panel

GENIbus communication module

CIU/CIM

LonMark
PROFIBUS
ModBUS
Interbus S.
GSM

Service PC

GRM *)
)

*
GENIbus

G100

270

250

200

150

Bus protocol

G10-LON

Grundfos gateway solutions

Third-party
gateway

Gateways can convert GENIbus to other bus


protocols.

x
x

x
x
x

x
x

Must support
GENIbus

MPC or another unit

Fig. 87 External bus communication

100

The GENIbus communication module enables


communication in the following ways:
internal bus communication between two or more
Grundfos units (GENIbus-based network)
external bus communication via a gateway between
a Grundfos unit and an external unit, for instance a
computer or superior control system
(GENIbus to another network protocol).

Grundfos Remote Monitoring. GRM makes it possible to access


pump data on the web. Connection to GRM server is done via SMS
or GPRS.

TM04 4591 1709

GENIbus is an open protocol which can be


implemented into third-party SCADA systems.
Contact Grundfos for documentation.

Fig. 86 Internal bus communication

61

11

CR, CRI, CRN, CRT,

CRE pump solutions

Possible functions
The table shows the possible functions of the
individual functional modules.
Extended functional module
Digital input 1
Start/stop

Digital input 2, 3 and 4


Start/stop
Deactivation of input (not active)
Maximum pressure
Minimum pressure
Reverse operation
Reset alarm
External fault
Flow switch
Emergency operation
Predefined speed

Analog output
Deactivation of output (not active)
Actual speed
Actual sensor value
Actual setpoint value
Actual motor current
Actual motor load
Actual frequency

The function is available.

Connection of signal transmitters to CRE, CRIE,


CRNE, CRTE pumps
The functional module enables connection of a number
of signal transmitters, such as:
pressure sensors
differential pressure sensors
temperature sensors
differential temperature sensors
pH meters
flowmeters
level sensors.
Any signal transmitters complying with the values and
limits mentioned below may be connected to the pump.
Technical data
Inputs/output
Start/stop
External potential-free contact.
Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG.
Digital
External potential-free contact.
Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG.
Setpoint signals
Potentiometer
0-10 VDC, 10 k (via internal voltage supply).
Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG.
Maximum cable length: 100 m.

62

Voltage signal
0-10 VDC, Ri > 50 k.
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG.
Maximum cable length: 100 m.
Current signal
DC 0-20 mA/4-20 mA, R i = 250 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.25 - 1.5 mm 2 / 24-16 AWG.
Maximum cable length: 500 m.
Sensor signals
Voltage signal
0-10 VDC, Ri > 50 k (via internal voltage supply).
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG.
Maximum cable length: 100 m.
Current signal
DC 0-20 mA/4-20 mA, R i = 250 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.25 - 1.5 mm 2 / 24-16 AWG.
Maximum cable length: 500 m.
Internal power supplies
10 V power supply for external potentiometer:
Max. load: 2.5 mA.
Short-circuit protected.
24 V power supply for sensors:
Max. load: 40 mA.
Short-circuit protected.
Signal relay output
Potential-free changeover contact.
Maximum contact load: 250 VAC, 2 A, cos 0.3 - 1.
Minimum contact load: 5 VDC, 10 mA.
Screened cable: 0.5 - 2.5 mm2 / 20-14 AWG.
Maximum cable length: 500 m.
Bus input
Grundfos bus protocol, GENIbus protocol, RS-485.
Screened 3-core cable: 0.2 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

11

CR, CRI, CRN, CRT,

CRE pump solutions

Grundfos PC Tool E-products


Connection of a Grundfos PC Tool E-products offers a
number of advantages during commissioning,
operation and service of E-pumps.
The PC tool E-products enables these functions:
monitoring of operational status of your E-product
standard configuration of E-products
custom configuration of E-products
saving of logged data from E-products.
Via the PC Tool, it is possible to download special
predefined configuration files (gsc files) to the pump.
The configuration files may contain
application-optimised operating parameters based on
your specifications!
Note: When configuration files have been read in, it is
still possible to make adjustments.
Description

TM03 9290 3707

The Grundfos PC Tool E-products is a common user


platform/user interface used throughout the entire
production process of an E-pump. Furthermore,
PC Tool E-products can be used by the customer for
setting up, commissioning and servicing the E-pump.

Fig. 88 PC Tool E-products used in production and on site


by the customer

The Grundfos PC Tool E-products thus enables


configuration or reconfiguration of your product to
optimise it to exactly your application. And it is
indispensable for fault finding and service.
The software for Grundfos PC Tool E-products must be
ordered with the PC Tool Link package which contains
hardware and cables. Contact Grundfos for further
information.

63

11

CR, CRI, CRN, CRT,

TM03 3712 0806

CRE pump solutions


TM04 4607 1809

Fig. 89 PC Tool interface

Fig. 90 Monitoring function

64

12

CR, CRI, CRN, CRT,

How to read the curve charts

12. How to read the curve charts


CR deep-well

2
1
HD
[m]

No. 11B

No. 29B

No. 20B

No. 22B

No. 44B

No. 45B

100
CR(I) 5-15
90

80

CR(I) 5-13

70
CR(I) 5-11
60
CR(I) 5-9
50
40
30
20
10
0

0.0

0.25

0.50

0.1

0.75

1.00

0.2

1.25

0.3

1.50

0.4

1.75

0.5

Q [m/h]
Q [l/s]

TM01 9129 0303

0.00

Fig. 91 Example of curve chart of CR deep-well


Pos.
1
2

Description
The y-axis indicates the suction depth, HD, in metres.
Ejector numbers.

QH curve of the individual pump. The bold curves indicate


the recommended performance range for best efficiency.

The x-axis indicates the flow rate in m3/h and l/s.

65

12

CR, CRI, CRN, CRT,

How to read the curve charts

CR low-NPSH and CR pumps with 4-pole motor

p
[kPa]

H
[m]
280

-14

260
2400

-13

240

-12

220
2000

1600

-11

200

-10

180

-9

160

-8

140

-7

120

-6

100

-5

80

-4

60

-3

40

-2

CR, CRN 32
-14-2

50 Hz
ISO 9906 Annex A

-13-2
-12-2

-11-2
-10-2
-9-2
-8-2
-7-2

1200

-6-2
-5-2
800

-4-2
-3-2
400

20
0

0
0

12

16

20

24

28

32

36

Q [m/h]

10

Q [l/s]

P2
[kW]

P21/1n

Eta

2.8
2.1

80

60
P21/1
P22/3

1.4
0.7

40
20

0.0

0
0

p
H
[kPa] [m]
240

Eta
[%]

12

16

20

24

28

32

36

QH 2900 rpm1/1n

24

Q [m/h]
NPSH

NPSH
[m]
6

QH 2900 rpm1/1
160

16

80

4
QH 2900 rpm2/3
2

0
0

12

16

7
Fig. 92 Example of curve chart of CR low-NPSH
Pos.

66

Description

Number of stages.
First figure: Number of stages.
Second figure: Number of reduced-diameter impellers.

The power curves indicate pump input power per stage.


Curves are shown for pump with one stage (P21),
low-NPSH stage (P21n) and reduced-diameter impellers
(P2 2/3).

Pump type, frequency and ISO standard.

QH curve for the individual pump.


The bold curves indicate the recommended duty range for
best efficiency.

The eta curve shows the efficiency of the pump. The eta
curve is an average curve of all the pump types shown in
the chart.
The efficiency of pumps with reduced-diameter impellers is
approx. 2 % lower than the eta curve shown in the chart.

The NPSH curve is an average curve for all variants shown.


When sizing pumps, add a safety margin of at least 0.5 m.

QH curve for each individual impeller. Curves for complete


(1/1) and reduced-diameter (2/3) impellers are shown.

20

24

28

32

36

Q [m/h]

TM01 9129 0303

Low NPSH

12

CR, CRI, CRN, CRT,

How to read the curve charts

Guidelines to curve charts


The guidelines below apply to the curves shown on the
following pages:
Tolerances to ISO 9906, Annex A, if indicated.
The motors used for the measurements are
standard Grundfos motors (MG or MGE).
Measurements have been made with airless water
at a temperature of 20 C.
Kinematic viscosity of = 1 mm2/s (1 cSt).
Due to the risk of overheating, the pumps should not
be used at a flow below the minimum flow rate.
The QH curves apply to a rated motor speed of
2900 min-1. All curves are based on current motor
speeds.
The curve below shows the minimum flow rate as a
percentage of the nominal flow rate in relation to the
liquid temperature. The dotted line shows a CR pump
fitted with an air-cooled top assembly.
Qmin
[%]
20
10
0
40

60

80 100 120 140 160 180 t

[C]

TM01 2816 0303

30

Fig. 93 Minimum flow rate

67

13
CR deep-well pumps
50 and 60 Hz
Performance curves

13. Performance curves


CR deep-well
50 Hz
HD
[m]

No. 11B

No. 29B

No. 20B

No. 22B

No. 44B

No. 45B

100
CR(I) 5-15
90
80

CR(I) 5-13

70
CR(I) 5-11
60
CR(I) 5-9
50
40
30
20

0
0.00

0.0

0.25

0.50

0.1

0.75

0.2

1.00

1.25

0.3

For information about dimensions of the individual pumps, see page 137.

68

1.50

0.4

1.75

0.5

Q [m/h]
Q [l/s]

TM03 3096 1806

10

13
Performance curves

CR deep-well pumps
50 and 60 Hz

CR deep-well
60 Hz
HD
[m]

No. 11B

No. 29B

No. 20B

No. 22B

No. 44B

No. 45B

90
80
CR(I) 5-9
70

CR(I) 5-8

60
CR(I) 5-6
50
40
30
20

0
0.00

0.0

0.25

0.50

0.1

0.75

0.2

1.00

1.25

0.3

1.50

0.4

Q [m/h]
Q [l/s]

TM03 3971 1806

10

For information about dimensions of the individual pumps, see page 137.

69

13
Low-NPSH pumps
50 Hz
Performance curves

Low-NPSH pumps
p
[kPa]

H
[m]

CR, CRI, CRN 3

240

-36

50 Hz
ISO 9906 Annex A

220
2000

-33
-31

200

-29
180
1600

-27
-25

160
-23
140

1200

-21
-19

120
-17

800

100

-15

80

-12

-13
-11

-10
60

-9
-8

400

-7

40

-6
-5

-4
20
0

-3

0
0.0

0.4

0.0

0.8

1.2

0.2

1.6

2.0

0.4

2.4

2.8

0.6

3.2

0.8

3.6

4.0

1.0

4.4

Q [m/h]

1.2

Q [l/s]
Eta
[%]

P2
[kW]
Eta

0.15

60
P21/1n

0.10

40
P21/1

0.05
0.00

20
0

0.0

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

3.6

4.0

4.4

Q [m/h]

H
[m]

NPSH
[m]
QH 2900 rpm1/1

NPSH

Low NPSH

0
0.0

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

For information about dimensions of the individual pumps, see page 114.

70

3.6

4.0

4.4

Q [m/h]

TMX2 1186 1309

QH 2900 rpm1/1n
6

13

p
[kPa]

H
[m]

CR, CRI, CRN 5

260
2400

ISO 9906 Annex A

240
-32

200

-29

180
1600

50 Hz

-36

220
2000

Performance curves

Low-NPSH pumps
50 Hz

-26
-24

160

-22
140
1200

-20
-18

120
-16

-15

100

-14
-13

800

-12

80

-11
-10
-9

60
-8

-7
400

-6

40

-5
-4
20
0
0

0.0

0.5

1.0

1.5

P2
[kW]

2.0

9Q
2.5

[m/h]
Q [l/s]
Eta
[%]

Eta
P21/1n

0.30

60

0.20

40
P21/1

0.10

20

0.00

0
0

H
[m]

9Q

[m/h]
NPSH
[m]

12

QH 2900 rpm1/1n

QH 2900 rpm1/1

NPSH

2
Low NPSH

0
0

9Q

[m/h]

TMX2 1189 1309

For information about dimensions of the individual pumps, see page 115.

71

13
Low-NPSH pumps
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 10

240

50 Hz

220
2000

1600

1200

ISO 9906 Annex A

-22

200

-20

180

-18

160

-16

140

-14

120

-12

100

-10
-9

800

80

-8
-7

60

-6
-5

400

40

-4
-3

20
0

0
0

0.0

0.5

1.0

1.5

2.0

10

2.5

P2
[kW]

11

12

3.0

Q [m/h]
3.5

Q [l/s]

Eta
P21/1n

0.6
0.4

Eta
[%]
60
40

P21/1
0.2

20

0.0

0
0

H
[m]

10

11

12

Q [m/h]
NPSH
[m]

QH 2900 rpm1/1n

12

QH 2900 rpm1/1

NPSH

2
LOW NPSH

0
0

For information about dimensions of the individual pumps, see page 115.

72

10

11

12

Q [m/h]

TM02 7391 1309

13

p
[kPa]

H
[m]

CR, CRI, CRN 15

-17

240

50 Hz
ISO 9906 Annex A

220
2000

-14

200
180

1600

Performance curves

Low-NPSH pumps
50 Hz

-12

160
-10
140
-9

1200

120

-8
-7

100

-6
800

80

-5
-4

60

-3
400

40

-2

20
0
0

10

12

14

16

18

20

22

Q [m/h]
Q [l/s]

P2
[kW]

Eta
[%]

2.0

80

Eta

1.5

P21/1n

1.0

60
40

P21/1

0.5
0.0

20
0

H
[m]

20

QH 2900 rpm1/1n

15

QH 2900 rpm1/1

10

12

14

16

18

20

22

Q [m/h]
NPSH

NPSH
[m]
4
3

10

LOW NPSH

0
0

10

12

14

16

18

20

22

Q [m/h]

TM02 7392 1309

For information about dimensions of the individual pumps, see page 116.

73

13
Low-NPSH pumps
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 20

260
2400

-17

50 Hz
ISO 9906 Annex A

240
220
-14

2000

200
-12

180
1600

160
-10
140

1200

-8

120

-7
100
800

-6
-5

80

-4

60

-3
400

40

-2

20
0
0

10

12

14

16

18

20

22

24

26

28

Q [m/h]
8

Q [l/s]

P2
[kW]

Eta
[%]

2.0

80

Eta

1.5

P21/1n

60

1.0

P21/1

40

0.5

20

0.0

0
0

H
[m]

20

QH 2900 rpm1/1n

15

QH 2900 rpm1/1

10

12

14

16

18

20

22

24

26

28

Q [m/h]
NPSH
[m]
8
NPSH

10

LOW NPSH

2
0

10

12

14

16

18

20

For information about dimensions of the individual pumps, see page 116.

74

22

24

26

28

Q [m/h]

TM02 7393 1309

13

p
[kPa]

H
[m]
280

-14

260
2400

-13

240

-12

220
2000

-11

200

-10

180
1600

-9

160

-8

140

-7

Performance curves

Low-NPSH pumps
50 Hz

CR, CRN 32
-14-2

50 Hz
ISO 9906 Annex A

-13-2
-12-2
-11-2
-10-2
-9-2
-8-2
-7-2

1200

120

-6

100

-5

-6-2
-5-2
800

80

-4

60

-3

40

-2

-4-2
-3-2
400

20
0

0
0

12

16

20

24

28

32

36

Q [m/h]

10

Q [l/s]

P2
[kW]

P21/1n

Eta

2.8
2.1

80
60

P21/1
P22/3

1.4
0.7

40
20

0.0

0
0

p
H
[kPa] [m]
240

Eta
[%]

12

16

20

24

28

32

36

QH 2900 rpm1/1n

24

Q [m/h]
NPSH

NPSH
[m]
6

QH 2900 rpm1/1
160

16

80

2
Low NPSH

0
0

12

16

20

24

28

32

36

Q [m/h]

TM01 9129 1309

QH 2900 rpm2/3

For information about dimensions of the individual pumps, see page 117.

75

13
Low-NPSH pumps
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRN 45

340
3200

-13-2
-12

2400

280

-11

260

-10

ISO 9906 Annex A

-12-2

300
2800

50 Hz

320

-11-2

-10-2
240
-9
-9-2

220
2000

-8

200

-8-2
-7

180
1600

-7-2

160

-6
-6-2

140
1200

800

-5
-5-2

120
100

-4

80

-3

-4-2
-3-2

60
400

-2

40
20
0
0

10

15

20

25

30

35

40

45

10

12

P2
[kW]

50

55

14

Q [m/h]
16

Q [l/s]

Eta

80

60
P21/1n
P21/1
P22/3

4
2
0

p
H
[kPa] [m]

40
20
0

10

15

20

25

30

35

40

45

50

55

Q [m/h]

QH 2900 rpm1/1n

NPSH
[m]

240

24

160

16

80

Low NPSH 2

QH 2900 rpm1/1
NPSH

QH 2900 rpm2/3

10

15

20

25

30

35

40

For information about dimensions of the individual pumps, see page 118.

76

Eta
[%]

45

50

55

Q [m/h]

TMX1 1451 1309

13

p
[kPa]
2000

H
[m]

Performance curves

Low-NPSH pumps
50 Hz

CR, CRN 64

200

50 Hz

-7-1

ISO 9906 Annex A

-7-2
180

-6
-6-1

1600

160

-6-2
-5

140

-5-1
-5-2

1200

120

-4
-4-1

100

-4-2
-3

800

-3-1

80

-3-2
-2

60

-2-1
400

40

20

0
0

10

20

30

40

50

10

60

15

70

80

Q [m/h]

20

25

P2
[kW]
8

Q [l/s]

Eta
P21/1n
P21/1

6
4

80
60
40

P22/3

20

0
0

p
H
[kPa] [m]
300

Eta
[%]

10

20

30

40

50

60

70

80

Q [m/h]

QH 2900 rpm1/1n

32
24

QH 2900 rpm1/1

16

QH 2900 rpm2/3

NPSH
[m]
8

NPSH

200

Low NPSH

0
0

10

20

30

40

50

60

70

80

Q [m/h]

TM02 0753 1309

100

For information about dimensions of the individual pumps, see page 118.

77

13
Low-NPSH pumps
60 Hz
Performance curves

Low-NPSH pumps
p
[Mpa]

H
[m]

CR, CRI, CRN 3

-25

240

60 Hz
ISO 9906 Annex A

220
2.0

-23
-21

200

-19

180
1.6

-17

160

-15

140
1.2

-13

120

-12
-11

100
0.8

-10
-9

80

-8
-7

60

-6
-5

0.4

40

-4
-3

20
0.0

0
0.0

0.4

0.0

0.8

1.2

0.2

1.6

0.4

2.0

2.4

0.6

2.8

3.2

0.8

3.6

4.0

1.0

4.4

4.8

1.2

5.2

1.4

P2
[kW]

Q [m/h]
Q [l/s]

0.24

Eta
[%]
60

P21/1n
Eta

0.16

40

P21/1
0.08

20

0.00

0
0.0

p
H
[kPa] [m]
80
60

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

3.6

4.0

4.4

4.8

5.2

Q [m/h]

QH 3500 rpm1/1n

NPSH
[m]
6

QH 3500 rpm1/1
NPSH

20
0

2
Low NPSH

0
0.0

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

3.6

For information about dimensions of the individual pumps, see page 119.

78

4.0

4.4

4.8

5.2

Q [m/h]

TM02 2574 1309

40

13

p
[kPa]

H
[m]

CR, CRI, CRN 5

240

-24

60 Hz
ISO 9906 Annex A

220
2000

-22

200

-20

180
1600

Performance curves

Low-NPSH pumps
60 Hz

-18

160

-16

140

-14

120

-12

100

-10

80

-8

60

-6

40

-4

-15

1200

-13
-11
-9

800

-7
-5
400

20
0

0
0

0.0

0.5

1.0

1.5

2.0

10

2.5

Q [m/h]
3.0

P2
[kW]
1.2

Q [l/s]

Eta
P21/1n

0.8
0.4

Eta
[%]
60
40
20

P21/1
0.0

0
0

p
[kPa]

H
[m]

150

15

10

Q [m/h]

QH 3500 rpm1/1n

NPSH
[m]
6

NPSH
10

50

QH 3500 rpm1/1

4
Low NPSH

2
0

10

Q [m/h]

TM02 2575 1309

100

For information about dimensions of the individual pumps, see page 119.

79

13
Low-NPSH pumps
60 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 10

260
2400

60 Hz

-17

ISO 9906 Annex A

240
-16
220

2000

-14

200
180

-12
1600

160
-10

140
1200

-9
120
-8
100

800

-7
-6

80

-5
60
400

-4

40

-3

20
0
0

0.0

0.5

1.0

1.5

2.0

10

2.5

11

12

3.0

13

3.5

14

15

4.0

16

Q [m/h]

4.5

Q [l/s]

P2
[kW]

Eta
[%]

1.6

80

Eta

1.2

P21/1n

0.8

40
P21/1

0.4
0.0

20
0

H
[m]

20

QH 3500 rpm1/1n

15

QH 3500 rpm1/1

10

11

12

13

14

15

16

Q [m/h]
NPSH
[m]
8

NPSH

10

6
4

LOW NPSH

2
0

10

11

For information about dimensions of the individual pumps, see page 119.

