Sidytrac PI 76
Sidytrac PI 76
com/rail-electrification
With the help of Sitras Sidytrac the system design and Safety of persons and protection of installations
calculation of the complete traction power supply system Calculation of rail potentials/touch voltages
is carried out. Assessment of stray currents for DC railways
Protection design
Areas of application Short circuit calculations DC/AC railways
Maximum operational currents of feeding sections
Overall system design
Design parameters for relay coordination
Simulated train operation and network calculation for
AC and DC railways Network reaction / power quality
Optimization of feeding concepts 3-phase unbalance because of single-phase railway loads
Definition of substation locations 3-phase voltage fluctuation study
Energy demand calculations for railway lines Resonance behavior of railway lines
Calculation and assessment of contingency operation
Current load of contact lines, cables, busbars, switchgears and Interference, magnetic fields, electromagnetic compatibility
transformers Studies and calculations of electric and magnetic fields of railway
Calculation of line impedances and potentials along the line lines and/or traction substations
Assessment of controlled substations (inverter, double converter), Calculation of psophometric interference in telecommunication
energy storage units cables, i.e. frequency analyzis of the electromagnetic
Calculation of current distribution of contact lines interference
Dimensioning of active balancer Sitras RAB plus and mobile Rail Mutual interference between DC and AC railways
Var balancer Sitras RVC plus Induced voltages in parallel conductors, e.g. cable screens and
signal lines
Program structure
Eingabeblock
Input block Calculation
Berechnungsblock
block Ausgabeblock
Output block
Streckendaten
Railway network, Fahrauftrge Grafische Kontrolle
topography der Eingabedaten
Leistungsbedarf der Fahrzeuge
Vehicle Mission driving curves
Fahrzeug Mechanische / elektrische
Statisches Netz Ergebnisse der Fahrzeuge
Schedule
Elektrisches Netz
Vehicle movement acc. to Mechanical / electrical
available power results of vehicles
Electrical network
results
2
The simulation software Sitras Sidytrac consists of three Second, the electrical loadflow calculates the cur-
blocks: rents, voltages and the available power in all nodes and
yy Input block branches of the network for the next step of train move-
yy Calculation block ment.
yy Output block
At the end of the processes all mechanical and electrical
Input block quantities are available for evaluation and graphical repre-
sentation.
The program input block serves to condition the railway
network as well as traction unit, schedule, and electrical
network data. Complex railway networks with main and
branch lines can be modelled.
Input data
Schedule
Synchronized schedules
Individual schedules
Quasi-stochastic schedules
Vehicle data
Mass
Maximum speed
Traction resistance Input railway network
Efficiency
Power factor
Traction and braking efforts
Auxiliaries, power consumption
Electrical network
Network topology
Feeding points and short-circuit power
Transformers
Rectifiers, inverters, energy storage units, reactive power com-
pensation
Switchgears
Feeders (overhead power lines, cables)
Contact line system
Resistors, reactors, capacitors
Stationary concumers
Calculation block
3
Output block
Output data
Vehicle results
Currents
Voltages
Total power
Traction power
Recuperated power
Losses in braking resistance
Mechanic power
Auxiliaries
Losses Sitras Sidytrac repor t : Total energy flow
Power factor
Efficiencies
Position
Velocity
Acceleration
Traction effort
Braking effort
Payload
[email protected]
Representation www.siemens.com/rail-electrification
The results and the related input data are stored in a data-
Siemens AG 2014
base and automatically processed and customized into a
customer-specific adaptable browser-enabled format. This Produktinformation / Version 1.2.0 / No. A6Z08111122394
feature enables the customer to perform easy-to-use ana- The information in this document contains general descriptions of the technical options
lyzing functions. available, which do not always have to be present in individual cases. If not stated other-
wise, we reserve the right to include modifications, especially regarding the stated values
and dimensions.