6WE Symbol LS 5800 ReferenceGuide
6WE Symbol LS 5800 ReferenceGuide
70-16692-03
Revision A
May 2003
1997-2003 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by
any electrical or mechanical means, without permission in writing from
Symbol. This includes electronic or mechanical means, such as
photocopying, recording, or information storage and retrieval systems.
The material in this manual is subject to change without notice.
The software is provided strictly on an as is basis. All software,
including firmware, furnished to the user is on a licensed basis. Symbol
grants to the user a non-transferable and non-exclusive license to use each
software or firmware program delivered hereunder (licensed program).
Except as noted below, such license may not be assigned, sublicensed, or
otherwise transferred by the user without prior written consent of
Symbol. No right to copy a licensed program in whole or in part is
granted, except as permitted under copyright law. The user shall not
modify, merge, or incorporate any form or portion of a licensed program
with other program material, create a derivative work from a licensed
program, or use a licensed program in a network without written
permission from Symbol. The user agrees to maintain Symbols copyright
notice on the licensed programs delivered hereunder, and to include the
same on any authorized copies it makes, in whole or in part. The user
agrees not to decompile, disassemble, decode, or reverse engineer any
licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to
improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in
connection with, the application or use of any product, circuit, or
application described herein.
No license is granted, either expressly or by implication, estoppel, or
otherwise under any Symbol Technologies, Inc., intellectual property
rights. An implied license only exists for equipment, circuits, and
subsystems contained in Symbol products.
Symbol, Spectrum One, and Spectrum24 are registered trademarks of
Symbol Technologies, Inc. Other product names mentioned in this manual
may be trademarks or registered trademarks of their respective companies
and are hereby acknowledged.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
http://www.symbol.com
Contents
Chapter 2. Set Up
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Input/Output Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Connecting Your Scanner . . . . . . . . . . . . . . . . . . . . . . . 2-4
To an IBM 468x/469x Terminal, Port 9E or Port 17 2-4
To an IBM 468x/469x Terminal, Port 5B RS-232C or Syn-
apse Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
To an RS-232C Host Using the RS-232C Port . . . 2-6
Dual-Port RS-232C . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Connecting a Hand-Held Laser Scanner . . . . . . . . . . . 2-8
Electronic Article Surveillance (EAS) . . . . . . . . . . . . . 2-10
EAS Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
LS 5700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
LS 5800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Stainless Steel Top . . . . . . . . . . . . . . . . . . . . . . . 2-16
Replacing Other Symbol Fixed-Mount Scanners. 2-18
Beeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
i
LS 5700/LS 5800 Product Reference Guide
Chapter 3. Scanning
Scanning Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Rest/Sleep Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
What If... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Scanning Sequence Examples . . . . . . . . . . . . . . . 3-4
Errors While Scanning . . . . . . . . . . . . . . . . . . . . . . 3-4
Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Host Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
RS-232C Port Options . . . . . . . . . . . . . . . . . . . . . . 3-5
Code Types & Options. . . . . . . . . . . . . . . . . . . . . . 3-5
Custom Tailoring . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Decode Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Data Transmission Formats. . . . . . . . . . . . . . . . . . 3-7
Programming Utilities. . . . . . . . . . . . . . . . . . . . . . . 3-7
ii
Contents
iii
LS 5700/LS 5800 Product Reference Guide
iv
Contents
v
LS 5700/LS 5800 Product Reference Guide
vi
Contents
vii
LS 5700/LS 5800 Product Reference Guide
Appendix
UCC/EAN-128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
AIM Code Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
viii
About This Manual
Notational Conventions
The following conventions are used in this document:
Bullets () indicate:
- action items
- lists of alternatives
- lists of required steps that are not necessarily
sequential
Sequential lists (e.g., those that describe step-by-step
procedures) appear as numbered lists.
Related Publications
LS 5700/5800 Quick Reference Guide (p/n 70-16691-xx)
LS 5800 Mounting & EAS Installation Guide
(p/n 70-17856-xx)
ix
LS 5700/LS 5800 Product Reference Guide
Service Information
If you have a problem with your equipment, contact the
Symbol Support Center for your region. See page xi for
contact information. Before calling, have the model
number, serial number, and several of your bar code
symbols at hand.
x
About This Manual
United States 1
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
1-800-653-5350
Canada
Symbol Technologies Canada, Inc.
2540 Matheson Boulevard East
Mississauga, Ontario, Canada L4W 4Z2
905-629-7226
United Kingdom
Symbol Technologies
Symbol Place
Winnersh Triangle, Berkshire RG41 5TP
United Kingdom
0800 328 2424 (Inside UK)
+44 118 945 7529 (Outside UK)
xi
LS 5700/LS 5800 Product Reference Guide
Asia/Pacific
Symbol Technologies Asia, Inc (Singapore Branch)
230 Victoria Street #05-07/09
Bugis Junction Office Tower
Singapore 188024
Tel : +65-6796-9600
Fax : +65-6337-6488
Australia
Symbol Technologies Pty. Ltd.
432 St. Kilda Road
Melbourne, Victoria 3004
1-800-672-906 (Inside Australia)
+61-3-9866-6044 (Outside Australia)
Austria/sterreich
Symbol Technologies Austria GmbH
Prinz-Eugen Strasse 70 / 2.Haus
1040 Vienna, Austria
01-5055794-0 (Inside Austria)
+43-1-5055794-0 (Outside Austria)
Denmark/Danmark
Symbol Technologies AS
Dr. Neergaardsvej 3
2970 Hrsholm
7020-1718 (Inside Denmark)
+45-7020-1718 (Outside Denmark)
xii
About This Manual
xiii
LS 5700/LS 5800 Product Reference Guide
Italy/Italia
Symbol Technologies Italia S.R.L.
Via Cristoforo Columbo, 49
20090 Trezzano S/N Navigilo
Milano, Italy
2-484441 (Inside Italy)
+39-02-484441 (Outside Italy)
Latin America Sales Support
2730 University Dr.
Coral Springs, FL 33065 USA
1-800-347-0178 (Inside United States)
+1-954-255-2610 (Outside United States)
954-340-9454 (Fax)
Mexico/Mxico
Symbol Technologies Mexico Ltd.
