Manual LVL200
Manual LVL200
SITRANS LVL200S
Contents
Contents
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
..
..
..
..
..
..
..
5
5
5
5
6
6
6
6
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
..
..
..
7
7
8
9
General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting instructions . . . . . . . . . . . . . . . . . . . . . . . .
10
14
Structure . . . . . . . . . .
Principle of operation .
Operation. . . . . . . . . .
Storage and transport
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
16
16
17
In general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustment elements . . . . . . . . . . . . . . . . . . . . . . . .
Functional chart . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
19
20
..
..
..
..
22
22
23
24
Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
25
Maintenance . . . . . . . . . . .
Rectify faults . . . . . . . . . . .
Exchange of the electronics
Instrument repair . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
33
33836-EN-100908
Supplement
9.1
9.2
.
.
.
.
.
.
.
.
Dismounting
8.1
8.2
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Set up
6.1
6.2
6.3
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Mounting
4.1
4.2
.
.
.
.
.
.
.
.
Authorised personnel . . . . . . . .
Appropriate use . . . . . . . . . . . .
Warning about misuse . . . . . . .
General safety instructions . . . .
Safety label on the instrument . .
CE conformity . . . . . . . . . . . . .
SIL conformity . . . . . . . . . . . . .
Safety instructions for Ex areas .
Product description
3.1
3.2
3.3
3.4
4
4
4
Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbolism used. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
Supplementary documentation
Information:
Supplementary documents appropriate to the ordered version come
with the delivery. You can nd them listed in chapter "Product
description".
33836-EN-100908
List
The dot set in front indicates a list with no implied sequence.
Action
This arrow indicates a single action.
Sequence
Numbers set in front indicate successive steps in a procedure.
33836-EN-100908
33836-EN-100908
2.6 CE conformity
This device fullls the legal requirements of the applicable EC
guidelines. By attaching the CE mark, we provide conrmation of
successful testing.
33836-EN-100908
3 Product description
3 Product description
3.1 Structure
Scope of delivery
Constituent parts
Housing cover
Housing with electronics
Process tting with tuning fork
Type label
The type label contains the most important data for identication and
use of the instrument:
l
l
l
l
33836-EN-100908
Housing cover
Housing with electronics
Process tting
Article number
Serial number
Technical data
Article numbers, documentation
SITRANS LVL200S is a point level sensor with tuning fork for level
detection.
3 Product description
It is designed for industrial use in all areas of process technology and
can be used in liquids.
Typical applications are overll and dry run protection. With a tuning
fork of only 40 mm length, SITRANS LVL200S can be also mounted e.
g. in pipelines from DN 32. The small tuning fork allows use in vessels,
tanks and pipes. Thanks to its simple and robust measuring system,
SITRANS LVL200S is virtually unaected by the chemical and
physical properties of the liquid.
It functions even under dicult conditions such as turbulence, air
bubbles, foam generation, buildup, strong external vibration or
changing products.
Fault monitoring
The electronics module of SITRANS LVL200S continuously monitors
via frequency evaluation the following criteria:
l
l
l
Voltage supply
3.3 Operation
With the factory setting, products with a density > 0.07 g/cm
(0.025 lbs/in) can be measured. The instrument can be adapted if
products with lower density should be measured.
On the electronics module you will nd the following indicating and
adjustment elements:
33836-EN-100908
l
l
l
3 Product description
Transport
Transport inspection
Storage
l
l
l
l
l
Storage and transport temperature see chapter "Supplement Technical data - Ambient conditions"
Relative humidity 20 85 %
33836-EN-100908
4 Mounting
4 Mounting
4.1 General instructions
Suitability for the process conditions
Make sure that all parts of the instrument exposed to the process, in
particular the sensor element, process seal and process tting, are
suitable for the existing process conditions. These include above all
the process pressure, process temperature as well as the chemical
properties of the medium.
You can nd the specications in chapter "Technical data" or on the
type label.
Switching point
33836-EN-100908
10
4 Mounting
2
1
4
3
Switching point
Switching point
Switching point
Switching point
33836-EN-100908
11
4 Mounting
2
1
Switching point
Marking with screwed version on top, with ange versions directed to the
ange holes
With ange versions, the fork is directed as follows to the ange holes.
Moisture
33836-EN-100908
12
4 Mounting
Transport
Caution:
Do not hold SITRANS LVL200S on the tuning fork. Particularly with
ange or tube versions, the tuning fork can be damaged just by the
weight of the instrument. Transport coated instruments very carefully
and avoid touching the tuning fork.
Remove the packaging or the protective cover just before installation.