80

60

12

13

14

15

16

Q [m/h]

TM02 7394 1309

13

p
[kPa]

H
[m]

CR, CRI, CRN 15

260

60 Hz

-12
2400

Performance curves

Low-NPSH pumps
60 Hz

ISO 9906 Annex A

240
220
-10

2000

200
-9
180
-8

1600

160
-7
140
-6

1200

120
-5
100
-4

800

80
-3
60
-2

400

40
20

0
0

10

12

14

16

18

20

22

24

26

28

Q [m/h]
8

Q [l/s]

P2
[kW]

Eta
[%]
Eta

3.2

80
P21/1n

2.4
1.6

P21/1

0.8

60
40
20

0.0

0
0

H
[m]

10

12

14

16

18

20

22

24

26

28

Q [m/h]
NPSH
[m]

QH 3500 rpm1/1n

20

QH 3500 rpm1/1
15

6
NPSH
4

LOW NPSH

2
0

10

12

14

16

18

20

22

24

26

28

Q [m/h]

TM02 7395 1309

10

For information about dimensions of the individual pumps, see page 120.

81

13
Low-NPSH pumps
60 Hz
Performance curves

p
[kPa]
2000

H
[m]

CR, CRI, CRN 20

200

60 Hz
ISO 9906 Annex A

180
1600

-8

160

-7

140

1200

-6

120
-5
100
-4

800

80
-3
60
-2

400

40

20

0
0

12

16

20

24

28

32

Q [m/h]
10

Q [l/s]

P2
[kW]

Eta
[%]
Eta

3.2

80
P21/1n

2.4

P21/1

1.6
0.8

40
20

0.0

0
0

12

16

20

24

28

32

H
[m]
32

QH 3500 rpm1/1n

24

QH 3500 rpm1/1

Q [m/h]
NPSH

NPSH
[m]
8
6

16

LOW NPSH

0
0

12

16

20

24

For information about dimensions of the individual pumps, see page 120.

82

60

28

32

Q [m/h]

TM02 7396 1309

13

p
[kPa]

H
[m]

CR, CRN 32

280

-10-2

260
2400

Performance curves

Low-NPSH pumps
60 Hz

60 Hz
ISO 9906 Annex A

-9
-9-2

240
-8
220

2000

-8-2

200

-7
-7-2

180
-6
1600

160

-6-2
-5

140

-5-2
1200

120

-4
-4-2

100
800

-3

80

-3-2

60
400

-2

-2-1

40
20

0
0

12

16

20

24

28

32

36

40

10

P2
[kW]

44

12

Q [m/h]
Q [l/s]
Eta
[%]

Eta

80

P21/1n

P21/1
P22/3

2
0

40
20
0

12

16

20

24

28

32

36

40

44

p
H
[kPa] [m]
320

60

Q [m/h]
NPSH

NPSH
[m]

40

QH 3500 rpm1/1n

30

QH 3500 rpm1/1

20

QH 3500 rpm2/3

160
80

10

Low NPSH

0
0

12

16

20

24

28

32

36

40

44

Q [m/h]

TM02 2578 1309

240

For information about dimensions of the individual pumps, see page 121.

83

13
Low-NPSH pumps
60 Hz
Performance curves

p
[kPa]

H
[m]

2400

60 Hz

-7-2

240
-6

-6-1
-6-2

200
-5

180
1600

-7-1

ISO 9906 Annex A

220
2000

CR, CRN 45

-7

260

-5-1

-5-2

160
-4
-4-1

140
1200

-4-2

120
-3
-3-1

100
800

-3-2

80

-2
-2-1

60
400

40
20
0
0

10

15

20

25

30

35

40

10

45

12

50

55

14

60

16

65

Q [m/h]

18

Q [l/s]

P2
[kW]
8

P21/1n

80

Eta
P21/1
P22/3

60

4
2

0
0

p
H
[kPa] [m]
300

100

10

10

15

20

25

30

35

40

45

55

60

65

Q [m/h]

NPSH
[m]
8

NPSH

QH 3500 rpm2/3

6
4

Low NPSH

2
0

10

15

20

25

30

35

40

45

For information about dimensions of the individual pumps, see page 121.

84

50

QH 3500 rpm1/1

30
20

QH 3500 rpm1/1n

40

200

40
20

400

Eta
[%]

50

55

60

65

Q [m/h]

TM02 2579 1309

13

p
[kPa]

H
[m]

CR, CRN 64
-5-2

180

60 Hz

-4
1600

Performance curves

Low-NPSH pumps
60 Hz

160

ISO 9906 Annex A

-4-1
-4-2

140

-3
1200

120

-3-1
-3-2

100

-2
800

80
-2-1
60

400

40

20

0
0

10

20

30

40

50

10

60

15

70

80

20

90

Q [m/h]

25

Q [l/s]

P2
[kW]
16

Eta
[%]
80

Eta
P21/1n
P21/1

12
8

60
40

P22/3
4

20

40

300

30

200

20

100

10

20

30

40

50

60

70

80

90

Q [m/h]

QH 3500 rpm1/1n

50
400

10

NPSH
[m]
10

NPSH
QH 3500 rpm1/1

8
6

QH 3500 rpm2/3

4
2

Low NPSH

0
0

10

20

30

40

50

60

70

80

90

Q [m/h]

TM02 2580 1309

p
H
[kPa] [m]

0
0

For information about dimensions of the individual pumps, see page 122.

85

13
CR pumps with 4-pole motor
50 Hz
Performance curves

CR pumps with 4-pole motor


p
[kPa]

H
[m]

500

50 Hz
ISO 9906 Annex A

-33

50

-30

45
400

CR, CRI, CRN 1

-36

55

-27

40

-25
35
300

-23
-21

30

-19
-17

25
-15
200

20

-13
-12
-11
-10

15

-9
-8

100

-7

10

-6
-5
-4

-3
-2

0
0.0

0.1

0.00

P2
[hp]
0.015

0.2

0.3

0.05

0.4

0.10

0.5

0.6

0.15

0.7

0.8

0.20

0.9

1.0

0.25

1.1

0.30

Q [m/h]
Q [l/s]
Eta
[%]

P2
[kW]
0.010

Eta

40

0.010
P2

0.005

20

0.005
0.000

0.000

0
0.0

p
[kPa]
20

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

Q [m/h]

H
[m]

NPSH
[m]

1.0
QH 1450 rpm

0.5
NPSH
0.0
0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

For information about dimensions of the individual pumps, see page 123.

86

0.9

1.0

1.1

Q [m/h]

TM02 2543 1309

10

13

p
[kPa]

H
[m]

CR, CRI, CRN 3

60

-36

50 Hz
ISO 9906 Annex A

55
500

Performance curves

CR pumps with 4-pole motor


50 Hz

-33
-31

50
-29
45

400

-27
-25

40
-23
35

300

-21
-19

30
-17

200

25

-15

20

-12

-13
-11

-10

15

-9

-8
100

10

-7

-6

-5
-4
5

-3
-2

0
0.0

0.2

0.0

0.4

0.6

0.1

0.8

1.0

0.2

1.2

0.3

1.4

1.6

0.4

1.8

2.0

0.5

Q [m/h]
0.6

Q [l/s]

P2
[hp]

P2
[kW]

Eta
[%]

0.020

0.015

60

0.015

Eta
P2

0.010

0.010
0.005
0.000

0.005

20

0.000

0
0.0

p
[kPa]

40

H
[m]

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Q [m/h]
NPSH
[m]

QH 1450 rpm

15

1.5

1.5

10

1.0

1.0

0.5

0.0

0.5

NPSH

0.0
0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Q [m/h]

TM02 2542 1309

For information about dimensions of the individual pumps, see page 124.

87

13
CR pumps with 4-pole motor
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 5

65
600

50 Hz

-36

ISO 9906 Annex A

60
55

500

-32

50

-29

45
400

-26
-24

40

-22
35
300

-20
-18

30
-16
25

200

-15

-14

-13

-12

20

-11
-10
-9

15
-8
100

-7
-6

10

-5
-4
5

-3
-2

0
0.0

0.4

0.0

P2
[hp]

P2
[kW]

0.020

0.015

0.015

0.8

1.2

0.2

1.6

2.0

0.4

2.4

0.6

2.8

3.2

0.8

3.6

4.0

1.0

Q [m/h]
1.2

Q [l/s]

P2
Eta

Eta
[%]
60

0.010

40

0.005

20

0.000

0.010

0.000

0.0

p
[kPa]

H
[m]

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

3.6

4.0

Q [m/h]
NPSH
[m]

QH 1450 rpm

15

1.5

1.5

10

1.0

1.0

0.5

0.5
NPSH

0.0

0.0
0.0

0.4

0.8

1.2

1.6

2.0

2.4

2.8

For information about dimensions of the individual pumps, see page 124.

88

3.2

3.6

4.0

Q [m/h]

TM02 2541 1309

0.005

13

p
[kPa]

H
[m]

CR, CRI, CRN 10

60

50 Hz

-22

ISO 9906 Annex A

55
500

-20
50
-18

45
400

-16

40

-14

35
300

Performance curves

CR pumps with 4-pole motor


50 Hz

-12

30

-10

25

-9
200

-8

20

-7
-6

15
100

-5
-4

10

-3
-2

5
0

-1

0
0.0

0.5

0.0

1.0

0.2

1.5

0.4

2.0

2.5

0.6

3.0

0.8

3.5

4.0

1.0

4.5

1.2

5.0

5.5

1.4

6.0

1.6

Q [m/h]
Q [l/s]

P2
[hp]

P2
[kW]

0.08

0.06

Eta

60

0.04

P2

40

0.06

Eta
[%]

0.04
0.02
0.00

0.02

20

0.00

0
0.0

p
[kPa]

H
[m]

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

Q [m/h]
NPSH
[m]

QH 1450 rpm

2.4

1.5

1.6

1.0

20

0.8

0.5
NPSH

0.0

0.0
0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

Q [m/h]

TM02 7273 1309

10

For information about dimensions of the individual pumps, see page 125.

89

13
CR pumps with 4-pole motor
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 15

-17

60

50 Hz
ISO 9906 Annex A

55
500

50

-14

45
-12
400

40
-10

35

-9
300

30

-8
-7

25
200

-6
20
-5
15

100

-4
-3

10
-2
5

-1

0
0

0.0

P2
[hp]

P2
[kW]

0.16

0.12

0.12

0.5

1.0

1.5

2.0

10

2.5

11

3.0

Q [m/h]
Q [l/s]
Eta
P2

0.08

Eta
[%]
60
40

0.08

0.00

0.04

20

0.00

0
0

p
[kPa]

H
[m]

10

11

Q [m/h]
NPSH
[m]

QH 1450 rpm

30

1.5

20

1.0

10

0.5
NPSH

0.0
0

For information about dimensions of the individual pumps, see page 126.

90

10

11

Q [m/h]

TM02 7274 1309

0.04

13

p
[kPa]

H
[m]

CR, CRI, CRN 20

65

50 Hz

-17
600

Performance curves

CR pumps with 4-pole motor


50 Hz

ISO 9906 Annex A

60
55

500

-14
50
-12

45
400

40
-10
35

300

-8

30

-7
25
-6
200

20

-5
-4

15

-3
100

10
-2
5

-1

0
0

0.0

P2
[hp]

P2
[kW]

0.20

0.15

0.15

0.5

1.0

1.5

2.0

10

2.5

11

12

3.0

13

3.5

14

Q [m/h]

4.0

Q [l/s]
Eta
[%]
Eta
P2

60

0.10

40

0.05

20

0.10

0.00

0.00

0
0

p
[kPa]

H
[m]

10

11

12

13

14

Q [m/h]
NPSH
[m]

QH 1450 rpm

30

1.5

20

1.0

10

0.5
NPSH

0.0
0

10

11

12

13

14

Q [m/h]

TM02 7275 1309

0.05

For information about dimensions of the individual pumps, see page 126.

91

13
CR pumps with 4-pole motor
50 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRN 32

14

70

14-2
65

13

60

12

55

11

50

10

45

40

35

30

25

20

50 Hz
ISO 9906 Annex A

13-2
600

12-2

500

11-2
10-2
9-2

400

8-2
7-2
300

6-2
5-2
200

4-2
3

15

3-2
100

10

2-2
1

5
0
0

P2
[hp]
0.5
0.4
0.3

10

12

14

16

P2
[kW]

18

Q [m/h]

Q [l/s]
Eta
[%]

Eta

0.4

80

0.3

60
P21/1n
P22/3

0.2

0.2
0.1

20

0.0

0.0

p
[kPa]

H
[m]

0.1

10

12

14

16

18

Q [m/h]

NPSH
[m]

QH 1450 rpm1/1n

40

QH 1450 rpm2/3

30

20

1.0

10

0.5

2.5
2.0
NPSH

1.5

0.0
0

10

12

14

For information about dimensions of the individual pumps, see page 127.

92

40

16

18

Q [m/h]

TM01 8153 1309

1-1

13

p
[kPa]

H
[m]
85

800

80

600

11
70

11-2

65

10

60

10-2
9-2
8
50

8-2
7

45
400

7-2

40

6
6 -2

35
300

30

5-2
4

25
200

100

12-2

ISO 9906 Annex A

50 Hz

55
500

CR, CRN 45

12

75
700

13-2

Performance curves

CR pumps with 4-pole motor


50 Hz

4-2

20

15

3-2
2-2

10
1

1-1

5
0

0
0

10

12

14

16

18

P2
P2
[hp] [kW]

22

24

26

28

Q [m/h]
8

Eta

0.4
0.4

20

0.3

Q [l/s]

Eta
[%]

P21/1n

80

P22/3

60

0.2

40

0.1

20

0.0

0.2

p
H
[kPa] [m]
60

40

20

10

12

14

16

18

20

22

24

26

28

Q [m/h]
NPSH
[m]

QH 1450 rpm1/1n

1.5

QH 1450 rpm2/3

1.0
NPSH

0.5
0.0

10

12

14

16

18

20

22

24

26

28

Q [m/h]

TM01 8154 1309

0.0

For information about dimensions of the individual pumps, see page 128.

93

13
CR pumps with 4-pole motor
50 Hz
Performance curves

p
[kPa]

H
[m]

8-1

CR, CRN 64
8-2

55

50 Hz

7
500

ISO 9906 Annex A

50

7-1
7-2
6

45

6-1
400

40

6-2
5
5-1

35

5-2
300

30

4-1
4-2

25
3
200

3-1

20

3-2
2

15

2-1
100

2-2

10

1
1-1

0
0

P2
[hp]
1.0
0.8
0.6

10

15

20

25

30

35

40

10

P2
[kW]

Q [m/h]
Q [l/s]

Eta

0.8

80

P21/1n

0.6

60

P22/3

0.4

Eta
[%]

40

0.4
0.2
0.0

0.2

20

0.0

0
0

p
H
[kPa] [m]
60

10

15

20

25

30

35

40

Q [m/h]

QH 1450 rpm1/1n

NPSH
[m]
1.2

QH 1450 rpm2/3
40

0.8
NPSH

0.4
0.0
0

10

15

20

25

For information about dimensions of the individual pumps, see page 129.

94

30

35

40

Q [m/h]

TM01 8155 1309

20

13

p
[kPa]
500

H
[m]

Performance curves

CR pumps with 4-pole motor


50 Hz

CR, CRN 90

50

50 Hz
ISO 9906 Annex A
6-2

45
5
400

40
5-2
35

300

30

4-2
3

25

200

3-2

20
2
15

2-2
100

10

1
1-1

0
0

P2
[hp]

10

15

20

25

30

35

40

45

10

12

P2
[kW]

50

55

14

Q [m/h]
16

Q [l/s]

Eta

1.00

Eta
[%]
80

P21/1n
1.0

0.75

60
P22/3

0.50

40

0.25

20

0.5
0.00

0
0

p
H
[kPa] [m]

10

15

20

25

30

35

40

45

50

55

Q [m/h]

NPSH
[m]
NPSH

QH 1450 rpm1/1n

60

QH 1450 rpm2/3

40

0.8

20

0.4

80

1.6
1.2

0.0
0

10

15

20

25

30

35

40

45

50

55

Q [m/h]

TM01 8156 1309

0.0

For information about dimensions of the individual pumps, see page 129.

95

13
CR pumps with 4-pole motor
50 Hz
Performance curves

p
[kPa]
500

H
[m]

CR, CRN 120

7
50

50 Hz
ISO 9906 Annex A

45
6-1
400

40

35

300

5-1

30
4-1
25
3

200

20

15

2-1
100

10
1
5

0
0

P2
[hp]
2.0
1.5

15

20

25

30

35

40

10

45

12

50

55

14

16

65

70

18

75

20

Q [m/h]
Q [l/s]

Eta
[%]

1.6

Eta

80

1.2

P21/1n

60

0.8

0.5

0.4

0.0

0.0

P22/3

40
20
0

10

15

20

25

30

35

40

45

50

55

60

65

70

75

H
[m]

Q [m/h]

NPSH
[m]

80

QH 1450 rpm1/1n

2.0

60

QH 1450 rpm2/3

1.5

40

20

1.0
NPSH

0.5
0.0

10

15

20

25

30

35

40

45

50

55

For information about dimensions of the individual pumps, see page 130.

96

60

P2
[kW]

1.0

p
[kPa]

10

60

65

70

75

Q [m/h]

TM03 9077 1309

13

p
[kPa]
500

H
[m]

Performance curves

CR pumps with 4-pole motor


50 Hz

CR, CRN 150

50

50 Hz
6

ISO 9906 Annex A

45
400

300

40

35

5-2

30

4-1

25

200

20

3-2

15

100

2-1

10
1
1-1
5

0
0

P2
[hp]
2.0
1.5

20

30

40

10

50

12

14

60

16

70

18

20

80

22

90

24

1.6

0.5

0.4

0.0

0.0

28 Q

[l/s]

Eta
[%]
80

Eta
P21/1n

1.2
0.8

Q [m/h]
26

P2
[kW]

1.0

P22/3

60
40
20
0

p
[kPa]

10

10

20

30

40

50

60

70

80

90

H
[m]

Q [m/h]

NPSH
[m]

80

QH 1450 rpm1/1n

60

QH 1450 rpm2/3

40

20

2
1

NPSH

0
0

10

20

30

40

50

60

70

80

90

Q [m/h]

TM03 9078 1309

For information about dimensions of the individual pumps, see page 130.

97

13
CR pumps with 4-pole motor
60 Hz
Performance curves

CR pumps with 4-pole motor

p
[kPa]

H
[m]

CR, CRI, CRN 1

-27

60

60 Hz

500

ISO 9906 Annex A

-25

55
-23

50

-21
45
-19
400

40
-17
35
-15

300

30
-13
-12

25

-11
-10

200

20

-9
-8
-7

15
-6
100

-5

10

-4
-3

5
0

-2

0
0.0

0.1

0.00

P2
[hp]
0.020
0.015

0.2

0.3

0.05

0.4

0.10

0.5

0.6

0.15

0.7

0.8

0.20

0.9

1.0

0.25

1.1

1.2

0.30

1.3

0.35

1.4

0.40

P2
[kW]

0.000

30

Eta
[%]
60

P2
Eta

0.010

40

0.005

20

0.000

0
0.0

p
[kPa]

Q [l/s]

0.015

0.010
0.005

Q [m/h]

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.4

H
[m]

Q [m/h]

NPSH
[m]
1.5

QH 1750 rpm
2

10

1.0
0.5
NPSH

0.0
0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

For information about dimensions of the individual pumps, see page 131.

98

1.1

1.2

1.3

1.4

Q [m/h]

TM02 2540 1309

20

13

p
[kPa]

H
[m]

CR, CRI, CRN 3

-25

60

60 Hz
ISO 9906 Annex A

55
500

-23
-21

50

-19

45
400

-17

40

-15

35
300

Performance curves

CR pumps with 4-pole motor


60 Hz

-13

30

-12
-11

25
200

-10
-9

20

-8
-7

15

-6
-5

100

10

-4
-3

5
0

-2

0
0.0

0.2

0.0

P2
[hp]

P2
[kW]

0.04

0.03

0.03

0.4

0.6

0.1

0.8

0.2

1.0

1.2

0.3

1.4

1.6

0.4

1.8

2.0

0.5

2.2

2.4

0.6

2.6

0.7

0.00

Eta

0.02

Eta
[%]

40

P2
0.01

20

0.00

0
0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

p
H
[kPa] [m]
30

Q [l/s]

60

0.02
0.01

Q [m/h]

Q [m/h]

NPSH
[m]
1.5

QH 1750 rpm
2

10

1.0
NPSH

0.5
0.0

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

Q [m/h]

TM02 2539 1309

20

For information about dimensions of the individual pumps, see page 131.

