Individual Solutions

for Demanding Sectors

DYNAVERT Drives
Loher stands for
quality and reliability

Loher, with its headquarters in Ruhstorf close to Passau, Germany, is one of the few suppliers

that can offer the complete range of electric drive technology. Loher can look back on 100 years of

tradition in the design and construction of electric motors for more than 40 years, state-of-the-art

control technology has been developed based on this extensive experience.

The specialist for many sectors In addition to customized drive systems,


we also offer a whole raft of drive
Loher offers complete system solutions inverter solutions. These are based on a
from the power supply up to the motor standard range of accessory kits, which
shaft from engineering in the quotation have enabled us to establish ourselves in
phase up to commissioning on-site. the widest range of sectors.
All of this from a single source.
Transformer, drive and motor, Additional accessories allow the drive
specifically adapted to the particular systems to be adapted to difficult line
application, with an excellent price- supply conditions, extremely long
performance ratio. motor cables and various control and
communication concepts even in
hazardous zones.

2
Loher drive inverters and motors
Intelligent drive systems from a single source

We are more than willing to clearly Loher quality something that you can
document both function and quality always depend on:
for you! We are certified to DIN ISO 9001 and we
are regularly subject to stringent quality
We offer complete drive systems, com- audits from independent institutions.
prising transformers, drive inverters and
motor from a single source! As system
supplier, we provide the complete drive Complete drive from a single
package. Our customers clearly see this source and therefore also clear
as the most important advantage. responsibility for the complete
drive
To prove the function of our drive Customer acceptance tests in
systems, we have our own test field the factory in compliance with
equipped with state-of-the-art equipment all of the relevant standards and
that is available for customer acceptance regulations
tests. In addition to visual and function Certified according to
checks and tests, in the presence of cus- DIN ISO 9001
tomers, we can also document the power Our test stands are equipped to
rating, the efficiency of the complete handle drives up to 6,000 kVA incl.
drive as well as the line supply behavior. load and measuring equipments

3
Four decades providing
the highest reliability and availability

Loher DYNAVERT drive inverters have already been in service for over four decades.

For applications where topmost priority is given to the highest degree of reliability and

availability of the drives.

DYNAVERT was specifically designed All of the drive requirements are taken
for the following sectors right from the into consideration from the word go
very start from the coupling, through the motor,
cables, drive inverter, line supply sit-
Chemical industry uation and connection to the supervisory
Oil and gas industries control system.
Power stations and utilities
Plastic industry Our many years of experience and
Basic materials industry competence as a motor manufacturer
Test stands have been efficiently incorporated in the
Conveyor technology design and adaptation of DYNAVERT, as
and applications in general machinery motors and drive inverters are developed,
construction. closely harmonized with one another.

DYNAVERT can be flexibly integrated into


any automation concept whether using
conventional control technology or bus
systems.
DYNAVERT T can be connected to
any of the normally encountered line
supply voltages and can feed both
synchronous and asynchronous motors.

Advantages

Cabinet units and cabinet systems in IP21 or higher degrees of protection


All of the drive units have their own connection space
Compact dimensions
Equipped with radio interference suppression
Low harmonics fed back into the line supply, optionally according IEEE519
Long motor cables can be used as a result of the integrated dv/dt filter for DYNAVERT T and as an inherent system
feature for DYNAVERT I
Wide supply voltage range
A main contactor is not required*
Drive units with 500 V and 690 V rated line supply voltage can be connected to non-grounded line supplies
(IT line supplies)
ATEX-certified motors for hazardous zones*

*only for DYNAVERT T

4
Loher DYNAVERT
compact and cabinet units
Power ranges, DYNAVERT T

690 V
DYNAVERT T
500 V
compact units
400 V

690 V
DYNAVERT T
cabinet systems/ 500 V
cabinet units
400 V

kW
2.2
3
4
5.5
7.5
11
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
550
630
710
800
900
1000
1200
...
6600
Power ranges, DYNAVERT I

950 V

690 V
DYNAVERT I
cabinet units 500 V

400 V

kW
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
550
630
710
800
900
1000
1200
1600
1800
2000
...
...
...
5600
Other power ranges / voltages 6000
on request

5
Loher DYNAVERT
Compact and complete from 2.2 kW to 6,600 kW

Supplementary equipment The filters allow overvoltage limit Insulation monitoring


values to be maintained for the The 500 V and 690 V drive units
Radio interference suppression. motor insulation as well as air and have insulation monitoring for non-
The line filter according to DIN EN creepage distances with- out re- grounded line supplies. This insula-
61800-3, category C2 (compact quiring any additional measures. tion monitoring reliably protects
devices) and C3 (cabinet devices) the drive inverter, cabling and the
respectively allows the use in Shutdown concept (option) motor when insulation faults occur.
industrial and public (only C2) line The ATEX-certified shutdown The 400 V drive units are equipped
supplies. For higher demands are concept of the DYNAVERT T drive with a ground fault monitoring
filters of category C1 available. inverter permits the drive system to with the same functionality for
be shut down with-out requiring a grounded line supplies.
Harmonics fed back into the line main contactor.
supply The integrated line reactor This also applies when operating
reduces the line-side harmonics. motors in hazardous Zone 1. This
For higher demands are Line Har- provides extensive cost-saving
monics Filter or Active Front End potential on the plant side.
optionally available.
Dual processor technology
Long motor cables The dual processor technology
The dv/dt output filter for means that there is sufficient com-
DYNAVERT T permits long motor putational performance to optimal-
cables to be used. Due to the inher- ly harmonize the pulse pattern. This
ent system characteris-tics for reduces the motor noise and lowers
DYNAVERT I almost unlimited mo- drive inverter and motor losses.
tor cable lengths can be used. This
provides a high degree of flexibility
when designing plants and equip-
ment especially for drives located
in hazardous Zones 1 and 2.

6
Loher DYNAVERT
Highly versatile through distributed intelligence in the drive inverter

The control electronics that have A field-orientated controller is also


been completely new-designed use availiable for DYNAVERT T to address
dual processor technology and cover applications that demand a high
a wide range of applications. dynamic performance.
With the appropriate menu setting,
DYNAVERT T can control both asyn-
chronous as well as synchronous
motors.

