0% found this document useful (0 votes)
159 views10 pages

TC FLS Sihi Leh 1200 1500 1800 en

The document provides information on SIHI liquid ring vacuum pumps models LEH 1200, LEH 1500, and LEH 1800. The pumps are single-stage, displacement pumps with robust construction. They can handle dry and humid gases as well as small amounts of entrained liquid. Key specifications include a pressure range of 33 to 1013 mbar, suction volume flows from 440 to 2050 m3/h, and maximum compression pressures of 1.5 to 1.2 bar. The pumps require a continuous supply of service liquid, usually water, to remove heat from gas compression and replenish the liquid ring.

Uploaded by

Gustavo Zavala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
159 views10 pages

TC FLS Sihi Leh 1200 1500 1800 en

The document provides information on SIHI liquid ring vacuum pumps models LEH 1200, LEH 1500, and LEH 1800. The pumps are single-stage, displacement pumps with robust construction. They can handle dry and humid gases as well as small amounts of entrained liquid. Key specifications include a pressure range of 33 to 1013 mbar, suction volume flows from 440 to 2050 m3/h, and maximum compression pressures of 1.5 to 1.2 bar. The pumps require a continuous supply of service liquid, usually water, to remove heat from gas compression and replenish the liquid ring.

Uploaded by

Gustavo Zavala
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Liquid ring vacuum pumps

LEH 1200, LEH 1500, LEH 1800

Pressure range: 33 to 1013 mbar


Suction volume flow: 440 to 2050 m/h

CONSTRUCTION TYPE

SIHI liquid ring vacuum pumps are displacement pumps of


uncomplicated and robust construction with the following particular
features:
non-polluting due to nearly isothermal compression
oil-free, as no lubrication in the working chamber
handling of nearly all gases and vapours
small quantities of entrained liquid can be handled
easy maintenance and reliable operation
low noise and nearly free from vibration
wide choice of material, therefore applicable nearly
everywhere
Internal service liquid return; adjustable from the outside
protection against cavitation as standard
incorporated dirt drain
incorporated central drain NOTE
no metallic contact of the rotating parts
During operation the pump must continuously be supplied with
The SIHI liquid ring vacuum pumps LEH are single-stage ones.
service liquid, normally water, in order to eliminate the heat
resulting from the gas compression and to replenish the liquid ring,
because part of the liquid is leaving the pump together with the
APPLICATION gas. This liquid can be separated from the gas in a liquid separator
(see catalogue part accessories).
Handling and exhausting of dry and humid gases; entrained liquid It is possible to reuse the service liquid. The pumps are equipped
can be handled during normal duty. The pumps are applied in all with a device by which the contaminated service liquid can
fields where a pressure of 33 to 900 mbar must be created by continuously be drained during operation (dirt drain), if necessary.
robust vacuum pumps.
Fields of application are for example: The direction of rotation is clockwise, when looking from the drive
chemistry and pharmacy for distilling and degassing, on the pump.
electric industry for impregnation and drying
plastics industry for degassing etc.

GENERAL TECHNICAL DATA

Pump type unit LEH 1200 LEH 1500 LEH 1800


Speed 50 Hz rpm 975
60 Hz 1175
Max. compression over pressure bar 1,5 1,2
Max. admissible pressure difference bar 1,5 1,2
Hydraulic test (over pressure) bar 3
Moment of inertial of the rotating kg . m 2,6 3,05 3,5
pump parts and of the water filling
Sound pressure level
at a suction pressure of 80 mbar dB (A) 79
Min. pulley diameter permissible
in case of V-belt drive mm 355 500
Max. gas temperature dry C 200
saturated C 100
Service liquid
max. admissible temperature C 80
max. viscosity mm/s 90
max. density kg/m 1200
volume up to shaft level liter 30 35 39,5
Max. flow resistance bar 0,2
of the heat exchanger
The combination of several limiting values is not admissible.

VACUUM TECHNOLOGY LEH LE 5A


133.71330.52.01 E 07/2015
Material design

MATERIAL DESIGN
Item. COMPONENTS 0B 4B

10.60, 10.70 Casing 0.6025 1.4408

10.90 Central body 1.0553 1.4571

13.70, 13.71 Guide disk 0.6025 1.4408

21.00 Shaft 1.0503

23.50 Vane wheel impeller 0.7043 1.4517

43.30, 43.31 Standard mechanical seal Cr-steel / carbon / Perbunan Cr Ni Mo-steel / carbon / Viton

46.10 Gland packing Soft packing

52.40 Shaft sleeve 1.4027.05 1.4571

Sectional drawing LEH 1200, LEH 1500, LEH 1800

2
Suction volume flow and power absorption LEH 1200

1600
m/h 1175 rpm

1400
975 rpm
1200
suction volume flow

1000

800

600

400

200
LEH 1200
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

50
kW

40
power absorption

30
1175 rpm

20
975 rpm

10
LEH 1200

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

pumping medium: - dry air: 20C


- water vapour saturated air: 20C

service liquid: - water: 15C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