99

13
CR pumps with 4-pole motor
60 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 5

60

-24

60 Hz
ISO 9906 Annex A

55
500

-22

50

-20

45
400

-18

40

-16

35

-14

30

-12

25

-10

20

-8

15

-6

10

-4

-2

-15

300

-13
-11
-9

200

-7
-5
100

-3

0
0.0

0.5

0.0

P2
[hp]

P2
[kW]

0.04

0.03

0.03

1.0

0.2

1.5

0.4

2.0

2.5

0.6

3.0

0.8

3.5

4.0

1.0

4.5

1.2

5.0

Q [m/h]

1.4

Q [l/s]
Eta
[%]
60

P2
Eta

0.02

40

0.01

20

0.02
0.01
0.00

0.00

0
0.0

p
[kPa]
30

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

Q [m/h]

H
[m]

NPSH
[m]

1.5
QH 1750 rpm

20

10

1.0
0.5

0.0
0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

For information about dimensions of the individual pumps, see page 132.

100

4.0

4.5

5.0

Q [m/h]

TM02 2538 1309

NPSH

13

p
[kPa]

H
[m]

-17

Performance curves

CR pumps with 4-pole motor


60 Hz

CR, CRI, CRN 10

65

60 Hz
600

ISO 9906 Annex A

-16

60
55

-14
500

50
-12

45
400

40
-10
35

300

-9
-8

30

-7
25
-6
200

20

-5
-4

15

-3
100

10

-2
-1

5
0

0
0.0

0.0

P2
[hp]

P2
[kW]

0.08

0.06

0.06

0.5

1.0

0.2

1.5

0.4

2.0

2.5

0.6

3.0

0.8

3.5

4.0

1.0

4.5

1.2

5.0

5.5

1.4

6.0

1.6

6.5

1.8

7.0

7.5

2.0

Q [m/h]
Q [l/s]
P2
Eta

Eta
[%]
60

0.04

40

0.02

20

0.00

0.00

p
[kPa]

H
[m]

0.04

0.0

30

3.0

20

2.0

10

1.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

Q [m/h]
NPSH
[m]

QH 1750 rpm

1.5
1.0
0.5

NPSH
0

0.0

0.0
0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

Q [m/h]

TM02 7276 1309

0.02

For information about dimensions of the individual pumps, see page 132.

101

13
CR pumps with 4-pole motor
60 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRI, CRN 15

-12

60

60 Hz
ISO 9906 Annex A

55
500

-10

50

-9

45
400

-8

40

-7

35
300

-6

30

-5

25
200

-4

20

-3

15
100

-2

10

-1

5
0

0
0

0.0

0.5

1.0

1.5

2.0

10

2.5

11

12

3.0

13

14

3.5

Q [m/h]

4.0

Q [l/s]

P2
[hp]

P2
[kW]

Eta

Eta
[%]

0.20

0.15

P2

60

0.15

0.10

40

0.05

20

0.10
0.05
0.00

0.00

0
0

p
[kPa]
60

10

11

12

13

14

Q [m/h]

H
[m]

NPSH
[m]

1.5
QH 1750 rpm

20

1.0
0.5
NPSH

0.0
0

10

For information about dimensions of the individual pumps, see page 133.

102

11

12

13

14

Q [m/h]

TM02 7277 1309

40

13

p
[kPa]

H
[m]

CR, CRI, CRN 20

55
500

Performance curves

CR pumps with 4-pole motor


60 Hz

-10

60 Hz
ISO 9906 Annex A

50

45
-8
400

40
-7
35
-6

300

30
-5
25
-4

200

20
-3
15
-2
10
-1

0
0

0.0

P2
[hp]
0.3

0.5

1.0

1.5

2.0

10

2.5

11

12

3.0

13

3.5

14

15

4.0

16

4.5

Q [m/h]
Q [l/s]

P2
[kW]

Eta
[%]

0.24

Eta
P2

60

0.2

0.16

40

0.1

0.08

20

0.0

0.00

0
0

p
[kPa]

10

11

12

13

14

15

16

Q [m/h]

H
[m]

60

40

20

NPSH
[m]
3

QH 1750 rpm

2
1
NPSH

0
0

10

11

12

13

14

15

16

Q [m/h]

TM02 7278 1309

100

For information about dimensions of the individual pumps, see page 133.

103

13
CR pumps with 4-pole motor
60 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRN 32

70
10-2

600

60 Hz

-9

65

ISO 9906 Annex A


9-2

60
-8
55

500

8-2
-7

50

7-2
45
400

-6

40

6-2
-5

35
5-2
300

30

-4
4-2

25
-3 200

20

3-2
-2

15
100

2-1
2-2

10

-1
1-1

5
0

0
0

P2 P2 0
[hp] [kW]
0.6
0.4

10

12

14

16

18

20

22

Eta

0.4
0.3

Q [m/h]
Q [l/s]

Eta
[%]

P21/1

80

P22/3

60

0.2

40

0.1

20

0.0

0.0

p
[kPa]

H
[m]

0.2

60

10

12

14

16

20

22

Q [m/h]

NPSH
[m]
4

QH 1750 rpm1/1

3
NPSH

QH 1750 rpm2/3

40

20

0
0

10

12

14

16

For information about dimensions of the individual pumps, see page 134.

104

18

18

20

22

Q [m/h]

TM01 8157 1309

80

13

p
[kPa]

H
[m]

CR, CRN 45

65

7-1

60 Hz

7-2
600

Performance curves

CR pumps with 4-pole motor


60 Hz

ISO 9906 Annex A

60
6
55

6-1
6-2

500

50
5
45

5-1
5-2

400

40
4
4-1

35
300

4-2

30

3
3-1

25
200

3-2

20

2
2-1
2-2

15
100

10

1-1
5
0

0
0

12

16

20

24

P2
P2
[hp] [kW]
1.0

28

32

Q [m/h]
10

Q [l/s]

Eta

0.8

P21/1

Eta
[%]
80

0.8

0.6

0.6

0.4

40

0.2

20

P22/3

60

0.4
0.0

p
[kPa]

0.0

H
[m]

0
0

12

16

20

24

28

32

Q [m/h]

QH 1750 rpm1/1

NPSH
[m]

80

60

1.5

40

1.0

20

QH 1750 rpm2/3

2.0

NPSH

0.5
0.0

12

16

20

24

28

32

Q [m/h]

TM01 8158 1309

0.2

For information about dimensions of the individual pumps, see page 134.

105

13
CR pumps with 4-pole motor
60 Hz
Performance curves

p
[kPa]

H
[m]

CR, CRN 64

5-2

60 Hz

45
4
400

ISO 9906 Annex A

40

4-1
4-2

35
3
300

30

3-1
3-2

25
2
200

20
2-1
2-2

15
1
100

10
1-1
5

0
0

P2
[hp]

10

15

20

25

30

35

10

P2
[kW]

45

Q [m/h]

12

14 Q

[l/s]
Eta
[%]

Eta

1.6
1.6

40

80

1.2

P21/1

60

0.8

P22/3

40

0.8
0.4

20

0.0

0.0

p
[kPa]

H
[m]

10

15

20

25

30

35

45

QH 1750 rpm1/1

10

Q [m/h]
NPSH

NPSH
[m]
2.0

80

60

1.2

40

0.8

20

0.4

0.0

1.6

QH 1750 rpm2/3

10

15

20

25

30

35

For information about dimensions of the individual pumps, see page 135.

106

40

40

45

Q [m/h]

TM01 8159 1309

13

p
[kPa]
400

H
[m]

Performance curves

CR pumps with 4-pole motor


60 Hz

CR, CRN 90
60 Hz

40

4-2

ISO 9906 Annex A

3
35
3-1
300

30
3-2
2

25

200

2-1

20

2-2
15
1
100

10

1-1

0
0

10

P2
[hp]

20

30

40

12

P2
[kW]

60

70

16

Q [m/h]
20

Q [l/s]
Eta
[%]

Eta

2.0
2

50

80

1.5

P21/1

60

1.0

P22/3

40

1
0.5
0.0

0
0

p
[kPa]

H
[m]

120

12

80

40

10

20

30

40

50

60

70

Q [m/h]
NPSH
[m]

QH 1750 rpm1/1
NPSH
QH 1750 rpm2/3

3
2
1
0

10

20

30

40

50

60

70

Q [m/h]

TM01 8160 1309

20

For information about dimensions of the individual pumps, see page 135.

107

13
CR pumps with 4-pole motor
60 Hz
Performance curves

p
[kPa]
500

H
[m]

CR, CRN 120

50

60 Hz
ISO 9906 Annex A

5-2
45
400

40

4-1

35
3
300

30

3-1

25
2
200

20

2-1
2-2

15

1
100

10

0
0

P2
[hp]
2.5

10

15

20

25

30

35

40

10

45

12

50

55

14

60

16

65

70

18

75

20

Q [m/h]
Q [l/s]

P2
[kW]
2.0

Eta
[%]
80

2.0

1.5

P21/1

60

1.5

1.0

P22/3

40

1.0
0.5

0.0

0.0

p
[kPa]

H
[m]

100

10

80

60

40

20

20
Eta
0

0
10

15

20

25

30

35

40

45

50

55

65

70

75

Q [m/h]

QH 1750 rpm1/1

NPSH
[m]
2.5
2.0

QH 1750 rpm2/3

1.5
1.0

NPSH

0.5
0.0

10

15

20

25

30

35

40

45

50

55

For information about dimensions of the individual pumps, see page 135.

108

60

60

65

70

75

Q [m/h]

TM03 9079 1309

0.5

13

p
[kPa]
400

H
[m]

CR, CRN 150


60 Hz

40

4-2

35

300

Performance curves

CR pumps with 4-pole motor


60 Hz

ISO 9906 Annex A

30
3-2
25
2

200

2-1

20

2-2
15
1
100

10
1-1

0
0

P2
[hp]
4

10

20

30

40

10

50

12

14

60

16

70

18

20

80

22

90

24

Q [m/h]
26

P2
[kW]

28 Q

[l/s]

3.2

Eta
[%]
80

2.4

Eta
P21/1

60

1.6

P22/3

40

0.8

0.0

p
[kPa]

H
[m]

20
0
0

10

80

60

40

20

20

30

40

50

60

70

80

90

Q [m/h] NPSH
[m]

12
100

10

3.0

QH 1750 rpm1/1

2.5
QH 1750 rpm2/3

2.0
1.5
1.0

NPSH

0.5
0.0
0

10

20

30

40

50

60

70

80

90

Q [m/h]

TM03 9080 1309

For information about dimensions of the individual pumps, see page 136.

109

14
CR low-NPSH pumps
50 and 60 Hz
Technical data

14. Technical data


CR low-NPSH pumps
Dimensional drawings

D2

B2

D1

G 1/2

B1

FGJ (DIN-ANSI-JIS)
PN 25 / DN 25/32
G 1/2

A (Oval)

19 x 24.5

Rp 1
M10 x 40

G 1/2

100
141
250

35

4 x 13.5

100
145
160

180
220

20

20

50

75

89
100
140

22

75
180
220

4 x 13.5

TM03 1721 2805

G 1/2

CR 1
CR 3

D2

B2

D1

G 1/2

G 1/2

D3

B1

FGJ (DIN-ANSI-JIS)
PN 25 / DN 25/32
G 1/2

A (Oval)

19 x 24.5

Rp 1 1/4"
M10 x 40

G 1/2

110

35
180
220

4 x 13.5

100
145
160

20

100
141
250

20

50

75

89
100
140

22

75
180
220

4 x 13.5

TM03 1723 2805

CR 5

14
Technical data

CR low-NPSH pumps
CR pumps with 4-pole motor
50 and 60 Hz

D2

B2

D1

G 1/2

D3

FJ (DIN-JIS)
PN 16-25 / DN 40
B1

A (oval)

G 1/2

Rp 1 1/2"

G 1/2
39

18 x 20.2

4 x 13.5

20

80

114
150

80

20

4 x 13.5

110
215
256

130
178
280

M12 x 45

27

TM03 1725 2805

G 1/2

CR 10

100
215
256

130
178
200

D2

B2

D1

G 1/2
D3

130
176
300

20

A (oval)
G 1/2
30

20

127
165

65

G 1/2

120
215
256

130
176
300

65
215
256

Rp 2"

M12 x 45

20

18 x 21.5

90

90

125
165

G 1/2

GJ (ANSI-JIS)

18.1

4 x 13.5

130
178
200

130
215
256

TM03 1727 2805

F (DIN)
PN 16-25 / DN 50
B1

CR 15
CR 20

90

G 1/2

D2

B2

D1

D3

CR 32
G 1/2

8 x 18

G 1/2

170
223
320

30

105

107
145
185

G 1/2

4 x 14
74
240
298

TM01 1749 5197

B1

PN16-25-40/DN65

111

14
CR low-NPSH pumps
CR pumps with 4-pole motor
50 and 60 Hz
Technical data

D2

B2

D1

D3

CR 45
G 1/2

8 x 18

G 1/2

140

120
160
200

G 1/2

45

190
248
365

4 x 14

80
266
331

TM01 1751 5197

B1

PN16-25-40/DN80

D2
D1
F (DIN)
PN25-40/DN100

B2

8 x 22

D3

CR 64

45

150
190
235

G 1/2

100

4 x 14

266
331

G 1/2

G 1/2

8 x 18

190
248
365

45

140

150
180
220

G 1/2

100

266
331

4 x 14

TM01 1753 5197

B1

F (DIN)
PN16/DN100

TM01 1755 2203

CR 90

112

14
Technical data

CR pumps with 4-pole motor


50 and 60 Hz

TM03 5999 4106

CR 120
CR 150

113

14
CR low-NPSH pumps
50 Hz
Technical data

CR low-NPSH pump
Dimensions and weights
CR 3 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange
18

CR 3-3

0.37

279

470

254

445

141

109

23

CR 3-4

0.37

297

488

272

463

141

109

23

19

CR 3-5

0.55

315

506

290

481

141

109

24,5

19,5

CR 3-6

0.55

333

524

308

499

141

109

25

20

CR 3-7

0.55

351

542

326

517

141

109

25

21

CR 3-8

0.75

375

606

350

581

141

109

27

23

CR 3-9

0.75

393

624

368

599

141

109

28

23

CR 3-10

0.75

411

642

386

617

141

109

28

24

CR 3-11

1.1

429

660

404

635

141

109

31

26

CR 3-12

1.1

447

678

422

653

141

109

31

26

CR 3-13

1.1

465

696

440

671

141

109

31

27

CR 3-15

1.1

501

732

476

707

141

109

32

28

CR 3-17

1.5

553

834

528

809

178

110

40

36

CR 3-19

1.5

589

870

564

845

178

110

41

37

CR 3-21

2.2

625

946

600

921

178

110

42

38

CR 3-23

2.2

661

982

636

957

178

110

43

39

CR 3-25

2.2

697

1018

178

110

44

CR 3-27

2.2

733

1054

178

110

45

CR 3-29

2.2

769

1090

178

110

46

CR 3-31

3.0

809

1144

198

120

51

CR 3-33

3.0

845

1180

198

120

51

CR 3-36

3.0

899

1234

198

120

53

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

114

14
Technical data

CR low-NPSH pumps
50 Hz

CR 5 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange
21,5

CR 5-4

0.75

333

564

308

539

141

109

26,5

CR 5-5

0.75

366

597

341

572

141

109

27

22

CR 5-6

1.1

393

624

368

599

141

109

30

25

CR 5-7

1.1

420

651

395

626

141

109

30

26

CR 5-8

1.1

447

678

422

653

141

109

31

26

CR 5-9

1.5

490

771

465

746

178

110

38

34

CR 5-10

1.5

517

798

492

773

178

110

39

34

CR 5-11

2.2

544

865

519

840

178

110

40

36

CR 5-12

2.2

571

892

546

867

178

110

41

36

CR 5-13

2.2

598

919

573

894

178

110

41

37

CR 5-14

2.2

625

946

600

921

178

110

42

37

CR 5-15

2.2

652

973

627

948

178

110

43

38

CR 5-16

2.2

679

1000

654

975

178

110

43

38

CR 5-18

3.0

737

1072

712

1047

198

120

48

44

CR 5-20

3.0

791

1126

766

1101

198

120

50

45

CR 5-22

4.0

845

1217

820

1194

220

134

62

56

CR 5-24

4.0

899

1271

220

134

63

CR 5-26

4.0

953

1325

220

134

64

CR 5-29

4.0

1034

1406

220

134

66

CR 5-32

5.5

1145

1536

220

134

300

82

CR 5-36

5.5

1253

1644

220

134

300

84

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 10 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 10-3

1.1

377

608

377

608

141

109

39

37

CR 10-4

1.5

423

704

423

704

178

110

47

45

CR 10-5

2.2

453

734

453

734

178

110

49

46

CR 10-6

2.2

483

764

483

764

178

110

50

47

CR 10-7

3.0

518

853

518

853

198

120

55

52

CR 10-8

3.0

548

883

548

883

198

120

56

53

CR 10-9

4.0

578

950

578

950

220

134

68

65

CR 10-10

4.0

608

980

608

980

220

134

69

66

CR 10-12

4.0

668

1040

668

1040

220

134

71

69

CR 10-14

5.5

760

1151

760

1151

220

134

300

94

91

CR 10-16

5.5

820

1211

820

1211

220

134

300

96

93

CR 10-18

7.5

880

1271

220

134

300

113

CR 10-20

7.5

940

1331

220

134

300

115

CR 10-22

7.5

1000

1391

220

134

300

117

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

115

14
CR low-NPSH pumps
50 Hz
Technical data

CR 15 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 15-2

3.0

415

750

415

750

198

120

54

53

CR 15-3

4.0

465

837

465

837

220

134

66

65

CR 15-4

4.0

510

882

510

882

220

134

68

67

CR 15-5

5.5

555

946

555

946

220

134

75

74

CR 15-6

5.5

632

1023

632

1023

220

134

300

91

90

CR 15-7

7.5

677

1068

677

1068

220

134

300

108

107

CR 15-8

7.5

722

1113

220

134

300

109

CR 15-9

11.0

767

1238

314

204

350

128

CR 15-10

11.0

889

1360

314

204

350

132

CR 15-12

11.0

979

1450

314

204

350

136

CR 15-14

15.0

1069

1540

314

204

350

177

CR 15-17

15.0

1204

1675

314

204

350

177

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 20 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange
49

CR 20-2

3.0

415

736

415

736

178

110

50

CR 20-3

4.0

465

837

465

837

220

134

66

65

CR 20-4

5.5

542

933

542

933

220

134

300

88

87

CR 20-5

7.5

587

978

587

978

220

134

300

102

101

CR 20-6

7.5

632

1023

632

1023

220

134

300

105

104

CR 20-7

11.0

677

1148

677

1148

314

204

300

139

138

CR 20-8

11.0

799

1270

314

204

350

129

CR 20-10

11.0

889

1360

314

204

350

132

CR 20-12

15.0

979

1450

314

204

350

168

CR 20-14

15.0

1069

1540

314

204

350

172

CR 20-17

18.5

1204

1719

314

204

350

199

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

116

14
Technical data

CR low-NPSH pumps
50 Hz

CR 32 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B1+B2

Oval flange
B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 32-2

4.0

575

947

220

134

158

87

CR 32-3-2

5.5

645

1036

220

134

298

107

CR 32-3

5.5

645

1036

220

134

298

107

CR 32-4-2

7.5

715

1106

220

134

298

129

CR 32-4

7.5

715

1106

220

134

298

129

CR 32-5-2

11.0

895

1366

314

204

350

157

CR 32-5

11.0

895

1366

314

204

350

157

CR 32-6-2

11.0

965

1436

314

204

350

160

CR 32-6

11.0

965

1436

314

204

350

160

CR 32-7-2

15.0

1035

1506

314

204

350

195

CR 32-7

15.0

1035

1506

314

204

350

195

CR 32-8-2

15.0

1105

1576

314

204

350

198

CR 32-8

15.0

1105

1576

314

204

350

198

CR 32-9-2

18.5

1175

1690

314

204

350

223

CR 32-9

18.5

1175

1690

314

204

350

223

CR 32-10-2

18.5

1245

1760

314

204

350

226

CR 32-10

18.5

1245

1760

314

204

350

226

CR 32-11-2

22.0

1315

1856

314

204

350

247

CR 32-11

22.0

1315

1856

314

204

350

247

CR 32-12-2

22.0

1385

1926

314

204

350

251

CR 32-12

22.0

1385

1926

314

204

350

251

CR 32-13-2

30.0

1455

2101

415

300

400

322

CR 32-13

30.0

1455

2101

415

300

400

322

CR 32-14-2

30.0

1525

2171

415

300

400

325

CR 32-14

30.0

1525

2171

415

300

400

325

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

117

14
CR low-NPSH pumps
50 Hz
Technical data

CR 45 low-NPSH pumps, 50 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B1+B2