Terminal strip in compliance with 2 freely parameterizable analog Peripheral board 1...4
NAMUR Recommendation NE37, outputs (0 10 V, 0 20 mA, HTL encoder
with 4 20 mA) with automatic change- RS485 for an external operator
4 freely parameterizable digital over between current and voltage panel
relay outputs output RS232 for PC
parameterizable group fault SIN-COS tachometer
contact A field-orientated controller is also Technology board
12 freely parameterizable digital available for DYNAVERT T to ad- Relay
inputs, 2 of which can be used dress applications that demand a Protective separation according to
either as PTC thermistor inputs high dynamic performance. VDE 0106/EN50178
or pulse inputs Optocoupler
2 freely parameterizable analog Protective separation according to
inputs (0 10 V, 0 20 mA, VDE 0106/EN50178
4 20 mA or PTC), one of which Bus boards for
can be used as an input for a tem- Profibus-DP-V1, Profinet*, Modbus
perature sensor TCP, Modbus RTU, Ethernet*, In-
terbus-S*, CANopen*, DeviceNet*,
ControlNet*
* being prepared

Peripheral board 1 Peripheral board 2 Peripheral board 3 Peripheral board 4

2 PTC thermistor inputs for ATEX-


certified (only DYNAVERT T)
motor temperature monitoring
for motors located in hazardous
zones (alarm/trip)

One "safe standstill" digital input


acc. to ISO 13849-1, Cat. 3, PL d
or SIL 2 acc. to IEC 61508

9 digital inputs (DI)

3 relay outputs (DO)

3 relay outputs (DO)

24 V, 300 mA power supply unit

7
Loher DYNAVERT
the advantages at a glance

All DYNAVERT drive units are op- The transparently structured IMS* ASCII import of all parameters
erated in the same way. This not PC operator program for com- to automatically generate
only involves the compact units munications between the PC and parameter sets
from 2.2 kW to 200 kW, but also drive inverter via USB, RS232, Learning expert system
the cabinet units up to 6,600 kW. RS485 or Profibus DP-V1 include Fault message and diagnostics
the following functions: evaluation
Operator control with multi-
* Can be downloaded at no charge under
language plain text display and Prompted commissioning and www.loher.com
membrane operator control
keypad is both intuitive and ex- Online/offline Parametrierung
tremely straightforward. Setpoints Oscilloscope function
and parameters can be easily and It is possible to toggle between
transparently set using the menu parameter and terminal strip
structure. view
Function and message
Advantages generators
It is possible to toggle between
User-friendly operator control various languages
using a menu-prompted plain Extensive conversion and
text display comparison functions
Standard operator control Comments can be entered for
across the complete product all function terminals and
series messages
Communications via terminal Upread and download
strip, serial interfaces, Profibus RS485 bus system with up to
DP-V1, Modbus RTU or Modbus 253 drive inverters connected
TCP to a PC

8
Services and Features

Explosion protection* Operator control and setting The following generally apply
ATEX-certified for motors located in Transparent operator control and Automatic slip compensation
hazardous zones setting using a menu-prompted Stall protection using current
A main contactor is not required 4-line plain text display with mem- limiting control
brane keypad at the drive inverter Flying restart circuit to connect
Safe Torque Off or up to 1,000 m away in the main to a rotating motor
The Safe Torque Off function pre- control room via RS485 Automatic adaptation of the
vents unexpected starting in com- Extensive functions using the overload times
pliance with EN60204-1, realised Windows-based PC operator control Parameterizable DC braking for
according to ISO 13849-1 cat. 3, program precise braking down to standstill
PL d and SIL 2 acc. to IEC 61508 Closed-loop torque control
respectively Communication
Communication via a conventional *only for DYNAVERT T
Power unit terminal strip with freely-program-
This corresponds to the EMC Direc- mable digital and analog inputs/
tives (EN61800-3 environment 1 outputs, with
and 2) as a result of the line filter parameterizable logic elements
integrated as standard parameterizable limit value signals
Low harmonics fed back into the parameterizable timers
line supply as a result of the inte- parameterizable logic elements
grated line reactor parameterizable damping
Output filter to permit longer elements
motor cables for DYNAVERT T or parameterizable drive inverter
inherent to the system almost behavior when inputs/outputs
unlimited motor cable lengths for respond
DYNAVERT I Communication and parameteriza-
Insulation monitoring for IT line tion via
supplies for 500/690 V drive units PC using IMS (Inverter Manage-
as well as ground fault monitoring ment Software) via USB
for TN and TT line supplies integrat- external operator panel via RS485
ed in the 400 V drive units bus systems such as Profibus DP-
Wide supply voltage range V1, Modbus RTU or Modbus TCP
Low motor noise and low drive in-
verter and motor losses as a result Drive behavior for DYNAVERT T
of the optimized pulse pattern* Synchronous and asynchronous
Normal fuses can be used for pro- motors
tection (gL characteristic) can be controlled
Optional wih Line Harmonics Filter Two closed-loop control types for
or Active Front End induction motors:
field-oriented control for
Control section applications demanding a
High level of personnel and plant high dynamic performance
protection through protective space-vector control for standard
separation between the analog and applications (without feedback)
digital control peripheral and the Optimum braking without
power unit according to VDE 0106/ supplementary equipment using
EN50178 super-saturation control

9
DYNAVERT T versions and design

Housing design for compact units Cabinet systems

Rugged aluminium housing Compact drive units are complemented


Degree of protection IP20, by a Rittal TS8 cabinet and control
optionally IP21 accessories to form cabinet systems.
Generous terminal space for connect-
ing cables in compliance with EMC
Directives
Complete shock hazard protection
Exchange of the fans during operation

Advantages of the cabinet system

Cost-optimized customized design using a modular system


The complete system can be simply and quickly assembled by integrating various,
industry sector-specific control packages
High degree of flexibility and short delivery times by using CAE/CAM systems
Can be integrated into any control concept using customer-specific versions
Can be adapted to many bus systems
Space-optimized overall concept
Rittal TS8 cabinet system guaranteeing worldwide acceptance
Optimum space utilization through various cabinet sizes
Can be simply adapted to the widest range of climatic conditions
Simple to service and maintain as all of the components can be accessed from the front

Number of compact units in the particular cabinet system


*without additional control or with accessory kit N

Compact unit width Compact system width


600 mm 800 mm 1.000 mm 1.200 mm
165 mm 3 / 6* 4 / 8* 5 / 10* 6 / 12*
2.2 kW 11 kW (400 V)
2.2 kW 15 kW (500 V)
225 mm 2 / 4* 3 / 6* 4 / 8* 4 / 8*
15 kW 30 kW (400 V)
22 kW 37 kW (500 V)
7,5 kW - 22 kW (690V)
350 mm 1 2 2 3
37 kW 110 kW (400 V)
45 kW 132 kW (500 V)
30 kW 132 kW (690 V)
500 mm 1 1 1 2
132 kW 160 kW (400 V)
160 kW 200 kW (500 V)
160 kW 200 kW (690 V)

10
Cabinet unit design
Rittal TS8 electrical cabinet
IP21 degree of protection higher degree of Air discharge Inner cooling
protection optionally available air circuit