Torre Picasso
Boulevard Manuel Avila Camacho No 88
Lomas de Chapultepec CP 11000
Mexico City, DF, Mexico
5-520-1835 (Inside Mexico)
+52-5-520-1835 (Outside Mexico)
xiv
About This Manual
Netherlands/Nederland
Symbol Technologies
Kerkplein 2, 7051 CX
Postbus 24 7050 AA
Varsseveld, Netherlands
315-271700 (Inside Netherlands)
+31-315-271700 (Outside Netherlands)
Norway/Norge
Symbols registered and mailing address:
Symbol Technologies Norway
Hoybratenveien 35 C
N-1055 OSLO, Norway
Symbols repair depot and shipping address:
Symbol Technologies Norway
Enebakkveien 123
N-0680 OSLO, Norway
+47 2232 4375
South Africa
Symbol Technologies Africa Inc.
Block B2
Rutherford Estate
1 Scott Street
Waverly 2090 Johannesburg
Republic of South Africa
11-809 5311 (Inside South Africa)
+27-11-809 5311 (Outside South Africa)
xv
LS 5700/LS 5800 Product Reference Guide
Spain/Espaa
Symbol Technologies S.L.
Avenida de Bruselas, 22
Edificio Sauce
Alcobendas, Madrid 28108
Spain
91 324 40 00 (Inside Spain)
+34 91 324 40 00 (Outside Spain)
Fax: +34.91.324.4010
Sweden/Sverige
Letter address:
Symbol Technologies AB
Box 1354
S-171 26 SOLNA
Sweden
Visit/shipping address:
Symbol Technologies AB
Solna Strandvg 78
S-171 54 SOLNA
Sweden
xvi
About This Manual
xvii
LS 5700/LS 5800 Product Reference Guide
xviii
Chapter 1 The LS 5700/5800
Scanner
LS 5700 LS 5800
1-1
LS 5700/LS 5800 Product Reference Guide
1-2
Chapter 2 Set Up
Unpacking
Remove the scanner from its packing and inspect it for
damage. Figure 2-1 shows the items which should be
included with the shipment:
Scanner
Power supply or power cable (if applicable)
RS-232C Host interface cable, or Synapse Adapter
cable and Synapse cable
Quick Reference Guide
Cables
Synapse
LS 5700 / LS 5800 Synapse Adapter
Power Supply
Synapse Power Adapter
Quick Reference RS-232
Guide
Power
Supply
2-1
LS 5700/LS 5800 Product Reference Guide
Input/Output Ports
The scanner contains the ports as shown in Figure 2-2.
2-2
Set Up
2-3
LS 5700/LS 5800 Product Reference Guide
IBM 468x/469x
LS 5700/ Port 9E, 17
LS 5800
Synapse Cable
Synapse Cable
Regulatory Y-Cable
p/n 25-17086-01
2-4
Set Up
Synapse
Adapter Cable
p/n 25-17072-01 Host
LS 5700/ Terminal
LS 5800
Synapse Cable
Power
2-5
LS 5700/LS 5800 Product Reference Guide
RS-232
LS 5700/ Host
LS 5800
Power
2-6
Set Up
Dual-Port RS-232C
Attach the Synapse adapter cable to the Host port on the
scanner. Attach the appropriate Synapse cable to the
adapter cable, the host terminal, and auxiliary RS-232C
device. Attach the power supply to the Power port. If
additional scanning versatility is desired, plug a Synapse-
compatible scanner into the Hand-Held Laser Scanner port
(Figure 2-6).
RS-232
Synapse Host
Adapter Cable Terminal
p/n 25-17072-01
LS 5700/
LS 5800
Synapse Cable
Auxiliary
Power RS-232
Device
2-7
LS 5700/LS 5800 Product Reference Guide
2-8
Set Up
2-9
LS 5700/LS 5800 Product Reference Guide
2-10
Set Up
EAS Options
EAS is available with either an internal antenna, or an
external antenna kit. Various configurations are shown in
Table 2-1.
2-11
LS 5700/LS 5800 Product Reference Guide
Mounting
LS 5700
The LS 5700 is designed to rest on top of the counter. The
dotted area in Figure 2-7 represents the active scan area, or
the area in which a bar code is decoded.
Screws
2-12
Set Up
2. Place the front of the scanner under the front lip of the
stand (Figure 2-9).
2-13
LS 5700/LS 5800 Product Reference Guide
Mounting
LS 5800
The LS 5800 mounts in the counter, with the face of the
scanner either flush with the counter top or resting on it.
The dotted area in Figure 2-11 depicts the active scan area,
and the arrow shows the optimal direction of product
flow. The scanners active scan zone extends about 6 in.
(15.24 cm) above the window, and is angled at
approximately 38 from the counter.
Product Flow
symbol
2-14
Set Up
Layout
Figure 2-12 shows a typical LS 5800 installation. For best
operating results, locate the power supply at least 4 in.
(10.16 cm) below the scanner chassis or 2 in. (5.08 cm) away
laterally.
Host
I/F Cable
Scanner
~66.5 in.
1690 mm
Synapse Cable
1810 mm
~71.2 in.
Power Supply
Cable Routing
Figure 2-12. Typical LS 5800 Installation
2-15
LS 5700/LS 5800 Product Reference Guide
7.91 in.
201 mm
~3.5 in.
89 mm
2-16
Set Up
2. Route the cables from beneath the hole and attach to the
scanner as shown in Figure 2-12.
3. Lower the scanner into the counter hole.
Option B- Flush with the counter top
1. On the counter top, measure two concentric squares: an
inside square of 6.81 in. (173 mm), and an outside square
of 7.91 in. (201 mm) (Figure 2-14)
2. Cut out the 6.81 in. (173 mm) inner square.
3. With a router set to the appropriate depth, route out the
outside square. The corner radius should not exceed
0.20 in. (5 mm).
- LS-5800-I210DN: depth = 0.05in. (1.2mm)
- LS-5800-I210SN: depth = 0.05in. (1.2mm)
2-17
LS 5700/LS 5800 Product Reference Guide
6.8 mm
0.05 in
0.27 in
201 mm 201 mm
10 mm min
0.39 in min
0.39 in min
89 mm 89 mm
LS-5800-I210DN LS-5800-I210SC
LS-5800-I210SN
Figure 2-14. Stainless Steel Top Option B
4. Route the cables from beneath the hole and attach to the
scanner as shown in Figure 2-12.
5. Lower the scanner into the counter hole.
Replacing Other Symbol Fixed-Mount Scanners
(LS 5100/LS 5400) with LS 5800-I220SN
1. Remove the LS 5100/LS 5400 scanner.
2. Place the LS 5800-IxxxZN or LS 5800-I220SN scanner on
the counter near the hole.
3. Route the cables from beneath the hole and attach to the
scanner as shown in Figure 2-12.
2-18
Set Up
7.5 in.
191 mm
4.63 in.