Oval flange
B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 45-2

7.5

639

1030

220

134

298

122

CR 45-3-2

11.0

829

1300

314

204

350

151

CR 45-3

11.0

829

1300

314

204

350

151

CR 45-4-2

15.0

909

1380

314

204

350

189

CR 45-4

15.0

909

1380

314

204

350

189

CR 45-5-2

18.5

989

1504

314

204

350

216

CR 45-5

18.5

989

1504

314

204

350

216

CR 45-6-2

22.0

1069

1610

314

204

350

237

CR 45-6

22.0

1069

1610

314

204

350

237

CR 45-7-2

30.0

1149

1795

415

300

400

321

CR 45-7

30.0

1149

1795

415

300

400

321

CR 45-8-2

30.0

1229

1875

415

300

400

336

CR 45-8

30.0

1229

1875

415

300

400

336

CR 45-9-2

30.0

1309

1955

415

300

400

341

CR 45-9

37.0

1309

2012

415

300

400

361

CR 45-10-2

37.0

1389

2092

415

300

400

366

CR 45-10

37.0

1389

2092

415

300

400

366

CR 45-11-2

45.0

1469

2178

442

325

450

478

CR 45-11

45.0

1469

2178

442

325

450

478

CR 45-12-2

45.0

1549

2258

442

325

450

483

CR 45-12

45.0

1549

2258

442

325

450

483

CR 45-13-2

45.0

1629

2338

442

325

450

488

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 64 low-NPSH pumps, 50 Hz
CR
Pump type

Motor P2 [kW]

DIN flange
B1

B1+B2

Oval flange
B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 64-2-1

11.0

754

1225

314

204

350

151

CR 64-2

11.0

754

1225

314

204

350

151

CR 64-3-2

15.0

836

1307

314

204

350

194

CR 64-3-1

15.0

836

1307

314

204

350

194

CR 64-3

18.5

836

1351

314

204

350

216

CR 64-4-2

18.5

919

1434

314

204

350

226

CR 64-4-1

22.0

919

1460

314

204

350

242

CR 64-4

22.0

919

1460

314

204

350

242

CR 64-5-2

30.0

1001

1647

415

300

400

316

CR 64-5-1

30.0

1001

1647

415

300

400

316

CR 64-5

30.0

1001

1647

415

300

400

316

CR 64-6-2

30.0

1084

1730

415

300

400

336

CR 64-6-1

37.0

1084

1787

415

300

400

356

CR 64-6

37.0

1084

1787

415

300

400

356

CR 64-7-2

37.0

1166

1869

415

300

400

376

CR 64-7-1

37.0

1166

1869

415

300

400

376

CR 64-7

45.0

1166

1875

442

325

450

440

CR 64-8-2

45.0

1249

1958

442

325

450

473

CR 64-8-1

45.0

1249

1958

442

325

450

473

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

118

Net weight [kg]

Dimension [mm]

14
Technical data

CR low-NPSH pumps
60 Hz

CR 3 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 3-3

0.55

279

470

254

445

141

109

24

19

CR 3-4

0.55

297

488

272

463

141

109

24

19

CR 3-5

0.75

321

552

296

527

141

109

26

22

CR 3-6

1.1

339

570

314

545

141

109

29

24

CR 3-7

1.1

357

588

332

563

141

109

29

24

CR 3-8

1.1

375

606

350

581

141

109

29

25

CR 3-9

1.5

409

690

384

665

178

110

37

32

CR 3-10

1.5

427

708

402

683

178

110

37

33

CR 3-11

1.5

445

726

420

701

178

110

38

33

CR 3-12

2.2

463

784

438

759

178

110

39

34

CR 3-13

2.2

481

802

456

777

178

110

39

34

CR 3-15

2.2

517

838

492

813

178

110

40

35

CR 3-17

2.2

553

874

528

849

178

110

41

36

CR 3-19

3.0

593

928

198

120

46

CR 3-21

3.0

629

964

198

120

47

CR 3-23

3.0

665

1000

198

120

47

CR 3-25

4.0

701

1073

220

134

59

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 5 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 5-4

1.1

339

570

314

545

141

109

28

24

CR 5-5

1.5

382

663

357

638

178

110

36

32

CR 5-6

2.2

409

730

384

705

178

110

37

33

CR 5-7

2.2

436

757

411

732

178

110

38

33

CR 5-8

2.2

463

784

438

759

178

110

38

34

CR 5-9

2.2

490

811

465

786

178

110

39

34

CR 5-10

3.0

521

856

496

831

198

120

44

39

CR 5-11

3.0

548

883

523

858

198

120

44

40

CR 5-12

3.0

575

910

550

885

198

120

45

40

CR 5-13

4.0

602

974

577

949

220

134

56

52

CR 5-14

4.0

629

1001

604

976

220

134

57

53

CR 5-15

4.0

656

1028

631

1003

220

134

58

53

CR 5-16

4.0

683

1055

658

1030

220

134

58

54

CR 5-18

5.5

767

1158

220

134

300

74

CR 5-20

5.5

821

1212

220

134

300

75

CR 5-22

5.5

875

1266

220

134

300

76

CR 5-24

7.5

929

1308

220

134

300

79

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

119

14
CR low-NPSH pumps
60 Hz
Technical data

CR 10 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 10-3

2.2

393

674

393

674

198

120

47

44

CR 10-4

3.0

428

763

428

763

198

120

52

49

CR 10-5

4.0

458

830

458

830

220

134

64

61

CR 10-6

4.0

488

860

488

860

220

134

65

62

CR 10-7

5.5

550

941

550

941

220

134

300

87

84

CR 10-8

5.5

580

971

580

971

220

134

300

88

85

CR 10-9

5.5

610

1001

610

1001

220

134

300

89

86

CR 10-10

7.5

640

1019

640

1019

220

134

300

104

101

CR 10-12

7.5

700

1079

220

134

300

106

CR 10-14

11.0

837

1308

314

204

350

129

CR 10-16

11.0

897

1368

314

204

350

131

CR 10-17

11.0

957

1428

314

204

350

133

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 15 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange
70

CR 15-2

5.5

420

811

420

811

220

134

71

CR 15-3

5.5

465

856

465

856

220

134

72

71

CR 15-4

7.5

542

921

542

921

220

134

300

103

102

CR 15-5

11.0

587

1058

587

1058

314

204

300

136

135

CR 15-6

11.0

709

1180

314

204

350

126

CR 15-7

15.0

754

1225

314

204

350

152

CR 15-8

15.0

799

1270

314

204

350

154

CR 15-9

15.0

844

1315

314

204

350

163

CR 15-10

18.5

889

1404

314

204

350

175

CR 15-12

18.5

979

1494

314

204

350

190

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 20 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

DIN flange

Oval flange

CR 20-2

5.5

420

811

420

811

220

134

71

70

CR 20-3

7.5

497

876

497

876

220

134

300

102

101

CR 20-4

11.0

542

1013

542

1013

314

204

350

134

133

CR 20-5

11.0

664

1135

664

1135

314

204

350

124

123

CR 20-6

15.0

709

1180

314

204

350

151

CR 20-7

15.0

754

1225

314

204

350

159

CR 20-8

18.5

799

1314

314

204

350

171

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

120

D3

14
Technical data

CR low-NPSH pumps
60 Hz

CR 32 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

D1

D2

D3

DIN flange

Oval flange
-

CR 32-2-1

5.5

575

966

220

148

298

98

CR 32-2

7.5

575

954

220

134

298

112

CR 32-3-2

11.0

755

1226

314

204

350

146

CR 32-3

11.0

755

1226

314

204

350

146

CR 32-4-2

11.0

825

1296

314

204

350

154

CR 32-4

15.0

825

1296

314

204

350

186

CR 32-5-2

15.0

895

1366

314

204

350

189

CR 32-5

18.5

895

1410

314

204

350

211

CR 32-6-2

18.5

965

1480

314

204

350

214

CR 32-6

18.5

965

1480

314

204

350

214

CR 32-7-2

22.0

1035

1576

314

204

350

233

CR 32-7

22.0

1035

1576

314

204

350

233

CR 32-8-2

30.0

1105

1751

415

300

400

305

CR 32-8

30.0

1105

1751

415

300

400

305

CR 32-9-2

30.0

1175

1821

415

300

400

308

CR 32-9

30.0

1175

1821

415

300

400

308

CR 32-10-2

30.0

1245

1891

415

300

400

311

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 45 low-NPSH pumps, 60 Hz
CR
Pump type

Net weight [kg]

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B1+B2

Oval flange
B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 45-2-1

11.0

749

1220

314

204

350

147

CR 45-2

15.0

749

1220

314

204

350

179

CR 45-3-2

18.5

829

1344

314

204

350

205

CR 45-3-1

18.5

829

1344

314

204

350

205

CR 45-3

18.5

829

1344

314

204

350

205

CR 45-4-2

22.0

909

1450

314

204

350

227

CR 45-4-1

30.0

909

1555

415

300

400

296

CR 45-4

30.0

909

1555

415

300

400

296

CR 45-5-2

30.0

989

1635

415

300

400

301

CR 45-5-1

30.0

989

1635

415

300

400

301

CR 45-5

30.0

989

1635

415

300

400

301

CR 45-6-2

37.0

1069

1772

415

300

400

326

CR 45-6-1

37.0

1069

1772

415

300

400

326

CR 45-6

37.0

1069

1772

415

300

400

326

CR 45-7-2

45.0

1149

1858

442

325

450

405

CR 45-7-1

45.0

1149

1858

442

325

450

405

CR 45-7

45.0

1149

1858

442

325

450

405

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

121

14
CR low-NPSH pumps
60 Hz
Technical data

CR 64 low-NPSH pumps, 60 Hz
CR
Pump type

Motor P2 [kW]

DIN flange
B1

B1+B2

Oval flange
B1

B1+B2

D1

D2

D3

DIN flange

Oval flange

CR 64-2-1

18.5

754

1269

314

204

350

205

CR 64-2

22.0

754

1295

314

204

350

221

CR 64-3-2

22.0

836

1377

314

204

350

232

CR 64-3-1

30.0

836

1482

415

300

400

301

CR 64-3

30.0

836

1482

415

300

400

301

CR 64-4-2

37.0

919

1622

415

300

400

331

CR 64-4-1

37.0

919

1622

415

300

400

331

CR 64-4

45.0

919

1628

442

325

450

395

CR 64-5-2

45.0

1001

1710

442

325

450

400

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

122

Net weight [kg]

Dimension [mm]

14
Technical data

CR pumps with 4-pole motor


50 Hz

CR pumps with 4-pole motor


Dimensions and weights
CR 1 with 4-pole motor, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 1-2

0,25

279

470

254

445

141

109

160

22

17

CR 1-3

0,25

279

470

254

445

141

109

160

22

17

CR 1-4

0,25

297

488

272

463

141

109

160

22

18

CR 1-5

0,25

315

506

290

481

141

109

160

23

18

CR 1-6

0,25

333

524

308

499

141

109

160

23

19

CR 1-7

0,25

351

542

326

517

141

109

160

24

19

CR 1-8

0,25

369

560

344

535

141

109

160

25

20

CR 1-9

0,25

387

578

362

553

141

109

160

25

20

CR 1-10

0,25

405

596

380

571

141

109

160

25

21

CR 1-11

0,25

423

614

398

589

141

109

160

26

21

CR 1-12

0,25

447

638

422

613

141

109

160

28

23

CR 1-13

0,25

465

656

440

631

141

109

160

28

24

CR 1-15

0,25

501

692

476

667

141

109

160

29

25

CR 1-17

0,25

537

728

512

703

141

109

160

32

28

CR 1-19

0,25

573

764

548

739

141

109

160

33

28

CR 1-21

0,25

609

800

584

775

141

109

160

34

29

CR 1-23

0,25

645

836

620

811

141

109

160

35

30

CR 1-25

0,25

697

888

141

109

160

43

CR 1-27

0,25

733

924

141

109

160

43

CR 1-30

0,25

787

978

141

109

160

45

CR 1-33

0,25

841

1032

141

109

160

46

CR 1-36

0,25

895

1086

141

109

160

48

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

123

14
CR pumps with 4-pole motor
50 Hz
Technical data

CR 3 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 3-2

0,25

279

470

254

445

141

109

160

22

17

CR 3-3

0,25

279

470

254

445

141

109

160

22

17

CR 3-4

0,25

297

488

272

463

141

109

160

22

18

CR 3-5

0,25

315

506

290

481

141

109

160

23

18

CR 3-6

0,25

333

524

308

499

141

109

160

24

19

CR 3-7

0,25

351

542

326

517

141

109

160

24

20

CR 3-8

0,25

375

566

350

541

141

109

160

26

22

CR 3-9

0,25

393

584

368

559

141

109

160

27

22

CR 3-10

0,25

411

602

386

577

141

109

160

27

23

CR 3-11

0,25

429

620

404

595

141

109

160

30

25

CR 3-12

0,25

447

638

422

613

141

109

160

30

25

CR 3-13

0,25

465

656

440

631

141

109

160

30

26

CR 3-15

0,25

501

692

476

667

141

109

160

31

27

CR 3-17

0,25

553

744

528

719

141

109

160

39

35

CR 3-19

0,25

589

780

564

755

141

109

160

40

36

CR 3-21

0,25

625

816

600

791

141

109

160

41

37

CR 3-23

0,25

661

852

636

827

141

109

160

42

38

CR 3-25

0,25

697

888

141

109

160

43

CR 3-27

0,25

733

924

141

109

160

44

CR 3-29

0,37

769

960

141

109

160

46

CR 3-31

0,37

809

1000

141

109

160

51

CR 3-33

0,37

845

1036

141

109

160

51

CR 3-36

0,37

899

1090

141

109

160

53

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

124

14
Technical data

CR pumps with 4-pole motor


50 Hz

CR 5 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 5-2

0,25

279

470

254

445

141

109

160

22

17

CR 5-3

0,25

306

497

281

472

141

109

160

23

19

CR 5-4

0,25

333

524

308

499

141

109

160

24

19

CR 5-5

0,25

366

557

341

532

141

109

160

26

21

CR 5-6

0,25

393

584

368

559

141

109

160

29

24

CR 5-7

0,25

420

611

395

586

141

109

160

29

25

CR 5-8

0,25

447

638

422

613

141

109

160

30

25

CR 5-9

0,25

490

681

465

656

141

109

160

37

33

CR 5-10

0,25

517

708

492

683

141

109

160

38

33

CR 5-11

0,25

544

735

519

710

141

109

160

39

35

CR 5-12

0,25

571

762

546

737

141

109

160

40

35

CR 5-13

0,25

598

789

573

764

141

109

160

40

36

CR 5-14

0,25

625

816

600

791

141

109

160

41

36

CR 5-15

0,25

652

843

627

818

141

109

160

42

37

CR 5-16

0,37

679

870

654

845

141

109

160

43

38

CR 5-18

0,37

737

928

712

903

141

109

160

48

44

CR 5-20

0,37

791

982

766

957

141

109

160

50

45

CR 5-22

0,37

845

1036

820

1011

141

109

160

62

56

CR 5-24

0,55

899

1130

141

109

200

62

CR 5-26

0,55

953

1184

141

109

200

63

CR 5-29

0,55

1034

1265

141

109

200

65

CR 5-32

0,55

1145

1376

141

109

200

81

CR 5-36

0,75

1253

1534

178

109

200

83

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 10 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 10-1

0,25

343

534

343

534

141

109

160

33

30

CR 10-2

0,25

347

538

347

538

141

109

160

35

33

CR 10-3

0,25

377

568

377

568

141

109

160

38

36

CR 10-4

0,25

423

614

423

614

141

109

160

46

44

CR 10-5

0,25

453

644

453

644

141

109

160

48

45

CR 10-6

0,25

483

674

483

674

141

109

160

49

46

CR 10-7

0,37

518

709

518

709

141

109

160

55

52

CR 10-8

0,37

548

739

548

739

141

109

160

56

53

CR 10-9

0,37

578

769

578

769

141

109

160

57

54

CR 10-10

0,55

608

839

608

839

141

109

200

68

65

CR 10-12

0,6

668

899

668

899

141

109

200

70

68

CR 10-14

0,75

760

1041

760

1041

178

109

200

93

90

CR 10-16

0,75

820

1101

820

1101

178

109

200

95

92

CR 10-18

0,75

880

1161

178

109

200

100

CR 10-20

1,1

940

1261

178

110

200

98

CR 10-22

1,1

1000

1321

178

110

200

100

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

125

14
CR pumps with 4-pole motor
50 Hz
Technical data

CR 15 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 15-1

0,25

400

591

400

591

141

109

160

41

40

CR 15-2

0,25

415

606

415

606

141

109

160

49

48

CR 15-3

0,37

465

656

465

656

141

109

160

55

54

CR 15-4

0,55

510

741

510

741

141

109

200

67

66

CR 15-5

0,55

555

786

555

786

141

109

200

68

67

CR 15-6

0,75

632

913

632

913

178

109

200

90

89

CR 15-7

0,75

677

958

677

958

178

109

200

92

91

CR 15-8

1,1

722

1043

178

110

200

92

CR 15-9

1,1

767

1088

178

110

200

93

CR 15-10

1,1

889

1210

178

110

200

125

CR 15-12

1,5

979

1260

178

110

200

134

CR 15-14

1,5

1069

1350

178

110

200

138

CR 15-17

2,2

1204

1525

198

120

250

157

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 20 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 20-1

0,25

400

591

400

591

141

109

160

41

40

CR 20-2

0,37

415

606

415

606

141

109

160

50

49

CR 20-3

0,55

465

696

465

696

141

109

200

65

64

CR 20-4

0,6

542

773

542

773

141

109

200

87

86

CR 20-5

0,75

587

868

587

868

178

109

200

89

88

CR 20-6

1,1

632

953

632

953

178

110

200

88

CR 20-7

1,1

677

998

677

998

178

110

200

90

CR 20-8

1,1

799

1120

178

110

200

122

CR 20-10

1,5

889

1170

178

110

200

130

CR 20-12

2,2

979

1300

198

120

250

148

CR 20-14

2,2

1069

1390

198

120

250

152

CR 20-17

2,2

1204

1525

198

120

250

187

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

126

14
Technical data

CR pumps with 4-pole motor


50 Hz

CR 32 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 32-1-1

1,5

505

786

178

110

200

DIN flange
61

Oval flange
-

CR 32-1

1,5

505

786

178

110

200

62

CR 32-2-2

1,5

575

856

178

110

200

76

CR 32-2

1,5

575

856

178

110

200

87

CR 32-3-2

1,5

645

926

178

110

200

107

CR 32-3

1,5

645

926

178

110

200

107

CR 32-4-2

1,5

715

996

178

110

200

117

CR 32-4

1,5

715

996

178

110

200

117

CR 32-5-2

1,5

895

1176

178

110

200

155

CR 32-5

1,5

895

1176

178

110

200

155

CR 32-6-2

1,5

965

1246

178

110

200

158

CR 32-6

1,5

965

1246

178

110

200

158

CR 32-7-2

1,5

1035

1316

178

110

200

175

CR 32-7

1,5

1035

1316

178

110

200

175

CR 32-8-2

2,2

1105

1426

198

120

250

178

CR 32-8

2,2

1105

1426

198

120

250

178

CR 32-9-2

2,2

1175

1496

198

120

250

211

CR 32-9

2,2

1175

1496

198

120

250

211

CR 32-10-2

2,2

1245

1566

198

120

250

214

CR 32-10

2,2

1245

1566

198

120

250

214

CR 32-11-2

2,2

1315

1636

198

120

250

250

CR 32-11

1315

1650

198

120

250

249

CR 32-12-2

1385

1720

198

120

250

253

CR 32-12

1385

1720

198

120

250

253

CR 32-13-2

1455

1790

198

120

250

321

CR 32-13

1455

1790

198

120

250

321

CR 32-14-2

1525

1860

198

120

250

324

CR 32-14

1525

1860

198

120

250

324

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

127

14
CR pumps with 4-pole motor
50 Hz
Technical data

CR 45 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

D2

D3

B1

B1+B2

B1

B1+B2

CR 45-1-1

1,5

559

840

178

110

200

80

CR 45-1

1,5

559

840

178

110

200

91

CR 45-2-2

1,5

639

920

178

110

200

108

CR 45-2

1,5

639

920

178

110

200

110

CR 45-3-2

1,5

829

1110

178

110

200

149

DIN flange

Oval flange

CR 45-3

1,5

829

1110

178

110

200

149

CR 45-4-2

1,5

909

1190

178

110

200

169

CR 45-4

2,2

909

1230

198

120

250

169

CR 45-5-2

2,2

989

1310

198

120

250

204

CR 45-5

2,2

989

1310

198

120

250

204

CR 45-6-2

1069

1404

198

120

250

239

CR 45-6

1069

1404

198

120

250

239

CR 45-7-2

1149

1484

198

120

250

320

CR 45-7

1149

1484

198

120

250

320

CR 45-8-2

1229

1601

220

134

250

336

CR 45-8

1229

1601

220

134

250

336

CR 45-9-2

1309

1681

220

134

250

341

CR 45-9

1309

1681

220

134

250

361

CR 45-10-2

1389

1761

220

134

250

366

CR 45-10

1389

1761

220

134

250

366

CR 45-11-2

5,5

1469

1860

260

159

300

487

CR 45-11

5,5

1469

1860

260

159

300

487

CR 45-12-2

5,5

1549

1940

260

159

300

492

CR 45-12

5,5

1549

1940

260

159

300

492

CR 45-13-2

5,5

1629

2020

260

159

300

497

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

128

Net weight [kg]