Integrated cable clamping bar and


cable shield rail
Generous terminal space for connecting
cables in-line with EMC Directives
Complete shock hazard protection

Cabinet units with direct water cooling


No thermal load in electrical rooms
Can be used almost everywhere as a result
of the IP55 degree of protection (display, IP54)
Inner air cooler
even in environments that are damaging to
machinery
Water outlet Fan
Reliable even at high ambient temperatures
up to 55C (131F) through the optimum Water inlet
cooling system
Lower noise as there is no forced ventilation
Improved efficiency
The cooling system operates with almost any
water quality thanks to the stainless steel com-
ponents used in the water circuit
11
DYNAVERT T
Standard accessory kits from 2.2 kW up to 6,600 kW

Accessory kit Q Accessory kit D


Main switch as load disconnector Main switch as load disconnector
with door handle with door handle
Changeover switch for local/remote Possibility of disconnecting the
operation - mounted in the cabinet inverter from the line supply at
door the input side
Peripheral board 2, including ATEX- Inverter contactor at the output
certified PTC input side
Bypass contactor
Accessory kit N Motor monitoring also in bypass
Terminal block according to NAMUR operation
Empfehlung NE37 Changeover switch for local/remote
Peripheral board 4, incl. forced line operation - mounted in the cabinet
disconnection, implemented in door
compliance with ISO 13849-1 up to Manual or automatic bypass
Cat. 3 PL d or SIL 2 acc. to IEC changeover
61508 and ATEX-certified PTC input
Changeover switch for test-normal
operation mounted in the cabinet

Accessory kit S
Main switch as load disconnector
with door handle
Main contactor to disconnect from
the line supply in a safety-relevant
fashion
Emergency Off safety relay accord-
ing to ISO 13849-1 or SIL1* acc. to
IEC 61508
Emergency Off button and Emer-
gency Off reset in the cabinet door
Changeover switch for local/remote
operation - mounted in the cabinet
door
Peripheral board 2, including ATEX-
certified PTC input

Communication accessories
i.e. for remote maintenance
various Ethernet coupler or
modem

Accessories to comply with IEEE519


Line Harmonics Filter
Active Front End

* SIL2/3 on request
12
General technical data
DYNAVERT T

Line supply voltage 2T..-..400-002160 3~AC 230 ... 500 V (for TN/TT line sup-
+10%, -15% 2T..-..401-200630 plies)
+40%, optional, on request 2T..-..50.-... 3~AC 230 415 V (for TN/TT line sup-
2T..-..69.-... plies)
3~AC 230 ... 500 V (for IT line supplies)
3~AC 400 ... 690 V (for TN/TT/IT line sup-
plies)

Line supply cos phi (1) approx. 0.99

Line supply frequency 47 ... 63 Hz

Maximum output frequency 120 250 Hz***

Output voltage (basic fundamental) 3 x 0 ... line supply voltage

Clock frequency 1.5 ... 10 kHz, can be parameterized***

Typical motor cable length 2T..-..400-... (compact) 200 m standard*


(detailed information in the manual) 2T..-..401-... (cabinet) 300 m standard
2T..-..50.-... 300 m standard
2T..-..69.-... 100 m standard**

Degree of protection Compact drive units: IP20


Cabinet units/systems: IP21, higher degrees of protection
are optionally available

* 350 m filter can be optionally integrated into the drive unit


** 300 m filter can be optionally integrated into the drive unit with larger dimensions
*** Setting range depends on the unit power rating

13
General technical data compact units

DYNAVERT T 400 V 6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2T2A07400-002 6SE0102-1AA15-5AA5 3.7 5.5 6.5 2.2 410 x 165 x 320


2T2A07400-003 6SE0102-1AA17-0AA5 4.6 7 8 3 410 x 165 x 320
2T2A07400-004 6SE0102-1AA21-0AA5 6.4 9.5 11 4 410 x 165 x 320
2T2A07400-005 6SE0102-1AA21-3AA5 8.6 13 15 5.5 410 x 165 x 320
2T2A07400-007 6SE0102-1AA21-8AA5 12.1 18 20 7.5 510 x 165 x 320
2T2A07400-011 6SE0102-1AA22-5AA5 16 24.5 27 11 510 x 165 x 320
2T2A07400-015 6SE0102-1AA23-7AA5 24.4 37 44 15 610 x 225 x 320
2T2A07400-022 6SE0102-1AA24-8AA5 32 48 54 22 610 x 225 x 320
2T2A07400-030 6SE0102-1AA25-8AA5 39.2 58 63 30 610 x 225 x 320
2T2A07400-037 6SE0102-1AA27-8AA5 52.3 78 88 37 710 x 350 x 320
2T2A07400-045 6SE0102-1AA28-8AA5 57.5 88 110 45 710 x 350 x 320
2T2A07400-055 6SE0102-1AA31-1AA5 74.8 110 126 55 710 x 350 x 320
2T2A07400-075 6SE0102-1AA31-5AA5 98.4 145 165 75 1060 x 350 x 320
2T2A07400-090 6SE0102-1AA31-8AA5 119 175 204 90 1060 x 350 x 320
2T2A07400-110 6SE0102-1AA32-1AA5 136 205 240 110 1060 x 350 x 320
2T2A07400-132 6SE0102-1AA32-5AA5 161 245 300 132 1060 x 500 x 320
2T2A07400-160 6SE0102-1AA33-0AA5 197 295 360 160 1060 x 500 x 320

DYNAVERT T 500 V 6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2T2A07500-002 6SE0102-1AB14-5AA5 3.8 4.5 5 2.2 410 x 165 x 320


2T2A07500-003 6SE0102-1AB15-5AA5 4.5 5.5 6.5 3 410 x 165 x 320
2T2A07500-004 6SE0102-1AB17-0AA5 5.8 7 8 4 410 x 165 x 320
2T2A07500-005 6SE0102-1AB21-0AA5 8.2 9.5 11 5.5 410 x 165 x 320
2T2A07500-007 6SE0102-1AB21-3AA5 10.9 13 15 7.5 410 x 165 x 320
2T2A07500-011 6SE0102-1AB21-8AA5 15.2 18 20 11 510 x 165 x 320
2T2A07500-015 6SE0102-1AB22-5AA5 20.4 24.5 27 15 510 x 165 x 320
2T2A07500-022 6SE0102-1AB23-7AA5 31.3 37 44 22 610 x 225 x 320
2T2A07500-030 6SE0102-1AB24-8AA5 40.5 48 54 30 610 x 225 x 320
2T2A07500-037 6SE0102-1AB25-8AA5 49.6 58 63 37 610 x 225 x 320
2T2A07500-045 6SE0102-1AB27-8AA5 64.2 78 88 45 710 x 350 x 320
2T2A07500-055 6SE0102-1AB28-8AA5 76.1 88 110 55 710 x 350 x 320
2T2A07500-075 6SE0102-1AB31-1AA5 94.4 110 126 75 710 x 350 x 320
2T2A07500-090 6SE0102-1AB31-5AA5 124 145 165 90 1060 x 350 x 320
2T2A07500-110 6SE0102-1AB31-8AA5 147 175 204 110 1060 x 350 x 320
2T2A07500-132 6SE0102-1AB32-1AA5 171 205 240 132 1060 x 350 x 320
2T2A07500-160 6SE0102-1AB32-5AA5 206 245 300 160 1060 x 500 x 320
2T2A07500-200 6SE0102-1AB33-0AA5 248 295 360 200 1060 x 500 x 320

