0% found this document useful (0 votes)
576 views

RCEL-006-250 Data (US)

Remote Control RCEL Series Electric Actuators are engineered to provide efficient, high performance automation of quarter turn valves.

Uploaded by

tomescu_sorin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
576 views

RCEL-006-250 Data (US)

Remote Control RCEL Series Electric Actuators are engineered to provide efficient, high performance automation of quarter turn valves.

Uploaded by

tomescu_sorin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ELECTRIC T E C H N I C A L D ATA S H E E T

Remote Control RCEL Series


RCEL Series Actuators Electric Actuators are engineered
to provide efficient, high perfor-
mance automation of quarter turn
valves. The RCEL Series has
improved reliability incorporating
all the best features.

OPTIONS
EXP Explosion & Water Proof Enclosure
Class I C & D / Class II E, F & G
Exd IIB T4 IP67
DCM 24 VDC Motor (RCEL-6 thru
RCEL-28)
ACM 24 VAC Motor (RCEL-6 thru
RCEL-28)
ALS Auxiliary Limit Switches 2 SPDT
switches (6 aux switches max)
EXT Extended Travel Angle
120 to 360 (RCEL-6 thru
RCEL-100)
LCU Local Control Unit (NEMA-4)
FEATURES local/remote selector switch
open/stop/close selector switch
Standard enclosure IP-67, NEMA 4, 4x
LCU Local Control Unit (NEMA-4)
Squirrel cage, totally enclosed motor KEY w/key with key lock
Standardized and color-coded wiring PIU 1K Ohm Feedback Potentiometer
Manual override hand/auto declutch lever, automatic reset CPT Current Position Feedback
when motor is energized Transmitter 4-20mA DC output
DCT VDC Position Feedback Transmitter
Handwheel designed for safe, efficient operation
1-5VDC, 0-5VDC and 0-10VDC
Mounting standardized to ISO-5211; removable drive bushing PCU Proportional Control Unit
can be machined to match valve stem 4-20mA, 1-5VDC or 0-10VDC input
Wormgear drive for longer life and low maximum noise level IMS Integral Motor Starter
of 50dB includes reversing contactors
and step down transformer
Indicator top mounted for continuous visual indication of
valve position CLC Repeat Cycle Timer for cycle
length control
20 watt internal heater to minimize condensation due to
ATS Auxiliary Torque Switches 2 SPDT
temperature and humidity changes switches (RCEL-15 thru RCEL-250)
Cam actuated, end of travel limit switches are easily adjusted
to de-energize actuator for precise valve position
Torque switch is cam actuated and factory set to provide over
torque protection for valves, available in size RCEL-15 thru
RCEL-250
Mechanical limit stops designed to prevent over-travel of
quarter turn applications
Valve backdrive is prevented by a rolled steel wormgear
and aluminum bronze wormwheel
CSA C/US Approval on 120 VAC only

Remote Control Inc. P.O. Box 355 North Kingstown, RI 02852


Phone 401-294-1400 Fax 401-294-3388 Email [email protected] Website www.rciactuators.com
RCEL Series T E C H N I C A L D ATA S H E E T

STANDARD SPECIFICATIONS
Enclosure Watertight IP67, Nema 4, 4x
Ambient Temp. From -20 to +158 Fahrenheit
300 Fahrenheit for 1 hour
Power Supply 120/220VAC 1-Phase
380/440VAC 3-Phase
Control Power 110/220VAC 1-Phase, 50/50Hz
Duty Cycle See Performance Chart
Torque Switches (2) Open/Close (RCEL-15 thru RCEL-250)
Limit Switches (2) Open/Close, 250 VAC 16A Rating
Stall Protection Internal Thermal Protection
Open 300F/Close 207F
Travel Angle 90 5
Indicator Continuous Position Indicator
Manual Override HAND/AUTO Declutching Mechanism
Self Locking Provided by means of Worm Gearing
Mechanical Stops External Adjustable Screws
Space Heater 20Watt (24/120/220 VAC and 24 VDC)
Anti-Condensation
Conduit Entries Two 3/4 NPT.
Lubrication Grease Moly (EP) Type
Materials Steel, Aluminum Alloy, Aluminum Bronze
Surface Treatment Anodizing
External Coating Dry Powder, Epoxy-Polyester