D1

14
Technical data

CR pumps with 4-pole motor


50 Hz

CR 64 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 64-1-1

1,5

561

842

178

110

200

DIN flange
91

Oval flange
-

CR 64-1

1,5

561

842

178

110

200

102

CR 64-2-2

1,5

644

925

178

110

200

114

CR 64-2-1

1,5

754

1035

178

110

200

149

CR 64-2

1,5

754

1035

178

110

200

149

CR 64-3-2

2,2

836

1157

198

120

250

174

CR 64-3-1

2,2

836

1157

198

120

250

174

CR 64-3

2,2

836

1157

198

120

250

204

CR 64-4-2

919

1254

198

120

250

213

CR 64-4-1

919

1254

198

120

250

244

CR 64-4

919

1254

198

120

250

244

CR 64-5-2

1001

1336

198

120

250

315

CR 64-5-1

1001

1373

220

134

250

316

CR 64-5

1001

1373

220

134

250

316

CR 64-6-2

1084

1456

220

134

250

336

CR 64-6-1

1084

1456

220

134

250

356

CR 64-6

1084

1456

220

134

250

356

CR 64-7-2

5,5

1166

1557

260

159

300

385

CR 64-7-1

5,5

1166

1557

260

159

300

385

CR 64-7

5,5

1166

1557

260

159

300

449

CR 64-8-2

5,5

1249

1640

260

159

300

482

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 90 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 90-1-1

1,5

571

852

178

110

200

DIN flange
80,4

Oval flange
-

CR 90-1

1,5

571

852

178

110

200

80,4

CR 90-2-2

1,5

773

1054

178

110

200

85,3

CR 90-2

2,2

773

1094

198

120

250

85,6

CR 90-3-2

2,2

865

1186

198

120

250

90,7

CR 90-3

865

1200

198

120

250

94,7

CR 90-4-2

957

1329

220

134

250

110,7

CR 90-4

957

1329

220

134

250

110,7

CR 90-5-2

1049

1421

220

134

250

117,2

CR 90-5

5,5

1049

1440

260

159

300

128,4

CR 90-6-2

5,5

1141

1532

260

159

300

134,1

CR 90-6

5,5

1141

1532

260

159

300

133,4

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

129

14
CR pumps with 4-pole motor
50 Hz
Technical data

CR 120 with 4-pole motor, 50 HZ


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 120-1

1,5

834

1115

178

110

200

113

CR 120-2-1

2,2

990

1311

198

120

250

131

CR 120-2

990

1325

198

120

250

133

CR 120-3

1145

1517

220

134

250

148

CR 120-4-1

5,5

1301

1692

260

159

300

185

CR 120-5-1

5,5

1456

1847

260

159

300

194

CR 120-6-1

7,5

1642

2071

260

159

300

220

CR 120-7

11

1797

2268

314

204

350

267

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 150 with 4-pole motor, 50 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

D2

D3

B1

B1+B2

B1

B1+B2

CR 150-1-1

1,5

834

1115

178

110

200

113

CR 150-1

2,2

834

1155

198

120

250

122

CR 150-2-1

990

1325

198

120

250

133

CR 150-3-2

1145

1517

220

134

250

148

DIN flange

Oval flange

CR 150-3

5,5

1145

1536

260

159

300

175

CR 150-4-1

5,5

1301

1692

260

159

300

184

CR 150-5-2

7,5

1486

1915

260

159

300

210

CR 150-6

11

1642

2113

314

204

350

258

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

130

Net weight [kg]


D1

14
Technical data

CR pumps with 4-pole motor


60 Hz

CR 1 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 1-2

0,25

279

470

254

445

141

109

105

22

17

CR 1-3

0,25

279

470

254

445

141

109

105

22

17

CR 1-4

0,25

297

488

272

463

141

109

105

22

18

CR 1-5

0,25

315

506

290

481

141

109

105

23

19

CR 1-6

0,25

333

524

308

499

141

109

105

24

19

CR 1-7

0,25

357

548

332

523

141

109

105

26

21

CR 1-8

0,25

375

566

350

541

141

109

105

26

22

CR 1-9

0,25

393

584

368

559

141

109

105

27

22

CR 1-10

0,25

411

602

386

577

141

109

105

29

25

CR 1-11

0,25

429

620

404

595

141

109

105

30

25

CR 1-12

0,25

447

638

422

613

141

109

105

30

25

CR 1-13

0,25

465

656

440

631

141

109

105

30

26

CR 1-15

0,25

517

708

492

683

141

109

105

38

34

CR 1-17

0,25

553

744

528

719

141

109

105

39

35

CR 1-19

0,25

589

780

141

109

105

41

CR 1-21

0,25

625

816

141

109

105

41

CR 1-23

0,25

661

852

141

109

105

42

CR 1-25

0,25

697

888

141

109

105

43

CR 1-27

0,37

737

928

141

109

105

49

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 3 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 3-2

0,25

279

470

254

445

141

109

105

22

17

CR 3-3

0,25

279

470

254

445

141

109

105

23

18

CR 3-4

0,25

297

488

272

463

141

109

105

23

18

CR 3-5

0,25

321

512

296

487

141

109

105

25

21

CR 3-6

0,25

339

530

314

505

141

109

105

28

23

CR 3-7

0,25

357

548

332

523

141

109

105

28

23

CR 3-8

0,25

375

566

350

541

141

109

105

28

24

CR 3-9

0,25

409

600

384

575

141

109

105

36

31

CR 3-10

0,25

427

618

402

593

141

109

105

36

32

CR 3-11

0,25

445

636

420

611

141

109

105

37

32

CR 3-12

0,25

463

654

438

629

141

109

105

38

33

CR 3-13

0,25

481

672

456

647

141

109

105

38

33

CR 3-15

0,25

517

708

492

683

141

109

105

39

34

CR 3-17

0,37

553

744

528

719

141

109

105

41

36

CR 3-19

0,37

593

784

141

109

105

46

CR 3-21

0,37

629

820

141

109

105

47

CR 3-23

0,37

665

856

141

109

105

47

CR 3-25

0,55

701

932

141

109

120

58

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

131

14
CR pumps with 4-pole motor
60 Hz
Technical data

CR 5 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 5-2

0,25

279

470

254

445

141

109

105

22

18

CR 5-3

0,25

312

503

287

478

141

109

105

27

22

CR 5-4

0,25

339

530

314

505

141

109

105

27

23

CR 5-5

0,25

382

573

357

548

141

109

105

35

31

CR 5-6

0,25

409

600

384

575

141

109

105

36

32

CR 5-7

0,25

436

627

411

602

141

109

105

37

32

CR 5-8

0,25

463

654

438

629

141

109

105

37

33

CR 5-9

0,25

490

681

465

656

141

109

105

38

33

CR 5-10

0,37

521

712

496

687

141

109

105

44

39

CR 5-11

0,37

548

739

523

714

141

109

105

44

40

CR 5-12

0,37

575

766

550

741

141

109

105

45

40

CR 5-13

0,37

602

793

577

768

141

109

105

56

52

CR 5-14

0,55

629

860

604

835

141

109

120

56

52

CR 5-15

0,55

656

887

631

862

141

109

120

57

52

CR 5-16

0,55

683

914

658

889

141

109

120

57

53

CR 5-18

0,55

767

998

141

109

120

73

CR 5-20

0,75

821

1052

141

109

120

74

CR 5-22

0,75

875

1106

141

109

120

75

CR 5-24

0,75

929

1160

141

109

120

78

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 10 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 10-1

0,25

347

538

347

538

141

109

105

35

32

CR 10-2

0,25

363

554

363

554

141

109

105

44

42

CR 10-3

0,25

393

584

393

584

141

109

105

46

43

CR 10-4

0,37

428

619

428

619

141

109

105

52

49

CR 10-5

0,37

458

649

458

649

141

109

105

53

50

CR 10-6

0,55

488

719

488

719

141

109

120

64

61

CR 10-7

0,55

550

781

550

781

141

109

120

86

83

CR 10-8

0,75

580

811

580

811

141

109

120

87

84

CR 10-9

0,75

610

841

610

841

141

109

120

88

85

CR 10-10

0,75

640

871

640

871

141

109

120

91

88

CR 10-12

1,1

700

981

178

110

135

89

CR 10-14

1,1

837

1118

178

110

135

122

CR 10-16

1,5

897

1178

178

110

135

129

CR 10-17

1,5

957

1238

178

110

135

131

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

132

14
Technical data

CR pumps with 4-pole motor


60 Hz

CR 15 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 15-1

0,25

415

606

415

606

141

109

105

48

47

CR 15-2

0,37

420

611

420

611

141

109

105

54

53

CR 15-3

0,55

465

696

465

696

141

109

120

65

64

CR 15-4

0,75

542

773

542

773

141

109

120

87

86

CR 15-5

1,1

587

868

587

868

178

110

135

87

86

CR 15-6

1,1

709

990

178

110

135

119

CR 15-7

1,5

754

1035

178

110

135

125

CR 15-8

1,5

799

1080

178

110

135

127

CR 15-9

2,2

844

1179

198

120

160

143

CR 15-10

2,2

889

1224

198

120

160

145

CR 15-12

2,2

979

1314

198

120

160

178

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

CR 20 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 20-1

0,25

415

606

415

606

141

109

105

49

48

CR 20-2

0,55

420

651

420

651

141

109

120

64

63

CR 20-3

0,75

497

728

497

728

141

109

120

86

85

CR 20-4

1,1

542

823

542

823

178

110

135

85

84

CR 20-5

1,5

664

945

664

945

178

110

135

122

121

CR 20-6

1,5

709

990

178

110

135

124

CR 20-7

2,2

754

1089

198

120

160

139

CR 20-8

2,2

799

1134

198

120

160

141

CR 20-10

889

1224

198

120

160

174

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection.
For information about electrical data, see pages 160 to 161.

133

14
CR pumps with 4-pole motor
60 Hz
Technical data

CR 32 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 32-1-1

1,5

505

786

178

110

135

DIN flange
62

Oval flange
-

CR 32-1

1,5

505

786

178

110

135

66

CR 32-2-2

1,5

575

856

178

110

135

98

CR 32-2-1

1,5

575

856

178

110

135

98

CR 32-2

1,5

575

856

178

110

135

100

CR 32-3-2

1,5

755

1036

178

110

135

144

CR 32-3

1,5

755

1036

178

110

135

144

CR 32-4-2

1,5

825

1106

178

110

135

152

CR 32-4

2,2

825

1160

198

120

160

166

CR 32-5-2

2,2

895

1230

198

120

160

169

CR 32-5

2,2

895

1230

198

120

160

199

CR 32-6-2

2,2

965

1300

198

120

160

202

CR 32-6

2,2

965

1300

198

120

160

202

CR 32-7-2

1035

1370

198

120

160

235

CR 32-7

1035

1370

198

120

160

235

CR 32-8-2

1105

1440

198

120

160

304

CR 32-8

1105

1440

198

120

160

304

CR 32-9-2

1175

1547

220

134

160

308

CR 32-9

1175

1547

220

134

160

308

CR 32-10-2

1245

1617

220

134

160

311

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 45 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

D2

D3

B1

B1+B2

B1

B1+B2

CR 45-1-1

1,5

559

840

178

110

135

102

CR 45-1

1,5

559

840

178

110

135

104

CR 45-2-2

1,5

749

1030

178

110

135

145

CR 45-2-1

1,5

749

1030

178

110

135

145

CR 45-2

2,2

749

1084

198

120

160

159

CR 45-3-2

2,2

829

1164

198

120

160

193

CR 45-3-1

2,2

829

1164

198

120

160

193

CR 45-3

2,2

829

1164

198

120

160

193

CR 45-4-2

909

1244

198

120

160

229

CR 45-4-1

909

1244

198

120

160

295

CR 45-4

909

1244

198

120

160

295

CR 45-5-2

989

1361

220

134

160

301

CR 45-5-1

989

1361

220

134

160

301

CR 45-5

989

1361

220

134

160

301

CR 45-6-2

1069

1441

220

134

160

326

CR 45-6-1

5,5

1069

1448

260

159

300

335

CR 45-6

5,5

1069

1448

260

159

300

335

CR 45-7-2

5,5

1149

1528

260

159

300

414

CR 45-7-1

5,5

1149

1528

260

159

300

414

CR 45-7

5,5

1149

1528

260

159

300

414

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

134

Net weight [kg]


D1

DIN flange

Oval flange

14
Technical data

CR pumps with 4-pole motor


60 Hz

CR 64 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 64-1-1

1,5

561

842

178

110

135

DIN flange
104

Oval flange
-

CR 64-1

1,5

671

952

178

110

135

139

CR 64-2-2

2,2

754

1089

198

120

160

163

CR 64-2-1

2,2

754

1089

198

120

160

193

CR 64-2

754

1089

198

120

160

223

CR 64-3-2

836

1171

198

120

160

234

CR 64-3-1

836

1208

220

134

160

301

CR 64-3

836

1208

220

134

160

301

CR 64-4-2

919

1291

220

134

160

331

CR 64-4-1

5,5

919

1298

260

159

300

340

CR 64-4

5,5

919

1298

260

159

300

404

CR 64-5-2

5,5

1001

1380

260

159

300

409

Note: 4-pole CR 64 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 90 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

CR 90-1-1

1,5

681

962

178

110

135

DIN flange
144

Oval flange
-

CR 90-1

2,2

681

1016

198

120

160

158

CR 90-2-2

773

1108

198

120

160

193

CR 90-2-1

773

1108

198

120

160

224

CR 90-2

773

1145

220

134

160

291

CR 90-3-2

865

1237

220

134

160

331

CR 90-3-1

5,5

865

1244

260

159

300

340

CR 90-3

5,5

865

1244

260

159

300

404

CR 90-4-2

5,5

957

1336

260

159

300

419

Note: 4-pole pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

CR 120 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

Net weight [kg]


D1

D2

D3

B1

B1+B2

B1

B1+B2

DIN flange

Oval flange

CR 120-1

2,2

834

1169

198

120

270

119

CR 120-2-2

990

1325

198

120

270

134

CR 120-2-1

990

1362

220

134

270

143

CR 120-2

5,5

990

1369

260

159

300

148

CR 120-3-1

5,5

1145

1524

260

159

300

153

CR 120-3

7,5

1175

1604

260

159

300

168

CR 120-4-1

11

1331

1802

314

204

350

209

CR 120-5-2

11

1486

1957

314

204

350

218

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

135

14
CR pumps with 4-pole motor
60 Hz
Technical data

CR 150 with 4-pole motor, 60 Hz


CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

D2

D3

B1

B1+B2

B1

B1+B2

CR 150-1-1

2,2

834

1169

198

120

270

119

CR 150-1

834

1169

198

120

270

125

DIN flange

Oval flange

CR 150-2-2

990

1362

220

134

270

144

CR 150-2-1

5,5

990

1369

260

159

300

149

CR 150-2

5,5

990

1369

260

159

300

149

CR 150-3-2

7,5

1175

1604

260

159

300

168

CR 150-3

11

1175

1646

314

204

350

199

CR 150-4-2

11

1331

1802

314

204

350

208

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection.
For information about electrical data, see pages 160 to 161.

136

Net weight [kg]


D1

15
Technical data

CR deep-well pumps
50 and 60 Hz

15. Technical data


CR deep-well pumps
Dimensional drawing

Air vent screw G 1/8"

Priming plug G 1

TM03 8261 0907

CR 5

137

15
CR deep-well pumps
50 and 60 Hz
Technical data

CR deep-well pumps, 50 Hz
Dimensions and weights
Dimensions [mm]

Motor
P2
[kW]

B1

B1+B2

C1

D1

D2

CR(I) 5-9

1.5

465

746

85

178

110

CR(I) 5-11

2.2

519

840

85

178

110

CR(I) 5-13

2.2

573

894

85

178

110

CR(I) 5-15

2.2

627

948

85

178

110

Pump

Suction
depth
[m]
54
42
35
27
65
50
45
40
35
28
79
63
54
45
40
33
93
73
62
53
46
37

Pipe dimensions [mm]


Largest
Flow
Pressure class,
ejector
rate Ejector
plastic pipe
Ejector inlet:
Ejector outlet: diameter
No
[m3/h]
[kp/cm2]
external/internal external/internal
[mm]
0.25
0.68
0.92
1.25
0.25
0.62
0.85
1.10
1.37
1.75
0.25
0.62
0.87
1.17
1.39
1.99
0.25
0.63
0.88
1.14
1.40
1.99

11
29
20
22
11
29
20
22
44
45
11
29
20
22
44
45
11
29
20
22
44
45

6+6
6+6
6+6
6+6
10+10
10+6
6+6
6+6
6+6
6+6
10+10
10+10
10+6
10+6
6+6
6+6
10+10
10+10
10+10
10+6
10+6
10+6

32/26
32/26
32/26
32/26
32/22.8
32/22.8
32/26
32/26
32/26
32/26
32/22.8
32/22.8
32/22.8
32/22.8
32/26
32/26
32/22.8
32/22.8
32/22.8
32/22.8
32/22.8
32/22.8

40/32.6
40/32.6
40/32.6
40/32.6
40/28.4
40/32.6
40/32.6
40/32.6
40/32.6
40/32.6
40/28.4
40/28.4
40/32.6
40/32.6
40/32.6
40/32.6
40/28.4
40/28.4
40/28.4
40/32.6
40/32.6
40/32.6

76
76
76
76
80
76
76
76
76
76
80
80
76
76
76
76
80
80
80
76
76
76

Note: For information about electrical data, see pages 160 to 161.

CR deep-well pumps, 60 Hz
Dimensions and weights
Dimensions [mm]

Motor
P2
[kW]

B1

B1+B2

C1

D1

D2

CR(I) 5-6

2.2

384

705

85

179

110

CR(I) 5-8

2.2

438

759

85

179

110

CR(I) 5-9

2.2

465

786

85

179

110

Pump

Suction
depth,
[m]

Flow
rate
[m3/h]

Ejector
No

52
45
41
37
34
30
65
60
53
50
45
73
65
60
55
50
47

0.33
0.69
0.91
1.16
1.35
1.65
0.38
0.60
0.94
1.10
1.37
0.37
0.68
0.88
1.11
1.39
1.63

11
29
20
22
44
45
11
29
20
22
44
11
29
20
22
44
45

Note: For information about electrical data, see pages 160 to 161.

138

Pipe dimensions [mm]


Largest
Pressure class,
ejector
plastic pipe
Ejector inlet:
Ejector outlet: diameter
[kp/cm2]
external/internal external/internal
[mm]
6+6
6+6
6+6
6+6
6+6
6+6
10+10
10+6
6+6
6+6
6+6
10+10
10+10
10+6
10+6
6+6
6+6

32/26
32/26
32/26
32/26
32/26
32/26
32/22.8
32/22.8
32/26
32/26
32/26
32/22.8
32/22.8
32/22.8
32/22.8
32/26
32/26

40/32.6
40/32.6
40/32.6
40/32.6
40/32.6
40/32.6
40/28.4
40/32.6
40/32.6
40/32.6
40/32.6
40/28.4
40/28.4
40/32.6
40/32.6
40/32.6
40/32.6

76
76
76
76
76
76
80
76
76
76
76
80
80
76
76
76
76

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


50 and 60 Hz

16. Technical data


CRN pumps with magnetic drive
Dimensional drawings

TM03 9137 3407

CRN 1
CRN 3

TM03 9138 3407

CRN 5

139

16
CRN pumps with magnetic drive (MAGdrive)
50 and 60 Hz
Technical data
TM03 9140 3407

CRN 10

TM03 9139 3407

CRN 15
CRN 20

D2

B2

D1

D3

CRN 32
G 1/2

8 x 18

G 1/2

170
226
320

140

30

105

107
145
185

G 1/2

4 x 14
74
240
298

TM01 1750 2203

B1

PN16-25-40/DN65

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


50 and 60 Hz

D2

B2

D1

D3

CRN 45
G 1/2

8 x 18

140

120
160
200

G 1/2

45

190
251
365

4 x 14

80
266
331

TM01 1752 2203

B1

PN16-25-40/DN80
G 1/2

D2
D1
F (DIN)
PN25-40/DN100

B2

8 x 22

D3

45

CRN 64

150
190
235

G 1/2

4 x 14

100

266
331

G 1/2

G 1/2

8 x 18

140

150
180
220

G 1/2

45

190
251
365

4 x 14

100

266
331

TM01 1754 0904

B1

F (DIN)
PN16/DN100

D2
D1
F (DIN)
PN25-40/DN100

B2

8 x 22

D3

CRN 90

45

156
190
235

G 1/2

100

4 x 14

280
348

G 1/2

G 1/2

8 x 18

199
261
380

45

140

156
180
235

G 1/2

100

280
348

4 x 14

TM02 1570 2203

B1

F (DIN)
PN16/DN100

141

16
CRN pumps with magnetic drive (MAGdrive)
50 Hz
Technical data

CRN pumps with magnetic drive


Dimensions and weights
CRN 1s - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

D1

D2 D3 DIN flange Oval flange

CRN 1s-2

0.37

367

558

342

533

141 109

24

20

CRN 1s-3

0.37

367

558

342

533

141 109

25

20

CRN 1s-4

0.37

385

576

360

551

141 109

25

21

CRN 1s-5

0.37

403

594

378

569

141 109

25

21

CRN 1s-6

0.37

421

612

396

587

141 109

26

22

CRN 1s-7

0.37

439

630

414

605

141 109

26

22

CRN 1s-8

0.37

457

648

432

623

141 109

27

22

CRN 1s-9

0.37

475

666

450

641

141 109

27

23

CRN 1s-10

0.37

493

684

468

659

141 109

27

23

CRN 1s-11

0.55

511

702

486

677

141 109

29

24

CRN 1s-12

0.55

529

720

504

695

141 109

29

25

CRN 1s-13

0.55

547

738

522

713

141 109

30

25

CRN 1s-15

0.55

583

774

558

749

141 109

30

26

CRN 1s-17

0.55

619

810

594

785

141 109

31

27

CRN 1s-19

0.75

655

886

630

861

141 109

33

28

CRN 1s-21

0.75

697

928

672

903

141 109

35

30

CRN 1s-23

0.75

733

964

708

939

141 109

35

31

CRN 1s-25

1.1

769

1000

744

975

141 109

39

35

CRN 1s-27

1.1

805

1036

780

1011

141 109

39

35

CRN 1s-30

1.1

859

1090

834

1065

141 109

40

36

CRN 1s-33

1.1

913

1144

888

1119

141 109

41

37

CRN 1s-36

1.1

967

1198

942

1173

141 109

43

38

For information about electrical data, see pages 160 to 161.