3
Suction volume flow and power absorption LEH 1500

2000
1175 rpm
m/h

975 rpm
1500
suction volume flow

1000

500

LEH 1500
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

60
kW
50
power absorption

40
1175 rpm
30

975 rpm
20

10
LEH 1500

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

pumping medium: - dry air: 20C


- water vapour saturated air: 20C

service liquid: - water: 15C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

4
Suction volume and power absorption LEH 1800

m/h
1175 rpm
suction volume flow 2000

975 rpm

1000

LEH 1800
0
10 40 60 80 100 200 400 mbar 1000
suction pressure

70
kW
60
power absorption

50

40 1175 rpm

30
975 rpm
20

10
LEH 1800

0
10 40 60 80 100 200 400 mbar 1000
suction pressure

The operating data are applicable under the following conditions:

pumping medium: - dry air: 20C


- water vapour saturated air: 20C

service liquid: - water: 15C

Compression pressure 1013 mbar (atmospheric pressure)


The suction volume flow is applied to the suction pressure
Tolerance of the operating data 10%
Max. fresh water need with lowest suction pressure

5
Dimension table LEH 1200, LEH 1500, LEH 1800

N1 = gas inlet DN 125


N2 = gas outlet DN 125
weight uB = connection for service liquid G 1
a m1 m2 o3 q3 app. kg
uc = connection for protection against cavitation G
LEH 1200 490 651 571 1150 632 479 ue = drain connection G
LEH 1500 560 721 641 1220 667 519 um1 = connection for drain valve G
LEH 1800 615 776 696 1275 695 549 use = connection for dirt drain G

flange connections to DIN 2501 PN 10


DN 100 125
k 180 210
D 220 250
number x d2 8 x 18 8 x 18

6
Arrangement drawing LEH 1200, LEH 1500, LEH 1800 with overhead liquid separator

N1 = gas inlet DN 125 uc = connection for protection against cavitation G


N2 = gas outlet DN 200 um = connection for pressure gauge G
uA = connection for liquid drain DN 65 ut = connection for thermometer G
uF = connection for fresh liquid DN 40

electric motor 50 Hz weight


size kW e1 e2 e3 l l1 m o1 * w1 * app. kg
IP 55 EEx e ll T3
LEH 1200 225 M 30 - 70 640 1370 1650 355 70 843 2043 1100
250 M - 33 690 1450 1750 930 2130 1225
LEH 1500 250 M 37 - 370 50 2200 1260
280 S - 40 50 1004 2274 1455
LEH 1800 280 S 45 - 735 1530 1900 388 40 2329 1500
280 M - 46 1055 2380 1570

flange connections to DIN 2501 PN 10


DN 40 65 125 200
k 110 145 210 295
D 150 185 250 340
number x d2 4 x 18 4 x 18 8 x 18 8 x 22
* dimensions dependent on the motor make

7
Arrangement drawing LEH 1200, LEH 1500, LEH 1800 with upright liquid separator

N1 = gas inlet DN 125 ue1 = drain connection DN 25


N2 = gas outlet DN 200 ufl = connection for liquid level indicator G
uA = connection for liquid drain DN 80 um = connection for pressure gauge G
uF = connection for fresh liquid DN 40 ut = connection for thermometer G
uc = connection for protection against cavitation G

electric motor 50 Hz weight


size- kW e1 e2 e3 l l1 m o1 * w1 * app. kg
IP 55 EEx e ll T3
LEH 1200 225 M 30 - 70 640 1370 1650 355 70 843 1997 1100
250 M - 33 690 1450 1750 930 2084 1225
LEH 1500 250 M 37 - 370 50 2154 1260
280 S - 40 50 1004 2228 1455
LEH 1800 280 S 45 - 735 1530 1900 388 40 2283 1500
280 M - 46 1055 2334 1565

flange connections to DIN 2501 PN 10


DN 25 40 80 125 200
k 85 110 160 210 295
D 115 150 200 250 340
number x d2 4 x 14 4 x 18 8 x 18 8 x 18 8 x 22
*dimensions dependent on the motor make

8
Fresh water requirements in [m/h] dependent on suction pressure, speed, mode of operation and difference in temperature

suction pressure in
33 120 200 400
[mbar]
KB KB KB KB
pump speed difference in FB difference in FB difference in FB difference in FB
temperature [C] temperature [C] temperature [C] temperature [C]
[rpm] 10 5 2 10 5 2 10 5 2 10 5 2
LEH 1200 975 1,3 2,3 4,3 1,7 2,7 4,3 1,7 2,7 4,2 1,7 2,5 3,6
1175 1,9 3,2 5,4 2,1 3,3 4,9 2,2 3,2 4,6 2,1 2,9 3,9
LEH 1500 975 1,5 2,7 4,8 10 2,0 3,1 4,7 7,2 2,0 3,1 4,5 6,4 1,9 2,8 3,8 5,0
1175 2,2 3,7 5,9 2,5 3,7 5,2 2,5 3,6 4,9 2,3 3,2 4,1
LEH 1800 975 1,8 3,0 5,2 2,2 3,3 4,9 2,2 3,3 4,7 2,1 3,0 3,9
1175 2,5 4,0 6,3 2,7 3,9 5,4 2,7 3,8 5,1 2,5 3,4 4,2

FB = fresh liquid service


KB =combined liquid service with service water 10 C, 5 C, 2 C warmer than the fresh water.