DYNAVERT T 690 V 6-pulse Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2T2A07690-007 6SE0102-1AC21-0AA5 11.7 9.5 11 7.5 610 x 225 x 320


2T2A07690-011 6SE0102-1AC21-3AA5 15.3 13 16 11 610 x 225 x 320
2T2A07690-015 6SE0102-1AC21-8AA5 22.1 18.5 22 15 610 x 225 x 320
2T2A07690-022 6SE0102-1AC22-7AA5 32.4 27.1 33 22 610 x 225 x 320
2T2A07690-030 6SE0102-1AC23-4AA5 45.5 36 45 30 710 x 350 x 320
2T2A07690-037 6SE0102-1AC24-2AA5 52.6 43 55 37 710 x 350 x 320
2T2A07690-045 6SE0102-1AC25-0AA5 60.9 50 65 45 710 x 350 x 320
2T2A07690-055 6SE0102-1AC25-8AA5 74 60 75 55 710 x 350 x 320
2T2A07690-075 6SE0102-1AC28-0AA5 97.9 80 90 75 710 x 350 x 320
2T2A07690-090 6SE0102-1AC31-0AA5 123 95 120 90 1060 x 350 x 320
2T2A07690-110 6SE0102-1AC31-2AA5 143 120 140 110 1060 x 350 x 320
2T2A07690-132 6SE0102-1AC31-4AA5 184 150 175 132 1060 x 350 x 320
2T2A07690-160 6SE0102-1AC31-7AA5 216 175 210 160 1060 x 500 x 320
2T2A07690-200 6SE0102-1AC32-1AA5 266 210 255 200 1060 x 500 x 320

14
General technical data cabinet units
400 V und 500 V
DYNAVERT T 400 V 6-pulse1 Output Mechanical system

Order No.
Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous Short-time Shaft
Inverter type water cooling [kVA] current [A] current*[A] output** [kW] H x W x D

2T3A-87401-200 6SE0183-1BA34-2AA6/ 2002


249 380 470 200 x 806 x 605
2T3A-77401-200 6SE0176-1BA34-2AA6 2202
2T3A-87401-250 6SE0183-1BA34-7AA6/ 2002
300 460 560 250 x 806 x 605
2T3A-77401-250 6SE0176-1BA34-7AA6 2202
2T3A-87401-315 6SE0183-1BA35-8AA6/ 2002
403 630 700 315 x 806 x 605
2T3A-77401-315 6SE0176-1BA35-8AA6 2202
2T3A-87401-400 6SE0183-1BA37-0AA6/ 2002
476 740 950 400 x 1206 x 605
2T3A-77401-400 6SE0176-1BA37-0AA6 2202
2T3A-87401-500 6SE0183-1BA38-7AA6/ 2002 1606
602 910 1110 500 x x 605
2T3A-77401-500 6SE0176-1BA38-7AA6 2202 1806
2T3A-87401-560 6SE0183-1BA41-0AA6/ 2002 1606
675 1020 1230 560 x x 605
2T3A-77401-560 6SE0176-1BA41-0AA6 2202 1806
2T3A-87401-630 6SE0183-1 BA41-1AA6/ 2002 1606
761 1140 1370 630 x x 605
2T3A-77401-630 6SE0176-1BA41-1AA6 2202 1806

DYNAVERT T 500 V 6-pulse1 Output Mechanical system

Order No.
Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous Short-time Shaft
Inverter type water cooling [kVA] current [A] current*[A] output** [kW] H x W x D

2T3A-87501-250 6SE0183-1BB34-2AA6/ 2002


303 370 450 250 x 806 x 605
2T3A-77501-250 6SE0176-1BB34-2AA6 2202
2T3A-87501-315 6SE0183-1BB34-6AA6/ 2002
378 460 560 315 x 806 x 605
2T3A-77501-315 6SE0176-1BB34-6AA6 2202
2T3A-87501-400 6SE0183-1BB36-0AA6/ 2002
514 640 700 400 x 806 x 605
2T3A-77501-400 6SE0176-1BB36-0AA6 2202
2T3A-87501-500 6SE0183-1BB37-0AA6/ 2002
606 730 950 500 x 1206 x 605
2T3A-77501-500 6SE0176-1BB37-0AA6 2202
2T3A-87501-560 6SE0183-1BB38-2AA6/ 2002 1606
678 820 980 560 x x 605
2T3A-77501-560 6SE0176-1BB38-2AA6 2202 1806
2T3A-87501-630 6SE0183-1BB38-8AA6/ 2002 1606
767 920 1100 630 x x 605
2T3A-77501-630 6SE0176-1BB38-8AA6 2202 1806
2T3A-87501-710 6SE0183-1BB41-0AA6/ 2002 1606
848 1030 1230 710 x x 605
2T3A-77501-710 6SE0176-1BB41-0AA6 2202 1806
2T3A-87501-800 6SE0183-1BB41-1AA6/ 2002 1606
944 1150 1380 800 x x 605
2T6A-77501-800 6SE0176-1BB41-1AA6 2202 1806

1
Inverters with higher pulse numbers, inverters with higher rating or Active Front End on request

* The overload time is automatically controlled (thermal inverter model) however, as a minimum 60 s at an ambient
temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs

15
DYNAVERT T 690 V 6-pulse1 Output Mechanical system

Order No. Short-time


Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous current* Shaft
Inverter type water cooling [kVA] current [A] [A] output** [kW] H x W x D