Pressure/Vacuum
Handling
33836-EN-100908
13
4 Mounting
Adhesive products
Marking
33836-EN-100908
14
4 Mounting
Flows
33836-EN-100908
Inowing medium
15
Take note of
safety instructions for Ex applications
Voltage supply
Connection cable
16
33836-EN-100908
Proceed as follows:
Insert the cable into the sensor through the cable entry
Insert the wire ends into the open terminals according to the wiring
plan
Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
0,5 g / cm3
0,7 g / cm3
20-72V DC
20-253V AC
1
2
3
1 2
3 4 5
6 7 8
33836-EN-100908
Control lamp
DIL switch for mode adjustment
DIL switch for switching point adaptation
Ground terminal
Connection terminals
17
+ L1 N
1
1
2
3
Fig. 9: Wiring plan, single chamber housing
1
2
3
Relay output
Relay output
Voltage supply
33836-EN-100908
18
6 Set up
6 Set up
6.1 In general
The gures in brackets refer to the following illustrations.
Function/Conguration
In the basic setting, products with a density > 0.7 g/cm (0.025 lbs/in)
can be detected. For products with lower density, you have to set the
switch to > 0.5 g/cm (0.018 lbs/in).
On the electronics module you will nd the following indicating and
adjustment elements:
l
l
l
Note:
For test purposes, immerse the tuning fork of SITRANS LVL200S
always in liquids. Do not test the function of SITRANS LVL200S with
the hand. This can damage the sensor.
1
2
3
33836-EN-100908
1
2
3
19
6 Set up
Mode adjustment (2)
With the mode adjustment (A/B) you can change the switching
condition of the relay. You can set the required mode according to the
"Function chart" (A - max. detection or overow protection, B - min.
detection or dry run protection).
Sensitivity adjustment
(3)
With this DIL switch (3) you can set the switching point to liquids
having a density between 0.5 and 0.7 g/cm (0.018 and 0.025 lbs/in).
With the basic setting, liquids with a density of > 0.7 g/cm (0.025 lbs/
in) can be detected. In liquids with lower density, you must set the
switch to > 0.5 g/cm (0.018 lbs/in). The specications for the position
of the switching point relate to water - density value 1 g/cm (0.036 lbs/
in). In products with a dierent density, the switching point will shift in
the direction of the housing or tuning fork end depending on the
density and type of installation.
Note:
Keep in mind that foams with a density > 0.45 g/cm (0.016 lbs/in) are
detected by the sensor. This can cause faulty switchings particulary
when used as dry run protection system.
Switching status
3
4
5
(6) (7) (8)
Relay energized
Mode A
Overow protection
Green
3
4
5
(6) (7) (8)
Red
33836-EN-100908
Relay deenergized
20
Red
3
4
5
(6) (7) (8)
Relay energized
Mode B
Dry run protection
Green
3
4
5
(6) (7) (8)
Relay deenergized
Mode B
Dry run protection
Control lamp
6 Set up
Level
Failure of the supply
voltage
(mode A/B)
any
Failure
any
Switching status
Control lamp
3
4
5
(6) (7) (8)
Relay deenergized
3
4
5
(6) (7) (8)
ashes red
33836-EN-100908
Relay deenergized
21
Failure reasons
Fault rectication
Sensor
Process
Voltage supply
Signal processing
Cause
Removal
SITRANS LVL200S
Electronics defective
SITRANS LVL200S
signals "uncovered"
when the vibrating element is submerged (dry
run protection)
22
33836-EN-100908
Error
Cause
Removal
Interference on the
electronics module
instrument defective
33836-EN-100908
In general, all electronics modules of series SW60 can be interchanged. If you want to use an electronics module with a dierent
signal output, you carry out the complete setup. You nd the
necessary, suitable operating instruction on our homepage.
Note:
Keep in mind that enamelled instrument versions need special
electronics modules. These electronics modules are called SW60E or
SW60E1.
23
33836-EN-100908
24
8 Dismounting
8 Dismounting
8.1 Dismounting steps
Warning:
Before dismounting, be aware of dangerous process conditions such
as e.g. pressure in the vessel, high temperatures, corrosive or toxic
products etc.
Take note of chapters "Mounting" and "Connecting to power supply"
and carry out the listed steps in reverse order.
With Ex instruments, the housing cover may only be opened if there is
no explosive atmosphere present.
8.2 Disposal
The instrument consists of materials which can be recycled by
specialised recycling companies. We use recyclable materials and
have designed the electronics to be easily separable.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE directive 2002/96/EG and
the respective national laws. Pass the instrument directly on to a
specialised recycling company and do not use the municipal collecting
points. These may be used only for privately used products according
to the WEEE directive.
Correct disposal avoids negative eects to persons and environment
and ensures recycling of useful raw materials.
Materials: see chapter "Technical data"
33836-EN-100908
25
9 Supplement
9 Supplement
9.1 Technical data
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
- Process tting - thread
-
Process seal
Klingersil C-4400
Tuning fork
Sensor length
- Length SITRANS LVL200S
Materials, non-wetted parts
- Aluminium die-casting housing
316L
Ground terminal
316L
316L
316L/glass
Process ttings
- Pipe thread, cylindrical (DIN 3852-A)
G A, G1 A
NPT or 1 NPT
Flanges
hygienic ttings
Thread G1 A, 1 NPT
33836-EN-100908
9 Supplement
Pressure resistance
PN 64
Output variable
Output
Turn-on voltage
- Min.