118 mm
2-19
LS 5700/LS 5800 Product Reference Guide
Beeper
The scanner has an internal beeper to signal a good decode
or provide other information (see Beeper Definitions
beginning on page 4-8). An external beeper can also be
connected to the RS-232C port. Either or both of these
beepers can be enabled or disabled through the use of bar
code menus.
LS 5700 Controls
See Figure 2-16 on the following page. The LS 5700 has a
push button near the top right corner. This push button is
to adjust both the volume and tone of the beeper, and to
wake the scanner from its Rest or Sleep mode.
When the scanner is operating, depress this button to adjust
the volume/tone. Hold down the button until the desired
sound is obtained. There are five distinct volume/tone
combinations. Each combination beeps two times before
cycling to the next sound. When you hear the volume/tone
combination you want, immediately release the button.
If the scanner is in a Rest or Sleep mode, depressing this
push button briefly will awaken the scanner.
2-20
Set Up
Speaker
Volume Control
&
Wake Up Switch
Decode
Indicator
2-21
LS 5700/LS 5800 Product Reference Guide
LS 5700 Connectors
Removing the connector cover will allow access to the
scanners connectors (Figure 2-17).
EAS Antenna
(Optional)
Power
Host Port
Scanner Port
RS-232C Port
Connector Cover
2-22
Chapter 3 Scanning
symbol
3-1
LS 5700/LS 5800 Product Reference Guide
Rest/Sleep Mode
If there is no scanning activity for a specified period of time,
the scanner enters a Rest, or reduced power mode. The
default time of 30 minutes can be changed by scanning the
appropriate bar code in Chapter 5. This mode saves power
and extends the life of the scanner. The scanner
automatically awakens as soon as you pass a bar coded
item in front of the scan window.
3-2
Scanning
What If...
Nothing happens when you follow the operating
instructions.
You Should
Check that the scanner is plugged into an AC outlet.
Ensure that the power supply DC output is connected
firmly to the scanner.
Make sure the scanner is connected to the point-of-
sale register.
Be sure that youve scanned a host type.
Check for loose cable connections.
Make certain the code type youre trying to decode is
enabled, and that it is supported by your host.
Check the symbol to make sure it is of suitable quality
(not damaged).
Try scanning similar symbols of the same code type.
Be sure youre using the proper power supply.
Note: If after performing these checks
the symbol still does not scan,
contact your distributor or call
the Symbol Support Center. See
page xi for the telephone number.
3-3
LS 5700/LS 5800 Product Reference Guide
Programming
You can custom tailor the performance and operation of the
scanner with a series of bar codes. Refer to the Default Table
beginning on page 5-6 for a list of the factory-
programmed defaults. A table of Beeper Definitions
applicable to programming is located on page 4-8.
3-4
Scanning
Setting Parameters
If the default values suit your requirements, all you
need to do is scan a Host Type. See Table 5-1on page 5-6.
Parameters other than default values can be set by
scanning appropriate bar codes.
Host Types
To communicate properly with your host terminal, a Host
Type must be selected. If you are using a Synapse Smart
Cable, a programming sheet containing a host bar code is
packaged with the cable. Select your host type using that
bar code.
RS-232C Port Options
Serial RS-232C data can be modified to meet host
requirements.
Code Types & Options
Enable or disable host-supported code types and options
such as UPC or EAN supplementals and selectable code
lengths.
Custom Tailoring
Customize any combination of the following parameters to
suit your specific environment or application requirements.
Scanning Range
Beeper Volume
Beeper Tone
3-5
LS 5700/LS 5800 Product Reference Guide
Decode Options
Reject Predecode Block. Added security against
accidental misdecodes caused by an operator
bringing similar but not identical items into the
scanners field of view simultaneously. When enabled,
the scanner rejects a bar code which contains a block
similar to the last decoded bar code.
Accept Predecode Block. Allows the scanner to
decode any bar code regardless of the item last
decoded.
Security Levels. Provides increasing levels of
security against misdecoding out of spec bar codes.
Increasing levels of security adversely affect the
aggressiveness of the scanner.
3-6
Scanning
Programming Utilities
This section contains numeric bar codes used to quantify
certain options, application specific bar codes, Enter and
Cancel bar codes.
3-7
LS 5700/LS 5800 Product Reference Guide
3-8
Chapter 4 Maintenance and
Specifications
Routine Maintenance
Cleaning the exit window is the only maintenance required.
A dirty or scratched window may affect scanning activity.
Remove any dirt particles with a damp cloth.
Wipe the window with a tissue moistened with
ammonia/water.
LS 5700
To change or clean the exit window:
Press window removal latch and rotate forward
(Figure 4-1).
Window Removal
Latch
To Clean:
Wipe clean the underside of the upper window.
Wipe clean the top surface of the lower window.
Re-install the window by snapping into place.
4-1
LS 5700/LS 5800 Product Reference Guide
LS 5800
To change or clean the exit window:
To Clean:
Wipe clean the underside of the upper window.
Wipe clean the top surface of the lower window.
Re-install the top cover by tightening the two large
screws.
4-2
Maintenance and Spcifications
Lift Straps
Accessories
The following accessories are available from Symbol
Technologies. See your Symbol representative or re-seller
for ordering information.
LS 5700 Mounting Stand
LS 5800 In-counter Mounting Kit
LS 5800 Stainless steel top plate with various
hardened window options
LS 5700/LS 5800 External Beeper
Competitive Scanner Adapter Kit*
EAS Antenna kit
- Pre-loaded on some models
- Add-on kit for either model
4-3
LS 5700/LS 5800 Product Reference Guide
Technical Specifications
Table 4-1. Technical Specifications
Item Description
Scanner System
LS 5700 16-line, 4-direction dynamic cross
pattern
LS 5800 18-line, 6-direction dynamic cross
pattern
Angular Orientation
Yaw -45 to +45
Roll 360
Pitch
LS 5700 -30 to +60
LS 5800 0 to 90
4-4
Maintenance and Spcifications
Item Description
Weight
LS 5700 1.9 lbs .86 kg
LS 5800 1.8 lbs .81 kg
Dimensions
LS 5700
Depth 3.82 in. 9.7 cm
Height 6.2 in. 15.7 cm
Width 5.97 in. 15.2 cm
LS 5800 See Table 4-3
LS 5700 LS 5800
Full Range 10 in. 6.7 in.
25.4 cm 17.0 cm
Medium Range 7.0 in. 6.0 in.
17.8 cm 15.2 cm
Short Range 3.5 in. 3.5 in.