2T3A-87691-250 6SE0183-1BC33-2AA6/ 2002


312 270 320 250 x 806 x 605
2T6A-77691-250 6SE0176-1BC33-2AA6 2202
2T3A-87691-315 6SE0183-1BC33-6AA6/ 2002
391 340 410 315 x 806 x 605
2T6A-77691-315 6SE0176-1BC33-6AA6 2202
2T3A-87691-400 6SE0183-1BC34-2AA6/ 2002
502 440 510 400 x 806 x 605
2T6A-77691-400 6SE0176-1BC34-2AA6 2202
2T3A-87691-500 6SE0183-1BC35-2AA6/ 2002
608 530 640 500 x 1206 x 605
2T6A-77691-500 6SE0176-1BC35-2AA6 2202
2T3A-87691-560 6SE0183-1BC35-7AA6/ 2002 1606
676 590 710 560 x x 605
2T6A-77691-560 6SE0176-1BC35-7AA6 2202 1806
2T3A-87691-630 6SE0183-1BC36-4AA6/ 2002 1606
762 660 800 630 x x 605
2T6A-77691-630 6SE0176-1BC36-4AA6 2202 1806
2T3A-87691-710 6SE0183-1BC37-1AA6/ 2002 1606
856 750 890 710 x x 605
2T6A-77691-710 6SE0176-1BC37-1AA6 2202 1806
2T3A-87691-800 6SE0183-1BC37-7AA6/ 2002 1606
956 840 980 800 x x 605
2T6A-77691-800 6SE0176-1BC37-7AA6 2202 1806
2T3A-87691-909 6SE0183-1BC41-0AA6/ 2002 1606
1080 950 1060 900 x x 605
2T6A-77691-909 6SE0176-1BC41-0AA6 2202 1806
2T3A-87691-910 6SE0183-1BC41-1AA6/ 2002 1606
1168 1040 1130 1000 x x 605
2T6A-77691-910 6SE0176-1BC41-1AA6 2202 1806
2T3A-87692-912 6SE0183-1CC41-2AA6/ 2002 3206
1410 1260 1520 1210 x x 605
2T6A-77692-912 6SE0176-1CC41-2AA6 2202 3606
2T3A-87692-913 6SE0183-1CC41-3AA6/ 2002 3206
1603 1430 1700 1380 x x 605
2T6A-77692-913 6SE0176-1CC41-3AA6 2202 3606
2T3A-87692-915 6SE0183-1CC41-5AA6/ 2002 3206
1795 1600 1870 1540 x x 605
2T6A-77692-915 6SE0176-1CC41-5AA6 2202 3606
2T3A-87692-917 6SE0183-1CC41-7AA6/ 2002 3206
2030 1810 2020 1750 x x 605
2T6A-77692-917 6SE0176-1CC41-7AA6 2202 3606
2T3A-87692-919 6SE0183-1CC42-0AA6/ 2002 3206
2223 1980 2150 1910 x x 605
2T6A-77692-919 6SE0176-1CC42-0AA6 2202 3606

Inverters with higher pulse numbers, inverters with higher rating or Active Front End on requeste
1

* The overload time is automatically controlled (thermal inverter model) - however, as a minimum 60s at an ambient temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs.

16
General technical data cabinet units
690 V
DYNAVERT T 690 V 12-pulse1 Output Mechanical system

Order No. Short-time


Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous current* Shaft
Inverter type water cooling [kVA] current [A] [A] output** [kW] H x W x D

2T3F-87691-500 6SE0183-2BC35-2AA6/ 2002


600 530 640 500 x 1406 x 605
2T6F-77691-500 6SE0176-2BC35-2AA6 2202
2T3F-87691-560 6SE0183-2BC35-7AA6/ 2002 1806
667 590 710 560 x x 605
2T6F-77691-560 6SE0176-2BC35-7AA6 2202 2006
2T3F-87691-630 6SE0183-2BC36-4AA6/ 2002 1806
753 660 800 630 x x 605
2T6F-77691-630 6SE0176-2BC36-4AA6 2202 2006
2T3F-87691-710 6SE0183-2BC37-1AA6/ 2002 1806
848 750 890 710 x x 605
2T6F-77691-710 6SE0176-2BC37-1AA6 2202 2006
2T3F-87691-800 6SE0183-2BC37-7AA6/ 2002 1806
949 840 980 800 x x 605
2T6F-77691-800 6SE0176-2BC37-7AA6 2202 2006
2T3F-87691-909 6SE0183-2BC41-0AA6/ 2002 1806
1076 950 1060 900 x x 605
2T6F-77691-909 6SE0176-2BC41-0AA6 2202 2006
2T3F-87691-910 6SE0183-2BC41-1AA6/ 2002 1806
1164 1040 1130 1000 x x 605
2T6F-77691-910 6SE0176-2BC41-1AA6 2202 2006
2T3F-87692-912 6SE0183-2CC41-2AA6/ 2002 3206
1405 1260 1520 1210 x x 605
2T6F-77692-912 6SE0176-2CC41-2AA6 2202 3606
2T3F-87692-913 6SE0183-2CC41-3AA6/ 2002 3206
1597 1430 1700 1380 x x 605
2T6F-77692-913 6SE0176-2CC41-3AA6 2202 3606
2T3F-87692-915 6SE0183-2CC41-5AA6/ 2002 3206
1781 1600 1870 1540 x x 605
2T6F-77692-915 6SE0176-2CC41-5AA6 2202 3606
2T3F-87692-917 6SE0183-2CC41-7AA6/ 2002 3206
2010 1810 2020 1750 x x 605
2T6F-77692-917 6SE0176-2CC41-7AA6 2202 3606
2T3F-87692-919 6SE0183-2CC42-0AA6/ 2002 3206
2199 1980 2150 1910 x x 605
2T6F-77692-919 6SE0176-2DC42-0AA6 2202 3606
2T3F-87693-920 6SE0183-2DC42-2AA6/ 2002 4806
2369 2140 2540 2090 x x 605
2T6F-77693-920 6SE0176-2DC42-2AA6 2202 5206
2T3F-87693-923 6SE0183-2DC42-4AA6/ 2002 4806
2648 2400 2800 2350 x x 605
2T6F-77693-923 6SE0176-2DC42-4AA6 2202 5206
2T3F-87693-926 6SE0183-2DC42-7AA6/ 2002 4806
2983 2710 3030 2650 x x 605
2T6F-77693-926 6SE0176-2DC42-7AA6 2202 5206
2T3F-87693-929 6SE0183-2DC43-0AA6/ 2002 4806
3272 2970 3230 2910 x x 605
2T6F-77693-929 6SE0176-2DC43-0AA6 2202 5206
2T3F-87694-931 6SE0183-2EC43-2AA6/ 2002 6406
3516 3200 3730 3180 x x 605
2T6F-77694-931 6SE0176-2EC43-2AA6 2202 7006
2T3F-87694-935 6SE0183-2EC43-6AA6/ 2002 6406
956 3610 4030 3590 x x 605
2T6F-77694-935 6SE0176-2EC43-6AA6 2202 7006
2T3F-87694-939 6SE0183-2EC44-0AA6/ 2002 6406
4336 3960 4300 3930 x x 605
2T6F-77694-939 6SE0176-2EC44-0AA6 2202 7006

1
Inverters with higher pulse numbers, inverters with higher rating or Active Front End on request

* The overload time is automatically controlled (thermal inverter model) - however, as a minimum 60s at an ambient temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs.

