Pump Sizing Calculation: Data Flowrate
Pump Sizing Calculation: Data Flowrate
Data
Flowrate
68 m/h
Density
900 Kg/m
Viscosity
1.64 cP
Vapor Pressure
0.15 Bar A
Pump Efficiency
50.0 %
Result
Suction
Pressure
1 Bar A
Static Head
-3 m
Equipment Loss
0.01 Bar
Length
16 m
Schedule / Thickness
0.375
# Fittings K DP
Suction Hydraulics
Pipe ID 95.250 mm
Discharge
Pressure
5 Bar A
Static Head
4.5 m
Equipment Loss
0.7 Bar
Length
20 m
Schedule / Thickness
0.375
# Fittings K DP
Discharge Hydraulics
Pipe ID 95.250 mm