Appendix A APEX3000 Remote Lab Guide v1.0 ARRIS
Appendix A APEX3000 Remote Lab Guide v1.0 ARRIS
(APEX3000)
Remote Lab Guide
Table of Contents
Exercise #1 Download APEX-EM & Navigate the APEX3000 Element Manager
Menus
Introduction
Task 1: Ping the APEXs IP Address from the SDM Desktop
Task 2: Download the APEX-EM to the SDM Desktop
Task 3: Take a Tour of the APEX3000 Element Manager Menus
3
3
3
3
5
6
6
7
7
8
Exercise #4: APEX Output Transport Stream (OTS) Configuration and Program
Mapping
9
9
12
12
12
13
14
15
15
16
16
16
16
17
Page 1
18
18
19
19
19
19
19
20
20
20
20
21
21
Page 2
Page 3
______________________________________________________________________
______________________________________________________________________
4. On the System Status screen, allow the mouse to hover over RF Port 6-1. Click
once. What tabs did that operation take you to? List them here:
______________________________________________________________________
5. Select the Chassis tab and then the Host/Enet tab. List which Host module is
currently Active.
______________________________________________________________________
6. Locate the screen where you can set-up the IP address of GigE1. What tabs did you
select to get to that screen?
______________________________________________________________________
7. Select the Blades tab and then the QAM Config tab. List which blades are QAM
modules and which are Fan modules.
______________________________________________________________________
8. What tabs do you select to see the Operating Mode of an Output Transport Stream
(OTS)?
______________________________________________________________________
9. What button do you click to save a change to a setting you made?
______________________________________________________________________
10. Which of the 4 main tabs do you select to configure the ECMG?
______________________________________________________________________
Page 4
Page 5
Page 6
Page 7
Interleaver Depth
i128-j4
i128-j1
i128-j2
i128-j1
Page 8
Page 9
2. Configure five Program Mappings for QAM2-1-1 using the Bulk Add and the
following parameters:
Blades tab > Select RF Port 1 on Blade 2 > Prog Mapping tab >
Display mappings for QAM 2 - 1 1 SECOND ROW > Bulk Add
Number to add:
5
Mapping Enable:
Checked
Input IF:
GigE5
Input UDP Port:
5000
Multicast IP:
239.0.1.5
Source IP:
10.100.100.12
Input Program:
3
Output Program:
3
Pre-Encrypt:
Not checked
Follow DTCP:
Not checked
+ (Input UDP Port:)
0
+ (Multicast IP:)
0.0.0.0
+ (Source IP:)
0.0.0.0
+ (Input Program:)
1
+ (Output Program:)
1
3. Configure the Source and Provider IDs for the five Program Mappings you just
configured for QAM2-1-1 using the Bulk Add.
Blades tab > Select RF Port 1 on Blade 2 > Prog Mapping tab >
Display mappings for QAM 2 - 1 1 ROWS TWO through SIX
Output Program:
3 (Sprout)
Source ID:
13229
Provider ID:
3
Output Program:
4 (VH1 Soul)
Source ID:
16991
Provider ID:
3
Output Program:
5 (MTV Hits)
Source ID:
10959
Provider ID:
3
Output Program:
6 (Chiller)
Source ID:
15580
Provider ID:
3
Output Program:
7 (Centric)
Source ID:
12002
Provider ID:
3
Page 10
4. Configure three more Program Mappings for QAM2-1-1 using the following
parameters:
Blades tab > Select RF Port 1 on Blade 2 > Prog Mapping tab >
Display mappings for QAM 2 - 1 1 SEVENTH ROW
Mapping Enable:
Checked
Input IF:
GigE5
Input UDP Port:
5000
Multicast IP:
239.0.1.5
Source IP:
10.100.100.12
Input Program:
10
Output Program:
10
Pre-Encrypt:
Not checked
Follow DTCP:
Not checked
Source ID:
4104
Provider ID:
3
Blades tab > Select RF Port 1 on Blade 2 > Prog Mapping tab >
Display mappings for QAM 2 - 1 1 EIGTH ROW
Mapping Enable:
Checked
Input IF:
GigE5
Input UDP Port:
5000
Multicast IP:
239.0.1.5
Source IP:
10.100.100.12
Input Program:
11
Output Program:
11
Pre-Encrypt:
Not checked
Follow DTCP:
Not checked
Source ID:
4129
Provider ID:
3
Blades tab > Select RF Port 1 on Blade 2 > Prog Mapping tab >
Display mappings for QAM 2 - 1 1 NINTH ROW
Mapping Enable:
Checked
Input IF:
GigE5
Input UDP Port:
5005
Multicast IP:
0.0.0.0
Source IP:
10.100.100.12
Input Program:
12
Output Program:
12
Pre-Encrypt:
Not checked
Follow DTCP:
Not checked
Source ID:
4358
Provider ID:
3
APEX3000 Remote Lab Guide, Rev 1.0
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Interleaver Depth
i128-j4
i128-j1
i128-j2
i128-j1
Page 17
Page 18
Page 19
Sling Remote turn on the set-top if not on and enter channel 101. Channel up
through channels 101 to 108. Enter channel 301 and 302.
2. Select a switched channel. Using the APEX3000 Element Manager confirm the
mapping is successful. Select Blades tab > Select RF Port 1 on Blade 1 > Prog
Status tab. There should be a program mapping. It should have a Program Status
of Successful Program Remultiplexed.
3. Select Blades tab > Blade 1 (QAM) > RTSP Status tab. On Index 001 there should
be the current SDV session listed.
4. Select Chassis tab > SDV tab. The RTSP Session Count: should be 1. The
Controller Discovery: should be Discovered and the Controller Connection:
should be Connected.
Page 20
2. Select System Status tab then Alarms tab. Record the current Alarm(s).
______________________________________________________________________
______________________________________________________________________
3. Where did you go next to determine what the problem was and how did you fix it?
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Page 21