17
DYNAVERT I
6-, 12- and 24-pulse versions

DYNAVERT I drive units are current- Customer-specific accessories are 12/6-pulse version to supply
source DC link inverters that are used available on reques. 3-phase motors
to control induction motors. There
have a fully controlled B6 bridge cir- Drive inverter in a 12-pulse The 2J_F- drive units are only avail-
cuit on the line side and a B6 inverter version able equipped with a 12-pulse line
circuit on the output side, which side converter. This means that they
utilizes the principle of interphase DYNAVERT I drive units are availiable are suitable to feed standard 3-phase
commutation; this distributes the DC in a 12-pulse version to reduce the motors. They comprise two 6-pulse
link current from the DC link reactors harmonics fed back to the line supply. standard units.
with a square waveform with fre- In this case, for instance, the har-
quency f to the motor winding. As a monics with harmonic Nos. 5 and 7
consequence, the motor cable length almost completely disappear. A three-
is almost unlimited. winding transformer with windings
offset through 30 is required to feed
The power flows from the line supply the drive inverter (this is generally
to the motor for a motoring load. For included in the scope of supply).
regenerative operation, the rectifier Depending on the actual version, the
on the line-side feeds the regener- units can also be redundantly config-
ated energy back into the line supply. ured (partial load operation using just
This means that from the inherent one of the system halves).
principle, 4-quadrant operation is
possible without requiring any addi-
tional measures. 12- and 24-pulse
versions further reduce the harmon-
ics fed back into the line supply.

6/6-pulse version to feed D


3-phase motors y d

~ ~ ~


~ ~ ~

3~ 3~

18
12/12-pulse version to supply Drive inverter in a 24-pulse version
6-phase motors
Contrary to the 12-pulse circuits, for
The 2J_D- drive units are suit- this version, the 11th and 13th har-
able for controlling special 6-phase monics of the line current disappear.
motors. This is the reason that they
are mainly used in the upper power gi line supply = 99.9%
range. Highest level of line compatibility
Besides to low line harmonics, ad- Standards are complied with even
ditional advantages include smooth- under difficult line supply charac-
ing motor operation and low motor teristics and even when braking
losses. They comprise two 6-pulse Partial system redundancy possible,
standard units. also for the inverter transformers
Power ratings up to 6 MW
690 V or 950 V supply voltage
(other voltages, e.g. 850 V or 1,100
V, are available on request)

24/12-pulse version to control 6-phase motors

D D+ D-
y d y d y d

~ ~ ~ ~ ~ ~


~ ~ ~ ~ ~ ~

6~ 6~

19
2 systems (master, slave) of a 24-pulse DYNAVERT I

General technical data


DYNAVERT I
Line supply voltage 2J..-.6400-... 3~AC 400 V, 415 V
+10%, -15% 2J..-.6440-... 3~AC 440 V, 460 V
+40%, optional, on request 2J..-.6500-... 3~AC 500 V
2J..-.6690-... 3~AC 690 V
2J..-.6950-... 3~AC 850 ... 1,140 V

Line supply cos phi (1) Depends on the motor

Line frequency 50 Hz. optional 60 Hz

Maximum output frequency 60 Hz, higher on request

Output voltage (basic fundamental) 3 x 0 ... line supply voltage

Motor cable length 500 m, longer on request


(shielded or non-shielded)

Degree of protection IP21, higher degrees of protection


optionally available

20
General technical data
400 V and 500 V
DYNAVERT I 400 V 6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3A-87401-015 6SE0383-1BA23-8AA6 26 38 42 15 2002 x 606 x 605


2J3A-87401-022 6SE0383-1BA25-0AA6 35 50 55 22 2002 x 606 x 605
2J3A-87401-030 6SE0383-1BA26-5AA6 45 65 72 30 2002 x 606 x 605
2J3A-87401-037 6SE0383-1BA28-0AA6 55 80 88 37 2002 x 606 x 605
2J3A-87401-045 6SE0383-1BA31-0AA6 66 95 105 45 2002 x 606 x 605
2J3A-87401-055 6SE0383-1BA31-1AA6 80 115 127 55 2002 x 606 x 605
2J3A-87401-075 6SE0383-1BA31-5AA6 105 150 165 75 2002 x 606 x 605
2J3A-87401-090 6SE0383-1BA31-8AA6 125 180 198 90 2202 x 606 x 605
2J3A-87401-110 6SE0383-1BA32-2AA6 155 225 248 110 2002 x 1206 x 605
2J3A-87401-132 6SE0383-1BA32-6AA6 185 265 292 132 2002 x 1206 x 605
2J3A-87401-160 6SE0383-1BA33-0AA6 210 305 336 160 2002 x 1206 x 605
2J3A-87401-200 6SE0383-1BA33-7AA6 255 370 407 200 2002 x 1206 x 605
2J3A-87401-250 6SE0383-1BA34-8AA6 335 480 530 250 2002 x 1406 x 605
2J3A-87401-315 6SE0383-1BA36-0AA6 415 600 660 315 2002 x 1406 x 605
2J3A-87401-350 6SE0383-1BA36-6AA6 455 660 725 350 2002 x 1406 x 605
2J3A-87401-400 6SE0383-1BA37-2AA6 500 725 800 400 2002 x 2406 x 605
2J3A-87401-500 6SE0383-1BA38-8AA6 665 960 1055 500 2002 x 2406 x 605
2J3A-87401-550 6SE0383-1BA41-0AA6 720 1040 1145 550 2002 x 2406 x 605
2J3A-87401-630 6SE0383-1BA41-1AA6 795 1150 1265 630 2002 x 2406 x 605

DYNAVERT I 500 V 6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3A-87501-015 6SE0383-1BB22-8AA6 25 29 32 15 2002 x 606 x 605