8.9 cm 8.9 cm
Decode range depends on contrast, density, orientation, and
quality of the bar code being decoded.
4-5
LS 5700/LS 5800 Product Reference Guide
4-6
Maintenance and Spcifications
4-7
LS 5700/LS 5800 Product Reference Guide
Beeper Definitions
Table 4-5. Beeper Definitions
Standard Use
4-8
Maintenance and Spcifications
Serial Communication
4-9
LS 5700/LS 5800 Product Reference Guide
4-10
Chapter 5 Parameter Menus
5-1
LS 5700/LS 5800 Product Reference Guide
5-2
Parameter Menus
5-3
LS 5700/LS 5800 Product Reference Guide
5-4
Parameter Menus
5-5
LS 5700/LS 5800 Product Reference Guide
Default Table
Table 5-1. Default Table
5-6
Parameter Menus
5-7
LS 5700/LS 5800 Product Reference Guide
5-8
Parameter Menus
5-9
LS 5700/LS 5800 Product Reference Guide
5-10
Parameter Menus
EAS Interlock
Enable EAS Interlock
When enabled, the EAS tag is not de-activated until the
associated bar code is decoded.
5-11
LS 5700/LS 5800 Product Reference Guide
EAS Interlock
Disable EAS Interlock
When disabled (default), the EAS tag is de-activated
independently of any bar code scanning.
5-12
Parameter Menus
5-13
LS 5700/LS 5800 Product Reference Guide
NO HOST
5-14
Parameter Menus
5-15
LS 5700/LS 5800 Product Reference Guide
5-16
Parameter Menus
5-17
LS 5700/LS 5800 Product Reference Guide
5-18
Parameter Menus
5-19
LS 5700/LS 5800 Product Reference Guide
5-20
Parameter Menus
5-21
LS 5700/LS 5800 Product Reference Guide
5-22
Parameter Menus
5-23
LS 5700/LS 5800 Product Reference Guide
5-24
Parameter Menus
5-25
LS 5700/LS 5800 Product Reference Guide
5-26
Parameter Menus
5-27
LS 5700/LS 5800 Product Reference Guide
ODD
5-28
Parameter Menus
EVEN
5-29
LS 5700/LS 5800 Product Reference Guide
MARK
5-30
Parameter Menus
SPACE
5-31
LS 5700/LS 5800 Product Reference Guide
NONE
5-32
Parameter Menus
CHECK PARITY
5-33
LS 5700/LS 5800 Product Reference Guide
5-34
Parameter Menus
5-35
LS 5700/LS 5800 Product Reference Guide
5-36
Parameter Menus
NONE
5-37
LS 5700/LS 5800 Product Reference Guide
STANDARD RTS/CTS
5-38
Parameter Menus
RTS/CTS OPTION 1
5-39
LS 5700/LS 5800 Product Reference Guide
RTS/CTS OPTION 2
5-40
Parameter Menus
RTS/CTS OPTION 3
5-41
LS 5700/LS 5800 Product Reference Guide
NONE
5-42
Parameter Menus
ACK/NAK
5-43
LS 5700/LS 5800 Product Reference Guide
ENQ
5-44
Parameter Menus
5-45
LS 5700/LS 5800 Product Reference Guide
XON/XOFF
5-46
Parameter Menus
5-47
LS 5700/LS 5800 Product Reference Guide
1 STOP BIT
5-48
Parameter Menus
2 STOP BITS
5-49
LS 5700/LS 5800 Product Reference Guide
7-BIT
5-50
Parameter Menus
8-BIT
5-51
LS 5700/LS 5800 Product Reference Guide
5-52
Parameter Menus
5-53
LS 5700/LS 5800 Product Reference Guide
5-54
Parameter Menus
5-55
LS 5700/LS 5800 Product Reference Guide
5-56
Parameter Menus
5-57
LS 5700/LS 5800 Product Reference Guide
5-58
Parameter Menus
5-59
LS 5700/LS 5800 Product Reference Guide
5-60
Parameter Menus
5-61
LS 5700/LS 5800 Product Reference Guide
5-62
Parameter Menus
5-63
LS 5700/LS 5800 Product Reference Guide
5-64
Parameter Menus
ODD
5-65
LS 5700/LS 5800 Product Reference Guide
EVEN
5-66
Parameter Menus
MARK
5-67
LS 5700/LS 5800 Product Reference Guide
SPACE
5-68
Parameter Menus
NONE
5-69
LS 5700/LS 5800 Product Reference Guide
CHECK PARITY
5-70
Parameter Menus
5-71
LS 5700/LS 5800 Product Reference Guide
5-72
Parameter Menus
5-73
LS 5700/LS 5800 Product Reference Guide
NONE
5-74
Parameter Menus
STANDARD RTS/CTS
5-75
LS 5700/LS 5800 Product Reference Guide
NONE
5-76
Parameter Menus
XON/XOFF
5-77
LS 5700/LS 5800 Product Reference Guide
5-78
Parameter Menus
1 STOP BIT
5-79
LS 5700/LS 5800 Product Reference Guide
2 STOP BITS
5-80
Parameter Menus
7-BIT
5-81
LS 5700/LS 5800 Product Reference Guide
8-BIT
5-82
Parameter Menus
5-83
LS 5700/LS 5800 Product Reference Guide
5-84
Parameter Menus
5-85
LS 5700/LS 5800 Product Reference Guide
5-86
Parameter Menus
5-87
LS 5700/LS 5800 Product Reference Guide
5-88
Parameter Menus
5-89
LS 5700/LS 5800 Product Reference Guide
5-90
Parameter Menus
5-91
LS 5700/LS 5800 Product Reference Guide
ENABLE UPC-A
5-92
Parameter Menus
DISABLE UPC-A
5-93
LS 5700/LS 5800 Product Reference Guide
ENABLE UPC-E
5-94
Parameter Menus
DISABLE UPC-E
5-95
LS 5700/LS 5800 Product Reference Guide
ENABLE EAN-8
5-96
Parameter Menus
DISABLE EAN-8
5-97
LS 5700/LS 5800 Product Reference Guide
ENABLE EAN-13
5-98
Parameter Menus
DISABLE EAN-13
5-99
LS 5700/LS 5800 Product Reference Guide
5-100
Parameter Menus
5-101
LS 5700/LS 5800 Product Reference Guide
5-102
Parameter Menus
5-103
LS 5700/LS 5800 Product Reference Guide
5-104
Parameter Menus
5-105
LS 5700/LS 5800 Product Reference Guide
5-106
Parameter Menus
5-107
LS 5700/LS 5800 Product Reference Guide
5-108
Parameter Menus
5-109
LS 5700/LS 5800 Product Reference Guide
5-110
Parameter Menus
5-111
LS 5700/LS 5800 Product Reference Guide
ENABLE UCC/EAN-128
5-112
Parameter Menus
DISABLE UCC/EAN-128
5-113
LS 5700/LS 5800 Product Reference Guide
5-114
Parameter Menus
ENABLE CODE 39
5-115
LS 5700/LS 5800 Product Reference Guide
DISABLE CODE 39
5-116
Parameter Menus
5-117
LS 5700/LS 5800 Product Reference Guide
5-118
Parameter Menus
5-119
LS 5700/LS 5800 Product Reference Guide
5-120
Parameter Menus
5-121
LS 5700/LS 5800 Product Reference Guide
5-122
Parameter Menus
5-123
LS 5700/LS 5800 Product Reference Guide
5-124
Parameter Menus
5-125
LS 5700/LS 5800 Product Reference Guide
ENABLE I 2 OF 5
5-126
Parameter Menus
DISABLE I 2 OF 5
5-127
LS 5700/LS 5800 Product Reference Guide
5-128
Parameter Menus
5-129