-
Max.
Switching current
- Min.
-
Max.
Breaking capacity
- Min.
-
Max.
10 A
3 A AC, 1 A DC
50 mW
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.
Modes (adjustable)
- A
Relative humidity
45 75 %
Air pressure
Product temperature
Product density
Product viscosity
1 mPa s
Superimposed pressure
0 kPa
Sensor installation
Measuring accuracy
1 mm (0.04 in)
33836-EN-100908
Deviation
27
9 Supplement
10 (
25/64")
8 ( 5/16")
6 ( 15/64")
4 ( 5/32")
2 ( 5/64")
-2 (-5/64")
-4 (-5/32")
-6 (-15/64")
-8 (-5/16")
-10 (-25/64")
50C
(122 F)
0C
(32 F)
100C
(212 F)
150C
(302 F)
200C
(392 F)
250C
(482 F)
10 ( 25/64")
8 ( 5/16")
6 ( 15/64")
4 ( 5/32")
2 ( 5/64")
0
-2 (-5/64")
-4 (-5/32")
-6 (-15/64")
-8 (-5/16")
-10 (-25/64")
0,6
(0,022)
0,8
(0,029)
1
(0,036)
1,2
(0,043)
1,4
(0,051)
1,6
(0,058)
1,8
(0,065)
2
(0,072)
2,2
(0,079)
2,4
(0,087)
28
33836-EN-100908
1
2
3
4
5
6
9 Supplement
Inuence of the process pressure to the switching point
1
4
10 ( 25/64")
8 ( 5/16")
6 ( 15/64")
4 ( 5/32")
2 ( 5/64")
0
-2 (-5/64")
-4 (-5/32")
-6 (-15/64")
-8 (-5/16")
-10 (-25/64")
12
(174,1)
25
(362,6)
38
(551,1)
51
(739,7)
64
(928,2)
Repeatability
Hysteresis
Switching delay
Frequency
approx. 1200 Hz
Ambient conditions
Ambient temperature on the housing
33836-EN-100908
Process conditions
Measured variable
Process pressure
29
9 Supplement
2
3
70 C
(158 F)
40 C
(104 F)
0 C
(32 F)
-50 C
(-58 F)
1
50 C
(122 F)
100 C
(212 F)
150 C
(302 F)
200 C
(392 F)
250 C
(482 F)
-40 C
(-40 F)
1
64
(928)
40
(580)
20
(290)
-1 (-14,5)
-50 C
(-58 F)
0C
(32 F)
50C
(122 F)
100C
(212 F)
150C
(302 F)
200C
(392 F)
250C
(482 F)
Fig. 28: Process temperature - Process pressure with switch position 0.7 g/cm (mode switch)
1
2
1
64
(928)
40
(580)
20
(290)
30
0C
(32 F)
50C
(122 F)
100C
(212 F)
150C
(302 F)
200C
(392 F)
250C
(482 F)
33836-EN-100908
-1 (-14,5)
-50 C
(-58 F)
9 Supplement
Fig. 29: Process temperature - Process pressure with switch position 0.5 g/cm (mode switch)
1
2
Viscosity - dynamic
Density
Electromechanical data
Cable entry/plug (dependent on the version)
- Single chamber housing
or:
l
or:
l
Screw terminals
Adjustment elements
Mode switch
- A
-
0.7
Voltage supply
Operating voltage
Power consumption
33836-EN-100908
IP 66/IP 67
Overvoltage category
III
Protection class
Approvals
Depending on the version, instruments with approvals can have dierent technical data. For these
instruments, please note the corresponding approval documents. They are included in the scope
of delivery.
31
9 Supplement
33836-EN-100908
32
9 Supplement
9.2 Dimensions
SITRANS LVL200S
80 mm
(3 5/32")
125 mm (4 59/64")
84 mm (3 5/16")
112 mm (4 13/32")
~ 59 mm
(2 21/64")
~ 116 mm (4 9/16")
M20x1,5/
NPT
M20x1,5
M20x1,5/
NPT
33836-EN-100908
1
2
33
9 Supplement
55 mm
(2.17")
57 mm
(2.24")
36 mm
(1.42")
53 mm
(2.09")
32 (GA, "NPT)
41 (G1A, 1"NPT)
GA, "NPT
G1A, 1"NPT
6
3
49 mm
(1.93")
50 mm
(1.97")
33,7 mm
(1.33")
53 mm
(2.09")
53 mm
(2.09")
50 mm
(1.97")
19 mm
(0.75")
G=66 mm (2.6")
G1=69 mm (2.72")
18,5 mm
(0.73")
SITRANS LVL200S
Thread
Tri-Clamp
Cone DN 25
Bolting DN 40
Flange
Gas-tight leadthrough
Temperature adapter
33836-EN-100908
34
9 Supplement
178 mm (7.01")
34 mm
(1.34")
33836-EN-100908
1
2
35
*7ML19985KR01*
Rev. 1.1
33836-EN-100908