Data regarding the pump size - order notes

series + hydraulics + bearings shaft sealing material design casing seal


size

041 double gland


packing 0B main parts of GG
A hydraulic A
without non-ferrous
AAE mechanical seal metal 0 liquid
B two grease lubricated O-rings Perbunan seal
antifriction bearings 4B main parts of
Cr Ni Mo-cast steel
AA1 as AAE, but
O-rings Viton
1200
LEH 1500 AB 041, AAE, AA1 0B, 4B 0
1800

Design - Motor selection table

designation electric motor 50 Hz


pump with free shaft end 01 motor enclosure IP 55 motor enclosure EEx e ll T3
pump with coupling, pre-drilled at motor side 04 kW size designation kW size designation
as above, but with motor, for example 30 225 M AC 33 250 M BL
37 kW three-phase motor e.g. BC 37 250 M BC 40 280 S CL
(50 Hz, 400 V) at 975 rpm 45 280 S CC 46 280 M DL

Example for ordering:

The construction size LEH 1500 AB AAE 0B 0 with 37 kW three-phase ac motor (50 Hz, 400 V) 975 rpm
has the complete order number: LEH 1500 AB AAE 0B 0
BC

If motors with other voltage or frequency are required a special information should be given.

On delivery the point () in the fourth place of the type code is replaced by a letter in the factory.

9
Accessories

Recommended accessories LEH 1200 LEH 1500 LEH 1800

Overhead liquid separator type XBa 11540 XBa 12540 XBa 13240
weight 96 kg 100 kg 104 kg
material design 130 / galvanized SIHI part No. 35 008 563 35 009 504 35 009 509
172 / 1.4571 35 008 564 35 009 506 35 009 510
service liquid line
material design 072 / St 37-0 SIHI part No. 35 005 440 35 005 442 35 005 444
172 / 1.4571 35 005 441 35 005 443 35 005 445
cavitation protection line
material design 072 / St 37-0 SIHI part No. 20 027 920 20 027 921 20 027 922
172 / 1.4571 20 037 289 20 037 290 20 037 291
Upright liquid separator type XBp 2315
weight 98 kg
material design 130 / galvanized SIHI part No. 35 005 449
172 / 1.4571 35 005 447
service liquid line
material design 072 / St 37-0 SIHI part No. 35 005 434 35 005 436 35 005 438
172 / 1.4571 35 005 435 35 005 437 35 005 439
cavitation protection line
material design 072 / St 37-0 SIHI part No. 20 043 410 20 043 412 20 043 414
172 / 1.4571 20 043 411 20 043 413 20 043 415
SIHI-gas ejector
at service liquid temperature 15 C GEV 1200 A GEV 1500 A GEV 1800 A
at service liquid temperature 30 C GEV 1200 B GEV 1500 B GEV 1800 B
SIHI-ball type non-return valve type / weight XCk 150 / 35,8 kg resp. 43 kg
material design 767 / GG-25 SIHI part No. 20 072 800
784 / 1.4408 20 006 987
Reduction weight 16,5 kg
material design 072 / St 37-0 SIHI part No. 35 002 762
172 / 1.4571 35 014 264
Motor in case of standard design
IP 55 size 225 M 250 M 280 S
power 30 kW 37 kW 45 kW
weight 315 kg 420 kg 605 kg

EEx e ll T3 size 250 M 280 S 280 M


power 33 kW 40 kW 46 kW
weight 420 kg 605 kg 670 kg
Coupling
for motor IP 55 type / weight A 180 / 14 kg A 180 / 14 kg A 180 / 14 kg
pump side SIHI part No 43 035 527 43 035 527 43 035 527
motor side 43 021 496 43 034 392 43 021 495

for motor EEx e ll T3 type / weight ADS 194 / 17,5 kg ADS 194 / 17,5 kg ADS 218 / 24 kg
pump side SIHI part No 43 040 600 43 040 600 43 040 602
motor side 43 035 601 43 038 678 43 038 708
contact safety device
material design 076 / steel SIHI part No. 35 004 798
345 / 2.0321 35 004 803
base frame
for motor IP 55 081 / USt 37-1 SIHI part No. 35 005 431 35 005 432 35 005 433
weight 150 kg 155 kg 166 kg

for motor EEx e ll T3 081 / USt 37-1 SIHI part No. 35 005 432 35 005 433
weight 155 kg 166 kg

Any changes in the interest of the technical development are reserved.

Sterling SIHI GmbH


Lindenstrae 170, D-25524 Itzehoe, Germany
Telephone +49 (0) 48 21 / 7 71-01, Fax +49 (0) 48 21 / 7 71-274
www.sihi.com