The document reports the results of dimensional checks of 20 checkpoints on a bearing stage before and after plating. The checkpoints were measured using a CMM machine and the results show that after plating the maximum measurement was 0.031mm, minimum was 0.021mm, and average was 0.027mm, compared to before plating where maximum was 0.026mm, minimum was 0.015mm, and average was 0.020mm.

Uploaded by

wanpudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views

Sampling Check (Doraemon)

The document reports the results of dimensional checks of 20 checkpoints on a bearing stage before and after plating. The checkpoints were measured using a CMM machine and the results show that after plating the maximum measurement was 0.031mm, minimum was 0.021mm, and average was 0.027mm, compared to before plating where maximum was 0.026mm, minimum was 0.015mm, and average was 0.020mm.

Uploaded by

wanpudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAMPLING CHECK - BEARING STAGE DOREAMON

Tools: CMM MACHINE Date: 28.09.15

BEFORE PLATING AFTER PLATING


Checkpoint 15 Checkpoint 15
No. No.
< 0.02 mm < 0.02 mm
1 0.022 1 0.029
2 0.021 2 0.030
3 0.015 3 0.022
4 0.018 4 0.031
5 0.023 5 0.021
6 0.025 6 0.029
7 0.015 7 0.024
8 0.026 8 0.029
9 0.020 9 0.028
10 0.016 10 0.030
11 0.019 11 0.025
12 0.021 12 0.022
13 0.023 13 0.028
14 0.024 14 0.030
15 0.022 15 0.021
16 0.024 16 0.031
17 0.019 17 0.029
18 0.018 18 0.021
19 0.016 19 0.031
20 0.020 20 0.027
MAX 0.026 MAX 0.031
MIN 0.015 MIN 0.021
AVG 0.020 AVG 0.027