Radiographic Interpretation Assessment: Multi - Choice Question Paper (MSR-ARI-1) Name
Radiographic Interpretation Assessment: Multi - Choice Question Paper (MSR-ARI-1) Name
Name:
a. 12 minutes.
b. 4 minutes.
c. 8 minutes.
d. 6 minutes.
a. Will be superimposed on top of the curve for the slow film but with a steeper gradient.
b. Will be superimposed on top of the curve for the slow film, but the length of the curve
will be different.
c. Will lie to the right of the curve for the slow film.
d. Will lie to the left of the curve for the slow film.
3. If we start with 50 curies of Co60, what will the activity be at the end of 15.9 years?
a. 12.5 curies.
b. 6.25 curies.
c. 3.125 curies.
d. 1.75 curies.
4. In welding which of the following processes may be considered for the welding of very
thick materials in excess of 100mm?
a. MMA (SMAW)
b. Electro-slag (ESW)
c. TIG (GTAW)
d. Plasma arc (PAW)
6. Which of the following types of crack is the most common type encountered, associated
with welds made on C-Mn steels?
a. Re-heat cracking.
b. Lamellar tearing.
c. Solidification cracking.
d. Hydrogen related cracks.
a. Yellow stain
b. Fine porosity.
c. Lightning like
d. Pink.
9. The projected (effective) focal spot size of an x-ray tube is determined by:
a. Cold crack.
b. Tearing.
c. Star crack.
d. Fatigue crack.
a. The sievert.
b. The roentgen.
c. The gray.
d. The Becquerel.
a. Produces relatively good quality radiographs at the correct exposure when compared
with radiographs produced with Ir192.
b. Produces very short wave length radiation.
c. Generally used with fluorometallic screens.
d. All of the above.
14. A trace on a radiograph which shows the relationship between the logarithm of the
exposure applied to a photographic film and the resulting photographic density is called:
a. A bar chart.
b. An exposure chart.
c. A logarithmic chart.
d. A characteristic curve.
20. The steeper the gradient of the straight line portion of a specific films characteristic curve:
a. A number.
b. Atomic mass number.
c. Z number.
d. N number.
a. Caesium 137.
b. Thulium 170
c. Cobalt 60
d. Iridium 192.
25. When producing radiographs with x-ray equipment, if the kilo-voltage is increased:
26. If a satisfactory radiograph has been achieved using the following exposure details,
exposure time = 2 min 45 seconds, mA = 3, f.f.d. = 10 inch, calculate a new exposure
time for the following changes, mA = 4.5, f.f.d. = 12 inch
a. 1.27 minutes.
b. 2 minutes 38 seconds.
c. 2.35 minutes
d. 1 minute 27 seconds.
27. What would be the result if a film is placed in a developer solution and allowed to
develop without any agitation and tapping?
a. BS EN 2910
b. BS EN 2600
c. BS EN 1435
d. BS EN 462