142

Net weight [kg]

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


50 Hz

CRN 1 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2 D3 DIN flange Oval flange

CRN 1-2

0.37

367

558

342

533

141 109

24

20

CRN 1-3

0.37

367

558

342

533

141 109

25

20

CRN 1-4

0.37

385

576

360

551

141 109

25

21

CRN 1-5

0.37

403

594

378

569

141 109

25

21

CRN 1-6

0.37

421

612

396

587

141 109

26

22

CRN 1-7

0.55

439

630

414

605

141 109

26

22

CRN 1-8

0.55

457

648

432

623

141 109

27

22

CRN 1-9

0.55

475

666

450

641

141 109

27

23

CRN 1-10

0.55

493

684

468

659

141 109

27

23

CRN 1-11

0.75

511

702

486

677

141 109

29

24

CRN 1-12

0.75

535

720

504

695

141 109

29

25

CRN 1-13

0.75

553

738

522

713

141 109

30

25

CRN 1-15

0.75

589

774

558

749

141 109

30

26

CRN 1-17

1.1

625

810

594

785

141 109

31

27

CRN 1-19

1.1

661

886

630

861

141 109

33

28

CRN 1-21

1.1

697

928

672

903

141 109

35

30

CRN 1-23

1.1

733

964

708

939

141 109

35

31

CRN 1-25

1.5

785

1000

744

975

141 109

39

35

CRN 1-27

1.5

821

1036

780

1011

141 109

39

35

CRN 1-30

1.5

875

1090

834

1065

141 109

40

36

CRN 1-33

2.2

929

1144

888

1119

141 109

41

37

CRN 1-36

2.2

983

1198

942

1173

141 109

43

38

For information about electrical data, see pages 160 to 161.

143

16
CRN pumps with magnetic drive (MAGdrive)
50 Hz
Technical data

CRN 3 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

Net weight [kg]

D1

B1 B1+B2 B1 B1+B2

D2 D3 DIN flange Oval flange

CRN 3-2

0.37

367

558

342

533

141 109

24

20

CRN 3-3

0.37

367

558

342

533

141 109

25

20

CRN 3-4

0.37

385

576

360

551

141 109

25

21

CRN 3-5

0.55

403

594

378

569

141 109

26

22

CRN 3-6

0.55

421

612

396

587

141 109

27

22

CRN 3-7

0.55

439

630

414

605

141 109

27

23

CRN 3-8

0.75

463

694

438

669

141 109

30

25

CRN 3-9

0.75

481

712

456

687

141 109

30

26

CRN 3-10

0.75

499

730

474

705

141 109

30

26

CRN 3-11

1.1

517

748

492

723

141 109

33

29

CRN 3-12

1.1

535

766

510

741

141 109

33

29

CRN 3-13

1.1

553

784

528

759

141 109

34

30

CRN 3-15

1.1

589

820

564

795

141 109

35

30

CRN 3-17

1.5

641

922

616

897

178 110

43

39

CRN 3-19

1.5

677

958

652

933

178 110

44

39

CRN 3-21

2.2

713

1034

688

1009

178 110

45

41

CRN 3-23

2.2

749

1070

724

1045

178 110

46

42

CRN 3-25

2.2

785

1106

760

1081

178 110

47

42

CRN 3-27

2.2

821

1142

796

1117

178 110

47

43

CRN 3-29

2.2

857

1178

832

1153

178 110

48

44

CRN 3-31

897

1232

872

1207

198 120

53

49

CRN 3-33

933

1268

908

1243

198 120

54

50

CRN 3-36

987

1322

962

1297

198 120

55

51

For information about electrical data, see pages 160 to 161.

CRN 5 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D3 DIN flange Oval flange

CRN 5-2

0.37

367

558

342

533

141 109

26

21

CRN 5-3

0.55

394

585

369

560

141 109

27

23

CRN 5-4

0.75

421

652

396

627

141 109

28

24

CRN 5-5

0.75

454

685

429

660

141 109

30

26

CRN 5-6

1.1

481

712

456

687

141 109

33

29

CRN 5-7

1.1

508

739

483

714

141 109

33

29

CRN 5-8

1.1

535

766

510

741

141 109

34

30

CRN 5-9

1.5

578

859

553

834

178 110

41

37

CRN 5-10

1.5

605

886

580

861

178 110

42

37

CRN 5-11

2.2

632

953

607

928

178 110

43

39

CRN 5-12

2.2

659

980

634

955

178 110

43

39

CRN 5-13

2.2

686

1007

661

982

178 110

44

40

CRN 5-14

2.2

713

1034

688

1009

178 110

45

40

CRN 5-15

2.2

740

1061

715

1036

178 110

45

41

CRN 5-16

767

1102

742

1077

178 110

49

44

CRN 5-18

825

1160

800

1135

198 120

51

47

CRN 5-20

879

1214

854

1189

198 120

52

48

CRN 5-22

933

1305

908

1280

220 134

65

61

CRN 5-24

987

1359

962

1334

220 134

67

62

CRN 5-26

1041

1413

1016

1388

220 134

68

64

CRN 5-29

5.5

1122

1513

1097

1488

220 134 300

77

72

CRN 5-32

5.5

1254

1645

1229

1620

220 134 300

92

88

CRN 5-36

5.5

1362

1753

1337

1728

220 134 300

94

90

For information about electrical data, see pages 160 to 161.

144

D2

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


50 Hz

CRN 10 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3 DIN flange Oval flange

CRN 10-1

0.55

443

634

443

634

141 109

40

CRN 10-2

0.75

447

678

447

678

141 109

41

36
38

CRN 10-3

1.1

477

708

477

708

141 109

45

41

CRN 10-4

1.5

523

804

523

804

178 110

53

49

CRN 10-5

2.2

553

874

553

874

178 110

55

51

CRN 10-6

2.2

583

904

583

904

178 110

56

52

CRN 10-7

618

953

618

953

198 120

61

57

CRN 10-8

648

983

648

983

198 120

62

59

CRN 10-9

678

1050

678

1050

198 120

74

71

CRN 10-10

708

1080

708

1080

220 134

CRN 10-12

5.5

768

1159

768

1159

220 134 300

74

71

76

73

CRN 10-14

5.5

860

1251

860

1251

220 134 300

99

95

CRN 10-16

5.5

920

1311

920

1311

220 134 300

101

97

CRN 10-18

7.5

980

1359

980

1359

260 159 300

121

118

CRN 10-20

7.5

1040

1419

1040

1419

260 159 300

123

120

CRN 10-22

11

1100

1571

1100

1571

314 204 350

191

157

For information about electrical data, see pages 160 to 161.

CRN 15 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3 DIN flange Oval flange

CRN 15-1

1.1

490

721

490

721

141 109

45

40

CRN 15-2

2.2

505

826

505

826

178 110

53

48

CRN 15-3

555

890

555

890

198 120

59

54

CRN 15-4

600

972

600

972

220 134

71

67

CRN 15-5

5.5

645

1036

645

1036

220 134 300

73

68

CRN 15-6

5.5

722

1113

722

1113

220 134 300

95

90

CRN 15-7

7.5

767

1146

767

1146

260 159 300

111

107

CRN 15-8

7.5

812

1191

812

1191

260 159 300

115

110

CRN 15-9

7.5

857

1236

857

1236

260 159 300

117

112

CRN 15-10

11

979

1450

979

1450

314 204 350

141

136

CRN 15-12

11

1069

1540

1069

1540

314 204 350

143

139

CRN 15-14

15

1159

1630

1159

1630

314 204 350

165

161

CRN 15-17

15

1294

1765

1294

1765

314 204 350

184

180

For information about electrical data, see pages 160 to 161.

145

16
CRN pumps with magnetic drive (MAGdrive)
50 Hz
Technical data

CRN 20 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3 DIN flange Oval flange

CRN 20-1

1.1

487

718

487

718

141 109

46

41

CRN 20-2

2.2

503

824

503

824

178 110

54

49

CRN 20-3

553

925

553

925

220 134

71

66

CRN 20-4

5.5

630

1021

630

1021

220 134 300

93

88

CRN 20-5

5.5

675

1066

675

1066

220 134 300

94

89

CRN 20-6

7.5

720

1099

720

1099

260 159 300

113

108

CRN 20-7

7.5

765

1144

765

1144

260 159 300

114

110

CRN 20-8

11

887

1358

887

1358

314 204 350

137

132

CRN 20-10

11

977

1448

977

1448

314 204 350

141

136

CRN 20-12

15

1067

1538

1067

1538

314 204 350

176

171

CRN 20-14

15

1157

1628

1157

1628

314 204 350

179

175

CRN 20-17

18.5

1292

1807

1292

1807

314 204 350

206

202

For information about electrical data, see pages 160 to 161.

CRN 32 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type

Motor P2 [kW]

Dimension [mm]
DIN flange
B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3

DIN flange

Oval flange

CRN 32-1-1

1.5

505

786

178

110

270

69

CRN 32-1

2.2

505

826

178

110

270

69

CRN 32-2-2

575

910

198

120

270

76

CRN 32-2

575

947

220

134

270

87

CRN 32-3-2

5.5

666

1057

220

134

300

102

CRN 32-3

5.5

666

1057

220

134

300

102

CRN 32-4-2

7.5

715

1094

260

159

300

121

CRN 32-4

7.5

715

1094

260

159

300

121

CRN 32-5-2

11

895

1366

314

204

350

148

CRN 32-5

11

895

1366

314

204

350

148

CRN 32-6-2

11

965

1436

314

204

350

151

CRN 32-6

11

965

1436

314

204

350

151

CRN 32-7-2

15

1035

1506

314

204

350

193

CRN 32-7

15

1035

1506

314

204

350

193

CRN 32-8-2

15

1105

1576

314

204

350

199

CRN 32-8

15

1105

1576

314

204

350

199

CRN 32-9-2

18.5

1175

1690

314

204

350

199

CRN 32-9

18.5

1175

1690

314

204

350

199

CRN 32-10-2

18.5

1245

1760

314

204

350

202

CRN 32-10

18.5

1245

1760

314

204

350

202

CRN 32-11-2

22

1315

1856

314

204

350

276

CRN 32-11

22

1315

1856

314

204

350

176

CRN 32-12-2

22

1385

1926

314

204

350

280

CRN 32-12

22

1385

1926

314

204

350

280

For information about electrical data, see pages 160 to 161.


Note: CRN 32 pumps are also available with PJE connection.

146

Oval flange

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


50 Hz

CRN 45 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3

DIN flange

Oval flange
-

CRN 45-1-1

559

894

198

120

270

81

CRN 45-1

559

931

220

134

270

92

CRN 45-2-2

5.5

660

1051

220

134

300

107

CRN 45-2

7.5

639

1018

260

159

300

121

CRN 45-3-2

11

829

1300

314

204

350

153

CRN 45-3

11

829

1300

314

204

350

153

CRN 45-4-2

15

909

1380

314

204

350

185

CRN 45-4

15

909

1380

314

204

350

195

CRN 45-5-2

18.5

989

1504

314

204

350

195

CRN 45-5

18.5

989

1504

314

204

350

195

CRN 45-6-2

22

1069

1610

314

204

350

273

CRN 45-6

22

1069

1610

314

204

350

273

For information about electrical data, see pages 160 to 161.


Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange Oval flange
B1 B1+B2 B1 B1+B2

CRN 64-1-1

D1

Net weight [kg]


D2

D3 DIN flange Oval flange

561

933

220 134 270

95

CRN 64-1

7.5

561

940

260 159 300

118

CRN 64-2-2

11

644

1115

314 204 350

152

CRN 64-2-1

11

754

1225

314 204 350

152

CRN 64-2

15

754

1225

314 204 350

170

CRN 64-3-2

15

836

1307

314 204 350

193

CRN 64-3-1

18.5

836

1351

314 204 350

191

CRN 64-3

18.5

836

1351

314 204 350

191

CRN 64-4-2

22

919

1460

314 204 350

266

CRN 64-4-1

22

919

1460

314 204 350

266

For information about electrical data, see pages 160 to 161.


Note: CRN 64 pumps are also available with PJE connection.

CRN 90 - MAGdrive, 50 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange Oval flange
B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2

D3 DIN flange Oval flange

CRN 90-1-1

5.5

592

983

220 134 300

111

CRN 90-1

7.5

571

950

260 159 300

125

CRN 90-2-2

15

773

1244

314 204 350

177

CRN 90-2

18.5

773

1288

314 204 350

192

CRN 90-3-2

18.5

865

1380

314 204 350

197

For information about electrical data, see pages 160 to 161.


Note: CRN 90 pumps are also available with PJE connection.

147

16
CRN pumps with magnetic drive (MAGdrive)
60 Hz
Technical data

CRN 1s - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

Net weight [kg]

D1

D2 D3 DIN flange Oval flange

CRN1s-2

0.37

367

558

342

533

141 109

24

20

CRN1s-3

0.37

367

558

342

533

141 109

25

20

CRN1s-4

0.37

385

576

360

551

141 109

25

21

CRN1s-5

0.37

403

594

378

569

141 109

25

21

CRN1s-6

0.55

421

612

396

587

141 109

27

23

CRN1s-7

0.55

439

630

414

605

141 109

27

23

CRN1s-8

0.55

457

648

432

623

141 109

28

23

CRN1s-9

0.75

475

666

450

641

141 109

29

25

CRN1s-10

0.75

493

684

468

659

141 109

29

25

CRN1s-11

0.75

511

702

486

677

141 109

30

25

CRN1s-12

0.75

529

720

504

695

141 109

30

26

CRN1s-13

0.75

547

738

522

713

141 109

31

26

CRN1s-15

1.1

583

774

558

749

141 109

40

36

CRN1s-17

1.1

619

810

594

785

141 109

40

36

CRN1s-19

1.1

655

886

630

861

141 109

41

36

CRN1s-21

1.5

713

994

688

969

178 110

44

39

CRN1s-23

1.5

749

1030

724

1005

178 110

44

40

CRN1s-25

1.5

785

1066

760

1041

178 110

44

40

CRN1s-27

2.2

821

1142

796

1117

178 110

45

41

For information about electrical data, see pages 160 to 161.

CRN 1 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B1+B2

B1

B1+B2

Net weight [kg]


D1

D2

D3

DIN flange

Oval flange

CRN1-2

0.37

367

558

342

533

141

109

24

20

CRN1-3

0.37

367

558

342

533

141

109

25

20

CRN1-4

0.55

385

576

360

551

141

109

26

22

CRN1-5

0.55

403

594

378

569

141

109

26

22

CRN1-6

0.75

421

612

396

587

141

109

28

24

CRN1-7

0.75

439

630

414

605

141

109

28

24

CRN1-8

0.75

457

648

432

623

141

109

28

24

CRN1-9

1.1

475

666

450

641

141

109

37

33

CRN1-10

1.1

493

684

468

659

141

109

37

33

CRN1-11

1.1

511

742

486

717

141

109

37

33

CRN1-12

1.1

535

766

510

741

141

109

39

35

CRN1-13

1.5

569

850

544

825

178

110

41

36

CRN1-15

1.5

605

886

580

861

178

110

41

37

CRN1-17

1.5

641

922

616

897

178

110

42

38

CRN1-19

2.2

677

998

652

973

178

110

42

38

CRN1-21

2.2

713

1034

688

1009

178

110

43

39

CRN1-23

2.2

749

1070

724

1045

178

110

44

40

CRN1-25

790

1125

765

1100

198

120

54

50

CRN1-27

826

1161

801

1136

198

120

55

51

For information about electrical data, see pages 160 to 161.

148

Oval flange

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


60 Hz

CRN 3 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2 D3 DIN flange Oval flange

CRN3-2

0.37

367

558

342

533

141 109

24

20

CRN3-3

0.55

367

558

342

533

141 109

26

21

CRN3-4

0.75

385

576

360

551

141 109

27

23

CRN3-5

0.75

403

594

378

569

141 109

27

23

CRN3-6

1.1

421

612

396

587

141 109

36

31

CRN3-7

1.1

439

630

414

605

141 109

36

32

CRN3-8

1.1

463

694

438

669

141 109

38

33

CRN3-9

1.5

497

778

472

753

178 110

39

35

CRN3-10

1.5

515

796

490

771

178 110

39

35

CRN3-11

1.5

533

814

508

789

178 110

39

35

CRN3-12

2.2

551

872

526

847

178 110

39

35

CRN3-13

2.2

569

890

544

865

178 110

40

36

CRN3-15

2.2

605

926

580

901

178 110

41

36

CRN3-17

646

981

621

956

198 120

51

47

CRN3-19

682

1017

657

992

198 120

52

47

CRN3-21

718

1053

693

1028

198 120

52

48

CRN3-23

754

1126

729

1101

198 120

69

65

CRN3-25

790

1162

765

1137

198 120

70

65

For information about electrical data, see pages 160 to 161.

CRN 5 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2

D3 DIN flange Oval flange

CRN5-2

0.75

367

558

342

533

141 109

27

22

CRN5-3

1.1

394

585

369

560

141 109

35

31

CRN5-4

1.1

421

652

396

627

141 109

35

31

CRN5-5

1.5

470

751

445

726

178 110

39

35

CRN5-6

2.2

497

818

472

793

178 110

39

35

CRN5-7

2.2

524

845

499

820

178 110

39

35

CRN5-8

2.2

551

872

526

847

178 110

40

36

CRN5-9

583

918

558

893

198 120

49

45

CRN5-10

610

945

585

920

198 120

50

45

CRN5-11

637

972

612

947

198 120

50

46

CRN5-12

664

1036

639

1011

198 120

65

61

CRN5-13

691

1063

666

1038

198 120

66

62

CRN5-14

719 1089.6 694 1064.6 198 120

67

62

CRN5-15

745 1116.6 720 1091.6 198 120

67

62

CRN5-16

5.5

817 1208.4 792 1183.4 220 134 300

76

71

CRN5-18

5.5

875 1266.4 850 1241.4 220 134 300

76

72

CRN5-20

5.5

929 1320.4 904 1295.4 220 134 300

77

73

For information about electrical data, see pages 160 to 161.

149

16
CRN pumps with magnetic drive (MAGdrive)
60 Hz
Technical data

CRN 10 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

D1

B1 B1+B2 B1 B1+B2
634

443

D2

D3 DIN flange Oval flange

CRN10-1

0.75

443

141 109

41

37

CRN10-2

1.5

463 743.5 463 743.5 178 110

50

47

CRN10-3

2.2

493 813.5 493 813.5 178 110

51

47

CRN10-4

528

61

57

CRN10-5

558

930

558

930

198 120

78

74

CRN10-6

588

1026

588

1026

198 120

79

75

CRN10-7

5.5

635

1026

635

1026

220 134 300

86

82

CRN10-8

5.5

665

1056

665

1056

220 134 300

87

84

CRN10-9

7.5

695

1074

695

1074

260 159 300

97

94

CRN10-10

7.5

725

1104

725

1104

260 159 300

97

94

CRN10-12

7.5

785

1164

785

1164

260 159 300

97

94

CRN10-14

11

902

1373

902

1373

314 204 350

152

148

CRN10-16

11

962

1433

962

1433

314 204 350

154

150

863

634

Net weight [kg]

528

863

198 120

For information about electrical data, see pages 160 to 161.