LS 5700/LS 5800 Product Reference Guide
5-130
Parameter Menus
I 2 of 5 ANY LENGTH
5-131
LS 5700/LS 5800 Product Reference Guide
5-132
Parameter Menus
5-133
LS 5700/LS 5800 Product Reference Guide
5-134
Parameter Menus
ENABLE CODABAR
5-135
LS 5700/LS 5800 Product Reference Guide
DISABLE CODABAR
5-136
Parameter Menus
5-137
LS 5700/LS 5800 Product Reference Guide
5-138
Parameter Menus
5-139
LS 5700/LS 5800 Product Reference Guide
5-140
Parameter Menus
5-141
LS 5700/LS 5800 Product Reference Guide
5-142
Parameter Menus
5-143
LS 5700/LS 5800 Product Reference Guide
5-144
Parameter Menus
Custom Tailoring
Scanning Range
Select the decode range that best suits your scanning needs.
FULL RANGE covers the maximum scanning range, and is
recommended for in-counter applications and installations
where there is no opportunity for inadvertent reads.
FULL RANGE
5-145
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Scanning Range
MEDIUM RANGE is recommended for on-counter
applications and installations where full range may allow
inadvertent reads.
MEDIUM RANGE
5-146
Parameter Menus
Custom Tailoring
Scanning Range
SHORT RANGE is recommended for on-counter
applications where counter space is at a minimum.
SHORT RANGE
5-147
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Internal Beeper
This parameter connects the beeper signal to the internal
beeper.
5-148
Parameter Menus
Custom Tailoring
Disable Internal Beeper
This parameter disconnects the beeper signal to the internal
beeper.
5-149
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
RS-232C Port External Beeper
This parameter connects the beeper signal to the RS-232C
Port.
5-150
Parameter Menus
Custom Tailoring
Disable RS-232C Port External Beeper
This parameter disconnects the beeper signal to the
RS-232C Port.
5-151
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Beeper Volume
Select the beeper volume that best suits your operation.
LOW VOLUME
5-152
Parameter Menus
Custom Tailoring
Beeper Volume
MEDIUM VOLUME
5-153
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Beeper Volume
HIGH VOLUME
5-154
Parameter Menus
Custom Tailoring
Beeper Frequency
To select a decode beep frequency (tone), scan the LOW
FREQUENCY, MEDIUM FREQUENCY, or HIGH
FREQUENCY bar code.
LOW FREQUENCY
5-155
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Beeper Frequency
MEDIUM FREQUENCY
5-156
Parameter Menus
Custom Tailoring
Beeper Frequency
HIGH FREQUENCY
5-157
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Time-out Between Decodes, Same Symbol
This parameter sets the minimum time between decodes
of the same symbol. It is programmable in 0.1 second
increments from 0.0 to 9.9 seconds. (Setting this above 0.4
seconds is recommended.)
Scan the bar code below to select a new time-out. Next scan
two numeric bar codes on pages 5-246 to 5-255, the first
representing seconds, the second tenths of seconds. If you
make an error, or wish to change your selection, scan
CANCEL on page 5-256.
5-158
Parameter Menus
Custom Tailoring
Time-out Between Decodes, Different Symbols
This parameter sets the minimum time between decodes
of different symbols. It is programmable in 0.1 second
increments from 0.0 to 9.9 seconds.
Scan the bar code below to select a new time-out. Next scan
two numeric bar codes on pages 5-246 to 5-255, the first
representing seconds, the second tenths of seconds. If you
make an error, or wish to change your selection, scan
CANCEL on page 5-256.
5-159
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Decode Buffering
When enabled, successive decodes are buffered by the
scanner. This is useful when the host takes a long time to
receive and/or process a symbol.
5-160
Parameter Menus
Custom Tailoring
Disable Decode Buffering
When disabled, successive decodes are no longer buffered
by the scanner. The scanner waits until a decoded symbol is
transmitted to the host device before processing another
symbol.
5-161
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Rest Mode
To choose a Rest Mode for the LS 5700/LS 5800, scan the bar
code below. The default time is 30 minutes. That is, 30
minutes after a scan attempt, the scanner enters this mode.
To change the time to rest mode, scan a bar code beginning
on page 5-164.
REST MODE
5-162
Parameter Menus
Custom Tailoring
Sleep Mode
The LS 5700 can be programmed to completely shut
down. The default time is 30 minutes. That is, 30 minutes
after a scan attempt, the scanner enters this mode. To
change the time to sleep mode, scan a bar code beginning
on page 5-164.
SLEEP MODE
5-163
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Time Delay to Rest/Sleep Mode
This parameter sets the time the scanner remains active
after any scanning activity. Scan one of the four options.
Depending on the selection, the scanner enters a rest/sleep
mode 15, 30, 60, or 90 minutes after the last attempted
decode.
If you make a mistake, scan CANCEL on page 5-256.
15 MINUTES
5-164
Parameter Menus
Custom Tailoring
Time Delay to Rest/Sleep Mode
30 MINUTES
5-165
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Time Delay to Rest/Sleep Mode
60 MINUTES
5-166
Parameter Menus
Custom Tailoring
Time Delay to Rest/Sleep Mode
90 MINUTES
5-167
LS 5700/LS 5800 Product Reference Guide
Custom Tailoring
Primary Decode Session Time
This parameter sets the maximum time decode processing
continues during a scan attempt. It is programmable in 0.1
second increments from 0.1 to 9.9 seconds. (Setting this
between 1.0 and 3.0 seconds is recommended.)
