0% found this document useful (0 votes)
193 views

Column Foundation Connection

The document summarizes the design of a column foundation connection. It provides input parameters for the column size, loads, material strengths, and connection geometry. It then shows calculations to determine the required base plate size, thickness, steel reinforcement, and number of bolts according to design code standards. The output includes a base plate 600mm x 500mm x 34mm thick connected to the column with 4 M16 bolts at a 50mm distance from the column.

Uploaded by

mdelacua2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
193 views

Column Foundation Connection

The document summarizes the design of a column foundation connection. It provides input parameters for the column size, loads, material strengths, and connection geometry. It then shows calculations to determine the required base plate size, thickness, steel reinforcement, and number of bolts according to design code standards. The output includes a base plate 600mm x 500mm x 34mm thick connected to the column with 4 M16 bolts at a 50mm distance from the column.

Uploaded by

mdelacua2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Subject:

DESIGN OF COLUMN FOUNDATION CONNECTIONS


Precast Concrete Structures Design Code: Designed By: Date:
B.S. 8110 Part 1 Engr. WBL 23-Mar-17

Code Ref. CALCULATIONS & SCKETCHES Output

Input Data:
Columns Size:
column width, bc = 300 mm
column depth, dc = 400 mm
Column Loads:
Axial Load, N = 2000 kN
Column Moment(major axis), M = 300 kN-m
projection length, L = 100 mm
dist from plate edge to holding down
bolts, d' = 50 mm
fcu = 40 N/mm
fy = 460 N/mm
yeild strength of plate, y = 275 N/mm

Solution:
eccentricity, e = 150 mm provide tension reinf.!! i.e.: e = M/N

plate width, b = 500 mm i.e.: b = bc + 2L


plate depth, d = 600 mm i.e.: d = dc + 2L

eccentricity, e = 150 mm i.e.: e = M/N


Precast
Concrete
Structures, Eq. 0.917X - 0.5X = 0.278
9.46
from quadratic eqation: a = 0.5 -b = 0.917 c = 0.278

X = 0.383

X< N / 0.4fcubd = 0.417 F is negative !, set F = 0

Eq. 9.52 X = 0.5 i.e.:

Eq. 9.53 fc = 13.3 N/mm

Eq. 9.54 thickness of base plate, t = 32 mm


Subject:
DESIGN OF COLUMN FOUNDATION CONNECTIONS
Precast Concrete Structures Design Code: Designed By: Date:
B.S. 8110 Part 1 Engr. WBL 23-Mar-17

Code Ref. CALCULATIONS & SCKETCHES Output


Subject:
Precast Concrete DESIGN OF COLUMN FOUNDATION CONNECTIONS/BASE PLATE
Design Code: Designed By: Date:
Structures B.S. 8110 Part 1 Engr. WBL 23-Mar-17
Code Ref. CALCULATIONS & SCKETCHES Output

Input Data:
Columns Size:
column width, bc = 300 mm
column depth, dc = 400 mm

Column Loads:
Axial Load, N = 600 kN
Column Moment(major axis), M = 300 kN-m
projection length, L = 100 mm
dist from plate edge to holding
down bolts, d' = 50 mm
fcu = 40 N/mm
fy = 460 N/mm
yeild strength of plate, y = 275 N/mm
yeild strength of bolts, fyb = 450 N/mm

Solution:
eccentricity, e = 500 mm provide tension reinf.!! i.e.: e = M/N

plate width, b = 500 mm i.e.: b = bc + 2L

plate depth, d = 600 mm i.e.: d = dc + 2L

eccentricity, e = 500 mm i.e.: e = M/N


Precast
Concrete
Structures, Eq. 0.917X - 0.5X = 0.156
9.46

from quadratic eqation: a = 0.5 -b = 0.917 c = 0.156

X = 0.190

X >N / 0.4fcubd = 0.125 X >, F is positive, calculate of F!

Eq. 9.44 F = 312.46 kN

Eq. 9.49 Ab = 347.2 mm

no. of bolts each root area, N = 2


Use: 4 nos. M 16 Grade 8.8 holding down bolts bolt dia., db = M16

Eq. 9.51 thickness of base plate, t = 30 mm


dist. from c/c of bolts & bars in column, m = 50 mm

Eq. 9.50 thickness of base plate, t = 34 mm


Use: 600 mm X 500 mm X 34 mm base plate