CRN 15 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]

Net weight [kg]

DIN flange

Oval flange

B1

B1+B2

B1

B1+B2

786.5 178 110

D1

D2

D3 DIN flange Oval flange

CRN15-1

1.5

506

786.5

506

CRN15-2

510

845

510

845

198 120

46

56

41

CRN15-3

5.5

572

963

572

963

220 134 300

51

75

70

CRN15-4

7.5

617

996

617

996

260 159 300

87

83

CRN15-5

7.5

645

1024

645

1024

260 159 300

87

83

CRN15-6

11

764

1235

764

1235

314 204 350

148

143

CRN15-7

11

809

1280

809

1280

314 204 350

152

148

CRN15-8

15

854

1325

854

1325

314 204 350

173

168

CRN15-9

15

899

1370

899

1370

314 204 350

175

170

CRN15-10

15

979

1450

979

1450

314 204 350

175

170

CRN15-12

18.5

1069

1584

1069

1584

314 204 350

169

164

For information about electrical data, see pages 160 to 161.

CRN 20 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange

Oval flange

B1 B1+B2 B1 B1+B2

D1

D2

D3 DIN flange Oval flange

CRN20-1

2.2

503 823.5 503 823.5 178 110

52

47

CRN20-2

508

76

71

CRN20-3

7.5

CRN20-4

11

CRN20-5
CRN20-6

880

508

880

198 120

570

949

740

1211

570

949

260 159 300

87

82

740

1211

314 204 350

146

141

11

785

15

830

1256

785

1256

314 204 350

147

142

1301

830

1301

314 204 350

170

CRN20-7

15

165

875

1346

875

1346

314 204 350

171

CRN20-8

18.5

167

887

1402

887

1402

314 204 350

163

159

For information about electrical data, see pages 160 to 161.

150

Net weight [kg]

16
Technical data

CRN pumps with magnetic drive (MAGdrive)


60 Hz

CRN 32 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange
B1

CRN32-1-1

Oval flange

Net weight [kg]

D1

B1+B2 B1 B1+B2

D2

D3 DIN flange Oval flange

505

840

198 120

CRN32-1

5.5

505

896

220 134 300

77
96

CRN32-2-2

5.5

575

966

220 134 300

101

CRN 32-2-1

5.5

575

966

220 134 300

101

CRN32-2

7.5

575

954

260 159 300

108

CRN32-3-2

11

690

1161

314 204 350

155

CRN32-3

11

690

1161

314 204 350

155

CRN32-4-2

15

757

1228

314 204 350

179

CRN32-4

15

757

1228

314 204 350

179

CRN32-5-2

15

895

1366

314 204 350

180

CRN32-5

18.5

895

1410

314 204 350

172

CRN32-6-2

18.5

965

1480

314 204 350

172

CRN32-6

22

965

1506

314 204 350

238

CRN32-7-2

22

1035

1576

314 204 350

266

CRN32-7

22

1035

1576

314 204 350

266

For information about electrical data, see pages 160 to 161.


Note: CRN 32 pumps are also available with PJE connection.

CRN 45 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange Oval flange
B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2

D3 DIN flange Oval flange

CRN45-1-1

5.5

559

950

220 134 300

106

CRN45-1

7.5

559

938

260 159 300

116

CRN45-2-2

11

770

1241

314 204 350

160

CRN45-2-1

15

749

1220

314 204 350

178

CRN45-2

15

749

1220

314 204 350

178

CRN45-3-2

18.5

829

1344

314 204 350

169

CRN45-3-1

18.5

829

1344

314 204 350

169

CRN45-3

18.5

829

1344

314 204 350

169

22

909

1450

314 204 350

268

CRN45-4-2

For information about electrical data, see pages 160 to 161.


Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange Oval flange
B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2

D3 DIN flange Oval flange

CRN64-1-1

7.5

561

940

260 159 300

111

CRN64-1

11

671

1142

314 204 350

158

CRN64-2-2

15

644

1115

314 204 350

173

CRN64-2-1

18.5

754

1269

314 204 350

168

CRN64-2

22

754

1295

314 204 350

243

CRN64-3-2

22

836

1377

314 204 350

166

For information about electrical data, see pages 160 to 161.


Note: CRN 64 pumps are also available with PJE connection.

151

16
Technical data

CRN 90 - MAGdrive, 60 Hz
CRN MAGdrive
Pump type Motor P2 [kW]

Dimension [mm]
DIN flange Oval flange
B1 B1+B2 B1 B1+B2

D1

Net weight [kg]


D2

CRN90-1-1

11

702

1173

314 204 350

164

CRN90-1

15

681

1152

314 204 350

182

CRN90-2-2

22

773

1314

314 204 350

250

For information about electrical data, see pages 160 to 161.


Note: CRN 90 pumps are also available with PJE connection.

152

D3 DIN flange Oval flange

17
Technical data

CRH(N) pumps
50 Hz

17. Technical data


CRH(N) pumps
Dimensional drawings

TM05 1523 3211

CRH(N)
1s - 90

SmCRH(N)
Inlet [mm]
Outlet [mm]
Ref.
A
B
AA
D
E
F
Note

40
25
102
76
165
134
299

MeCRH(N)

CRH(N)32

50
50

CRH(N)45

50
80
50
80
Dim. [mm]
102
102
102
124
124
124
According to specifications for CR horizontal pumps (page 59)
191
191
229
210
210
210
401
401
439

CRH(N)64-90
100
100
102
124
280
210
490

Ref. AA is only applicable with motors 5.5 - 45 kW.

153

17
CRH(N) pumps
50 Hz
Technical data

CRH(N) pumps
Dimensions and weights
CRH(N) 1s, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

Net weight [kg]

D2 D3 D4 D5 E3 E4

DIN

DIN

CR flange CRN flange

CRH(N)1s-2

0.37

309 191

500

109 71 63

24

CRH(N)1s-3

0.37

309 191

500

109 71 63

24

21
22

CRH(N)1s-4

0.37

327 191

518

109 71 63

25

22

CRH(N)1s-5

0.37

345 191

536

109 71 63

25

22

CRH(N)1s-6

0.37

363 191

554

109 71 63

26

23

CRH(N)1s-7

0.37

381 191

572

109 71 63

26

23

CRH(N)1s-8

0.37

399 191

590

109 71 63

26

23

CRH(N)1s-9

0.37

417 191

608

109 71 63

27

24

CRH(N)1s-10

0.37

435 191

626

109 71 63

27

24

CRH(N)1s-11

0.37

453 191

644

109 71 63

27

25

CRH(N)1s-12

0.37

471 191

662

109 71 63

28

25

CRH(N)1s-13

0.37

489 191

680

109 71 63

28

25

CRH(N)1s-15

0.55

525 191

716

109 71 63

30

27

CRH(N)1s-17

0.55

561 191

752

109 71 63

31

28

CRH(N)1s-19

0.55

597 191

788

109 71 63

31

28

CRH(N)1s-21

0.75

655 231

886

109 80 54

34

32

CRH(N)1s-23

0.75

691 231

922

109 80 54

35

32

CRH(N)1s-25

0.75

727 231

958

109 80 54

35

33

CRH(N)1s-27

1.1

763 231

994

109 80 54

38

36

CRH(N)1s-30

1.1

817 231

1048

109 80 54

40

37

CRH(N)1s-33

1.1

871 231

1102

109 80 54

41

38

CRH(N)1s-36

1.1

925 231

1156

109 80 54

42

40

For information about electrical data, see pages 160 to 161.

CRH(N) 1, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2 D3 D4 D5 E3 E4

DIN

CR flange CRN flange

CRH(N)1-2

0.37

309 191

500

109 71 63

24

CRH(N)1-3

0.37

309 191

500

109 71 63

24

22

CRH(N)1-4

0.37

327 191

518

109 71 63

25

22

CRH(N)1-5

0.37

345 191

536

109 71 63

25

22

CRH(N)1-6

0.37

363 191

554

109 71 63

26

23

CRH(N)1-7

0.37

381 191

572

109 71 63

26

23

CRH(N)1-8

0.55

399 191

590

109 71 63

27

24

CRH(N)1-9

0.55

417 191

608

109 71 63

27

25

CRH(N)1-10

0.55

435 191

626

109 71 63

28

25

CRH(N)1-11

0.55

453 191

644

109 71 63

28

25

CRH(N)1-12

0.75

477 231

708

109 80 54

30

28

CRH(N)1-13

0.75

495 231

726

109 80 54

31

28

CRH(N)1-15

0.75

531 231

762

109 80 54

32

29

CRH(N)1-17

1.1

567 231

798

109 80 54

35

32

CRH(N)1-19

1.1

603 231

834

109 80 54

36

33

CRH(N)1-21

1.1

639 231

870

109 80 54

36

34

CRH(N)1-23

1.1

675 231

906

109 80 54

37

35

CRH(N)1-25

1.5

727 321

1048

110 90 44

45

42

CRH(N)1-27

1.5

763 321

1084

110 90 44

46

43

CRH(N)1-30

1.5

817 321

1138

110 90 44

47

44

CRH(N)1-33

2.2

871 321

1192

110 90 44

49

46

CRH(N)1-36

2.2

925 321

1246

110 90 44

50

47

For information about electrical data, see pages 160 to 161.

154

Net weight [kg]


DIN

21

17
Technical data

CRH(N) pumps
50 Hz

CRH(N) 3, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

Net weight [kg]

D3 D4 D5 E3 E4

DIN

DIN

CR flange CRN flange

CRH(N)3-2

0.37

309 191

500

109 71 63

24

CRH(N)3-3

0.37

309 191

500

109 71 63

24

21
22

CRH(N)3-4

0.37

327 191

518

109 71 63

25

22

CRH(N)3-5

0.37

345 191

536

109 71 63

25

22

CRH(N)3-6

0.55

363 191

554

109 71 63

26

23

CRH(N)3-7

0.55

381 191

572

109 71 63

27

24

CRH(N)3-8

0.75

405 231

636

109 80 54

29

26

CRH(N)3-9

0.75

423 231

654

109 80 54

29

27

CRH(N)3-10

0.75

441 231

672

109 80 54

30

27

CRH(N)3-11

1.1

459 231

690

109 80 54

32

30

CRH(N)3-12

1.1

477 231

708

109 80 54

33

30

CRH(N)3-13

1.1

495 231

726

109 80 54

33

31

CRH(N)3-15

1.1

531 231

762

109 80 54

34

32

CRH(N)3-17

1.5

583 321

904

110 90 44

42

39

CRH(N)3-19

1.5

619 321

940

110 90 44

43

40

CRH(N)3-21

2.2

655 321

976

110 90 44

44

41

CRH(N)3-23

2.2

691 321

1012

110 90 44

45

42

CRH(N)3-25

2.2

727 321

1048

110 90 44

46

42

CRH(N)3-27

2.2

763 321

1084

110 90 44

46

43

CRH(N)3-29

2.2

799 321

1120

110 90 44

47

44

CRH(N)3-31

840 335

1175

120 100 34

54

51

CRH(N)3-33

876 335

1211

120 100 34

55

52

CRH(N)3-36

930 335

1265

120 100 34

56

53

For information about electrical data, see pages 160 to 161.

CRH(N) 5, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

Net weight [kg]

D3 D4 D5

E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)5-2

0.37

309 191

500

109 71 63

24

21

CRH(N)5-3

0.55

336 191

527

109 71 63

26

23

CRH(N)5-4

0.55

363 191

554

109 71 63

26

23

CRH(N)5-5

0.75

396 231

627

109 80 54

28

26

CRH(N)5-6

1.1

423 231

654

109 80 54

31

29

CRH(N)5-7

1.1

450 231

681

109 80 54

32

29

CRH(N)5-8

1.1

477 231

708

109 80 54

32

30

CRH(N)5-9

1.5

520 321

841

110 90 44

40

37

CRH(N)5-10

1.5

547 321

868

110 90 44

40

38

CRH(N)5-11

2.2

574 321

895

110 90 44

42

39

CRH(N)5-12

2.2

601 321

922

110 90 44

42

39

CRH(N)5-13

2.2

628 321

949

110 90 44

43

40

CRH(N)5-14

2.2

655 321

976

110 90 44

43

40

CRH(N)5-15

2.2

682 321

1003

110 90 44

44

41

CRH(N)5-16

2.2

709 321

1030

110 90 44

45

41

CRH(N)5-18

768 335

1103

120 100 34

52

49

CRH(N)5-20

822 335

1157

120 100 34

53

50

CRH(N)5-22

876 372

1248

134 112 22

63

60

CRH(N)5-24

930 372

1302

134 112 22

64

62

CRH(N)5-26

984 372

1356

134 112 22

66

63

CRH(N)5-29

1065 372

1437

134 112 22

67

64

CRH(N)5-32

5.5

1175 391

1566

134 132 2

1294 1434

83

80

CRH(N)5-36

5.5

1283 391

1674

134 132 2

1402 1542

86

82

For information about electrical data, see pages 160 to 161.

155

17
CRH(N) pumps
50 Hz
Technical data

CRH(N) 10, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

D3

Net weight [kg]

D4 D5

E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)10-1

0.37

414 191

605

109 71 139

58

52

CRH(N)10-2

0.75

430 231

661

109 80 130

60

54

CRH(N)10-3

1.1

464 231

695

109 80 130

63

58

CRH(N)10-4

1.5

494 321

815

109 90 120

71

66

CRH(N)10-5

2.2

524 321

845

110 90 120

73

68

CRH(N)10-6

2.2

584 321

905

110 90 120

74

69

CRH(N)10-7

614 335

949

120 100 110

81

76

CRH(N)10-8

644 335

979

120 100 110

82

77

CRH(N)10-9

674 335

1009

120 100 110

83

78

CRH(N)10-10

816 372

1188

134 112 98

93

88

CRH(N)10-12

876 372

1248

134 112 98

95

90

CRH(N)10-14

5.5

936 391

1327

134 132 78

118

113

CRH(N)10-16

5.5

996 391

1387

134 132 78

1115 1255

120

115

CRH(N)10-18

7.5

1056 379

1435

159 132 78

1125 1303

133

128

CRH(N)10-20

7.5

1116 379

1495

159 132 78

1185 1363

136

130

CRH(N)10-22

7.5

1176 379

1555

159 132 78

1245 1423

138

132

1055 1195

For information about electrical data, see pages 160 to 161.

CRH(N) 15, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

D3

D5

E3

E4

DIN

CR flange CRN flange

CRH(N)15-1

1.1

442 231

673

109 80 130

62

CRH(N)15-2

2.2

458 231

689

110 90 120

70

65

CRH(N)15-3

508 335

843

120 100 110

77

73

CRH(N)15-4

553 372

925

134 112 98

88

83

CRH(N)15-5

598 372

970

134 112 98

89

85

CRH(N)15-6

5.5

672 391

1063

134 132 78 140 791 931

111

107

CRH(N)15-7

5.5

717 391

1108

134 132 78 140 836

113

108

CRH(N)15-8

7.5

762 379

1141

159 132 78 178 831

125

121

CRH(N)15-9

7.5

807 379

1186

159 132 78 178 876

127

122

CRH(N)15-10

11

965 471

1436

204 160 50 210 1103

169

165

CRH(N)15-12

11

1055 471

1526

204 160 50 210 1193

173

168

CRH(N)15-14

11

1145 471

1616

204 160 50 210 1283

177

171

CRH(N)15-17

11

1280 471

1751

204 160 50 210 1418

195

189

For information about electrical data, see pages 160 to 161.

156

D4

Net weight [kg]


DIN

57

17
Technical data

CRH(N) pumps
50 Hz

CRH(N) 20, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

D3

D4

Net weight [kg]


D5

E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)20-1

1.1

509 231

740

109 80 130

62

CRH(N)20-2

2.2

525 321

846

110 90 120

70

57
65

CRH(N)20-3

575 372

947

134 112 98

86

82

CRH(N)20-4

5.5

649 391

1040

134 132 78

768

908

108

104

CRH(N)20-5

5.5

694 391

1085

134 132 78

813

953

110

105

CRH(N)20-6

7.5

739 379

1118

159 132 78

808

986

122

117

CRH(N)20-7

7.5

784 379

1163

159 132 78

853 1031

123

119

CRH(N)20-8

11

942 471

1413

204 160 50

1080 1290

166

161

CRH(N)20-10

11

1032 471

1503

204 160 50 210 1170 1380

169

165

CRH(N)20-12

15

1122 471

1593

204 160 50 210 1260 1470

186

181

CRH(N)20-14

15

1212 471

1683

204 160 50 210 1350 1560

190

184

CRH(N)20-17

18.5

1347 545

1892

204 180 30

208

202

1485 1739

For information about electrical data, see pages 160 to 161.

CRH(N) 32, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

D3

D4

Net weight [kg]


D5

E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)32-1-1

1.5

533 321

854

110 90 120

81

CRH(N)32-1

2.2

533 321

854

110 90 120

82

77
77

CRH(N)32-2-2

603 335

938

120 100 110

90

86

CRH(N)32-2

603 372

975

134 112 98

CRH(N)32-3-2

5.5

673 391

1064

134 132 78

99

95

792

932

114

109

CRH(N)32-3

5.5

673 391

1064

134 132 78

792

932

114

109

CRH(N)32-4-2

7.5

743 391

1134

159 132 78

812

990

129

124

CRH(N)32-4

7.5

743 391

1134

159 132 78

812

990

129

124

CRH(N)32-5-2

11

923 471

1394

204 160 50

1061 1271

176

171

CRH(N)32-5

11

923 471

1394

204 160 50 210 1061 1271

176

171

CRH(N)32-6-2

11

993 471

1464

204 160 50 210 1131 1341

179

174

CRH(N)32-6

11

993 471

1464

204 160 50 210 1131 1341

179

174

CRH(N)32-7-2

15

1063 471

1534

204 160 50 210 1201 1411

195

190

CRH(N)32-7

15

1063 471

1534

204 160 50 210 1201 1411

195

190

CRH(N)32-8-2

15

1133 471

1604

204 160 50 210 1271 1481

201

196
196

CRH(N)32-8

15

1133 471

1604

204 160 50 210 1271 1481

201

CRH(N)32-9-2

18.5

1203 515

1718

204 160 50 254 1341 1595

217

213

CRH(N)32-9

18.5

1203 515

1718

204 160 50 254 1341 1595

217

213

CRH(N)32-10-2

18.5

1273 515

1788

204 160 50 254 1411 1665

220

216

CRH(N)32-10

18.5

1273 515

1788

204 160 50 254 1411 1665

220

216

CRH(N)32-11-2

22

1343 541

1884

204 180 30 241 1494 1735

238

233

CRH(N)32-11

22

1343 541

1884

204 180 30 241 1494 1735

238

233

CRH(N)32-12-2

22

1413 541

1954

204 180 30 241 1564 1805

241

237

CRH(N)32-12

22

1413 541

1954

204 180 30 241 1564 1805

241

237

CRH(N)32-13-2

30

1483 610

2093

300 200 10 305 1675 1980

347

342

CRH(N)32-13

30

1483 610

2093

300 200 10 305 1675 1980

347

342

CRH(N)32-14-2

30

1553 610

2163

300 200 10 305 1745 2050

350

345

CRH(N)32-14

30

1553 610

2163

300 200 10 305 1745 2050

350

345

For information about electrical data, see pages 160 to 161.

157

17
CRH(N) pumps
50 Hz
Technical data

CRH(N) 45, 50 Hz
CR
Pump type

Dimension [mm]

Motor P2 [kW]

DIN flange
B1

B2 B1+B2

D2

D3

Net weight [kg]

D4 D5

E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)45-1-1

549

884

120

154

99

101

CRH(N)45-1

549

921

134

142

108

110

CRH(N)45-2-2

5.5

629

1020

134

122

748

888

123

125

CRH(N)45-2

7.5

629

1008

159

122

698

876

135

137

CRH(N)45-3-2

11

819

1290

204

94

957 1167

182

184

CRH(N)45-3

11

819

1290

204

94

957 1167

182

184

CRH(N)45-4-2

15

899

1370

204

94

1037 1247

199

201
201

CRH(N)45-4

15

899

1370

204

94

1037 1247

199

CRH(N)45-5-2

18.5

979

1494

204

94

1117 1371

216

218

CRH(N)45-5

18.5

979

1494

204

94

1117 1371

216

218

CRH(N)45-6-2

22

1059

1600

204 180 74

1210 1451

236

238

CRH(N)45-6

22

1059

1600

204 180 74

1210 1451

236

238

CRH(N)45-7-2

30

1139

1749

300 200 54

1331 1636

343

345

CRH(N)45-7

30

1139

1749

300 200 54

1331 1636

343

345

CRH(N)45-8-2

30

1219

1829

300 200 54

1411 1716

347

349

CRH(N)45-8

30

1219

1829

300 200 54

1411 1716

347

349

CRH(N)45-9-2

30

1299

1909

300 200 54

1491 1796

351

353

CRH(N)45-9

37

1299

1966

300 200 54

1489 1794

381

383

CRH(N)45-10-2

37

1379

2046

300 200 54

1569 1874

386

387
387

CRH(N)45-10

37

1379

2046

300 200 54

1569 1874

386

CRH(N)45-11-2

45

1465

2174

325 225 29

1673 1959

474

476

CRH(N)45-11

45

1459

2168

325 225 29

1667 1953

474

476

CRH(N)45-12-2

45

1539

2248

325 225 29

1747 2033

479

480

CRH(N)45-12

45

1539

2248

325 225 29

1747 2033

479

480

CRH(N)45-13-2

45

1619

2328

325 225 29

1827 2113

483

485

For information about electrical data, see pages 160 to 161.

