0% found this document useful (0 votes)
42 views

Design Parameter Frame Ar-Af 4.5 M

This document provides the design parameters for a frame with dimensions of 2m x 1m x 4.5m high intended to support a service load of 2.5 tons. It specifies the materials used, including pipes of various diameters, and analyzes the frame to check that the unity check ratio is less than 1, displacements are less than allowable limits, and support reactions are less than capacity. The conclusion is that the frame arrangement is safe to use for the intended 2.5 ton service load weight.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Design Parameter Frame Ar-Af 4.5 M

This document provides the design parameters for a frame with dimensions of 2m x 1m x 4.5m high intended to support a service load of 2.5 tons. It specifies the materials used, including pipes of various diameters, and analyzes the frame to check that the unity check ratio is less than 1, displacements are less than allowable limits, and support reactions are less than capacity. The conclusion is that the frame arrangement is safe to use for the intended 2.5 ton service load weight.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 12

DESIGN PARAMETER FRAME AR-AF 4.

5 M
SWL 2.5 TON

DIMENSION
1 LENGTH 2M
2 WIDTH 1M
3 HEIGHT 4.5 M

MATERIAL
1 PIPE 4 SCH.80 1 M
2 PIPE 3 SCH.80 12 M
2 PIPE 2 SCH.80 8 M
2 C.200x80 3 M

LOAD
1. DEAD LOAD = SWL 2.5 TON

LOAD COMBINATION
COMBINATION 1 = 1.25 DL
1. GEOMETRY & DIMENSION

2. DIMENSION

PIPE 4 SCH.80 1 M

PIPE 3 SCH.80 12 M
PIPE 2 SCH.80 8 M

C.200x80 3 M

3. YIELD STRESS STEEL


4. TUBE PLACEMENT

VIEW YZ LEFT
VIEW YZ RIGHT

VIEW XZ FRONT
VIEW XZ BACK

VIEW XY
5. FACTOR FOR SELF WEIGHT 1.25 x SWL 2.5 TON

6. SERVICE LOAD AND PERMISSIBLE ACTIVITY ARE COMPLY

USE SWL 2.5 TON = 2500 Kg


7. THE ANALYSIS SHALL BE PERFORMED FOR DESIGN CONDITIONS

JOINT LABEL

FRAME LABEL
FRAME SECTION

8. UC RATIO < 1

RESULT = 0.527 < 1 OK.


UC TABLE VALUE

Fram Design DesignT


e Sect ype Status Ratio
Unitles
Text Text Text Text s
0.2816
15 PIPE 3 IN Column No Messages 87
0.0016
16 C200x75 Beam No Messages 62
0.2816
19 PIPE 3 IN Column No Messages 87
0.0016
20 C200x75 Beam No Messages 62
0.0559
24 PIPE 2 IN Brace No Messages 1
0.0559
25 PIPE 2 IN Brace No Messages 1
0.0559
26 PIPE 2 IN Brace No Messages 1
0.0559
27 PIPE 2 IN Brace No Messages 1
0.5269
28 PIPE 3 IN Beam No Messages 17
0.0246
29 PIPE 4 IN Beam No Messages 97
0.2327
30 PIPE 4 IN Beam No Messages 42
0.0246
31 PIPE 4 IN Beam No Messages 97
0.2014
32 PIPE 2 IN Brace No Messages 06
0.2014
33 PIPE 2 IN Brace No Messages 06
9. DISPLACEMENT < ALLOWABLE (LENGTH OF SPAN /100)
DISPLACEMENT HORIZONTAL

RESULT : 8.77 mm < H = 2000/100 = 20 OK!!

DISPLACEMENT VERTICALL

RESULT : 15.22 mm < H = 4500/100 = 45 OK!!

10. SUPPORT REACTION < CAPACITY


SUMMARY & CONCLUSION
TABLE COMPARISON MAX. VALUE WITH ALLOWABLE VALUE

COMPARISON
N REMARK
DESCRIPTION MAX.
O S
VALUE ALLOWABLE VALUE

UC ( Unity
0.527
1 Check) < 1 OK

2 Displacement
V = L / 100 = 4500/ 100 =
15.22 mm
Vertical < 45 mm OK
H = L / 100 = 2000/ 100 =
8.77 mm
Horizontal < 20 mm OK
( Max displacement criteria
shall be as per BS.1139.5
section 5.2.7)

Conclusion : STRUCTURE FRAME arrangement "SAFE TO BE


USED FOR SWL 2.5 TON "