Scan the bar code below to select a new time-out. Next scan
two numeric bar codes on pages 5-246 to 5-255, the first
representing seconds, the second tenths of seconds. If you
make an error, or wish to change your selection, scan
CANCEL on page 5-256.
5-168
Parameter Menus
Decode Options
UPC/EAN Predecode Block
UPC/EAN bar codes are made up of two blocks
representing left and right halves. For example, bar
code1234567890 is divided into left block 12345, and right
block 67890.
5-169
LS 5700/LS 5800 Product Reference Guide
Decode Options
Reject Predecode Block
This option provides additional protection (beyond the
embedded check digit) against mis-splicing a UPC/EAN
block from a symbol that has just been decoded (but has not
completely exited the scanners field of view), with a block
from a new symbol that has just been presented to the
scanner.
This option requires the scanner to compare the new
symbol against the symbol just decoded to see if there are
common blocks.
If either the left or right blocks match between symbols,
the scanner rejects the common block for the period of time
dictated by the TIME OUT BETWEEN DECODES - SAME
SYMBOL parameter.
5-170
Parameter Menus
Decode Options
Accept Predecode Block
This option allows immediate decode of a new UPC/EAN
bar code regardless of the previously decoded UPC/EAN
bar codes block content.
5-171
LS 5700/LS 5800 Product Reference Guide
Decode Options
UPC/EAN Security Level
The LS 5700/LS 5800 offers four levels of decode security
for UPC/EAN bar codes. Increasing levels of security are
provided for decreasing levels of bar code quality. There is
an inverse relationship between security and scanner
aggressiveness, so be sure to choose only that level of
security necessary for any given application.
Level 0
This is the default setting which allows the scanner to
operate in its most aggressive state, while providing
sufficient security in decoding in-spec UPC/EAN bar
codes.
5-172
Parameter Menus
Decode Options
UPC/EAN Security Level
Level 1
As bar code quality levels diminish, certain characters
become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If
you are experiencing mis-decodes of poorly printed bar
codes, and the mis-decodes are limited to these characters,
select this security level.
5-173
LS 5700/LS 5800 Product Reference Guide
Decode Options
UPC/EAN Security Level
Level 2
If you are experiencing mis-decodes of poorly printed bar
codes, and the mis-decodes are not limited to characters 1,
2, 7, and 8, select this security level.
5-174
Parameter Menus
Decode Options
UPC/EAN Security Level
Level 3
If you have tried Security Level 2, and are still experiencing
misdecodes, select this security level. Be advised, selecting
this option is an extreme measure against mis-decoding
severely out of spec bar codes. Selection of this level
significantly impairs the decoding ability of the scanner. If
this level of security is necessary, you should try to improve
the quality of your bar codes.
5-175
LS 5700/LS 5800 Product Reference Guide
Decode Options
Linear UPC/EAN Decode
This option applies to code types containing two adjacent
blocks (e.g. UPC-A, EAN-8, EAN-13). When enabled, a bar
code is transmitted only when both the left and right blocks
are successfully decoded within one laser scan. This option
should be enabled when bar codes are in proximity to each
other.
5-176
Parameter Menus
Decode Options
Disable Linear UPC/EAN Decode
5-177
LS 5700/LS 5800 Product Reference Guide
Decode Options
Linear Supplemental Decode
This option applies to code types containing two or five
character supplementals. When enabled, a bar code is
transmitted only when both the supplemental block and its
adjacent block are successfully decoded within one laser
scan. This option should be enabled when bar codes are in
proximity to each other.
5-178
Parameter Menus
Decode Options
Disable Linear Supplemental Decode
5-179
LS 5700/LS 5800 Product Reference Guide
Decode Options
Decode Redundancy for UPC/EAN
(only in Autodiscriminate Mode)
With Autodiscriminate UPC/EAN Supplementals
selected, this option adjusts the number of times a symbol
is decoded before transmission. The range is from two to
thirty times. Ten or above is recommended when decoding
a mix of UPC/EAN symbols with and without
supplementals.
Scan the bar code below to select a decode redundancy
value. Next scan two numeric bar codes on pages 5-246
to 5-255 that represent the desired number of times. For
single digit numbers, include a leading zero. If you make
an error, or wish to change your selection, scan CANCEL
on page 5-256.
5-180
Parameter Menus
Decode Options
UPC/EAN Decode Performance
This option offers three levels of decode performance
or aggressiveness for UPC/EAN symbols without
supplementals. Increasing the performance level reduces
the amount of required bar code orientation, which is useful
if you are scanning very long and/or truncated bar codes.
Increased levels reduce decode security.
If you enable this option, you may select a Decode
Performance level from the following pages to suit your
performance needs.
5-181
LS 5700/LS 5800 Product Reference Guide
Decode Options
Disable UPC/EAN Decode Performance
5-182
Parameter Menus
Decode Options
UPC/EAN Decode Performance
Level 1
5-183
LS 5700/LS 5800 Product Reference Guide
Decode Options
UPC/EAN Decode Performance
Level 2
5-184
Parameter Menus
Decode Options
UPC/EAN Decode Performance
Level 3
5-185
LS 5700/LS 5800 Product Reference Guide
Decode Options
Linear Code Type Security
Level 1
The LS 5700/LS 5800 offers four levels of decode security
for linear code types (e.g. Code 39, Interleaved 2 of 5).
Higher security levels are selected for decreasing levels of
bar code quality. As security levels increase, the scanners
aggressiveness decreases.
5-186
Parameter Menus
Decode Options
Linear Code Type Security
Level 2
5-187
LS 5700/LS 5800 Product Reference Guide
Decode Options
Linear Code Type Security
Level 3
5-188
Parameter Menus
Decode Options
Linear Code Type Security
Level 4
5-189
LS 5700/LS 5800 Product Reference Guide
Decode Options
Code 128 Decode Performance
This option offers three levels of decode performance or
aggressiveness for Code 128 symbols. Increasing the
performance level reduces the amount of required bar code
orientation, which is useful if you are scanning very long
and/or truncated bar codes. Increased levels reduce
decode security.
If you enable this option, you may select a Decode
Performance level from the following pages to suit your
performance needs.