CRH(N) 64, 50 Hz
CR
Pump type

Motor P2 [kW]

Dimension [mm]
DIN flange
B1

B2 B1+B2

D2

D3

D4 D5
-

E3

E4

DIN

CR flange CRN flange

CRH(N)64-1-1

580

952

134 112 142

121

114

CRH(N)64-1

5.5

580

971

134 132 122

699

839

133

125

CRH(N)64-2-2

7.5

662

1041

159 132 122

731

909

149

142

CRH(N)64-2-1

11

772

1243

204 160 94

910 1120

193

186

CRH(N)64-2

11

772

1243

204

94

910 1120

193

186

CRH(N)64-3-2

15

854

1325

204

94

992 1202

210

203

CRH(N)64-3-1

15

854

1325

204

94

992 1202

210

203

CRH(N)64-3

18.5

854

1369

204

94

992 1246

223

216

CRH(N)64-4-2

18.5

936

1451

204

94

1074 1328

228

221

CRH(N)64-4-1

22

936

1477

204 180 74

1087 1328

242

234

CRH(N)64-4

22

936

1477

204 180 74

1087 1328

242

234

CRH(N)64-5-2

30

1018

1628

204 200 54

1210 1515

348

341

CRH(N)64-5-1

30

1018

1628

300 200 54

1210 1515

348

341

CRH(N)64-5

30

1018

1628

300 200 54

1210 1515

348

341

CRH(N)64-6-2

30

1100

1710

300 200 54

1292 1597

354

348

CRH(N)64-6-1

37

1100

1767

300 200 54

1292 1597

384

378

CRH(N)64-6

37

1100

1767

300 200 54

1292 1597

384

378

CRH(N)64-7-2

37

1182

1849

300 200 54

1374 1679

389

382

CRH(N)64-7-1

37

1182

1849

300 200 54

1374 1679

389

382

CRH(N)64-7

45

1188

1897

325 225 29

1378 1664

473

467

CRH(N)64-8-2

45

1270

1979

325 225 29

1478 1764

478

471

CRH(N)64-8-1

45

1270

1979

325 225 29

1478 1764

478

471

For information about electrical data, see pages 160 to 161.

158

Net weight [kg]


DIN

17
Technical data

CRH(N) pumps
50 Hz

CRH(N) 90, 50 Hz
CR
Pump type

Motor P2 [kW]

Dimension [mm]
DIN flange
B1

B2 B1+B2

D2

D3

D4 D5

Net weight [kg]


E3

E4

DIN

DIN

CR flange CRN flange

CRH(N)90-1-1

5.5

590

981

134

122

709

849

133

127

CRH(N)90-1

7.5

590

969

159

122

659

969

145

139

CRH(N)90-2-2

11

792

1263

204

94

930 1263

193

187

CRH(N)90-2

15

792

1263

204

94

930 1263

206

200

CRH(N)90-3-2

18.5

884

1399

204

94

1022 1399

224

218

CRH(N)90-3

22

884

1425

204

74

1035 1425

238

232

CRH(N)90-4-2

30

976

1586

300 200 54

1168 1586

345

339

CRH(N)90-4

30

976

1586

300 200 54

1168 1586

345

339

CRH(N)90-5-2

37

1068

1735

300 200 54

1258 1735

382

376

CRH(N)90-5

37

1068

1735

300 200 54

1258 1735

382

376

CRH(N)90-6-2

45

1166

1875

325 225 29

1374 1875

471

466

CRH(N)90-6

45

1166

1875

325 225 29

1374 1875

471

466

For information about electrical data, see pages 160 to 161.

159

18

CR, CRI, CRN, CRT,

Motor data

18. Motor data


Standard 2-pole motors for CR, CRI, CRN, 50 Hz
Motor
P2
[kW]

Frame
size

0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5

71
71
80
80
90
90
100
112
132
132
160
160
160

22

30
37
45
55
75

[%]

Istart

Speed
[min-1]

220-240/380-415Y
1.7/1.0
0.80-0.70
78.5
220-240/380-415Y
2.5/1.4
0.80-0.70
80.0
220-240/380-415Y
3.3/1.9
0.81-0.71
81.0
220-240/380-415Y
4.5/2.6
0.84-0.76
82.8
220-240/380-415Y
5.5/3.2
0.87-0.82
85.5
380-415
4.5-4.5
0.89-0.87
87.5
380-415
6.3-6.3
0.87-0.82
87.5
380-415
8.0-8.0
0.88-0.84
89.0
380-415
11.2-11.2
0.88-0.84
90.0
380-415/660-690Y 14.8-13.6/8.5-8.1 0.89-0.88 89.5-90.5
380-415/660-690Y 21.2-19.6/12.2-11.6 0.90-0.88 90.0-88.0
380-415/660-690Y 28.5-26.0/16.2-15.6 0.91-0.90 91.0-92.3
380-415/660-690Y 35.0-32.0/20.0-19.2 0.91-0.90 91.6-92.6

8.5-9.2/4.9-5.3
12-13/6.9-7.5
19.1-20.5/11.0-11.8
28.5-31.5/16.3-17.9
46.3-50.7/26.8-29.3
37.8-42.3
52.9-58.0
89.6-98.4
120-131
115-124/66.3-73.7
140-153/80.5-90.5
188-203/107-122
249-272/142-163

2850-2880
2830-2850
2840-2870
2820-2860
2890-2910
2890-2910
2900-2920
2910-2930
2910-2930
2920-2930
2920-2940
2920-2940
2920-2940

180

380-415/660-690Y 41.5-38.5/23.8-22.8 0.91-0.89 91.9-92.8

311-343/179-203

2930-2940

200
200
225
250
280

380-415/660-690Y
380-415/660-690Y
380-415/660-690Y
380-415/660-690Y
380-415/660-690Y

371/214
461/266
562/325
632/367
896-832/518-481

2960
2960
2965
2975
2975

I 1/1
[A]

Standard voltage
[V]

Cos 1/1

TM03 1711 2805

MG

0.88-0.88
0.89-0.89
0.89-0.89
0.90-0.90
0.89-0.89

93.5
94.0
95.0
95.5
95.0

TM03 1710 2805

Siemens
53.0/30.5
64.0/37.0
77.0/44.5
93.0/54.0
128/74.0

Standard 4-pole motors for CR, CRI, CRN, 50 Hz


Motor P2
[kW]

Frame
size

Standard voltage
[V]

I 1/1
[A]

Cos 1/1

[%]

Speed
[min-1]

0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0

71
71
80
80
90
90
100
100
112
132
132
160

220-240/380-415Y
220-240/380-415Y
220-240/380-415Y
220-240/380-415Y
220-240/380-415Y
220-240/380-415Y
220-240/380-415Y
380-415
380-415
380-415/660-690Y
380-415/660-690Y
380-415/660-690Y

1.48/0.85
1.90/1.10
2.60/1.50
3.30/1.90
5.00/2.90
6.40/3.70
9.20/5.30
7.40
8.90
11.2-10.4/6.50-6.25
15.2-14.0/8.70-8.40
21.6-20.4/12.4-12.0

0.75-0.65
0.77-0.67
0.79-0.70
0.79-0.70
0.78-0.71
0.80-0.74
0.79-0.76
0.79-0.69
0.82-0.76
0.86-0.84
0.87-0.85
0.88-0.84

71-72
71
77
78
78
80
83.5
85
86.5-87
89.0-90.0
89.5-90.5
91.0-92.0

1400-1420
1400-1420
1390-1410
1390-1410
1440-1445
1440-1450
1440-1450
1440-1450
1450-1455
1440-1450
1440-1450
1460-1470

15.0

160

380-415/660-690Y

29.0-28.0/16.8-16.4

0.87-0.84

92.6-92.0

1460-1470

160

TM03 1711 2805

MG

18

CR, CRI, CRN, CRT,

Motor P2 Frame
[kW]
size

Standard voltage
[V]

I 1/1
[A]

Cos 1/1

[%]

Istart

Speed
[min-1]

Motor data

Standard 2-pole motors for CR, CRI, CRN, 60 Hz

71
71
80
80
90
90
100
112
132
132
160
160
160

220-255/380-440Y
1.5-1.4/0.9-0.8
0.85-0.76 79.0-80.0
220-255/380-440Y
2.2-2.1/1.3-1.2
0.85-0.76 81.5-83.0
220-255/380-440Y
2.9-2.7/1.7-1.6
0.86-0.78 83.0-85.0
220-255/380-440Y
4.2-3.9/2.5-2.2
0.88-0.82 82.0-84.5
220-277/380-480Y
5.4-4.7/3.1-2.7
0.90-0.81 84.0-85.0
380-480
4.5-3.7
0.91-0.85 84.0-87.0
380-480
6.2-5.7
0.89-0.84 84.0-87.5
380-480
7.8-6.8
0.90-0.82 88.0-89.5
380-480
10.8-9.5
0.90-0.82 89.0-89.0
380-480/660-690Y 14.4-12.0/8.3-8.1 0.91-0.85 90.0-91.5
380-480/660-690Y 21.2-17.2/12.2-11.6 0.91-0.87 90.0-92.5
380-480/660-690Y 29.0-22.8/16.6-15.8 0.92-0.89 90.0-92.5
380-480/660-690Y 35.0-28.0/20.2-19.2 0.92-0.89 90.5-93.0

8.3-9.4/4.8-4.9
10.8-12.3/6.3-7.2
17.1-20.0/9.9-11.5
25.6-30.4/14.9-17.5
41.7-49.4/24.2-28.4
34.7-40.7
49.6-62.2
79.6-102
108-138
97.9-126/56.4-85.1
123-153/70.8-103
168-203/96.3-141
214-272/123-186

3410-3470
3390-3460
3400-3470
3390-3460
3470-3530
3470-3530
3430-3530
3510-3540
3510-3540
3480-3510
3500-3550
3500-3550
3500-3550

22

180

380-480/660-690Y 42.0-33.5/24.2-22.8 0.92-0.89 90.0-92.5

273-348/157-237

3500-3550

30

200

380-480/660-690Y 55.0-45.0/31.5-30.0 0.90-0.86 92.5-93.5

358-360/252-240

3540-3565

37

200

380-480/660-690Y 67.0-54.0/38.5-37.0 0.90-0.87 93.0-94.0

442-448/254-307

3540-3565

45

225

380-480/660-690Y 81.0-65.0/46.5-44.0 0.90-0.87 94.5-95.0

543-559/312-378

3545-3570

55

250

380-480 /660-690Y 97.0-79.0/56.0-53.0 0.91-0.88 94.5-95.0

621-632/358-424

3565-3580

75

280

380-480 /660-690Y 134-108/77.0-73.0 0.90-0.87 95.0-95.5

871-864/501-584

3565-3580

TM03 1711 2805

MG
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5

TM03 1710 2805

Siemens

Standard 4-pole motors for CR, CRI, CRN, 60 Hz


Motor P2
[kW]

Frame
size

Standard voltage
[V]

I 1/1
[A]

Cos 1/1

[%]

Speed
[min-1]

0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0

71
71
80
80
90
90
100
100
112
132
132
160

220-255/380-440Y
220-255/380-440Y
220-255/380-440Y
220-255/380-440Y
220-277/380-480Y
220-277/380-480Y
220-277/380-480Y
380-480
380-480
380-480/660-690Y
380-480/660-690Y
380-480/660-690Y

1.21/0.70
1.72/0.99
2.40/1.40
3.10/1.80
4.75-4.50/2.75-2.60
6.30-5.70/3.65-3.30
9.00-7.80/5.20-4.50
7.10-6.75
8.60-7.70
10.8-9.30/6.25-6.10
14.4-12.4/8.30-8.20
21.0-17.8/12.0-11.8

0.80-0.69
0.82-0.72
0.83-0.75
0.84-0.76
0.82-0.67
0.83-0.73
0.80-0.70
0.80-0.70
0.85-0.73
0.89-0.81
0.90-0.82
0.90-0.83

69-69
73-74
77-80
77-81
78-80
79-81
83-85
84-85
87-89
89.5-91.0
90.5-92.0
91.4-93.0

1680-1720
1680-1720
1660-1710
1660-1710
1720-1750
1720-1750
1720-1750
1720-1750
1740-1755
1750-1770
1750-1770
1750-1770

15.0

160

380-480/660-690Y

29.0-24.2/16.6-16.4

0.89-0.83

91.7-93.2

1750-1770

TM03 1711 2805

MG

161

19

CR, CRI, CRN, CRT,

Pumped liquids

19. Pumped liquids


Thin, non-explosive liquids, not containing solid
particles or fibres. The liquid must not chemically attack
the pump materials.
When pumping liquids with a density and/or viscosity
higher than that of water, use oversized motors, if
required.
Whether a pump is suitable for a particular liquid
depends on a number of factors of which the most
important are the chloride content, pH value,
temperature and content of chemicals, oils, etc.
Please note that aggressive liquids, such as sea water
and some acids, may attack or dissolve the protective
oxide film of the stainless steel and thus cause corrosion.
CR(E), CRI(E)
CR(E), CRI(E) pumps are suitable for non-corrosive
liquids.
Use CR(E), CRI(E) pumps for liquid transfer, circulation
and pressure boosting of cold or hot clean water.
CRN(E)
CRN(E) pumps are suitable for industrial liquids.
Use CRN(E) pumps in systems where all parts in
contact with the liquid must be made of high-grade
stainless steel.
CRT(E)
For saline or chloride-containing liquids such as sea
water or for oxidising agents such as hypochlorites,
Grundfos offers CRT(E) pumps made of titanium.
See the separate data booklet on CRT(E) available on
www.Grundfos.com (WebCAPS).

162

19

CR, CRI, CRN, CRT,

List of pumped liquids


A number of typical liquids are listed below.
Other pump versions may be applicable, but those
stated in the list are considered to be the best choices.
The table is intended as a general guide only and
cannot replace actual testing of the pumped liquids and
pump materials under specific working conditions.
However, use the list with some caution. Factors such
as those mentioned below may affect the chemical
resistance of a specific pump version:
concentration of the pumped liquid

Often with additives.

The density and/or viscosity differ from that/those of water.


Take this factor into account when calculating motor output and
pump performance.

Pump selection depends on many factors. Contact Grundfos.

Risk of crystallisation/precipitation in shaft seal.

Highly inflammable liquid.

Combustible liquid.

Insoluble in water.

Low self-ignition point.

Pumped liquids

Notes

liquid temperature
pressure.
Take safety precautions when pumping dangerous
liquids.

Pumped liquid

Chemical formula

Note

Liquid concentration,
liquid temperature

CR(E),
CRI(E)

CRN(E)

Acetic acid

CH3COOH

5 %, +20 C

HQQE

Acetone

CH3COCH3

1, F

100 %, +20 C

HQQE

D, F

HQQE

20 %, +30 C

HQQE

Alkaline degreasing agent


Ammonium bicarbonate
Ammonium hydroxide

NH4HCO 3
NH4OH

20 %, +40 C

HQQE

1, 3, 4, F

100 %, +20 C

HQBV

0.5 %, +20 C

HQQV

< +120 C

HQQE

+120 C to +180 C

< +90 C

HQQE

Ca(CH3COO)2

D, E

30 %, +50 C

HQQE

Ca (OH)2

Saturated solution, +50 C

HQQE

< +30 C, max. 500 ppm

HQQE

Aviation fuel
Benzoic acid

C6H5COOH

Boiler water
Calcareous water
Calcium acetate (as coolant with inhibitor)
Calcium hydroxide
Chloride-containing water
Chromic acid
Citric acid

H2CrO4

1 %, +20 C

HQQV

HOC(CH2CO2H)2COOH

5 %, +40 C

HQQE

+120 C

HQQE

+120 C

HQQE

Completely desalinated water (demineralised


water)
Condensate
Copper sulphate

CuSO4

10 %, +50 C

HQQE

D, E, 3

100 %, +80 C

HQQV

2, 3, 4, F

100 %, +20 C

HQBV

< +120 C

HQQE

C2H5OH

1, F

100 %, +20 C

HQQE

HOCH2CH2OH

D, E

50 %, +50 C

HQQE

HCOOH

5 %, +20 C

HQQE

Corn oil
Diesel oil
Domestic hot water (potable water)
Ethanol (ethyl alcohol)
Ethylene glycol
Formic acid

OHCH2CH(OH)CH2OH

D, E

50 %, +50 C

HQQE

Hydraulic oil (mineral)

E, 2, 3

100 %, +100 C

HQQV

Hydraulic oil (synthetic)

E, 2, 3

100 %, +100 C

HQQV

CH3CHOHCH3

1, F

100 %, +20 C

HQQE

CH3CH(OH)COOH

E, H

10 %, +20 C

HQQV

C17H31COOH

E, 3

100 %, +20 C

HQQV

Glycerine (glycerol)

Isopropyl alcohol
Lactic acid
Linoleic acid
Methanol (methyl alcohol)

CH3OH

Motor oil

1, F

100 %, +20 C

HQQE

E, 2, 3

100 %, +80 C

HQQV

Naphthalene

C10H8

E, H

100 %, +80 C

HQQV

Nitric acid

HNO3

1 %, +20 C

HQQE

Oil-containing water
Olive oil

< +100 C

HQQV

D, E, 3

100 %, +80 C

HQQV

163

19

CR, CRI, CRN, CRT,

Pumped liquids

Pumped liquid
Oxalic acid
Ozone-containing water

Chemical formula

Note

Liquid concentration,
liquid temperature

CR(E),
CRI(E)

CRN(E)

(COOH)2

1 %, +20 C

HQQE

(O3)

< +100 C

HQQE

D, E, 3

100 %, +80 C

HQQV

1, 3, 4, F

100 %, +20 C

HQBV

H3PO4

20 %, +20 C

HQQE

C3H7OH

1, F

100 %, +20 C

HQQE

CH3CH(OH)CH2OH

D, E

50 %, +90 C

HQQE

K2CO3

20 %, +50 C

HQQE

KOOCH

D, E

30 %, +50 C

HQQE

KOH

20 %, +50 C

HQQE

KMnO4

5 %, +20 C

HQQE

D, E, 3

100 %, +80 C

HQQV

0.1 %, +20 C

HQQE

Peanut oil
Petrol
Phosphoric acid
Propanol
Propylene glycol
Potassium carbonate
Potassium formate (as coolant with inhibitor)
Potassium hydroxide
Potassium permanganate
Rape seed oil
Salicylic acid

C6H4(OH)COOH

Silicone oil

E, 3

100 %

HQQV

NaHCO3

10 %, +60 C

HQQE

Sodium chloride (as coolant)

NaCl

D, E

30 %, < +5 C, pH > 8

HQQE

Sodium hydroxide

NaOH

20 %, +50 C

HQQE

Sodium bicarbonate

Sodium hypochlorite

NaOCl

0.1 %, +20 C

HQQV

Sodium nitrate

NaNO3

10 %, +60 C

HQQE

Sodium phosphate

Na3PO4

E, H

10 %, +60 C

HQQE

Sodium sulphate

Na2SO4

E, H

10 %, +60 C

HQQE

< +120 C

HQQE

D, E, 3

100 %, +80 C

HQQV

1 %, +20 C

HQQV

Softened water
Soya oil
Sulphuric acid

H2SO4

Sulphurous acid

H2SO3

Unsalted swimming-pool water

164

1 %, +20 C

HQQE

Approx. 2 ppm free chlorine (Cl2)

HQQE

20

CR, CRI, CRN, CRT,

Further product documentation

20. Further product documentation


WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than
20 languages.
In WebCAPS, all information is divided into 6 sections:
Catalogue
Literature
Service
Sizing
Replacement
CAD drawings.

Catalogue
This section is based on fields of application and pump types,
and contains
technical data
curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
product photos
dimensional drawings
wiring diagrams
quotation texts, etc.

Literature
In this section you can access all the latest documents of a given
pump, such as
data booklets
installation and operating instructions
service documentation, such as Service kit catalogue and
Service kit instructions
quick guides
product brochures, etc.

Service
This section contains an easy-to-use interactive service
catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, this section contains service videos showing you
how to replace service parts.

165

20

CR, CRI, CRN, CRT,

Further product documentation

Sizing

This section is based on different fields of application and


installation examples, and gives easy step-by-step instructions in
how to
select the most suitable and efficient pump for your installation
carry out advanced calculations based on energy
consumption, payback periods, load profiles, life cycle costs,
etc.
analyse your selected pump via the built-in life cycle cost tool
determine the flow velocity in wastewater applications, etc.

Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare
Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.

CAD drawings
In this section it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
.dxf, wireframe drawings
.dwg, wireframe drawings.
3-dimensional drawings:
.dwg, wireframe drawings (without surfaces)
.stp, solid drawings (with surfaces)
.eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 185,000 Grundfos products
in more than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.

Fig. 94 WinCAPS CD-ROM

166

167

Being responsible is our foundation


Thinking ahead makes it possible
Innovation is the essence

96486346 1011
Repl. 96486346 0509

GB

ECM: 1082794

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark


Telephone: +45 87 50 14 00
www.grundfos.com

The name Grundfos, the Grundfos logo, and the payoff BeThinkInnovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

You might also like