Individual Solutions For Demanding Sectors: DYNAVERT Drives
Individual Solutions For Demanding Sectors: DYNAVERT Drives
DYNAVERT Drives
Loher stands for
quality and reliability
Loher, with its headquarters in Ruhstorf close to Passau, Germany, is one of the few suppliers
that can offer the complete range of electric drive technology. Loher can look back on 100 years of
tradition in the design and construction of electric motors for more than 40 years, state-of-the-art
2
Loher drive inverters and motors
Intelligent drive systems from a single source
We are more than willing to clearly Loher quality something that you can
document both function and quality always depend on:
for you! We are certified to DIN ISO 9001 and we
are regularly subject to stringent quality
We offer complete drive systems, com- audits from independent institutions.
prising transformers, drive inverters and
motor from a single source! As system
supplier, we provide the complete drive Complete drive from a single
package. Our customers clearly see this source and therefore also clear
as the most important advantage. responsibility for the complete
drive
To prove the function of our drive Customer acceptance tests in
systems, we have our own test field the factory in compliance with
equipped with state-of-the-art equipment all of the relevant standards and
that is available for customer acceptance regulations
tests. In addition to visual and function Certified according to
checks and tests, in the presence of cus- DIN ISO 9001
tomers, we can also document the power Our test stands are equipped to
rating, the efficiency of the complete handle drives up to 6,000 kVA incl.
drive as well as the line supply behavior. load and measuring equipments
3
Four decades providing
the highest reliability and availability
Loher DYNAVERT drive inverters have already been in service for over four decades.
For applications where topmost priority is given to the highest degree of reliability and
DYNAVERT was specifically designed All of the drive requirements are taken
for the following sectors right from the into consideration from the word go
very start from the coupling, through the motor,
cables, drive inverter, line supply sit-
Chemical industry uation and connection to the supervisory
Oil and gas industries control system.
Power stations and utilities
Plastic industry Our many years of experience and
Basic materials industry competence as a motor manufacturer
Test stands have been efficiently incorporated in the
Conveyor technology design and adaptation of DYNAVERT, as
and applications in general machinery motors and drive inverters are developed,
construction. closely harmonized with one another.
Advantages
4
Loher DYNAVERT
compact and cabinet units
Power ranges, DYNAVERT T
690 V
DYNAVERT T
500 V
compact units
400 V
690 V
DYNAVERT T
cabinet systems/ 500 V
cabinet units
400 V
kW
2.2
3
4
5.5
7.5
11
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
550
630
710
800
900
1000
1200
...
6600
Power ranges, DYNAVERT I
950 V
690 V
DYNAVERT I
cabinet units 500 V
400 V
kW
15
22
30
37
45
55
75
90
110
132
160
200
250
315
400
500
550
630
710
800
900
1000
1200
1600
1800
2000
...
...
...
5600
Other power ranges / voltages 6000
on request
5
Loher DYNAVERT
Compact and complete from 2.2 kW to 6,600 kW
6
Loher DYNAVERT
Highly versatile through distributed intelligence in the drive inverter
Terminal strip in compliance with 2 freely parameterizable analog Peripheral board 1...4
NAMUR Recommendation NE37, outputs (0 10 V, 0 20 mA, HTL encoder
with 4 20 mA) with automatic change- RS485 for an external operator
4 freely parameterizable digital over between current and voltage panel
relay outputs output RS232 for PC
parameterizable group fault SIN-COS tachometer
contact A field-orientated controller is also Technology board
12 freely parameterizable digital available for DYNAVERT T to ad- Relay
inputs, 2 of which can be used dress applications that demand a Protective separation according to
either as PTC thermistor inputs high dynamic performance. VDE 0106/EN50178
or pulse inputs Optocoupler
2 freely parameterizable analog Protective separation according to
inputs (0 10 V, 0 20 mA, VDE 0106/EN50178
4 20 mA or PTC), one of which Bus boards for
can be used as an input for a tem- Profibus-DP-V1, Profinet*, Modbus
perature sensor TCP, Modbus RTU, Ethernet*, In-
terbus-S*, CANopen*, DeviceNet*,
ControlNet*
* being prepared
7
Loher DYNAVERT
the advantages at a glance
All DYNAVERT drive units are op- The transparently structured IMS* ASCII import of all parameters
erated in the same way. This not PC operator program for com- to automatically generate
only involves the compact units munications between the PC and parameter sets
from 2.2 kW to 200 kW, but also drive inverter via USB, RS232, Learning expert system
the cabinet units up to 6,600 kW. RS485 or Profibus DP-V1 include Fault message and diagnostics
the following functions: evaluation
Operator control with multi-
* Can be downloaded at no charge under
language plain text display and Prompted commissioning and www.loher.com