5-190
Parameter Menus
Decode Options
Disable Code 128 Decode Performance
5-191
LS 5700/LS 5800 Product Reference Guide
Decode Options
Code 128 Decode Performance
Level 1
5-192
Parameter Menus
Decode Options
Code 128 Decode Performance
Level 2
5-193
LS 5700/LS 5800 Product Reference Guide
Decode Options
Code 128 Decode Performance
Level 3
5-194
Parameter Menus
Decode Options
Code 39 Decode Performance
This option offers three levels of decode performance or
aggressiveness for Code 39 symbols. Increasing the
performance level reduces the amount of required bar code
orientation, which is useful if you are scanning very long
and/or truncated bar codes. Increased levels reduce decode
security.
If you enable this option, you may select a Decode
Performance level from the following pages to suit your
performance needs.
5-195
LS 5700/LS 5800 Product Reference Guide
Decode Options
Disable Code 39 Decode Performance
5-196
Parameter Menus
Decode Options
Code 39 Decode Performance
Level 1
5-197
LS 5700/LS 5800 Product Reference Guide
Decode Options
Code 39 Decode Performance
Level 2
5-198
Parameter Menus
Decode Options
Code 39 Decode Performance
Level 3
5-199
LS 5700/LS 5800 Product Reference Guide
TRANSMIT
UPC-A CHECK DIGIT
5-200
Parameter Menus
DO NOT TRANSMIT
UPC-A CHECK DIGIT
5-201
LS 5700/LS 5800 Product Reference Guide
TRANSMIT
UPC-E CHECK DIGIT
5-202
Parameter Menus
DO NOT TRANSMIT
UPC-E CHECK DIGIT
5-203
LS 5700/LS 5800 Product Reference Guide
NO PREAMBLE
(<DATA>)
5-204
Parameter Menus
SYSTEM CHARACTER
(<SYSTEM CHARACTER> <DATA>)
5-205
LS 5700/LS 5800 Product Reference Guide
5-206
Parameter Menus
NO PREAMBLE
(<DATA>)
5-207
LS 5700/LS 5800 Product Reference Guide
SYSTEM CHARACTER
(<SYSTEM CHARACTER> <DATA>)
5-208
Parameter Menus
5-209
LS 5700/LS 5800 Product Reference Guide
5-210
Parameter Menus
5-211
LS 5700/LS 5800 Product Reference Guide
5-212
Parameter Menus
5-213
LS 5700/LS 5800 Product Reference Guide
TYPE IS EAN-13
5-214
Parameter Menus
TYPE IS EAN-8
5-215
LS 5700/LS 5800 Product Reference Guide
CONVERT I 2 of 5 to EAN-13
(ENABLE)
5-216
Parameter Menus
5-217
LS 5700/LS 5800 Product Reference Guide
5-218
Parameter Menus
5-219
LS 5700/LS 5800 Product Reference Guide
5-220
Parameter Menus
5-221
LS 5700/LS 5800 Product Reference Guide
5-222
Parameter Menus
5-223
LS 5700/LS 5800 Product Reference Guide
INTERCHARACTER DELAY
5-224
Parameter Menus
5-225
LS 5700/LS 5800 Product Reference Guide
5-226
Parameter Menus
5-227
LS 5700/LS 5800 Product Reference Guide
PAUSE DURATION
5-228
Parameter Menus
SCAN PREFIX
5-229
LS 5700/LS 5800 Product Reference Guide
SCAN SUFFIX
5-230
Parameter Menus
SERIAL PREFIX
5-231
LS 5700/LS 5800 Product Reference Guide
SERIAL SUFFIX
5-232
Parameter Menus
SCAN OPTIONS
5-233
LS 5700/LS 5800 Product Reference Guide
DATA AS IS
5-234
Parameter Menus
5-235
LS 5700/LS 5800 Product Reference Guide
<PREFIX> <DATA>
5-236
Parameter Menus
5-237
LS 5700/LS 5800 Product Reference Guide
SERIAL OPTIONS
5-238
Parameter Menus
DATA AS IS
5-239
LS 5700/LS 5800 Product Reference Guide
<DATA> <SUFFIX>
5-240
Parameter Menus
5-241
LS 5700/LS 5800 Product Reference Guide
5-242
Parameter Menus
ENABLE
IGNORE UNKNOWN CHARACTERS
5-243
LS 5700/LS 5800 Product Reference Guide
DISABLE
IGNORE UNKNOWN CHARACTERS
5-244
Parameter Menus
5-245
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Numeric Bar Codes
For parameters requiring specific numeric values, scan the
appropriately numbered bar code(s).
5-246
Parameter Menus
Programming Utilities
Numeric Bar Codes
5-247
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Numeric Bar Codes
5-248
Parameter Menus
Programming Utilities
Numeric Bar Codes
5-249
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Numeric Bar Codes
5-250
Parameter Menus
Programming Utilities
Numeric Bar Codes
5-251
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Numeric Bar Codes
5-252
Parameter Menus
Programming Utilities
Numeric Bar Codes
5-253
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Numeric Bar Codes
5-254
Parameter Menus
Programming Utilities
Numeric Bar Codes
5-255
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Cancel
If you make an error, or wish to change your selection, scan
CANCEL, below.
CANCEL
5-256
Parameter Menus
Programming Utilities
Enter
When an ENTER is required, such as for DATA
TRANSMISSION FORMATS, scan the bar code below.
ENTER
5-257
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 1
ENABLE
5-258
Parameter Menus
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 1
DISABLE
5-259
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 2
ENABLE
5-260
Parameter Menus
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 2
DISABLE
5-261
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 3
ENABLE
5-262
Parameter Menus
Programming Utilities
Applications Items
Reserved for future use.
APPLICATIONS ITEM 3
DISABLE
5-263
LS 5700/LS 5800 Product Reference Guide
Programming Utilities
Applications Items
Reserved for future use.
Enter a 3 digit value from 0 to 255.
APPLICATIONS VALUE
5-264
Appendix
UCC/EAN-128
UCC/EAN-128 is a convention for printing data fields with
standard Code 128 bar code symbols. UCC/EAN-128
symbols are distinguished by a leading FNC 1 character as
the first or second character in the symbol. Other FNC 1
characters are used to delineate fields.
