100% found this document useful (1 vote)
536 views

ES - Swiming Pool Calculation

1. The document provides structural design calculations for an underground swimming pool, including material properties, loading conditions, bending moment calculations, and reinforcement requirements. 2. Key loads on the retaining wall include active soil pressure up to 8.11 kPa, hydrostatic water pressure up to 12 kPa, and a surcharge of 4.54 kPa from the ramp slab. 3. The maximum bending moment is calculated to be 35.85 kNm/m, requiring 5 bars of 12mm reinforcement spaced at 200mm centres along the length of the wall.

Uploaded by

prabhu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
536 views

ES - Swiming Pool Calculation

1. The document provides structural design calculations for an underground swimming pool, including material properties, loading conditions, bending moment calculations, and reinforcement requirements. 2. Key loads on the retaining wall include active soil pressure up to 8.11 kPa, hydrostatic water pressure up to 12 kPa, and a surcharge of 4.54 kPa from the ramp slab. 3. The maximum bending moment is calculated to be 35.85 kNm/m, requiring 5 bars of 12mm reinforcement spaced at 200mm centres along the length of the wall.

Uploaded by

prabhu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

STRUCTURAL DESIGN CALCULATION

Date : 05-May-16
Part : UG Swimming Pool Number: Element :
Project :

a) Material Proerties
fcu : 40 MPa (28 days compressive cube strength of concrete)
fy : 500 MPa (Characteristic steel strength)
3
wc : 25 kN/m (unit wt. of concrete)
2
Soil qallow : 350 kN/m (Net Safe bearing capacity of soil)
3
s : 18 kN/m (unit wt. of soil)
w : 10 kN/m3 (unit wt. of water)
: 27 deg (angle of internal friction of soil)
: 0.5 (Conc. friction factor)
Depth of foundation : 1.2 m (Top of footing)

b) Loading
Soil Pressure
Rankins coefficient ka : (1-sin)/(1+sin)
: 0.38
Ht. of RT wall Hs : 1.20 m

Active pressure on wall


pa : ka s H
: 8.111 kPa (maximum at bottom of wall)

Various earth pressure on wall at varying depths.


S.No. depth pressure
1 0.6 4.06
2 0.9 6.08
3 1.2 8.11
4 1.50 10.14
5 1.50 10.14

Water Pressure
max water level Hw : 1.20 m

Hydrostatic pressure on wall


pa : w H
: 12 kPa (maximum at bottom of wall)

Surcharge due to ramp


Live load on wall L1 : 3.13 kPa
Self wt. of solid slab L2 : 1.41 kPa
L : 4.54 kPa

Surcharge due to ramp slab and live load


pa : ka L
: 1.704 kPa (applied uniformly on walls)
STRUCTURAL DESIGN CALCULATION

Date : 05-May-16
Part : UG Swimming Pool Number: Element :
Project :

c) BM Calculation
Max. ht. of wall h : 1.50 m
Pa : 14.19 kPa (with load factor 1.4)
Surcharge PL : 7.26 kPa (with load factor 1.6)

BM : Pa*1/3h + PL*h2/2
: 35.85 kNm/m (Ultimate load)
: 24.88 kNm/m (Service load)

Reinforcement required
Wall thickess t : 300 mm
Effective depth of footing d : 242 mm
Along Length
bx : 1000 mm
Mux : 35.8 kNm

Here, k : Mu/bd2fcu (BS-8110-1:1997- Sec.3.4.4.4)


: 0.015
< 0.156, hence comp. reinf. is not required.

zx : 237.8 mm
but not greater than, 0.95d 0.95d : 229.9 mm
z : lesser of {237.81, 0.95 d}
zx : 229.9 mm
Required reinforcement for the BM,
As,req : Mu/0.87Fyz
2
Asx,req : 358.5 mm

Provide reinforcement along x direction as


12 mm @ 200 mm c/c. no. of bars : 5 nos.
2
Asx,prov : 565 mm > 358.45 sqmm, Hence o.k.