membrane operator control
keypad is both intuitive and ex- Online/offline Parametrierung
tremely straightforward. Setpoints Oscilloscope function
and parameters can be easily and It is possible to toggle between
transparently set using the menu parameter and terminal strip
structure. view
Function and message
Advantages generators
It is possible to toggle between
User-friendly operator control various languages
using a menu-prompted plain Extensive conversion and
text display comparison functions
Standard operator control Comments can be entered for
across the complete product all function terminals and
series messages
Communications via terminal Upread and download
strip, serial interfaces, Profibus RS485 bus system with up to
DP-V1, Modbus RTU or Modbus 253 drive inverters connected
TCP to a PC
8
Services and Features
Explosion protection* Operator control and setting The following generally apply
ATEX-certified for motors located in Transparent operator control and Automatic slip compensation
hazardous zones setting using a menu-prompted Stall protection using current
A main contactor is not required 4-line plain text display with mem- limiting control
brane keypad at the drive inverter Flying restart circuit to connect
Safe Torque Off or up to 1,000 m away in the main to a rotating motor
The Safe Torque Off function pre- control room via RS485 Automatic adaptation of the
vents unexpected starting in com- Extensive functions using the overload times
pliance with EN60204-1, realised Windows-based PC operator control Parameterizable DC braking for
according to ISO 13849-1 cat. 3, program precise braking down to standstill
PL d and SIL 2 acc. to IEC 61508 Closed-loop torque control
respectively Communication
Communication via a conventional *only for DYNAVERT T
Power unit terminal strip with freely-program-
This corresponds to the EMC Direc- mable digital and analog inputs/
tives (EN61800-3 environment 1 outputs, with
and 2) as a result of the line filter parameterizable logic elements
integrated as standard parameterizable limit value signals
Low harmonics fed back into the parameterizable timers
line supply as a result of the inte- parameterizable logic elements
grated line reactor parameterizable damping
Output filter to permit longer elements
motor cables for DYNAVERT T or parameterizable drive inverter
inherent to the system almost behavior when inputs/outputs
unlimited motor cable lengths for respond
DYNAVERT I Communication and parameteriza-
Insulation monitoring for IT line tion via
supplies for 500/690 V drive units PC using IMS (Inverter Manage-
as well as ground fault monitoring ment Software) via USB
for TN and TT line supplies integrat- external operator panel via RS485
ed in the 400 V drive units bus systems such as Profibus DP-
Wide supply voltage range V1, Modbus RTU or Modbus TCP
Low motor noise and low drive in-
verter and motor losses as a result Drive behavior for DYNAVERT T
of the optimized pulse pattern* Synchronous and asynchronous
Normal fuses can be used for pro- motors
tection (gL characteristic) can be controlled
Optional wih Line Harmonics Filter Two closed-loop control types for
or Active Front End induction motors:
field-oriented control for
Control section applications demanding a
High level of personnel and plant high dynamic performance
protection through protective space-vector control for standard
separation between the analog and applications (without feedback)
digital control peripheral and the Optimum braking without
power unit according to VDE 0106/ supplementary equipment using
EN50178 super-saturation control
9
DYNAVERT T versions and design
10
Cabinet unit design
Rittal TS8 electrical cabinet
IP21 degree of protection higher degree of Air discharge Inner cooling
protection optionally available air circuit
Accessory kit S
Main switch as load disconnector
with door handle
Main contactor to disconnect from
the line supply in a safety-relevant
fashion
Emergency Off safety relay accord-
ing to ISO 13849-1 or SIL1* acc. to
IEC 61508
Emergency Off button and Emer-
gency Off reset in the cabinet door
Changeover switch for local/remote
operation - mounted in the cabinet
door
Peripheral board 2, including ATEX-
certified PTC input
Communication accessories
i.e. for remote maintenance
various Ethernet coupler or
modem
* SIL2/3 on request
12
General technical data
DYNAVERT T
Line supply voltage 2T..-..400-002160 3~AC 230 ... 500 V (for TN/TT line sup-
+10%, -15% 2T..-..401-200630 plies)
+40%, optional, on request 2T..-..50.-... 3~AC 230 415 V (for TN/TT line sup-
2T..-..69.-... plies)
3~AC 230 ... 500 V (for IT line supplies)
3~AC 400 ... 690 V (for TN/TT/IT line sup-
plies)
13
General technical data compact units
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
14
General technical data cabinet units
400 V und 500 V
DYNAVERT T 400 V 6-pulse1 Output Mechanical system
Order No.
Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous Short-time Shaft
Inverter type water cooling [kVA] current [A] current*[A] output** [kW] H x W x D
Order No.