2J3A-87501-022 6SE0383-1BB24-0AA6 35 40 44 22 2002 x 606 x 605
2J3A-87501-030 6SE0383-1BB25-0AA6 43 50 55 30 2002 x 606 x 605
2J3A-87501-037 6SE0383-1BB26-0AA6 52 60 66 37 2002 x 606 x 605
2J3A-87501-045 6SE0383-1BB27-5AA6 65 75 83 45 2002 x 606 x 605
2J3A-87501-055 6SE0383-1BB28-8AA6 78 90 99 55 2002 x 606 x 605
2J3A-87501-075 6SE0383-1BB31-2AA6 105 120 132 75 2002 x 606 x 605
2J3A-87501-090 6SE0383-1BB31-4AA6 125 145 160 90 2202 x 606 x 605
2J3A-87501-110 6SE0383-1BB31-8AA6 155 180 198 110 2002 x 606 x 605
2J3A-87501-132 6SE0383-1BB32-1AA6 185 215 237 132 2002 x 1206 x 605
2J3A-87501-160 6SE0383-1BB32-4AA6 210 240 264 160 2002 x 1206 x 605
2J3A-87501-200 6SE0383-1BB32-8AA6 255 295 325 200 2002 x 1206 x 605
2J3A-87501-250 6SE0383-1BB33-8AA6 330 380 418 250 2002 x 1206 x 605
2J3A-87501-315 6SE0383-1BB34-8AA6 415 480 530 315 2002 x 1406 x 605
2J3A-87501-350 6SE0383-1BB35-3AA6 460 530 585 350 2002 x 1406 x 605
2J3A-87501-400 6SE0383-1BB35-8AA6 500 580 640 400 2002 x 1406 x 605
2J3A-87501-500 6SE0383-1BB37-6AA6 660 760 835 500 2002 x 2406 x 605
2J3A-87501-550 6SE0383-1BB38-4AA6 725 840 925 550 2002 x 2406 x 605
2J3A-87501-630 6SE0383-1BB38-8AA6 800 925 1020 630 2002 x 2406 x 605
2J3A-87501-800 6SE0383-1BB41-2AA6 1040 1200 1320 800 2002 x 2406 x 605
* The overload time is automatically controlled (thermal inverter model) however, as a minimum 60 s at an ambient
temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs
Other voltages on request

21
DYNAVERT I 690 V 6-pulse Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3A-87691-045 6SE0383-1BC25-5AA6 66 55 61 45 2002 x 606 x 605


2J3A-87691-055 6SE0383-1BC26-5AA6 78 65 72 55 2002 x 606 x 605
2J3A-87691-075 6SE0383-1BC28-8AA6 108 90 99 75 2002 x 606 x 605
2J3A-87691-090 6SE0383-1BC31-1AA6 130 110 121 90 2202 x 606 x 605
2J3A-87691-110 6SE0383-1BC31-3AA6 160 135 149 110 2202 x 606 x 605
2J3A-87691-132 6SE0383-1BC31-5AA6 185 155 171 132 2202 x 606 x 605
2J3A-87691-160 6SE0383-1BC31-7AA6 210 175 193 160 2002 x 1206 x 605
2J3A-87691-200 6SE0383-1BC32-1AA6 255 215 237 200 2002 x 1206 x 605
2J3A-87691-250 6SE0383-1BC32-7AA6 330 275 303 250 2002 x 1206 x 605
2J3A-87691-315 6SE0383-1BC33-4AA6 410 345 380 315 2002 x 1206 x 605
2J3A-87691-350 6SE0383-1BC34-0AA6 465 390 429 350 2002 x 1206 x 605
2J3A-87691-400 6SE0383-1BC34-2AA6 500 420 460 400 2002 x 1406 x 605
2J3A-87691-500 6SE0383-1BC35-5AA6 655 550 605 500 2002 x 1606 x 605
2J3A-87691-550 6SE0383-1BC36-0AA6 715 600 660 550 2002 x 1606 x 605
2J3A-87691-630 6SE0383-1BC36-7AA6 800 670 735 630 2002 x 2406 x 605
2J3A-87691-800 6SE0383-1BC38-7AA6 1040 870 955 800 2002 x 2406 x 605
2J3A-87691-909 6SE0383-1BC38-8AA6 1145 960 1055 900 2002 x 3206 x 605
2J3A-87691-910 6SE0383-1BC41-0AA6 1290 1080 1190 1000 2002 x 3206 x 605
2J3A-87691-911 6SE0383-1BC41-1AA6 1375 1150 1265 1100 2002 x 3206 x 605
2J3A-87691-912 6SE0383-1BC41-3AA6 1600 1340 1475 1200 2002 x 3206 x 605
2J3A-87691-914 6SE0383-1BC41-5AA6 1830 1530 1685 1400 2002 x 3206 x 605

DYNAVERT I 690 V 12/6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3F-87692-220 6SE0383-2CC32-7AA6 320 270 297 220 2002 x 1206 x 605


2J3F-87692-250 6SE0383-2CC33-1AA6 370 310 341 250 2002 x 1206 x 605
2J3F-87692-315 6SE0383-2CC33-5AA6 420 350 385 315 2002 x 2406 x 605
2J3F-87692-400 6SE0383-2CC34-3AA6 510 430 475 400 2002 x 2406 x 605
2J3F-87692-500 6SE0383-2CC35-5AA6 660 550 605 500 2002 x 2406 x 605
2J3F-87692-630 6SE0383-2CC37-0AA6 820 690 760 630 2002 x 2406 x 605
2J3F-87692-700 6SE0383-2CC37-8AA6 930 780 860 700 2002 x 2406 x 605
2J3F-87692-800 6SE0383-2CC38-4AA6 1000 840 925 800 2002 x 2806 x 605
2J3F-87692-910 6SE0383-2CC41-1AA6 1310 1100 1210 1000 2002 x 3206 x 605
2J3F-87692-911 6SE0383-2CC41-2AA6 1430 1200 1320 1100 2002 x 3206 x 605
2J3F-87692-912 6SE0383-2CC41-3AA6 1600 1340 1475 1200 2002 x 4806 x 605
2J3F-87692-916 6SE0383-2CC41-7AA6 2080 1740 1915 1600 2002 x 4806 x 605
2J3F-87692-918 6SE0383-2CC42-0AA6 2290 1920 2110 1800 2002 x 3206 x 1210
2J3F-87692-920 6SE0383-2CC42-1AA6 2580 2160 2375 2000 2002 x 3206 x 1210
2J3F-87692-922 6SE0383-2CC42-3AA6 2750 2300 2530 2200 2002 x 3206 x 1210
2J3F-87692-925 6SE0383-2CC42-6AA6 3200 2680 2950 2500 2002 x 3206 x 1210
2J3F-87692-928 6SE0383-2CC43-0AA6 3660 3060 3365 2800 2002 x 3206 x 1210

DYNAVERT I 690 V 12/12-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3D-87692-315 6SE0383-5CC31-7AA6 420 2*170 2*187 315 2002 x 2406 x 605