PERFORMANCE

Max Operating Time Duty Cycle Rated Current Amps/Locked Rotor Amps
TYPE Output Torque 60/50 hz 30 min. 1-Phase 3-Phase
Inch Pounds 90 T.P. 120vac 220vac 380vac 440vac Weight Lbs.
RCEL-6 521 14/17 100% 0.66/1.36 0.29/0.83 0.12/0.33 0.14/0.37 24
RCEL-9 781 14/17 100% 1.07/2.10 0.49/0.87 0.14/0.37 0.17/0.41 24
RCEL-15 1302 17/20 80% 1.45/2.14 0.71/1.12 0.30/0.61 0.30/0.65 27
RCEL-19 1649 17/20 80% 1.60/2.97 0.90/1.52 0.33/0.77 0.34/0.83 29
RCEL-28 2430 20/24 100% 1.60/2.97 0.90/1.52 0.33/0.77 0.34/0.83 38
RCEL-38 3298 20/24 100% 1.95/3.75 1.26/1.85 0.36/0.80 0.37/0.87 40
RCEL-50 4340 20/24 80% 3.10/4.90 1.50/2.34 0.56/1.27 0.57/1.36 42
RCEL-60 5208 24/29 80% 3.10/4.90 1.50/2.34 0.56/1.27 0.57/1.36 49
RCEL-80 6944 24/29 70% 4.10/7.50 2.15/3.70 0.84/1.76 0.78/1.88 51
RCEL-100 8680 24/29 70% 4.10/7.50 2.15/3.70 0.84/1.76 0.78/1.88 55
RCEL-150 13020 72/87 80% 3.10/4.90 1.50/2.34 0.56/1.27 0.57/1.36 150
RCEL-200 17360 72/87 70% 4.10/7.50 2.15/3.70 0.84/1.76 0.78/1.88 154
RCEL-250 21700 72/87 70% 4.10/7.50 2.15/3.70 0.84/1.76 0.78/1.88 154
RCEL Series T E C H N I C A L D ATA S H E E T

DIMENSIONS

MODEL RCEL-6 RCEL-9 RCEL-15 RCEL-19 RCEL-28 RCEL-38 RCEL-50 RCEL-60 RCEL-80 RCEL-100 RCEL-150 RCEL-200 RCEL-250
ISO 5211
FLANGE F-07 F-07 / F-10 F-10 /F-12 F-12 /F-14 F-16
A 2.76 2.76 / 4.02 4.02 / 4.92 4.92 / 5.51 6.5
B M8 M8 / M10 M10 / M/12 M12 / M16 M20
Thread 1.25 1.25 / 1.5 1.5 / 1.75 1.75 / 2.0 2.5
Pitch
C .47 .59 .71 .87 1.18
D-MAX 0.87 0.87 1.26 1.65 2.95
E 2.17 2.24 2.95 3.35 3.94
F 1.69 1.69 2.05 2.32 3.87
G .08 .08 .08 .08 .28
H 9.09 10.28 11.22 12.8 12.8
I 2.21 3.03 3.27 3.9 3.9
J 6.89 7.25 7.95 8.9 8.9
K 2.36 2.36 2.76 3.07 3.07
L 8.39 8.39 9.84 11.14 11.14
M 10.75 10.75 12.6 14.21 14.21
N 4.02 4.73 5.71 6.89 10.47
O 2.68 3.35 3.9 4.57 4.57
P 4.45 5.47 6.26 7.52 7.52
Q 7.13 8.82 10.16 12.09 12.09
R 4.25 4.25 5.12 7.01 7.01
S 4.02 4.92 4.92 6.69 6.69
T NA NA NA NA 21.89
U NA NA NA NA 7.68
X NA NA NA NA 15.28
Y NA NA NA NA 0.63
Z NA NA NA NA 12.52
B dimension is metric. All other dimensions are inches.
RCEL Series T E C H N I C A L D ATA S H E E T

APPLICATION DATA

CUSTOMER DETAIL
Company _____________________________________ Job ____________________________________________
Street ________________________________________ ________________________________________________
City ___________________________________________ Item____________________________________________
Zip ____________________________________________ Tag ____________________________________________
Attention ______________________________________ ________________________________________________

VALVE INFORMATION
Mfg _____________________________Type ____________ Size _________ Fig No _________________________________
Valve rotation to close (as viewed from top) _______ Clockwise ________ Counter-clockwise ________
Max. required torque (with safety) ______________ Inch Pounds.

ACTUATOR REQUIREMENTS
Application ___________ Open/Close Service ________ Modulating Service _______ Other _____________________
Ambient Temperature ___________ F to ____________F
Supply Voltage _________ volt AC __________Hz, 1- phase or 3-phase ________ volt DC
Control Voltage ________ volt AC __________ Hz, 1- phase or ________volt DC. (When IMS is required)

OPTIONAL ITEMS (AS REQUIRED)


Position Feedback Transmitter __________________________ (4-20A, 0-5vdc, 1-5vdc or 0-10vdc)
Proportional Control Unit _______________________________ (4-20mA, 1-5vdc or 0-10vdc)
Aux. Limit Switch (6-max) ______________________________ Integral Motor Starter ___________________________
Local Control Unit______________________________________ Delay On/Off Relay _____________________________
Cycle Timer Control ____________________________________ Other __________________________________________

Remote Control Inc. P.O. Box 355 North Kingstown, RI 02852


Phone 401-294-1400 Fax 401-294-3388 Email [email protected] Website www.rciactuators.com