Dimension*** [mm]
(MLFB) air cooling/ Connection power Continuous Short-time Shaft
Inverter type water cooling [kVA] current [A] current*[A] output** [kW] H x W x D
1
Inverters with higher pulse numbers, inverters with higher rating or Active Front End on request
* The overload time is automatically controlled (thermal inverter model) however, as a minimum 60 s at an ambient
temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs
15
DYNAVERT T 690 V 6-pulse1 Output Mechanical system
Inverters with higher pulse numbers, inverters with higher rating or Active Front End on requeste
1
* The overload time is automatically controlled (thermal inverter model) - however, as a minimum 60s at an ambient temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs.
16
General technical data cabinet units
690 V
DYNAVERT T 690 V 12-pulse1 Output Mechanical system
1
Inverters with higher pulse numbers, inverters with higher rating or Active Front End on request
* The overload time is automatically controlled (thermal inverter model) - however, as a minimum 60s at an ambient temperature of 40C.
** Typical mechanical shaft output with conventional 2- to 6-pole standard motors.
*** Height without mounting lugs.
17
DYNAVERT I
6-, 12- and 24-pulse versions
DYNAVERT I drive units are current- Customer-specific accessories are 12/6-pulse version to supply
source DC link inverters that are used available on reques. 3-phase motors
to control induction motors. There
have a fully controlled B6 bridge cir- Drive inverter in a 12-pulse The 2J_F- drive units are only avail-
cuit on the line side and a B6 inverter version able equipped with a 12-pulse line
circuit on the output side, which side converter. This means that they
utilizes the principle of interphase DYNAVERT I drive units are availiable are suitable to feed standard 3-phase
commutation; this distributes the DC in a 12-pulse version to reduce the motors. They comprise two 6-pulse
link current from the DC link reactors harmonics fed back to the line supply. standard units.
with a square waveform with fre- In this case, for instance, the har-
quency f to the motor winding. As a monics with harmonic Nos. 5 and 7
consequence, the motor cable length almost completely disappear. A three-
is almost unlimited. winding transformer with windings
offset through 30 is required to feed
The power flows from the line supply the drive inverter (this is generally
to the motor for a motoring load. For included in the scope of supply).
regenerative operation, the rectifier Depending on the actual version, the
on the line-side feeds the regener- units can also be redundantly config-
ated energy back into the line supply. ured (partial load operation using just
This means that from the inherent one of the system halves).
principle, 4-quadrant operation is
possible without requiring any addi-
tional measures. 12- and 24-pulse
versions further reduce the harmon-
ics fed back into the line supply.
~ ~ ~
~ ~ ~
3~ 3~
18
12/12-pulse version to supply Drive inverter in a 24-pulse version
6-phase motors
Contrary to the 12-pulse circuits, for
The 2J_D- drive units are suit- this version, the 11th and 13th har-
able for controlling special 6-phase monics of the line current disappear.
motors. This is the reason that they
are mainly used in the upper power gi line supply = 99.9%
range. Highest level of line compatibility
Besides to low line harmonics, ad- Standards are complied with even
ditional advantages include smooth- under difficult line supply charac-
ing motor operation and low motor teristics and even when braking
losses. They comprise two 6-pulse Partial system redundancy possible,
standard units. also for the inverter transformers
Power ratings up to 6 MW
690 V or 950 V supply voltage
(other voltages, e.g. 850 V or 1,100
V, are available on request)
D D+ D-
y d y d y d
~ ~ ~ ~ ~ ~
~ ~ ~ ~ ~ ~
6~ 6~
19
2 systems (master, slave) of a 24-pulse DYNAVERT I
20
General technical data
400 V and 500 V
DYNAVERT I 400 V 6-pulse1 Output Mechanical system
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
21
DYNAVERT I 690 V 6-pulse Output Mechanical system
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
22
General technical data
DYNAVERT I 690 V 24/12-pulse Output Mechanical system
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
Dimension*** [mm]
Order No. Connection power Continuous Short-time Shaft
Inverter type (MLFB) [kVA] current [A] current*[A] output** [kW] H x W x D
23
The information provided in this brochure contains merely
general descriptions or characteristics of performance
Loher GmbH Subject to change without prior notice
which in case of actual use do not always apply as described
A Siemens Company Order No.: E20001-A40-P580-V2-7600 or which may change as a result of further development
DISPO 21503 of the products. An obligation to provide the respective
Hans-Loher-Str. 32 GD.LD.XX.LOHE.52.0.05 WS 09102. characteristics shall only exist if expressly agreed in the
94099 RUHSTORF Printed in Germany terms of contract.