2J3D-87692-400 6SE0383-5CC32-0AA6 510 2*209 2*230 400 2002 x 2406 x 605
2J3D-87692-500 6SE0383-5CC32-6AA6 660 2*267 2*297 500 2002 x 2406 x 605
2J3D-87692-630 6SE0383-5CC33-3AA6 820 2*335 2*369 630 2002 x 2406 x 605
2J3D-87692-700 6SE0383-5CC33-7AA6 930 2*378 2*416 700 2002 x 2406 x 605
2J3D-87692-800 6SE0383-5CC34-0AA6 1000 2*407 2*450 800 2002 x 2806 x 605
2J3D-87692-910 6SE0383-5CC35-3AA6 1310 2*534 2*585 1000 2002 x 3206 x 605
2J3D-87692-911 6SE0383-5CC35-8AA6 1430 2*582 2*640 1100 2002 x 3206 x 605
2J3D-87692-912 6SE0383-5CC36-5AA6 1600 2*650 2*715 1200 2002 x 4806 x 605
2J3D-87692-916 6SE0383-5CC38-4AA6 2080 2*844 2*930 1600 2002 x 4806 x 605
2J3D-87692-918 6SE0383-5CC38-8AA6 2290 2*931 2*1025 1800 2002 x 3206 x 1210
2J3D-87692-920 6SE0383-5CC41-0AA6 2580 2*1048 2*1155 2000 2002 x 3206 x 1210
2J3D-87692-922 6SE0383-5CC41-1AA6 2750 2*1116 2*1230 2200 2002 x 3206 x 1210
2J3D-87692-925 6SE0383-5CC41-3AA6 3200 2*1300 2*1430 2500 2002 x 3206 x 1210
2J3D-87692-928 6SE0383-5CC41-4AA6 3660 2*1484 2*1630 2800 2002 x 3206 x 1210
* The overload time is automatically controlled (thermal inverter model) however, as a minimum 60 s at an ambient
temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors. ***Height without mounting lugs
Other voltages on request

22
General technical data
DYNAVERT I 690 V 24/12-pulse Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3G-87694-800 6SE0383-6EC34-1AA6 1020 2*417 2*460 800 2002 x 4806 x 605


2J3G-87694-910 6SE0383-6EC35-3AA6 1320 2*534 2*585 1000 2002 x 4806 x 605
2J3G-87694-912 6SE0383-6EC36-6AA6 1640 2*669 2*735 1200 2002 x 4806 x 605
2J3G-87694-914 6SE0383-6EC37-5AA6 1860 2*757 2*835 1400 2002 x 4806 x 605
2J3G-87694-916 6SE0383-6EC38-1AA6 2000 2*815 2*895 1600 2002 x 5606 x 605
2J3G-87694-920 6SE0383-6EC41-0AA6 2620 2*1067 2*1175 2000 2002 x 6406 x 605
2J3G-87694-922 6SE0383-6EC41-1AA6 2860 2*1164 2*1280 2200 2002 x 6406 x 605
2J3G-87694-924 6SE0383-6EC41-3AA6 3200 2*1300 2*1430 2400 2002 x 4806 x 1210
2J3G-87694-932 6SE0383-6EC41-6AA6 4160 2*1688 2*1855 3200 2002 x 4806 x 1210
2J3G-87694-936 6SE0383-6EC41-8AA6 4580 2*1862 2*2050 3600 2002 x 6406 x 1210
2J3G-87694-940 6SE0383-6EC42-0AA6 5160 2*2095 2*2305 4000 2002 x 6406 x 1210
2J3G-87694-944 6SE0383-6EC42-2AA6 5500 2*2231 2*2455 4400 2002 x 6406 x 1210
2J3G-87694-948 6SE0383-6EC42-6AA6 6400 2*2600 2*2860 4800 2002 x 6406 x 1210
2J3G-87694-956 6SE0383-6EC43-0AA6 7320 2*2968 2*3265 5600 2002 x 6406 x 1210

DYNAVERT I 950 V 6-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3A-87951-630 6SE0383-1BJ34-8AA6 805 490 539 630 2002 x 2406 x 605


2J3A-87951-800 6SE0383-1BJ36-3AA6 1035 630 693 800 2002 x 2406 x 605
2J3A-87951-909 6SE0383-1BJ37-0AA6 1150 700 770 900 2002 x 2406 x 605
2J3A-87951-910 6SE0383-1BJ37-8AA6 1298 790 869 1000 2002 x 3206 x 605
2J3A-87951-911 6SE0383-1BJ38-4AA6 1381 840 924 1100 2002 x 3206 x 605
2J3A-87951-912 6SE0383-1BJ38-8AA6 1578 960 1056 1200 2002 x 3206 x 605
2J3A-87951-915 6SE0383-1BJ41-1AA6 1939 1180 1298 1500 2002 x 3206 x 605

DYNAVERT I 950 V 12/12-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3D-87952-912 6SE0383-2CJ41-0AA6 1610 2*475 2*525 1200 2002 x 4806 x 605


2J3D-87952-916 6SE0383-2CJ41-2AA6 2070 2*611 2*670 1600 2002 x 4806 x 605
2J3D-87952-918 6SE0383-2CJ41-4AA6 2300 2*679 2*745 1800 2002 x 4806 x 605
2J3D-87952-920 6SE0383-2CJ41-5AA6 2600 2*766 2*845 2000 2002 x 3206 x 1210
2J3D-87952-922 6SE0383-2CJ41-6AA6 2760 2*815 2*895 2200 2002 x 3206 x 1210
2J3D-87952-925 6SE0383-2CJ41-8AA6 3160 2*931 2*1025 2500 2002 x 3206 x 1210
2J3D-87952-930 6SE0383-2CJ42-3AA6 3880 2*1145 2*1260 3000 2002 x 3206 x 1210

DYNAVERT I 950 V 24/12-pulse1 Output Mechanical system

Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D

2J3G-87954-960 6SE0383-6EI42-2AA6 7760 2*2289 2*2520 6000 2002 x 6406 x 1210


1
Additional types on request
* The overload time is automatically controlled (thermal inverter model) however, as a minimum 60 s at an ambient
temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs
Other voltages (e.g. 850 V or 1,100 V) on request

23
The information provided in this brochure contains merely
general descriptions or characteristics of performance
Loher GmbH Subject to change without prior notice
which in case of actual use do not always apply as described
A Siemens Company Order No.: E20001-A40-P580-V2-7600 or which may change as a result of further development
DISPO 21503 of the products. An obligation to provide the respective
Hans-Loher-Str. 32 GD.LD.XX.LOHE.52.0.05 WS 09102. characteristics shall only exist if expressly agreed in the
94099 RUHSTORF Printed in Germany terms of contract.
GERMANY Siemens AG 2010