A-1
LS 5700/LS 5800 Product Reference Guide
A-2
Appendix
A Code 39
C Code 128
E UPC/EAN
F Codabar
I Interleaved 2 of 5
X Bookland EAN
A-3
LS 5700/LS 5800 Product Reference Guide
A-4
Appendix
A-5
LS 5700/LS 5800 Product Reference Guide
A-6
Appendix
A-7
LS 5700/LS 5800 Product Reference Guide
A-8
Appendix
A-9
LS 5700/LS 5800 Product Reference Guide
A-10
Appendix
A-11
LS 5700/LS 5800 Product Reference Guide
A-12
Appendix
A-13
LS 5700/LS 5800 Product Reference Guide
A-14
Index
A
accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
AIM code identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
ASCII values . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7A-14
auxiliary options
RS-232C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-56
B
bar codes, scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
beeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
beeper definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
bullets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
C
code types & options . . . . . . . . . . . . . . . . . . . . . . 3-5, 5-92
Bookland-EAN . . . . . . . . . . . . . . . . . . . . . . . . . 5-100
codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-135
code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-110
code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-115
code 39 check digit verification . . . . . . . . . . . . . 5-124
code 39 full ASCII . . . . . . . . . . . . . . . . . . . . . . . 5-117
EAN-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-98
EAN-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-96
interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . 5-126
interleaved 2 of 5 check digit verification
OPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-133
USS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-132
lengths
CLSI editing . . . . . . . . . . . . . . . . . . . . . . . . 5-141
codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-137
Index-i
LS 5700/LS 5800 Product Reference Guide
Index-ii
Index
D
data transmission format . . . . . . . . . . . . . . . . . . . . . . . 3-7
beep after good decode . . . . . . . . . . . . . . . . . . 5-222
convert EAN-8 to EAN-13 type . . . . . . . . . . . . . 5-214
convert I 2 of 5 to EAN-13 . . . . . . . . . . . . . . . . . 5-216
convert UPC-E to UPC-A . . . . . . . . . . . . . . . . . 5-210
data format cancel . . . . . . . . . . . . . . . . . . . . . . 5-245
EAN zero extend . . . . . . . . . . . . . . . . . . . . . . . . 5-212
ignore unknown characters . . . . . . . . . . . . . . . . 5-243
intercharacter delay . . . . . . . . . . . . . . . . . . . . . . 5-224
pause duration . . . . . . . . . . . . . . . . . . . . . . . . . 5-228
prefix/suffix values . . . . . . . . . . . . . . . . . . . . . . . 5-229
scan data transmission format . . . . . . . . . . . . . 5-233
serial data transmission format . . . . . . . . . . . . . 5-238
transmit code 39 check digit . . . . . . . . . . . . . . . 5-220
transmit code ID character . . . . . . . . . . . . . . . . 5-225
transmit I 2 of 5 check digit . . . . . . . . . . . . . . . . 5-218
transmit UPC-A check digit . . . . . . . . . . . . . . . . 5-200
transmit UPC-E check digit . . . . . . . . . . . . . . . . 5-202
UPC/A preamble . . . . . . . . . . . . . . . . . . . . . . . . 5-204
UPC-A preamble . . . . . . . . . . . . . . . . . . . . . . . . 5-204
UPC-E preamble . . . . . . . . . . . . . . . . . . . . . . . . 5-208
data transmission formats . . . . . . . . . . . . . . . . . . . . 5-200
decode options . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6, 5-169
code 128 decode performance . . . . . . . . . . . . . 5-190
code 39 decode performance . . . . . . . . . . . . . . 5-195
decode redundancy for UPC/EAN . . . . . . . . . . 5-180
linear code type security . . . . . . . . . . . . . . . . . . 5-186
linear supplemental decode . . . . . . . . . . . . . . . 5-178
UPC/EAN decode performance . . . . . . . . . . . . 5-181
UPC/EAN security level . . . . . . . . . . . . . . . . . . 5-172
default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Index-iii
LS 5700/LS 5800 Product Reference Guide
E
EAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2, 2-10
EAS interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
enable
Bookland-EAN . . . . . . . . . . . . . . . . . . . . . . . . . 5-100
CLSI editing . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-141
codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-135
code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-110
code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-115
Index-iv
Index
H
hand-held laser scanner
connecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
hand-held laser scanner options . . . . . . . . . . . . . . . . 5-85
beep after good decode . . . . . . . . . . . . . . . . . . . 5-90
program all scanners . . . . . . . . . . . . . . . . . . . . . . 5-89
program hand-held scanner only . . . . . . . . . . . . 5-85
program LS2603MX/LS 3603MX/LS 3203 only . 5-87
program primary scanner only . . . . . . . . . . . . . . 5-86
program primary scanner only with
LS 2603MX/LS3603MX/LS 3203 . . . . . . . . . 5-88
hardware handshaking . . . . . . . . . . . . . . . . . . . . . . . . 5-35
host options
RS-232C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
host types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
RS-232C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
I
information, service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
input/output ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Index-v
LS 5700/LS 5800 Product Reference Guide
L
lengths
codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-137
code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-114
code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-120
interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . 5-128
M
maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
mounting
LS 5700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
LS 5800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
stainless steel top . . . . . . . . . . . . . . . . . . . . 2-16
N
notational conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
P
parameter menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
EAS interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
RS-232C host types . . . . . . . . . . . . . . . . . . . . . . 5-13
RS-232C port auxiliary options . . . . . . . . . . . . . . 5-56
RS-232C port host options . . . . . . . . . . . . . . . . . 5-19
set default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
programming utilities . . . . . . . . . . . . . . . . . . . . . 3-7, 5-246
application items . . . . . . . . . . . . . . . . . . . . . . . . 5-258
cancel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-256
Index-vi
Index
enter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-257
numeric bar codes . . . . . . . . . . . . . . . . . . . . . . . 5-246
R
random weight check digit . . . . . . . . . . . . . . . . . . . . 5-107
related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix
replacing other Symbol scanners . . . . . . . . . . . . . . . . 2-18
rest/sleep mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
routine maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
RS-232C host types . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
fujitsu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
ICL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
nixdorf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
no host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
single port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
RS-232C port auxiliary options . . . . . . . . . . . . . . . . . . 5-56
ASCII format . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-81
baud rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-57
check parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-70
hardware handshaking . . . . . . . . . . . . . . . . . . . . 5-72
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-74
standard RTC/CTS . . . . . . . . . . . . . . . . . . . 5-75
parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-65
even . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-66
mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-67
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-69
odd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-65
space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-68
serial response time-out . . . . . . . . . . . . . . . . . . . 5-78
software handshaking . . . . . . . . . . . . . . . . . . . . . 5-76
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-76
ON/XOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-77
Index-vii
LS 5700/LS 5800 Product Reference Guide
S
scanning bar codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
scanning made easy . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
scanning sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Index-viii
Index
T
technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
U
UCC/EAN-128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
W
what if . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Index-ix
LS 5700/LS 5800 Product Reference Guide
Index-x